readme.txt Driver File Contents (bmcfw1_19.exe)

 See example.bat for command line example.
 
  Bmcsdrup.exe updates BMC firmware using Bmcfg.inf and data files
 (bmcfw.dat, fru.dat, and itf.dat).
 
  Bmcsdrup.exe can update BMC firmware, FRU, and ITF using bmcfg.inf or command line options. 
  Operator can describe following information in the Bmcfg.inf file or command line options.
 
 
 
(1)Command line option vs. bmcfg.inf
 
  Operator can use two methods for describing option command.  First one is 
 command line option.  Second one is using bmcfg.inf.  The combination of
 command line options and bmcfg.inf file is used at the same time.
  The command line options have priority from bmcfg.inf for executing
 Bmcsdrup.exe
 
 
 
  bmcfg.inf :  Information file that is used by Bmcsdrup.exe for updating BMC
              firmware. Bmcsdrup.exe reads this file and operates by
              instructions in this file. 
  bmcfw.dat :  BMC(Baseboard Management Controller) firmware data
  fru.dat   :  PIA(Platform Information Area) data
  itf.dat   :  Boot block data
 
 
 
(2)Information file Format (bmcfg.inf)
 
  [bmcfw update data] MODE=xx HWID=xxxx WAIT=xx
  bmcfw.dat
  fru.dat
  itf.dat
 
 
  The form of the update operation is described to the first line.
  The one after the second line describes the data file name of the object.
 
 
 
 MODE
 
   Operator can select and describe operational mode as follows.
 
    MODE=xx
 
  This MODE code (xx in example) that is following.

    00 :  A confirmation message is displayed before the update operation.
         After the update operation was completed, DC is turned off.
    10 :  A confirmation message is displayed before the update operation.
         After the update operation was completed, DC is turned off if any
         key is entered.
    20 :  A confirmation message is displayed before the update operation.
         After the update operation was completed, DC is turned off if any
         key is entered or setting time passes.
    01 :  A confirmation message is not displayed before the update operation.
         After the update operation was completed, DC is turned off.
    11 :  A confirmation message is not displayed before the update operation.
         After the update operation was completed, DC is turned off if any
         key is entered.
    21 :  A confirmation message is not displayed before the update operation.
         After the update operation was completed, DC is turned off if any
         key is entered or setting time passes.
    02 :  This saves version information of BMC firmware to bmcrev.txt
         on current directry. Bmcsdrup.exe will terminate after saving data
         automatically. The bmcrev.txt is auto-created by Bmcsdrup.exe
 
 
 
 HWID
 
   Operator can select and describe Hardware ID for recognizing hardware.
 
    /HWID=xxxx
 
 
    0000     :  no check HWID. 
    Not 0000 :  HWID as hex data. Bmcsdrup.exe check this hardware ID code
               with hardware ID on the machine. If the result is "wrong",
               Bmcsdrup.exe will display error messages and terminate.
               Operator must describe the HWID with four characters. Operator
               can describe HWID less than 16 with "," as separator. Operator
               can omit this option. Default value of this option is "0000".
 
 
 
 WAIT
 
   Operator can select and describe WAIT time value for time wait to DC-OFF
 after updated firmware.  This value is used at  MODE 20 and 21.
 
    WAIT=xx
 
 
   xx :  wait time value of seconds (from 00 to 99 decimal number). 
         Operator can omit this option. Default value of this option is 30
        seconds.
         Operator can break waiting process by key in, then the BMC will turn
        DC off soon.
 
 
 
(3)Command line option
 
 bmcsdrup [option1] [option2] ....[optionN]
 
   /?     :  bmcsdrup.exe will display command line help.
   /h     :  bmcsdrup.exe will display command line help.
   /H     :  bmcsdrup.exe will display command line help.
   /MODE  :  bmcsdrup.exe will select and describe operational mode.
   /HWID  :  bmcsdrup.exe will select and describe Hardware ID for
            recognizing hardware.
   /WAIT  :  bmcsdrup.exe will select and describe WAIT time value for time
            wait to DC-OFF after updated firmware.
   /FILE  :  bmcsdrup.exe select and describe update data file names for
            update process.
 
 
 
 Command line option (/MODE)
 
  Operator can select and describe operational mode as follows.
 
    /MODE=xx
 
  This MODE code (xx in example) that is following.
 
    00 :  A confirmation message is displayed before the update operation.
         After the update operation was completed, DC is turned off.
    10 :  A confirmation message is displayed before the update operation.
         After the update operation was completed, DC is turned off if any
         key is entered.
    20 :  A confirmation message is displayed before the update operation.
         After the update operation was completed, DC is turned off if any
         key is entered or setting time passes.
    01 :  A confirmation message is not displayed before the update operation.
         After the update operation was completed, DC is turned off.
    11 :  A confirmation message is not displayed before the update operation.
         After the update operation was completed, DC is turned off if any
         key is entered.
    21 :  A confirmation message is not displayed before the update operation.
         After the update operation was completed, DC is turned off if any
         key is entered or setting time passes.
    02 :  This saves version information of BMC firmware to bmcrev.txt
         on current directry. Bmcsdrup.exe will terminate after saving data
         automatically. The bmcrev.txt is auto-created by Bmcsdrup.exe
 
 
 Command line option (/HWID)
 
  Operator can select and describe Hardware ID for recognizing hardware.
 
    /HWID=xxxx
 
 
    0000     :  no check HWID. 
    Not 0000 :  HWID as hex data. Bmcsdrup.exe check this hardware ID code
               with hardware ID on the machine. If the result is "wrong",
               Bmcsdrup.exe will display error messages and terminate.
               Operator must describe the HWID with four characters. Operator
               can describe HWID less than 16 with "," as separator. Operator
               can omit this option. Default value of this option is "0000".
 
 
 
 Command line option (/WAIT)
 
   Operator can select and describe WAIT time value for time wait to DC-OFF
 after updated firmware.  This value is used at  MODE 20 and 21.
 
    /WAIT=xx
 
 
   xx :  wait time value of seconds (from 00 to 99 decimal number). 
         Operator can omit this option. Default value of this option is 30
        seconds.
         Operator can break waiting process by key in, then the BMC will turn
        DC off soon.
 
 
 
 Command line option (/FILE)
 
  Operator can select and describe update data file names for update process.
 Operator can describe file names with "," as separator.
 
    /FILE=bmcfw.dat, fru.dat, itf.dat
 
 
 
Download Driver Pack

How To Update Drivers Manually

After your driver has been downloaded, follow these simple steps to install it.

  • Expand the archive file (if the download file is in zip or rar format).

  • If the expanded file has an .exe extension, double click it and follow the installation instructions.

  • Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.

  • Find the device and model you want to update in the device list.

  • Double-click on it to open the Properties dialog box.

  • From the Properties dialog box, select the Driver tab.

  • Click the Update Driver button, then follow the instructions.

Very important: You must reboot your system to ensure that any driver updates have taken effect.

For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.

server: ftp, load: 1.62