0 1 {No error has occurred} 1 0 {Invalid board number} 2 0 {Digital device is not responding - Is base address correct?} 3 0 {Counter device is not responding - Is base address correct?} 4 0 {D/A is not responding - Is base address correct?} 5 0 {A/D is not responding - Is base address correct?} 6 0 {Selected board does not have digital I/O} 7 0 {Selected board does not have a counter} 8 0 {Selected board does not have a D/A} 9 0 {Selected board does not have an A/D} 10 0 {Selected board does not have thermocouple inputs} 11 0 {Invalid digital port number} 12 0 {Invalid counter device} 13 0 {Invalid D/A device} 14 0 {Invalid sample mode} 15 0 {Board configured for invalid interrupt level} 16 0 {Invalid A/D channel number} 17 0 {Invalid count} 18 0 {Invalid counter configuration specified} 19 0 {Invalid D/A value} 20 0 {Invalid D/A channel number} 21 0 {Invalid error code} 22 0 {Background operation already in progress} 23 1 {DMA transfer crossed page boundary, may have small gap in data} 24 0 {Invalid sampling rate} 25 0 {Board switches set for Compatible mode} 26 1 {Incorrect initial trigger state - D0 must start at TTL low} 27 0 {A/D is not responding} 28 1 {Trigger occurred before requested number of samples were collected} 29 1 {Data overrun - data was lost} 30 0 {Invalid voltage (or current) range} 31 1 {This A/D board does not have programmable gain} 32 0 {Specified file name is not valid} 33 1 {Disk is full, could not complete operation} 34 1 {Board switch set to compatible mode - sampling speed may be limited} 35 0 {Pointer is not valid} 36 0 {Too many gains} 37 1 {Sample rate may be too fast for SINGLEIO mode} 38 0 {CONVERTDATA cannot be used with DMA I/O and BACKGROUND} 39 0 {Board does not support DTConnect option} 40 0 {CONTINUOUS can only be run with BACKGROUND} 41 0 {This function can not be used with this board} 42 0 {Digital port not configured correctly for requested operation} 43 1 {This digital port is not configurable (its an In/Out port)} 44 0 {Invalid digital port configuration} 45 0 {First point number is not valid} 46 0 {Attempted to read past the end of the file} 47 0 {This board does not have 8254 counter} 48 0 {This board does not have 9513 counter} 49 0 {Invalid trigger type} 50 0 {Trigger value greater than maximum allowed} 51 0 {Invalid error code} 52 0 {Invalid option specified for this function} 53 0 {Invalid pre-trigger count specified} 55 0 {Invalid FoutDivider value} 56 0 {Invalid FoutSource value} 57 0 {Invalid compare value} 58 0 {Invalid TimeOfDay value} 59 0 {Invalid GateInterval value} 60 0 {Invalid GateControl value} 61 0 {Invalid CounterEdge value} 62 0 {Invalid SpecialGate value} 63 0 {Invalid Reload value} 64 0 {Invalid RecycleMode value} 65 0 {Invalid BCDMode value} 66 0 {Invalid CountDirection value} 67 0 {Invalid OutputControl value} 68 0 {Invalid BitNum specified} 69 0 {None of the counter channels were enabled} 70 0 {An element of CntrControl array not set to DISABLED or ENABLED} 71 0 {Invalid EXP channel specified} 72 0 {Board set to wrong A/D range for reading thermocouples} 73 1 {Temperature input is out of range} 74 0 {Invalid temperature scale specified} 75 0 {Invalid error code} 76 0 {Specified board does not have chan/gain queue} 77 0 {Count must be > packet size to use Continuous mode} 78 1 {The FIFO went empty while doing output} 79 0 {Invalid memory mode specified} 80 1 {Measured frequency too high for selected gating interval} 81 0 {A CJC channel must be configured to make temperature measurements} 82 0 {Invalid ChipNum specified} 83 0 {The digital I/O on this board is not enabled} 84 1 {CONVERT option can not be used with 16 bit A/D converters} 85 0 {The EXTMEMORY option requires that a memory board be attached to A/D} 86 0 {No memory read/write allowed while DT transfer in progress} 87 0 {The specified board is not a memory board} 88 0 {The first chan in scan and number of chans must be even (0,2,4 etc)} 89 0 {Counter was not configured or initialized} 90 0 {This board does not have an 8536 counter chip} 91 1 {Board does not time A/D sampling. Collecting at fastest possible speed} 92 0 {Operation interrupted with CTRL-C key} 93 0 {No selector could be allocated} 94 1 {This board does not support Burst Mode} 95 0 {This function not available in Windows library} 96 1 {Board not configured for SIMULTANEOUS option} 97 0 {An even chan is in an odd slot in queue (or vice versa)} 98 1 {Sampling speed (>625 kHZ) to system memory MAY be too fast for counts > 1024} 99 0 {Selected board is not a RS-485 board} 100 0 {This function not available in DOS library} 101 1 {Bipolar and Unipolar ranges can not be used together in A/D queue} 102 0 {Sampling rate is too high for clock speed, change clock jumper on board} 103 1 {Calibration factors are invalid - Disabling software calibration} 104 0 {Invalid configuration information type specified} 105 0 {Invalid configuration item specified} 106 0 {Cannot access the PCMCIA board} 107 0 {Board does not support background operation} 108 1 {The string argument is too short for the string being returned} 109 0 {CONVERTDATA not allowed with EXTMEMORY option} 110 0 {Program error - bad values used in cbFromEngUnits or cbToEngUnits} 111 1 {Rates greater than 125 KHz must use on board 10 MHz clock} 112 1 {Desired sample rate is below hardware minimum} 113 0 {Invalid error code} 114 0 {More than one temperature sensor type defined for EXP-GP} 115 0 {No temperature sensor type defined for EXP-GP} 116 1 {Selected 12 bit board already returns converted data} 117 1 {CONTINUOUS mode cannot be used with EXTMEMORY} 118 1 {cbAConvertPretrigData called after cbAPretrig failed} 119 0 {Bad counter arg passed to cbCLoad} 120 0 {Low trigger threshold is greater than high threshold} 121 0 {NO PCM Card was found in the specified slot} 122 0 {Two identical PCM cards found. Please specify exact slot in Instacal.} 123 0 {Invalid sensor type selected in Instacal} 124 0 {Tried to delete a board that does not exist} 125 0 {Cannot find the board name file} 126 0 {Cannot find CB.CFG file} 127 0 {The CBUL.386 virtual device driver is not installed} 128 0 {The requested amount of Windows page-locked memory is not available} 129 0 {Not enough DOS memory available} 130 0 {Obsolete option specified for cbSetConfig/cbGetConfig} 131 0 {No registry entry for this PCMCIA board} 132 0 {CBUL32.SYS device driver is not installed} 133 0 {No DMA memory available to device driver} 134 0 {The selected interrupt is not available} 135 0 {This board does not have an LS7266 counter chip} 136 0 {Invalid Quadrature arg passed to cbC7266Config()} 137 0 {Invalid CountingMode arg passed to cbC7266Config()} 138 0 {Invalid DataEncoding arg passed to cbC7266Config()} 139 0 {Invalid IndexMode arg passed to cbC7266Config()} 140 0 {Invalid InvertIndex arg passed to cbC7266Config()} 141 0 {Invalid FlagPins arg passed to cbC7266Config()} 142 0 {This board does not support cbCStatus()} 143 0 {Gating may not be used when indexing is enabled} 144 0 {Indexing not allowed in non-quadrature mode} 145 0 {Temperature input has open connection} 146 0 {Count must be integer multiple of packet size for Continuous mode} 147 0 {Invalid callback function specified} 148 0 {MetraBus in use} 149 0 {MetraBus I/O card has no configured controller card} 150 0 {Invalid event type specified for this board} 151 0 {An event handler has already been enabled for this event type} 152 0 {Invalid event count specified} 153 0 {Unable to install event handler} 154 0 {Buffer is too small for operation} 155 0 {Invalid analog input mode (single-ended vs differential) specified} 156 0 {Invalid signal type specified} 157 0 {Invalid connection specified} 158 0 {Invalid index specified. If index>0, then you've reached end of internal list.} 160 0 {Count cannot be greater than the FIFO size for BURSTIO mode. Furthermore, Count must be integer multiple of number of channels in scan.} 161 0 {Device has stopped responding. Please check connections.} 163 0 {Required access or privilege not acquired for specified operation. Please check for other users of device and restart application.} 164 1 {Device unavailable at time of request. Please repeat operation.} 165 1 {Device is not ready to send data. Please repeat operation.} 168 1 {There was a network error. Please check network connections, repeat operation and/or restart application.} 169 0 {The specified bit is used for alarm.} 170 0 {One or more bits on the specified port are used for alarm.} 200 0 {Internal error occurred in library} 201 0 {DMA buffer could not be locked} 202 0 {DMA already controlled by another driver} 203 0 {Invalid Windows memory handle} 304 0 {Error reading from configuration file} 305 0 {Error writing to configuration file} 308 0 {Cannot open configuration file} 325 1 {Overflow of RTD conversion} 326 0 {PCI BIOS not present on the PC} 327 0 {Specified PCI board not detected} 328 0 {Specified PCI board not detected} 334 0 {Cannot install interrupt handler. IRQ already in use} 339 0 {Unable to access Card Information Structure} 343 0 {Specified USB board not detected} 344 0 {No more files in the directory} 345 0 {No file exists for the specified file number} 346 1 {The structure size is invalid} 347 0 {This file may not contain all of the data from the logging session because the logging session was not terminated properly} 348 0 {File is not a valid MCC binary file} 349 0 {Invalid delimiter specified for CSV file extension} 401 0 {PCMCIA Card and Socket Services Error - Invalid Adapter} 402 0 {PCMCIA Card and Socket Services Error - Invalid Attribute} 403 0 {PCMCIA Card and Socket Services Error - Invalid base system memory address} 404 0 {PCMCIA Card and Socket Services Error - Invalid EDC Generator} 406 0 {PCMCIA Card and Socket Services Error - Invalid IRQ Level} 407 0 {PCMCIA Card and Socket Services Error - Invalid Card Offset} 408 0 {PCMCIA Card and Socket Services Error - Invalid Page} 409 0 {PCMCIA Card and Socket Services Error - Incomplete read request} 410 0 {PCMCIA Card and Socket Services Error - Invalid Window size} 411 0 {PCMCIA Card and Socket Services Error - Invalid Socket} 413 0 {PCMCIA Card and Socket Services Error - Invalid Window type} 414 0 {PCMCIA Card and Socket Services Error - Invalid VCC level} 415 0 {PCMCIA Card and Socket Services Error - Invalid Vpp1 or Vpp2 level} 417 0 {PCMCIA Card and Socket Services Error - Invalid Windows} 418 0 {PCMCIA Card and Socket Services Error - Incomplete write request} 420 0 {PCMCIA Card and Socket Services Error - No card present} 421 0 {PCMCIA Card and Socket Services Error - Service not supported} 422 0 {PCMCIA Card and Socket Services Error - Invalid Mode} 423 0 {PCMCIA Card and Socket Services Error - Invalid Speed} 424 0 {PCMCIA Card and Socket Services Error - Busy} 425 0 {PCMCIA Card and Socket Services Error - Undefined Error} 426 0 {PCMCIA Card and Socket Services Error - Write protect failure} 427 0 {PCMCIA Card and Socket Services Error - Argument length invalid} 428 0 {PCMCIA Card and Socket Services Error - Argument invalid} 429 0 {PCMCIA Card and Socket Services Error - Configuration has been locked} 430 0 {PCMCIA Card and Socket Services Error - Resource in use} 431 0 {PCMCIA Card and Socket Services Error - No more of the requested items available} 432 0 {PCMCIA Card and Socket Services Error - Card services is out of resources} 433 0 {PCMCIA Card and Socket Services Error - Invalid handle} 434 0 {PCMCIA Card and Socket Services Error - Client Version Not Supported} 501 0 {Invalid DOS function number specified - *** Internal Error} 502 0 {Cannot find file} 503 0 {Cannot find path} 504 0 {No DOS handles left} 505 0 {File Access denied} 506 0 {Invalid handle - *** Internal Error} 507 0 {DOS has no more memory available} 515 0 {Invalid disk drive} 518 0 {Too many disk files} 519 0 {Disk is write protected} 521 0 {Disk drive is not ready} 525 0 {DOS seek error} 529 0 {DOS write error} 530 0 {DOS read error} 531 0 {DOS general fault} 603 0 {Cannot enable interrupt. IRQ already in use.} 605 0 {Cannot disable interrupts} 606 0 {Insufficient memory to page lock data buffer} 630 0 {PCM card not detected} 801 0 {The number of elements in the gain array must equal the number of channels in the scan} 802 0 {The length of dimension 0 in the data array must equal the number of channels in the scan} -2 {}Download Driver Pack
After your driver has been downloaded, follow these simple steps to install it.
Expand the archive file (if the download file is in zip or rar format).
If the expanded file has an .exe extension, double click it and follow the installation instructions.
Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.
Find the device and model you want to update in the device list.
Double-click on it to open the Properties dialog box.
From the Properties dialog box, select the Driver tab.
Click the Update Driver button, then follow the instructions.
Very important: You must reboot your system to ensure that any driver updates have taken effect.
For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.