V34ICP.TXT Driver File Contents (Apache_V34iv_sp.exe)

                        

                            Apache Cyberpower Modem Series
                            ===============================
                                    AT COMMMAND SET
                                    ===============
                           

Note: USERS SHOULD BE AWARE THAT NOT ALL AT COMMANDS ARE INCLUDED AND NOT
      ALL COMMANDS ARE APPLICABLE TO ALL MODEM CARDS.
______________________________________________________________________________
Table of Contents - Cirrus Logic Chip Set

1**Extended AT Command Set

2**2**S-Registers

______________________________________________________________________________
1**Extended AT Command Set****************************************************

AT Commands

A/      Re-execute previous command.

A       Answer.

Bn      Select CCITT or Bell standard
        B0      ITU-T V.22 at 1200 bps and ITU-T V.21 at 300 bps
        B1      Bell operation at 300 or 1200 b/s (default)
        B2      ITU-T V.23 75/1200.
        B3      ITU-T V.23 1200/75.

Cn      Carrier control. The only valid parameter is 1.

D       Dial
	0-9     Dial DTMF digits 0 to 9.
	*       Dial the "star" symbol (tone dialing only).
	#       Dial the "pound" symbol (tone dialing only).
	A-D     Dial DTMF digits A, B, C, and D. Some countries may
		prohibit sending these digits during dialing.
	P       Select pulse dialing.
	R       Reverse Originate Mode; forces originate mode after
		dialing. Used after all other characters in dial string. 
	S=r     Dial stored number r (see &Z for storing numbers). 
	T       Select tone dialing.

        W       Wait for dial tone- causes the modem to look for dial tone
                for a specified amount of time.  If dial tone or the amount
                of time specified by the S-register, S6, time out, the modem
                processes the next command in the dial string. If a busy
                signal is detected, the modem responds to the DTE with a
                busy response code and then goes into off-line command mode.
                
        !       Flash: go on-hook cause the modem to go on-hook for 0.75 sec.

        @       Wait for Quiet Answer-causes the modem to wait for specified
                amount of time (S7) followed by 5 sec of silence before
                processing the next dial modifier.

	,       Pause. The modem pauses for a time specified by S8
		before dialing the following digits. Most often used
		when dialing an outside line through a PBX.

        ;       Retune to Idle State-causes the modem to enter online
                command mode without initiating a data modem hangshake
                (used for phone directory autodialers)

       
               
       <space>- () Innored by modem-these fourcharacters are ignored by
                   the modem.  Spaces also may be included in the dial
                   string to separate area codes and numbers.

En      Command echo
	E0      Disables command echo. 
        E1      Enables command echo . 

Fn      On-line Echo
	The command is used to select whether the modem echoes data back to
	the host during on-line data mode.
	F0      Echo enabled.
        F1      Echo disabled.

Hn      Disconnect (hang up)
        H0      Hang Up the telephone line.
        H1      Pick Up the telephone line.

In      Identification
        I0      Product code.
        I1      Reports Modem chip firmware version.
	I2      Verify ROM checksum.
	I3      Device set name.
        I4      Reserved.
	I5      Reserved for Modem chip hardware configuration.
	I6      Country Code.
	I7      Board Manufacturer Firmware version #.
	I8      Modem Firmware Features.
	I10     Modem board configuration - bits set by board manufacturer.
	I11     Modem board configuration - bits set by board manufacturer.
	I14     SAFE device.
	I20     Cirrus Silicon version.
	I21     Cirrus Firmware version.
	I22     Cirrus Manufacturer Name.
	I23     Cirrus Product Model.


Ln      Speaker volume
	L0      Off or low volume.
	L1      Low volume (default).
	L2      Medium volume.
	L3      High volume.

Mn      Speaker control
	M0      Speaker is always off.
	M1      Speaker is on until carrier is detected (default).
	M2      Speaker is always on.
	M3      Speaker is off during dialing and on until carrier.

Nn    Select Data Rate Handshake
        N0      Handshake only at DTE-to-modem data rate
        N1      When originating or answering, begin handshaking at the
                modulation data rate.  If the remote modem does not support
                the specified modulation data rate, fall down in data rate
                or modulation to the highest compatible data rate.

On      Go on-line : This command cause the modem to return back to online
                     data mode from online command mode

        O0      Return modem to data mode
        O1      Begins an equalizer retrain sequence, then returns to data
                mode.

Qn      Quiet results codes control
	Q0      Enables result codes to the DTE (default).
	Q1      Disables result codes to the DTE.

Sr      Read or write to S-register r
	r       Establishes S-register r as the default register.
	r=n     Sets S-register r to the value n.
	r?      Reports the value of S-register r.

Vn      Result code form
        V0      Enables short-form (Numeric form) result codes.
	V1      Enables long-form (verbose) result codes (default). 

Wn      Rsponse Code Data Rate: This command selects whether the modem
        sends the DTE independent modem connection result codes for speed
        ,error control protocol, or data compression.

        n=0     CONNECT result code reports DTE speed.
        n=1     CONNECT result code reports DTE speed.
        n=2     CONNECT result code reports DCE speed.
        n=3     CONNECT result code reports DTE data rate, modulation mode,
                error correction, data compression.

        For example: CONNECT 115200/V34/LAMP/V42B/TX=28800/RX=28800

        n=4     CONNECT result code reports DTE protocol.

        For example: PROTOCOL: LAMP
                     COMPRESSION:V42B
                     CONNECT 33,600

Xn      Result codes type

        X0      Enables result codes 0-4; disables detection of busy
                and dial tone detection.
        X1      Enables result codes 0-5,10 and above; disables
                detection of busy and dial tone detection.
        X2      Enables result codes 0-6,10 and above; disables busy
                detection and enables dial tone detection.
        X3      Enables result codes 0-7,10 and above; enables busy
                detection and  dial tone detection.
        X4      Enables result codes 0-7 and 10 and above; enables
                busy and dial tone detection.

Yn      Long space disconnect

        Y0      Disables long space disconnect (default).
	Y1      Enables long space disconnect. 

Zn      Recall Stored Profile
        Z0      Resets modem and recalls user profile 0
        Z1      Resets modem and recalls user profile 1
        
AT& Commands

&Cn     Data Carrier Detect (DCD) option
	&C0     DCD remains ON at all times (default).
	&C1     DCD follows the state of the carrier.

&Dn     DTR option
        &D0     In async mode, modem ignores DTR
        &D1     Modem switches from data mode to command mode when an
                on-to-off transition of DTR
        &D2     When DTR switches off, the modem goes on-hook and disables
                auto-answer mode;when DTR switches on, auto-answer is enable.
        &D3     Turning off DTR re-initializes the modem and resets values
                except UjART registers.

&F    Restore factory configuration (profile).

&Gn     Select guard tone
	&G0     Disables guard tone (default).
	&G1     Enables 550-Hz guard tone.
	&G2     Enables 1800-Hz guard tone.

&Jn     Auxiliary relay control
        &J0     Auxiliary relay never operated
        &J1     Activates auxiliary relay when modem is off-hook.


&Kn     Select serial port flow control
        &K0     Disable flow control
        &K3     Bidirectional hardware flow control
        &K4     XON/XOFF software flow control

&Mn     Asynchronous/synchronous mode selection
	Determines the DTR operating mode. The modem treats the &M command as
        a subset of the &Q command.
	&M0     Direct asynchronous operation. (Only supports Asynchronous.)

&Pn     Select pulse dial make/break ratio
        &P0     39/61 make/break ratio at 10 pulses per second (default).
        &P1     33/67 make/break ratio at 10 pps

&Qn   Asynchronous or synchronous mode
        &Q0     Asynchronous operation only

&Sn     DSR Option
	&S0     DSR remains ON at all times (default).
	&S1     DSR becomes active after answer tone has been detected and
		inactive after carrier has been lost.

&Tn     Test and diagnostics
	&T0     Terminates test in progress (default).
	&T1     Initiates local analog loopback.
	&T3     Initiates local digital loopback.
	&T4     Enables digital loopback acknowledgment for remote request.
	&T5     Disables digital loopback acknowledgment for remote request.
	&T6     Requests a remote digital loopback (RDL).e start of the test.
	&T7     Requests a remote digital loopback (RDL) with self-test.
	&T8     Initiates local analog loopback, with self-test.

&Un   Disable Trellis coding
	&U0     Enable Trellis mod with QAM mod as a fallback (default).
	&U1     Disable (QAM modulation only).

&Vn   Display current configuration and stored profiles
	&V0     Display profile #0 (default).
	&V1     Display profile #1.
	&V3     Relay and general purpose input/outpt status.

&Wn     Store current configuration
	&W0     Store the current configuration as profile 0 (default).
	&W1     Store the current configuration as profile 1.

&Yn     Designate a default reset profile
	&Y0     The modem uses profile 0 (default).
	&Y1     The modem uses profile 1.

&Zn=x   Store telephone number. Recall using ATDS=n.
          n = 0-3, x = dial string (up to 30 digits). 

%En     Auto-retrain control
        %E0     Disables auto-retrain
        %E1     Enables auto-retrain

%Gn     Rate renegotiation
        %G0     Disabled
        %G1     Enabled

-Cn     Generate data modem calling tone
        -C0     Calling tone disabled
        -C1     1300-Hz Calling tone Enabled
        -C2     V.8 calling tone and 1300-Hz calling tone

+GMI?   Identify modem manufacturer
+GMM?   Identify product model
+GMR?   Identify product revision
+MS=m   Modulation selections

%An     Set auto-reliable fallback character

%Cn     MNP5 data compression control
        %C0     No compression
        %C1     Enables NMP5 data compression
        

AT\ Commands

\An   MNP Block Size
	\A0     Max 64 characters.
	\A1     Max 128 characters.
	\A2     Max 192 characters.
	\A3     Max 256 characters (default).

\Bn   Transmit Break
	n = 0-9 (100 msec break units to send).

\Cn   Set Auto-reliable Buffer (requires Microcom license)
	In auto-reliable mode (\N3), this command determines the fallback
	method and enables data buffering.
	\C0     Does not buffer data (default).
	\C1     Buffers data for four seconds until 200 characters have been
		buffered, then switches to reliable mode.
        \C2     Doesnot buffer data. Connect non-V.42 modems to V.42 modem

\Gn     Modem-to-modem flow control (XON/XOFF)
	\G0     Disables modem-to-modem XON/XOFF flow control (default). 
	\G1     Enables modem-to-modem XON/XOFF flow control.

\Jn     Enable DTE auto rate adjustment
	\J0     Disable adjustment of DTE speed to match line speed (default).
	\J1     Enable adjustment of DTE speed to match line speed.

\Kn     Break control
	Determines how modem handles a break. If the break is received from
	the DTE while the modem is in data mode:
	\K0     Enter command mode; no break sent to remote modem.
	\K1     Clear data buffers and send break to remote modem.
	\K2     Same as 0.
	\K3     Send break to remote modem immediately.
	\K4     Same as 0.
	\K5     Send break to remote modem in sequence with transmitted data
		(default).
	If the break is received from the DTE while the modem is in command
	mode:
	\K0     Clear data buffers and send break to remote modem.
	\K1     Same as 0.
	\K2     Send break to remote modem immediately.
	\K3     Same as 2.
	\K4     Send break to remote modem in sequence with data.
	\K5     Same as 4 (default). 
      If the break is received from the serial port during a connection while
	in direct mode:
	\K0     Immediately send break and enter command state.
	\K1     Immediately send break through.
	\K2     Same as 0.
	\K3     Same as 1.
	\K4     Same as 0.
	\K5     Same as 1 (default).
	If the break is received from a remote modem during a non-error-
	corrected connection:
	\K0     Clears data buffers and sends break to the DTE.
	\K1     Same as 0.
	\K2     Send a break immediately to DTE.
	\K3     Same as 2.
	\K4     Send break to DTE in sequence with received data.
	\K5     Same as 4 (default). 

\Nn     Operating mode
	\N0     Normal speed-buffered mode; disables error-correction mode.
	\N1     Direct mode; no data compression, error-corection, or speed
		buffering.
	\N2     MNP Reliable mode. The modem first attempts an MNP connection.
		Failure to do so results in the modem hanging up.
	\N3     V.42 Auto-reliable mode. If V.42 mode selected, then MNP and
		LAPM will be attempted, otherwise only LAPM will be attempted
		(default).
	\N4     LAPM error-correction mode. Failure to make a LAPM error-
		correction connection results in the modem hanging up.

\O    Originate Reliable Link
	In normal mode, the modem will attempt to originate an MNP link.

\Qn   Set Serial Port Flow Control
	\Q0     Disables flow control.
	\Q1     XON/XOFF software flow control.
	\Q2     Unidirectional hardware flow control.
	\Q3     Bidirectional hardware flow control (default).

\Tn   Set Inactivity Timer
        n=0     Disabled
        n=0-90  Length in minutes

\U    Set Auto-reliable Link
	In normal mode (\N0), the modem attempts to answer an MNP link
	request, regardless of the physical connection. The remote modem
	must be in Originate mode (\O).

\Xn   Set XON/XOFF Pass-through
	\X0     Processes flow control characters (default).
	\X1     Processes flow control characters and passes them through
		to the local or remote host.

\Y    Switch to Reliable Mode

\Z    Switch to Normal Mode



AT- Commands


-Jn   Set V.42 Detect Phase
	-J0     Disables the V.42 detect phase.
	-J1     Enables the V.42 detect phase (default).






AT" Commands

"Hn   V.42 bis Compression Control
	"H0     Disables V.42 bis.
	"H1     Enables V.42 bis only when transmiting data.
	"H2     Enalbes V.42 bis only when receiving data.
	"H3     Enalbes V.42 bis during transmission and reception.

"On   V.42 bis String Length
	n = 6-250 (number of characters; default = 32).


Caller ID Command

+VCID=n 0       Caller ID Selection:

                n=0-2
                n=0     Disables Caller ID
                n=1     Enables Caller ID with formatted presentation to
                        the DTE.  The modem presents the data items in a
                        <Tag><Value>pair format.  The expected pairs are
                        data,time, caller code (phone number),and name.

                n=2     Enables Caller ID with unformatted presentation
                        to the DTE. The modem presents the entire packet
                        of information, excluding the leading U's, in
                        ASCII printable hex numbers.

                Note:   If S0=1 (auto-answer mode) and Caller ID is enabled
                        in data modem mode, then the modem answers only after
                        the second ring signal.


Fax: Apache Cyberpower Modem Series Fax Class I.







______________________________________________________________________________
______________________________________________________________________________
3**S-Registers****************************************************************

Hayes-compatible modems store most of their configuration information in
8-bit status registers, or S-registers. For instance, S-register 7 (S7 for
short) determines the length of time the modem waits for carrier before going
back on-hook. You can modify many features of the modem's operation by
writing directly to these registers, using AT commands provided for this
purpose.

NOTE: Many AT commands that do not expressly invoke S-registers nonetheless
write to them. For instance, the Fn command, which selects line modulation,
writes to S31, and the &Tn test commands write to S16.

The table below shows a summary of your modem's S-registers. Section 4 contains a detailed description of bit-mapped and coded S-registers.

S-registers are volatile and are not preserved after a power-off or reset.
However, the contents of the registers marked * in the table can be saved
permanently in nonvolatile RAM as part of a configuration profile, using the
&Wn command. The S-register values of factory configuration profiles are
stored permanently in the modem's ROM.

You can also configure most communications programs to issue a series of AT
commands, including those that write to S-registers, automatically as part
of a macro or command string associated with specified operations.

Writing to S-Registers

The command to write the value n to S-register r is

	ATr=n<ENTER>

Since the S-registers hold 8 bits, n must be an integer from 0 to 255.
Although for many S-registers the value of the separate bits is meaningful,
you cannot write directly to individual bits, and you must always enter
values as decimal numbers.

S-Register Summary

No.     Function                        Range    Units           Default
  *0    Rings to auto-answer            0-255    rings           0
   1    Ring counter                    0-255    rings           0
  *2    Escape character                0-127    ASCII           43
   3    Carriage-return character       0-127    ASCII           13
   4    Line-feed character             0-127    ASCII           10
   5    Backspace character             0-32,127 ASCII           8
  *6    Wait time for dial tone         2-255    sec             2
  *7    Wait time for carrier           1-255    sec             60
  *8    Pause for dial delay modifier   0-255    sec             2
  *9    Carrier detect response time    1-255    0.1 sec         6
 *10    Carrier loss disconnect time    1-255    0.1 sec         14
 *11    DTMF tone duration              50-255   0.001 s         70
 *12    Escape code guard time          0-255    0.02 s          50
 *14    General bit-mapped options      _        _               170
 *16    Test mode bit-mapped options    _        _               0
 *18    Test timer                      0-255    sec             0
 *21    V.21/general bit-mapped options _        _               48
 *22    General bit-mapped options      _        _               118
 *23    General bit-mapped options      _        _               none
 *25    Delay to DTR off                0-255    0.01 sec        5

 *27    General bit-mapped options      _        _               64_
 *30    Disconnect inactivity timer     0-255     min              0
  31    General bit-mapped options      _        _               none_
 *33    Sleep mode time                 0-90     sec             10
 *37    Maximum line speed attempted    0-19     _               0

*Can be saved as part of a configuration profile.

For example, S0 determines the number of rings before the modem auto-answers.
The default is 0. To change the number of rings to 1, give the command

	ATS0=1<ENTER>

S7 determines the time that the modem waits for carrier. The default is 50,
in units of seconds. To change this value to 60 seconds, give the command

	ATS7=60<ENTER>

Pointing to a Default Register

The command ATSr points to S-register r as the default register. When this
has been done, AT=n writes the value n to S-register r.

The command to change the number of rings before auto-answering to 1 could
therefore also be given as

	ATS0<ENTER>
	AT=1<ENTER>

Reading S-Registers

The command

	ATSr?<ENTER>

reports the value of S-register r. For instance:

	ATS0?<ENTER>
	000
	OK

reads the value of S0. Like other AT commands, multiple read commands can be
given together:

	ATS3?S5?<ENTER>
	013
	008
	OK
______________________________________________________________________________
4**Bit-mapped and Coded S-Registers*******************************************

This section describes the special bit-mapped and coded S-registers not covered in detail in the previous section.

S14     General bit-mapped options
	Bit 0   Reserved. 
	Bit 1   Command echo (En)
		0 = Disabled (E0)
		1 = Enabled (E1) (default)
	Bit 2   Quiet mode (Qn)
		0 = Send result codes (Q0) (default)
		1 = Do not send result codes (Q1)
	Bit 3   Result codes (Vn)
		0 = Numeric (V0) 
		1 = Verbose (V1) (default)
	Bit 4   Reserved.
	Bit 5   Tone (T)/Pulse (P)
		0 = Tone (T)
		1 = Pulse (P) (default)
	Bit 6   Reserved.
	Bit 7   Originate/Answer
		0 = Answer
		1 = Originate (default)

S16     General bit-mapped test options
	Bit 0   Local analog loopback
		0 = Disabled (default)
		1 = Enabled (&T1)
	Bit 1   Reserved.
	Bit 2   Local digital loopback
		0 = Disabled (default)
		1 = Enabled (&T3)
	Bit 3   Remote digital loopback (RDL) status
		0 = Modem not in RDL (default)
		1 = RDL in progress
	Bit 4   RDL requested (&T6)
		0 = RDL not requested (default)
		1 = RDL requested (&T6)
	Bit 5   RDL with self-test
		0 = Disabled (default)
		1 = Enabled (&T7)
	Bit 6   Local analog loopback (LAL) with self-test
		0 = Disabled (default)
		1 = Enabled (&T8)
	Bit 7   Reserved

S21     V.21/general bit-mapped options
	Bit 0   Set by &Jn command but ignored otherwise.
		0 = &J0 (default)
		1 = &J1
	Bit 1   Reserved
	Bit 2   Reserved
	Bit 3,4 DTR behavior (&Dn)
		0 = &D0 selected (default)
		1 = &D1 selected
		2 = &D2 selected
		3 = &D3 selected
	Bit 5   RLSD (DCD) behavior (&Cn)
		0 = &C0 selected
		1 = &C1 selected (default)
	Bit 6   DSR behavior (&Sn)
		0 = &S0 selected (default)
		1 = &S1 selected
	Bit 7   Long space disconnect (Yn)
		0 = Y0 (default)
		1 = Y1

S22     Speaker/results bit-mapped options
	Bit 0,1 Speaker volume (Ln)
		0 = Off (L0)
		1 = Low (L1)
		2 = Medium (L2) (default)
		3 = High (L3)
	Bit 2,3 Speaker control (Mn)
		0 = Disabled (M0)
		1 = Off on carrier (M1) (default)
		2 = Always on (M2)
		3 = On during handshake (M3)
	Bit 4,5,6 Limit result codes (Xn)
		0=X0, 4=X1, 5=X2, 6=X3, 7=X4 (default)
	Bit 7   0 = Pulse ratio 39/61 (&P0)(default)
		1 = Pulse ratio 33/67 (&P1)

S23     General bit-mapped options
	Bit 0   Grant remote digital loopback (RDL)
		0 = RDL not allowed (&T5)
		1 = RDL allowed (&T4) (default)
	Bit 1,2,3 Assumed DTE rate
		0 = 0-300 b/s
		1 = 1200 b/s
		2 = 2400 b/s
		3 = 4800 b/s
		4 = 7200 b/s
		5 = 9600 b/s
		6 = 19200 b/s
		7 = >38400 b/s
	Bit 4,5 Assumed DTE parity
		0 = even (default)
		1 = space/none
		2 = odd
		3 = mark
	Bit 6,7 Guard tone (&Gn)
		0 = None (&G0)
		1 = None (&G1)
		2 = 1800 Hz (&G2)
		3 = Reserved

S27     Bit-mapped options
	  Bits 0-3 reserved for future expansion
		0 = &Q0 (default)
	Bit 4,5 Internal clock select (&Xn)
		0 = Internal clock (&X0) (default)
		1 = External clock (&X1)
		2 = Slave clock (&X2)
	Bit 6,7 CCITT/Bell mode select (Bn)
		0 = CCITT mode (B0) (default)
		1 = Bell mode (B1)
		2 = (B2)
		3 = (B3)

S31     Bit-mapped options    (S31 not present in 144C or 144D modems)
	Bit 0   0 = (N0)
		1 = (N1) (default)
	Bit 1   0 = (&U0)
		1 = (&U1)
	Bit 2   Reserved
	Bit 3   0 = (-C0) (default)
		1 = (-C1)
	Bit 4   0 = (%E0) (default)
		1 = (%E1)
	Bit 5   0 = (%G0)
		1 = (%G1)

S33     10      Sleep mode timer: S33 determines when the modem enters sleep
                or power-down mode.  When enabled (S33 Not equal to 0), the
                controller enters sleep mode whenever the modem has been
                inactive for a user-programmable time delay (S33).  The modem
                is considered to be in an inactive state when:

                1)      No internal processing is being performed;
                2)      No activity occurs between the host and the modem within
                        a specified time period;
                3)      The modem is off-line

                The modem exits sleep mode whenever the host reads or writes to
                the modem or when a ring signal is detected.

                Sleep mode is disabled by setting S33 to '0'.
                Rang: 0-90 seconds

S37     0       Maximun Line Speed Attempted:

                This S register selects the maximum line speed allowedable
                (that is , the modem attempts to connect at this speed or
                fallls back to a lower speed). Settings for Bn, +MS=m, Nn and S37
                determine the allowable modem connections. S37 provides the same
                information as the +MS=m <max rate>parameter.  Changing the +MS=m
                <max rate> to 0 sets s37 to 0.  Note that S37 has no effect during
                V32 bis retraining/rate negotiation .

                n=0-19
                n=0     DTTE rate
                n=1     Reserved
                n=2     Reserved
                n=3     300
                n=4     Reserved
                n=5     1200
                n=6     2400
                n=7     4800
                n=8     7200
                n=9     9600
                n=10    12,200
                n=11    14,400
                n=12    16,800
                n=13    19,200
                n=14    21,600
                n=15    24,000
                n=16    26,400
                n=17    28,800
                n=18    31,200 (reserved for future products)
                n=19    33,600 (reserved for future products)

______________________________________________________________________________



     End
     ===



Download Driver Pack

How To Update Drivers Manually

After your driver has been downloaded, follow these simple steps to install it.

  • Expand the archive file (if the download file is in zip or rar format).

  • If the expanded file has an .exe extension, double click it and follow the installation instructions.

  • Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.

  • Find the device and model you want to update in the device list.

  • Double-click on it to open the Properties dialog box.

  • From the Properties dialog box, select the Driver tab.

  • Click the Update Driver button, then follow the instructions.

Very important: You must reboot your system to ensure that any driver updates have taken effect.

For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.

server: web4, load: 0.91