; SPEED.INF ; ; Copyright (c) 2003 Perle Systems Limited ; [version] Signature = "$Windows NT$" Class = MultiPortSerial ClassGUID = {50906CB8-BA12-11D1-BF5D-0000F805F530} Provider = %Perle_Systems% CatalogFile.ntx86 = Speed.cat ;------------------------------------------------------------------------ ; Driver Package Version Information ; ; DriverVer = mm/dd/yyyy, [a.b.c.d] ;------------------------------------------------------------------------ DriverVer = 09/07/2004, 2.0.0.0002 ;******************************************************************************************* ; Control Flags ;******************************************************************************************* [ControlFlags] ; SPEED and SPEED+ Adapters ExcludeFromSelect = \ PCI\VEN_1415&DEV_9501&SUBSYS_A00211CB, \ PCI\VEN_1415&DEV_9501&SUBSYS_A00411CB, \ PCI\VEN_1415&DEV_9510&SUBSYS_000011CB, \ PCI\VEN_11CB&DEV_9501&SUBSYS_A00211CB, \ PCI\VEN_11CB&DEV_9511&SUBSYS_A00111CB, \ PCI\VEN_11CB&DEV_9501&SUBSYS_A00411CB, \ PCI\VEN_11CB&DEV_9511&SUBSYS_A00011CB ; FAST Adapters ExcludeFromSelect = \ PCI\VEN_10B5&DEV_9050&SUBSYS_003112E0, \ PCI\VEN_10B5&DEV_9050&SUBSYS_002112E0, \ PCI\VEN_10B5&DEV_9050&SUBSYS_001112E0, \ PCI\VEN_10B5&DEV_9050&SUBSYS_004112E0 ; PCI RAS Adapters ExcludeFromSelect = \ PCI\VEN_10B5&DEV_9050&SUBSYS_F001124D, \ PCI\VEN_10B5&DEV_9050&SUBSYS_F010124D, \ PCI\VEN_10B5&DEV_9030&SUBSYS_F001155F, \ PCI\VEN_10B5&DEV_9030&SUBSYS_F010155F ; UltraPort Adapters ExcludeFromSelect = \ PCI\VEN_10B5&DEV_9030&SUBSYS_0061155F, \ PCI\VEN_10B5&DEV_9030&SUBSYS_0011155F, \ PCI\VEN_10B5&DEV_9030&SUBSYS_0031155F, \ PCI\VEN_10B5&DEV_9030&SUBSYS_0021155F, \ PCI\VEN_10B5&DEV_9030&SUBSYS_0041155F, \ PCI\VEN_10B5&DEV_9030&SUBSYS_0051155F, \ PCI\VEN_13A8&DEV_0152&SUBSYS_0261155F, \ PCI\VEN_13A8&DEV_0152&SUBSYS_0211155F, \ PCI\VEN_13A8&DEV_0154&SUBSYS_0231155F, \ PCI\VEN_13A8&DEV_0158&SUBSYS_0221155F, \ PCI\VEN_10B5&DEV_9030&SUBSYS_0241155F, \ PCI\VEN_13A8&DEV_0158&SUBSYS_0251155F ;******************************************************************************************* ; Manufacturer ;******************************************************************************************* [Manufacturer] %Perle_Systems% = Perle ;******************************************************************************************* ; Perle Multi-port Adapters ;******************************************************************************************* [Perle] ; DisplayName Section DeviceID ; ----------- ------- -------- ; SPEED and SPEED+ Adapters %SPD2_PCI.DeviceDesc% = SPEED_PCI, PCI\VEN_1415&DEV_9501&SUBSYS_A00211CB %SPD4_PCI.DeviceDesc% = SPEED_PCI, PCI\VEN_1415&DEV_9501&SUBSYS_A00411CB %SPD2AND4LB_PCI.DeviceDesc% = SPEED_PCI, PCI\VEN_1415&DEV_9510&SUBSYS_000011CB %SPD2P_PCI.DeviceDesc% = SPEEDPLUS_PCI, PCI\VEN_11CB&DEV_9501&SUBSYS_A00211CB %SPD2PLB_PCI.DeviceDesc% = SPEEDPLUS_PCI, PCI\VEN_11CB&DEV_9511&SUBSYS_A00111CB %SPD4P_PCI.DeviceDesc% = SPEEDPLUS_PCI, PCI\VEN_11CB&DEV_9501&SUBSYS_A00411CB %SPD4PLB_PCI.DeviceDesc% = SPEEDPLUS_PCI, PCI\VEN_11CB&DEV_9511&SUBSYS_A00011CB ; FAST Adapters %FAST4_PCI.DeviceDesc% = FAST_PCI, PCI\VEN_10B5&DEV_9050&SUBSYS_003112E0 %FAST8_PCI.DeviceDesc% = FAST_PCI, PCI\VEN_10B5&DEV_9050&SUBSYS_002112E0 %FAST16_PCI.DeviceDesc% = FAST_PCI, PCI\VEN_10B5&DEV_9050&SUBSYS_001112E0 %FAST16FMC_PCI.DeviceDesc% = FAST_PCI, PCI\VEN_10B5&DEV_9050&SUBSYS_004112E0 %ATFAST4_ISA.DeviceDesc% = FAST4_ISA, AT_FAST4 %ATFAST8_ISA.DeviceDesc% = FAST8_ISA, AT_FAST8 %ATFAST16_ISA.DeviceDesc% = FAST16_ISA, AT_FAST16 ; PCI-RAS Adapters %RAS4_PCI.DeviceDesc% = RAS_PCI, PCI\VEN_10B5&DEV_9050&SUBSYS_F001124D %RAS8_PCI.DeviceDesc% = RAS_PCI, PCI\VEN_10B5&DEV_9050&SUBSYS_F010124D %RAS4V92_PCI.DeviceDesc% = RASV92_PCI, PCI\VEN_10B5&DEV_9030&SUBSYS_F001155F %RAS8V92_PCI.DeviceDesc% = RASV92_PCI, PCI\VEN_10B5&DEV_9030&SUBSYS_F010155F ; UltraPort & UltraPort SI PCI Adapters %ULTRAPORT1_PCI.DeviceDesc% = ULTRAPORT_PCI, PCI\VEN_10B5&DEV_9030&SUBSYS_0061155F %ULTRAPORT2_PCI.DeviceDesc% = ULTRAPORT_PCI, PCI\VEN_10B5&DEV_9030&SUBSYS_0011155F %ULTRAPORT4_PCI.DeviceDesc% = ULTRAPORT_PCI, PCI\VEN_10B5&DEV_9030&SUBSYS_0031155F %ULTRAPORT8_PCI.DeviceDesc% = ULTRAPORT_PCI, PCI\VEN_10B5&DEV_9030&SUBSYS_0021155F %ULTRAPORT16_PCI.DeviceDesc% = ULTRAPORT_PCI, PCI\VEN_10B5&DEV_9030&SUBSYS_0041155F %ULTRAPORT8I_PCI.DeviceDesc% = ULTRAPORT_PCI, PCI\VEN_10B5&DEV_9030&SUBSYS_0051155F %ULTRAPORT1SI_PCI.DeviceDesc% = ULTRAPORTSI_PCI, PCI\VEN_13A8&DEV_0152&SUBSYS_0261155F %ULTRAPORT2SI_PCI.DeviceDesc% = ULTRAPORTSI_PCI, PCI\VEN_13A8&DEV_0152&SUBSYS_0211155F %ULTRAPORT4SI_PCI.DeviceDesc% = ULTRAPORTSI_PCI, PCI\VEN_13A8&DEV_0154&SUBSYS_0231155F %ULTRAPORT8SI_PCI.DeviceDesc% = ULTRAPORTSI_PCI, PCI\VEN_13A8&DEV_0158&SUBSYS_0221155F %ULTRAPORT16SI_PCI.DeviceDesc% = ULTRAPORTSI_PCI, PCI\VEN_10B5&DEV_9030&SUBSYS_0241155F %ULTRAPORT8ISI_PCI.DeviceDesc% = ULTRAPORTSI_PCI, PCI\VEN_13A8&DEV_0158&SUBSYS_0251155F ;******************************************************************************************* ; Perle Multi-port Adapters ;******************************************************************************************* ;------------------------------------------------------------------------------------------- ; SPEED and SPEED+ Adapters ; [SPEED_PCI.ntx86] CopyFiles = SPEED.CopyFiles, SPEED_DLL.CopyFiles AddReg = SPEED_DLL.AddReg CopyINF = %PortsINF% [SPEED_PCI.ntx86.CoInstallers] CopyFiles = CoCopyINF_DLL.CopyFiles, SpxUpChk_DLL.CopyFiles AddReg = SPEED.CoInstallers.Reg [SPEED_PCI.ntx86.HW] AddReg = SPEED_PCI.HW.AddReg [SPEED_PCI.ntx86.Services] AddService = %SPEED.ServiceName%, 0x00000002, SPEED.Service, SPEED.EventLog [SPEEDPLUS_PCI.ntx86] CopyFiles = SPEED.CopyFiles, SPEED_DLL.CopyFiles AddReg = SPEED_DLL.AddReg CopyINF = %PortsINF% [SPEEDPLUS_PCI.ntx86.CoInstallers] CopyFiles = CoCopyINF_DLL.CopyFiles, SpxUpChk_DLL.CopyFiles AddReg = SPEED.CoInstallers.Reg [SPEEDPLUS_PCI.ntx86.HW] AddReg = SPEEDPLUS_PCI.HW.AddReg [SPEEDPLUS_PCI.ntx86.Services] AddService = %SPEED.ServiceName%, 0x00000002, SPEED.Service, SPEED.EventLog ;------------------------------------------------------------------------------------------- ; FAST cards ; [FAST_PCI.ntx86] CopyFiles = SPEED.CopyFiles, SPEED_DLL.CopyFiles AddReg = SPEED_DLL.AddReg CopyINF = %PortsINF% [FAST_PCI.ntx86.CoInstallers] CopyFiles = CoCopyINF_DLL.CopyFiles AddReg = CoCopyINF.CoInstaller.Reg [FAST_PCI.ntx86.HW] AddReg = FAST_PCI.HW.AddReg [FAST_PCI.ntx86.Services] AddService = %SPEED.ServiceName%, 0x00000002, SPEED.Service, SPEED.EventLog [FAST4_ISA.ntx86] CopyFiles = SPEED.CopyFiles, SPEED_DLL.CopyFiles AddReg = SPEED_DLL.AddReg LogConfig = FAST4_ISA.LogConfig CopyINF = %PortsINF% [FAST4_ISA.ntx86.CoInstallers] CopyFiles = CoCopyINF_DLL.CopyFiles AddReg = CoCopyINF.CoInstaller.Reg [FAST4_ISA.ntx86.HW] AddReg = FAST_ISA.HW.AddReg [FAST4_ISA.ntx86.Services] AddService = %SPEED.ServiceName%, 0x00000002, SPEED.Service, SPEED.EventLog [FAST4_ISA.ntx86.FactDef] ConfigPriority = HARDRECONFIG IOConfig = 100-11F(3FF::) IRQConfig = 11 [FAST8_ISA.ntx86] CopyFiles = SPEED.CopyFiles, SPEED_DLL.CopyFiles AddReg = SPEED_DLL.AddReg LogConfig = FAST8_ISA.LogConfig CopyINF = %PortsINF% [FAST8_ISA.ntx86.CoInstallers] CopyFiles = CoCopyINF_DLL.CopyFiles AddReg = CoCopyINF.CoInstaller.Reg [FAST8_ISA.ntx86.HW] AddReg = FAST_ISA.HW.AddReg [FAST8_ISA.ntx86.Services] AddService = %SPEED.ServiceName%, 0x00000002, SPEED.Service, SPEED.EventLog [FAST8_ISA.ntx86.FactDef] ConfigPriority = HARDRECONFIG IOConfig = 100-13F(3FF::) IRQConfig = 11 [FAST16_ISA.ntx86] CopyFiles = SPEED.CopyFiles, SPEED_DLL.CopyFiles AddReg = SPEED_DLL.AddReg LogConfig = FAST16_ISA.LogConfig CopyINF = %PortsINF% [FAST16_ISA.ntx86.CoInstallers] CopyFiles = CoCopyINF_DLL.CopyFiles AddReg = CoCopyINF.CoInstaller.Reg [FAST16_ISA.ntx86.HW] AddReg = FAST_ISA.HW.AddReg [FAST16_ISA.ntx86.Services] AddService = %SPEED.ServiceName%, 0x00000002, SPEED.Service, SPEED.EventLog [FAST16_ISA.ntx86.FactDef] ConfigPriority = HARDRECONFIG IOConfig = 100-17F(3FF::) IRQConfig = 11 ;------------------------------------------------------------------------------------------- ; PCI-RAS and PCI-RAS V.92 cards ; [RAS_PCI.ntx86] CopyFiles = SPEED.CopyFiles, SPEED_DLL.CopyFiles AddReg = SPEED_DLL.AddReg CopyINF = %PortsINF% [RAS_PCI.ntx86.CoInstallers] CopyFiles = CoCopyINF_DLL.CopyFiles AddReg = CoCopyINF.CoInstaller.Reg [RAS_PCI.ntx86.HW] AddReg = RAS_PCI.HW.AddReg [RAS_PCI.ntx86.Services] AddService = %SPEED.ServiceName%, 0x00000002, SPEED.Service, SPEED.EventLog [RASV92_PCI.ntx86] CopyFiles = SPEED.CopyFiles, SPEED_DLL.CopyFiles AddReg = SPEED_DLL.AddReg CopyINF = %PortsINF% [RASV92_PCI.ntx86.CoInstallers] CopyFiles = CoCopyINF_DLL.CopyFiles AddReg = CoCopyINF.CoInstaller.Reg [RASV92_PCI.ntx86.HW] AddReg = RASV92_PCI.HW.AddReg [RASV92_PCI.ntx86.Services] AddService = %SPEED.ServiceName%, 0x00000002, SPEED.Service, SPEED.EventLog ;------------------------------------------------------------------------------------------- ; UltraPort PCI Adapters ; [ULTRAPORT_PCI.ntx86] CopyFiles = SPEED.CopyFiles, SPEED_DLL.CopyFiles AddReg = SPEED_DLL.AddReg CopyINF = %PortsINF% [ULTRAPORT_PCI.ntx86.CoInstallers] CopyFiles = CoCopyINF_DLL.CopyFiles AddReg = CoCopyINF.CoInstaller.Reg [ULTRAPORT_PCI.ntx86.HW] AddReg = ULTRAPORT_PCI.HW.AddReg [ULTRAPORT_PCI.ntx86.Services] AddService = %SPEED.ServiceName%, 0x00000002, SPEED.Service, SPEED.EventLog ;------------------------------------------------------------------------------------------- ; UltraPort SI PCI Adapters ; [ULTRAPORTSI_PCI.ntx86] CopyFiles = SPEED.CopyFiles, SPEED_DLL.CopyFiles AddReg = SPEED_DLL.AddReg CopyINF = %PortsINF% [ULTRAPORTSI_PCI.ntx86.CoInstallers] CopyFiles = CoCopyINF_DLL.CopyFiles AddReg = CoCopyINF.CoInstaller.Reg [ULTRAPORTSI_PCI.ntx86.HW] AddReg = ULTRAPORTSI_PCI.HW.AddReg [ULTRAPORTSI_PCI.ntx86.Services] AddService = %SPEED.ServiceName%, 0x00000002, SPEED.Service, SPEED.EventLog ;******************************************************************************************* ; Device CoInstallers ;******************************************************************************************* ; CoCopyINF CoInstaller ; [CoCopyINF.CoInstaller.Reg] HKR,,CoInstallers32,0x10000,"cocpyinf.dll,CoCopyINF" ; CoCopyINF CoInstaller & SpxUpChk CoInstaller ; [SPEED.CoInstallers.Reg] HKR,,CoInstallers32,0x10000,"cocpyinf.dll,CoCopyINF", "spxupchk.dll,SPDUpgChkDevCoInstaller" ;******************************************************************************************* ; Services ;******************************************************************************************* ;------------------------------------------------------------------------------------------- ; SPEED ; [SPEED.Service] DisplayName = %SPEED.Service.DispName% ServiceType = 0x00000001 ; = SERVICE_KERNEL_DRIVER StartType = 0x3 ; = SERVICE_DEMAND_START ErrorControl = 0x1 ; = SERVICE_ERROR_NORMAL ServiceBinary = %12%\speed.sys LoadOrderGroup = Extended Base [SPEED.EventLog] AddReg = SPEED.AddEventLog.Reg [SPEED.AddEventLog.Reg] HKR,, EventMessageFile, 0x00020000, "%%SystemRoot%%\System32\IoLogMsg.dll;%%SystemRoot%%\System32\drivers\speed.sys" HKR,, TypesSupported, 0x00010001, 7 ;**************************************************************************************************** ; Log Config section ;**************************************************************************************************** [FAST4_ISA.LogConfig] ConfigPriority = HARDRECONFIG ; Need to change a jumper to change I/O Addr. IOConfig = 20@100-3FF%FFC0(3FF::) IRQConfig = 3, 4, 5, 7, 10, 11, 12, 15 [FAST8_ISA.LogConfig] ConfigPriority = HARDRECONFIG ; Need to change a jumper to change I/O Addr. IOConfig = 40@100-3FF%FFC0(3FF::) IRQConfig = 3, 4, 5, 7, 10, 11, 12, 15 [FAST16_ISA.LogConfig] ConfigPriority = HARDRECONFIG ; Need to change a jumper to change I/O Addr. IOConfig = 80@100-3FF%FF80(3FF::) IRQConfig = 3, 4, 5, 7, 10, 11, 12, 15 ;******************************************************************************************* ; Add Reg section ;******************************************************************************************* ;------------------------------------------------------------------------------------------- ; SPEED4, SPEED4+ ; [SPEED_DLL.AddReg] HKLM,SOFTWARE\Perle Systems Limited\DeviceMan\SPDPorts,PATH,,SPDPorts.DLL [SPEEDPLUS_PCI.HW.AddReg] HKR,,UINumberDescFormat,,%SPEEDPLUS_PCI_UINumDesc% [SPEED_PCI.HW.AddReg] HKR,,UINumberDescFormat,,%SPEED_PCI_UINumDesc% ;------------------------------------------------------------------------------------------- ; FAST ; [FAST_PCI.HW.AddReg] HKR,,UINumberDescFormat,,%FAST_PCI_UINumDesc% [FAST_ISA.HW.AddReg] HKR,,UINumberDescFormat,,%FAST_ISA_UINumDesc% ;------------------------------------------------------------------------------------------- ; RAS ; [RAS_PCI.HW.AddReg] HKR,,UINumberDescFormat,,%RAS_PCI_UINumDesc% [RASV92_PCI.HW.AddReg] HKR,,UINumberDescFormat,,%RASV92_PCI_UINumDesc% ;------------------------------------------------------------------------------------------- ; ULTRAPORT, ULTRAPORT SI ; [ULTRAPORT_PCI.HW.AddReg] HKR,,UINumberDescFormat,,%ULTRAPORT_PCI_UINumDesc% [ULTRAPORTSI_PCI.HW.AddReg] HKR,,UINumberDescFormat,,%ULTRAPORTSI_PCI_UINumDesc% ;******************************************************************************************* ; Destination Directories ; 11: System directory. This is %windir%\system32 on Windows NT and %windir%\system on Windows 95. ; 12: Drivers directory. This is %windir%\system32\drivers on Windows NT. ; 17: INF file directory. ;******************************************************************************************* [DestinationDirs] DefaultDestDir = 12 SPEED.CopyFiles = 12 SPEED_DLL.CopyFiles = 11 CoCopyINF_DLL.CopyFiles = 11 SpxUpChk_DLL.CopyFiles = 11 ;******************************************************************************************* ; Copy Files Section ;******************************************************************************************* [SPEED.CopyFiles] Speed.sys,,,0x2 ; COPYFLG_NOSKIP [SPEED_DLL.CopyFiles] SpdPorts.dll,,,0x2 ; COPYFLG_NOSKIP [CoCopyINF_DLL.CopyFiles] CoCpyINF.dll,,,0x10 ; COPYFLG_NO_OVERWRITE [SpxUpChk_DLL.CopyFiles] SpxUpChk.dll,,,0x10 ; COPYFLG_NO_OVERWRITE ;******************************************************************************************* ; Source Disks ; ; diskid = description[, [tagfile] [, <unused>, subdir]] ; filename_on_source = diskID[, [subdir][, size]] ; ;******************************************************************************************* [SourceDisksNames.x86] 1 = %DiskDescription%,,, [SourceDisksFiles.x86] Speed.sys = 1,, ; on distribution Disk 1 SpdPorts.dll = 1,, ; on distribution Disk 1 CoCpyINF.dll = 1,, ; on distribution Disk 1 SpxUpChk.dll = 1,, ; on distribution Disk 1 ;******************************************************************************************* ; Strings ;******************************************************************************************* [Strings] Perle_Systems = "Perle Systems Limited" DiskDescription = "Perle Driver Disk or CDROM" ;------------------------------------------------------------------------------------------- ; SPEED4, SPEED4+ ; SPD2_PCI.DeviceDesc = "Perle SPEED2 PCI Adapter" SPD4_PCI.DeviceDesc = "Perle SPEED4 PCI Adapter" SPD2AND4LB_PCI.DeviceDesc = "Perle SPEED2/4 PCI Adapter Local Bus" SPD2P_PCI.DeviceDesc = "Perle SPEED2+ PCI Adapter" SPD2PLB_PCI.DeviceDesc = "Perle SPEED2+ PCI Adapter Local Bus" SPD4P_PCI.DeviceDesc = "Perle SPEED4+ PCI Adapter" SPD4PLB_PCI.DeviceDesc = "Perle SPEED4+ PCI Adapter Local Bus" SPEED_PCI_UINumDesc = "Port %1!u! on SPEED PCI Adapter" SPEEDPLUS_PCI_UINumDesc = "Port %1!u! on SPEED+ PCI Adapter" ;------------------------------------------------------------------------------------------- ; FAST ; FAST4_PCI.DeviceDesc = "Perle PCI-Fast 4 Port Adapter" FAST8_PCI.DeviceDesc = "Perle PCI-Fast 8 Port Adapter" FAST16_PCI.DeviceDesc = "Perle PCI-Fast 16 Port Adapter" FAST16FMC_PCI.DeviceDesc = "Perle PCI-Fast 16 FMC Port Adapter" FAST_PCI_UINumDesc = "Port %1!u! on PCI-FAST Adapter" ATFAST4_ISA.DeviceDesc = "Perle AT-Fast 4 Port Adapter" ATFAST8_ISA.DeviceDesc = "Perle AT-Fast 8 Port Adapter" ATFAST16_ISA.DeviceDesc = "Perle AT-Fast 16 Port Adapter" FAST_ISA_UINumDesc = "Port %1!u! on AT-FAST Adapter" ;------------------------------------------------------------------------------------------- ; RAS ; RAS4_PCI.DeviceDesc = "Perle PCI-RAS 4 Multi-modem Adapter" RAS8_PCI.DeviceDesc = "Perle PCI-RAS 8 Multi-modem Adapter" RAS4V92_PCI.DeviceDesc = "Perle PCI-RAS 4 V.92 Multi-modem Adapter" RAS8V92_PCI.DeviceDesc = "Perle PCI-RAS 8 V.92 Multi-modem Adapter" RAS_PCI_UINumDesc = "Port %1!u! on PCI-RAS Adapter" RASV92_PCI_UINumDesc = "Port %1!u! on PCI-RAS V.92 Adapter" ;------------------------------------------------------------------------------------------- ; ULTRAPORT, ULTRAPORT SI ; ULTRAPORT1_PCI.DeviceDesc = "Perle UltraPort1 Adapter" ULTRAPORT2_PCI.DeviceDesc = "Perle UltraPort2 Adapter" ULTRAPORT4_PCI.DeviceDesc = "Perle UltraPort4 Adapter" ULTRAPORT8_PCI.DeviceDesc = "Perle UltraPort8 Adapter" ULTRAPORT16_PCI.DeviceDesc = "Perle UltraPort16 Adapter" ULTRAPORT8I_PCI.DeviceDesc = "Perle UltraPort8i Adapter" ULTRAPORT1SI_PCI.DeviceDesc = "Perle UltraPort1 SI Adapter" ULTRAPORT2SI_PCI.DeviceDesc = "Perle UltraPort2 SI Adapter" ULTRAPORT4SI_PCI.DeviceDesc = "Perle UltraPort4 SI Adapter" ULTRAPORT8SI_PCI.DeviceDesc = "Perle UltraPort8 SI Adapter" ULTRAPORT16SI_PCI.DeviceDesc = "Perle UltraPort16 SI Adapter" ULTRAPORT8ISI_PCI.DeviceDesc = "Perle UltraPort8i SI Adapter" ULTRAPORT_PCI_UINumDesc = "Port %1!u! on UltraPort Adapter" ULTRAPORTSI_PCI_UINumDesc = "Port %1!u! on UltraPort SI Adapter" SPEED.ServiceName = "SPEED" SPEED.Service.DispName = "Perle SPEED Multi-port Serial Driver" PortsINF = "SPDPORTS.INF"Download Driver Pack
After your driver has been downloaded, follow these simple steps to install it.
Expand the archive file (if the download file is in zip or rar format).
If the expanded file has an .exe extension, double click it and follow the installation instructions.
Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.
Find the device and model you want to update in the device list.
Double-click on it to open the Properties dialog box.
From the Properties dialog box, select the Driver tab.
Click the Update Driver button, then follow the instructions.
Very important: You must reboot your system to ensure that any driver updates have taken effect.
For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.