README.TXT Driver File Contents (ICU.EXE)

*******************************************************************
*README.TXT                   Release Notes for Plug and Play Kit *
*                                   for MS-DOS(R) and Windows(TM) *
*Release 1.23                                           June 1994 *
*******************************************************************

Introduction
============

This kit contains Release 1.23 of the Plug and Play Kit for
MS-DOS and Windows.  The components of this kit are:

Plug and Play Configuration Manager (CM) for MS-DOS and Windows.
      Provides configuration services to real-mode and protected-
      mode drivers and to applications in MS-DOS and Windows 
      environments.

Plug and Play ISA Configuration Utility (ICU) for MS-DOS and 
Windows.
      Provides a way to assign system resources to add-in cards
      before the card is installed.  This assignment avoids 
      resource conflicts and keeps track of system resources so 
      that Plug and Play cards do not conflict with non-Plug
      and Play cards in a system.


Installation Notes
==================

1) On systems with MS-DOS version 6.0 or later that use a multipath 
   config.sys file, the MS-DOS installation procedure might corrupt 
   the config.sys file by duplicating sections of the file and 
   corrupting the duplicate sections.  If you have this type of 
   config.sys file, verify the integrity of the config.sys file 
   before rebooting your system.  If you see this problem, perform
   the following steps:

   a) Replace the config.sys file with the backup file made by the 
      installation, config.bak.  

   b) Edit the config.sys file and add a line to load the CM driver to
      the beginning of the file.  Here is an example line that assumes 
      the default installation:

      DEVICE=C:\PLUPGPLAY\DRIVERS\DOS\DWCFGMG.SYS

2) The installation procedures in this kit assume that C: is 
   the boot drive of the system.  Therefore, the procedures
   create, make changes to, or overwrite boot drive files on C:.
   In particular, the procedures and create or modify the config.sys
   file in C:\.

   Some utilities, for example, the Stacker disk compression 
   utility, can change the boot drive from C: to another drive.
   Such drive changes are not always obvious to the user. In 
   order to avoid the user having to move and edit files, the 
   installation procedure must make an INT 21 call to detect 
   the boot device before changing the config.sys file.

3) If you have already installed one version (MS-DOS or Windows) 
   of the kit, install the other version in the same directory as 
   you installed the first version.  By default, both versions of 
   the installation use the same directory: c:\plugplay.  

   If you use a different directory, the system configuration 
   information displayed when you invoke the Windows ICU might
   look different than that displayed when you invoke the 
   MS-DOS ICU.


MS-DOS Installations
--------------------

1) To install and run the Plug and Play Kit for MS-DOS, your 
   system must have a minimum of 488 KBytes of free conventional 
   memory. 

2) Run the MS-DOS installations for the kit components from MS-DOS, 
   not from an MS-DOS window under Windows.

3) The MS-DOS install program on these diskettes is incompatible 
   with the expanded memory manager (emm386).  Before installing
   the Plug and Play kit for MS-DOS, disable your expanded memory
   manager. After you have finished the installation, you can 
   enable the expanded memory manager again.

4) The MS-DOS installation fails during an overinstall of a  
   previous version of the Kit if the user has changed the file 
   permissions of the previously installed version to read-only.

5) During MS-DOS installations, you are offered the opportunity 
   to select from one or more choices. The highlighted choice 
   (that is, the choice selected when you press the Enter key) 
   is lighter than the other choices.  On many, but not all, 
   displays, the highlighted choice flashes.
    
6) More configuration files are installed by the Windows ICU setup
   program than by the MS-DOS ICU install program.  If you want a
   configuration file for a certain card, and you cannot find it 
   in the list offered by the MS-DOS ICU, install the Windows ICU 
   in the same location that you installed the MS-DOS ICU, then 
   reinvoke either version of the ICU and check again for the 
   card. 

7) If you need to run the ICU from diskette, you can create a bootable
   diskette as follows:
       - Make a copy of the installation diskette (e.g. with the MS-DOS 
	 DISKCOPY program),
       - Remove the following files from the new diskette:
	     INSTALL.EXE
	     INSTALL.DAT
	     CONMOD.EXE
	     README.TXT
       - Make the new diskette bootable with the MS-DOS SYS command 
	 (e.g. SYS A:).

Windows Installations
---------------------

1) If the Windows screen saver becomes active during the Windows
   ICU setup, the index generator that runs at the end of the
   setup program is iconized as an MS-DOS icon.  To complete
   the setup procedure, return to Windows and maximize the 
   MS-DOS icon.  

2) The Windows ICU installation fails on a system that has MS-DOS 
   6.0 installed with the VSafe virus scanner active if the VSafe 
   scanner checks executable files and protects executable files
   (VSafe options 4 and 8). 

3) A problem might occur if a previously installed version of 
   the Windows ICU was deleted.  The Windows ICU installation 
   does not put the proper device driver entries into the 
   windows/system.ini file if there is an entry in the win.ini 
   file under [ConfigMgr] of Installed=yes.

   Delete this entry to from the win.ini file and run the Windows
   installation again, or edit the windows/system.ini file and  
   insert the driver entries in the [386Enh] section of the file:
      device=VCAD.386
      device=VCMD.386

   For PCMCIA support in the Windows ICU, also add (to the 
   same section):
      device=pccardrm.386

4) The R1.23 installations replace the old readme.* files from
   previous releases with this readme.txt file. The installations
   do not remove the icons for these older readme files from the 
   Plug and Play Windows program group.  Please remove the icons 
   for these files and leave only the icon named "Release 
   Notes."


****************************************************************** 
*Plug and Play Kit for MS-DOS and Windows                        *
******************************************************************

The components of the Plug and Play Kit for MS-DOS and Windows are:

- The Plug and Play Configuration Manager (CM)
- The ISA Configuration Utility (ICU)

   
Plug and Play Configuration Manager (CM)
========================================

The Plug and Play Configuration Manager provides all of the 
functionality  defined in the "Plug and Play Device Driver
Specification for Microsoft(R) Windows(TM) and MS-DOS".  

The Configuration Manager also complies with the specifications
and definitions in:

  "Plug and Play ISA Specification", Version 1.0a 
      from Intel Corporation and Microsoft Corporation

  "Plug and Play BIOS Specification", Version 1.0a 
      from Intel Corporation, Compaq Computer Corporation, 
      Phoenix Technologies, Ltd.

  "Plug and Play BIOS Extensions Guide", Version 1.21
      from Intel Corporation

  "PCI BIOS Specification", Version 2.1, from Intel Corporation

  "Extended System Configuration Data Specification" 
      Version 1.02A, from Intel Corporation, Compaq Computer
      Corporation, and Phoenix Technologies, Ltd.
  
This release of the Configuration Manager supersedes all previous
releases.


ISA Configuration Utility (ICU)
===============================

The ISA Configuration Utility provides a way to assign system 
resources to add-in cards before the card is installed.  This 
assignment avoids resource conflicts and keeps track of system 
resources so that Plug and Play cards do not conflict with 
non-Plug and Play cards in a system.

			  NOTE
     The ISA Configuration Utility is for ISA systems 
     only.  Do not run it on EISA systems.  To configure
     EISA systems, use an EISA Configuration Utility.


New Functionality
*****************

This release adds the following functionality to the R1.1 
Plug and Play Kit for MS-DOS and Windows:

New Configuration Manager Functionality
=======================================

Dynamic Loading of the Configuration Manager Driver.
   Parts of the Configuration Manager driver (dwcfgmg.sys) 
   are loaded into memory when the driver is needed and 
   unloaded when it is no longer needed.  This results
   in significant memory savings over the R1.1 CM, where 
   the entire driver stayed resident in memory.

Default MS-DOS CM Installation Supports Locking.
   By default the functionality provided by the CM_LockConfig and 
   CM_UnlockConfig functions is available to applications running
   in real-mode MS-DOS environment.

   The CM lock functionality is always available under Windows, 
   including the Windows V86 DOS. 

   If this functionality is not needed, add the /NOLOCK parameter 
   in the line in config.sys that invokes the CM driver 
   (dwcfgmg.sys).
				NOTE
	 The CM_LockConfig and CM_UnlockConfig functions 
	 are unrelated to the locking options available 
	 with ECU or ICU utilities.   Details on these 
	 functions are available in the "External Plug and
	 Play Interfaces Specification."

Support for all Plug and Play BIOS Installation Check 
Structures.
   The Configuration Manager now supports all three versions of
   the Plug and Play BIOS Installation Check structures: 
   - that defined in the Plug and Play ISA Specification V1.0.  
   - that defined in the Plug and Play BIOS Specification V1.0
   - that defined in the Plug and Play BIOS Specification V1.0a
   The R1.1 Configuration Manager only supported the structure 
   defined in the Plug and Play ISA Specification V1.0.

Plug and Play BIOS Support.
   On a Plug and Play BIOS System, the ESCD image is now 
   synchronized with the System Device Nodes and the Statically
   Allocated Resource Information maintained by the Plug and
   Play BIOS.  

New /NODCD Option.
   When the /NODCD option is specified and no DCD (Plug and Play
   ISA or PCI device) is present in the system, the driver 
   deinstalls itself from memory. 

New /STATIC Option.
   When the /STATIC option is specified, the Configuration Manager
   remains resident in memory and is not unloaded when there is
   no runtime function active.

New /NOVCPI Option.
   When the /NOVCPI option is specified, the Configuration Manager
   does not use the Virtual Control Program Interface (VCPI) to 
   switch from virtual 8086 mode to real mode (via protected mode)
   prior to calling ACFG BIOS or Plug and Play BIOS run-time
   functions.

Detection of PCI Devices.
   Any PCI device missing from the ESCD image is added and 
   any PCI device no longer present is removed from the ESCD 
   image.

Configuration of PCI Devices.
   Any non-boot/non-PC Compatible PCI device not configured by the 
   BIOS is configured and activated by CM.


New ISA Configuration Utility Functionality
===========================================

This release adds the following functionality to the R1.1 ISA
Configuration Utility (ICU)

- The ICU complies with the following three specifications: 
  - that defined by the Plug and Play ISA Specification V1.0.  
  - that defined by the Plug and Play BIOS Specification V1.0
  - that defined by the Plug and Play BIOS Specification V1.0a
  
- The ICU now provides support for displaying PCMCIA cards and
  their resource usage (if PCMCIA Card Services that recognizes
  the Configuration Manager is also running on the system).

- The ICU now displays names for PCI devices.  These names 
  describe the device's functionality.

- The ICU now supports enabling and disabling PCI devices.  This
  feature is available when Version 1.21 of the ACFG BIOS is
  running on the system.

- The ICU now includes the conflicting resource value when it 
  reports conflicts, as well as the conflicting card and resource
  type.

- The Windows ICU now provides an online User's Guide in Windows
  Help format.

- Messages that notify the user of conflicts display a resource
  value as well as a resource type.

  
PCMCIA VxD
----------
The Windows version of this release installs the following file:

<drive>:\windows\system\pccardrm.386    
   This file is a PCMCIA Card Services virtual device driver (VxD).
   This VxD allows the ICU to receive PCMCIA card events for Card 
   Services clients in Windows, thus allowing the ICU display to 
   include PCMCIA cards.  For this VxD to work properly, real mode 
   Card Services must be running on your system.

   An entry for this VxD is put into the \windows\system.ini file 
   under [386Enh] but is commented out.  Edit the file and 
   remove the comment character(;) to activate the VxD.


Plug and Play Kit Notes and Limitations
***************************************

Release 1.23 of the Plug and Play Kit for MS-DOS and Windows
has the following limitations:

- It is not possible to load the Configuration Manager into
  High Memory without using the /NOVCPI option.

- The CM and ICU do not support more than one PCI bus.

- When the CM or ICU move a PCI card, they allocate memory resources
  according to the run-time memory requirement of the card.  If this
  value is smaller than the PCI card's boot-time memory requirement, 
  the BIOS relocates the PCI card the next time the system is booted.
  Therefore, the system boots in a different configuration than that
  last assigned by the CM and ICU.

- The CM and ICU do not take into account the Shadow attribute of the 
  memory blocks.  So, there may be incompatible ROMs in the same
  shadow region.  A workaround for this is to have all off-board
  ROMS use the same mode - shadowed or not shadowed.  The preferred
  mode is not shadowed, since not all cards support ROM shadowing.

- The CM and ICU do not differentiate between 8-bit and 16-bit devices.
  Thus, both device types can be allocated memory in the same 128K 
  block.  Due to ISA bus addressing, this memory allocation method can 
  cause cards to not work.  To work around this problem, design your 
  devices to require memory in 128K blocks.

Configuration Manager Notes and Limitations
===========================================

- It is not possible to load the Configuration Manager into
  High Memory without using the /NOVCPI option.

- Whenever the Configuration Manager executes a 32-bit I/O read to 
  the Plug and Play BIOS the system may hang and/or reset.
  The problem occurs only on systems with a Plug and Play BIOS, Plug 
  and Play software Release 1.23, and EMM386 versions prior to 4.49.

  To fix this problem, use version 4.49 or higher releases of the 
  EMM386 memory manager.  End-users with earlier versions of the 
  EMM386 memory manager should contact their dealer for
  information on obtaining an updated EMM386 device driver.

- Using the DOS 6.21 or 6.22 Memmaker program with a Plug and Play 
  system may cause system reboots.  Selecting the Memmaker program's 
  "Aggressive" memory scanning option causes Memmaker to specify 
  HIGHSCAN as an option parameter to EMM386 in the config.sys file.  
  The HIGHSCAN option may cause EMM386 to map memory into the memory
  space used by the system BIOS.  In this instance,   EMM386 does not 
  recognize that the BIOS may be using the entire range from
  E400:0 to F000:FFFF.  Typically, the system reboots when the
  Configuration Manager begins initialization, however the behavior 
  may vary from system to system depending upon the BIOS.

  To work around this problem, do not select the "Aggressive" memory 
  scan option on Memmaker.

- Some memory managers map memory on top of the Plug and Play BIOS. To
  prevent this the E400 to EFFF range should be excluded.

- Software exists that is incompatible with proper Configuration 
  Manager operation.  The interaction between this software and 
  the CM might cause unusual system behavior or system delays 
  when both the CM and the software are running on the system.

  If you suspect such interaction is causing problems on your
  system, try adding the /STATIC and/or the /NOVCPI options to 
  the dwcfgmg.sys driver line in the config.sys file.  Either
  or both options might remedy the problem.

- If you use the /FILE option of the Configuration Manager on a 
  system with the ACFG BIOS, and you don't provide motherboard 
  information for the system in an escd.rf file, the ICU cannot
  run.

ISA Configuration Utility Notes and Limitations
===============================================

- When you save an image file (Save Image File or Save Image File
  As.. on the Advanced menu), the icu.ndx index file is not 
  updated.  So, if the configuration you saved contained one or 
  more unlisted cards, when you load the image file you saved, 
  the card resources for these unlisted cards are in the loaded
  configuration image. However, cards of this type might be listed 
  as "Unknown Card," instead of by the name you assigned
  when you added it.  You can avoid this behavior by choosing the
  Save item on the File menu before you save the image file.  In 
  addition, if you copy the image file to another system, you 
  must also copy the icu.ndx index file to avoid this behavior.

- Pressing the F1 key invokes the ICU help facility from the
  ISA Configuration Utility window (the main window) only.

- When you are modifying a function of a Plug and Play card in 
  preparation for locking it, you might see a conflict message
  that indicates the card is conflicting with itself.  Try 
  reconfiguring the card functions in a different order.

- If a function has two or more resource types that must be 
  configured together, the ICU might not be able to configure 
  that function, even though there might be a valid configuration
  available.  To solve this problem you have to reconfigure the
  conflicting card(s).

- When you pick a resource for a new card that is currently used
  by an existing card, the ICU reconfigures the Plug and Play ISA 
  cards first, then the PCI cards.  However, PCI cards are 
  restricted to specific interrupts.  Sometimes, the configuration 
  fails because the ICU assigns Plug and Play cards to all the 
  valid PCI card interrupts.  Then, The ICU cannot configure the 
  PCI cards.  Use the ICU to reconfigure the Plug and Play cards
  to different interrupts, then try again to configure your new 
  card.

- Because of ISA architecture limitations, ISA cards cannot use
  Interrupt 2, but must use Interrupt 9 instead.  The ICU takes
  this limitation into account and only allows users to choose
  Interrupt 9 when Interrupt 2 is listed as a valid resource value
  in a configuration file.  When this substitution occurs, the
  interrupt value is offered as "Interrupt 9(2)."

- When you are configuring an unlisted card, if the card 
  manufacturer's documentation lists Interrupt 2 as a valid
  resource value, you must instead choose Interrupt 9.

- A set of reserved resources is standard on ISA systems.  
  However, the ICU mistakenly allows these resources to be 
  allocated by the user.  Please do not allocate the following 
  resources:
	I/O Ports       279h, A79h

- You can increase the size of the Smartdrv buffer to make the ICU
  faster.

MS-DOS ICU Limitations
----------------------

- The MS-DOS ICU installation might fail if some Terminate and 
  Stay Resident (TSR) programs or drivers are resident in memory. 
  If this happens, remove all TSRs from memory and restart the 
  install process. Some example TSRs and drivers are: Borland 
  Side Kick and network drivers that are not loaded from 
  config.sys.

- You might see this message:
	N100: Not enough memory to run the ICU.
  In a few cases, 488 KBytes of free memory is insufficient.  
  In these cases, ICU operation ceases suddenly and you see an 
  MS-DOS "Out of Memory" error.  In this situation, use the 
  Windows version of the ICU if it is available.  If the Windows
  ICU is not available, use the Save item on the File menu 
  after each card operation to avoid losing too much work.  

- You might see this message:
	N110: Please run the ICU from its directory.
  You must invoke the ICU from the directory that contains the DB 
  directory (default placement C:\PLUGPLAY\ICU).    

- You must execute the MS-DOS ICU from MS-DOS only, not from an
  MS-DOS window.  

- If you rearrange the ICU dialog boxes on the screen, you might
  see spurious lines, characters, or buttons.  Do not click the
  mouse on these spurious entities.  Clicking the mouse here 
  causes the system to hang.

- Double-clicking to select an item in a list is not supported.      

- The scroll box (the square slider inside the scrollbar) 
  occasionally does not work.  Use the arrow keys.

- If you initiate an action such as Add Card when the System
  Resource Usage dialog box is visible, the dialog box might 
  close.

Windows ICU Limitations
-----------------------

- If you have no mouse, you might not be allowed to make a 
  choice from the Choices for Configuration list on the Settings 
  screen if the choices above and below the choice you want cause
  conflicts.  The Windows keyboard interface selects each entry 
  instead of just highlighting it. If this happens try using the 
  arrow keys and/or the Page Up/Page Down keys to move in the list.

*******************************************************************
* Trademark and Copyright Citations                               *
*******************************************************************


MS-DOS is a registered trademark, and Windows is a trademark of
Microsoft Corporation.

The program used for MS-DOS installation of components of the
Plug and Play Kit for MS-DOS and Windows, INSTALL, is licensed
software provided by Knowledge Dynamics Corp., P.O. Box 780068,
San Antonio, Texas 78278 (U.S.A.). INSTALL is Copyright (c)
1987-1993 by Knowledge Dynamics Corp., which reserves all copyright
protection worldwide. INSTALL is provided to you for the exclusive
purpose of installing the MS-DOS components of the Plug and Play 
Kit for MS-DOS and Windows. Intel Corporation is exclusively
responsible for the support of the Plug and Play Kit for MS-DOS
and Windows, including support during the installation phase. 
In no event will Knowledge Dynamics Corp. provide any technical
support for the Plug and Play Kit for MS-DOS and Windows.

Other names and trademarks are the property of their respective
companies.
Download Driver Pack

How To Update Drivers Manually

After your driver has been downloaded, follow these simple steps to install it.

  • Expand the archive file (if the download file is in zip or rar format).

  • If the expanded file has an .exe extension, double click it and follow the installation instructions.

  • Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.

  • Find the device and model you want to update in the device list.

  • Double-click on it to open the Properties dialog box.

  • From the Properties dialog box, select the Driver tab.

  • Click the Update Driver button, then follow the instructions.

Very important: You must reboot your system to ensure that any driver updates have taken effect.

For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.

server: web3, load: 2.03