Accton Technology Corporation NDIS Driver Installation Overview ================================= Copyright (c) 1992, 1993 by Accton Technology Corporation. All rights reserved. The driver you need are in the directories MSLANMAN.DOS, MSLANMAN.OS2 and NDIS. The NDIS drivers contained in these subdirectories are used with 3Com 3+Open, Microsoft OS/2 LAN Manager OEM distribution, Release 1.x or 2.x, and other compatible OEM versions of LAN Manager. The drivers named ETHNE conform to the Network Driver Interface Specification (NDIS) defined by Microsoft/3Com. Included in MSLANMAN.DOS, MSLANMAN.OS2, and NDIS subdirectories are the following files: \MSLANMAN.DOS\DRIVERS\ETHERNET\ACCTON\ ETHNE.DOS The DOS NDIS MAC driver PROTOCOL.INI A sample section of PROTOCOL.INI file \MSLANMAN.DOS\DRIVERS\NIF\ ACCTON.NIF Network Information File \MSLANMAN.OS2\DRIVERS\ETHERNET\ACCTON\ ETHNE.OS2 The OS/2 NDIS MAC driver PROTOCOL.INI A sample section of PROTOCOL.INI file \MSLANMAN.OS2\DRIVERS\NIF\ ACCTON.NIF Network Information File \NDIS\DOS EN166XD.NIF Network Information File for LAN Server (DOS) ETHNE.DOS The DOS NDIS MAC driver PROTOCOL.INI A sample section of PROTOCOL.INI file \NDIS\OS2 EN166XO.NIF Network Information File for LAN Server (OS/2) ETHNE.OS2 The OS/2 NDIS MAC driver PROTOCOL.INI A sample section of PROTOCOL.INI file \NDIS NDIS.TXT This readme file OEMSETUP.INF Network Information File for Windows for Workgroups v3.1 WFW.TXT The Installation guide for Windows for Workgroups v3.1 LANMAN.TXT The Installation guide for LAN Manager LANSVR.TXT The Installation guide for Lan Server BANYAN.TXT The Installation guide for Banyan VINES PATHWAY.TXT The Installation guide for Wollongong Pathway Access. PATHWORK.TXT The Installation guide for DEC PATHWORKS PCNFS.TXT The Installation guide for Sun PC-NFS Verifying Installation ---------------------- Verify for proper adapter installation by running the diagnostic program using 1STEP. Note that only runs under DOS and will not run under the OS/2 environment. Sample PROTOCOL.INI Files and Parameters ---------------------------------------- [ACCNE_NIF] ; Default section of protocol.ini file for the Accton Adapter drivername = ETHNE$ irq = 3 iobase = 0x300 ; End of this sample file There are several parameters included in the ACCNE_NIF section of the PROTOCOL.INI file. However, the only parameter that you should specify is the "drivername." If you change other parameter settings, such as the IOBASE or IRQ, make sure that it matches the hardware setting. Otherwise, the adapter may fail. If you don't specify these settings, Accton's NDIS driver will automatically detect them. irq Specifies the interrupt channel used by the adapter. Acceptable values for this parameter are 2, 3, 4, 5, 10, 11, 12 ,and 15. However, some of the mentioned Accton adapters do not support all the acceptable values. iobase Specifies the iobase address used by the adapter. This parameter is given in hexadecimal values. Acceptable value for this parameter are 0x200, 0x220, 0x240, 0x260, 0x280, 0x2a0, 0x2c0, 0x2e0, 0x300, 0x320, 0x340, 0x360, 0x380, 0x3a0, 0x3c0, 0x3e0. List of Additional Parameters in the PROTOCOL.INI file for the NDIS Driver Configuration ------------------------------------------------------ Note that values for the following parameters are seldom changed by the user. Most of the time the default values are used. Keyword Parameter MaxMultiCast 1 .. 1000 Default 10 Maximum number of MultiCast Addresses. This configures the size of the MultiCast Address Table. MaxRequests 6 .. 64 Default 8 Maximum number of outstanding General Requests. This configures the size of the General Request Queue. MaxTransmits 6 .. 64 Default 12 Maximum number of outstanding TransmitChain commands. This configures the size of the TransmitChain Request Queue. ReceiveChains 6 .. 96 Default 12 Maximum number of outstanding ReceiveChain commands. This configures the size of the ReceiveChain Request Queue. ReceiveBuffers 6 .. 96 Default 12 Configures the number of the Receive buffers in the Receive Buffer Pool. TransmitBufSize 128 .. 1514 Default 1514 Configures the size (in bytes) of buffers in the Transmit Buffer Pool. Troubleshooting and Error Messages ---------------------------------- To check for problems, please run the Test Adapter option from 1Step. Error Message: ERROR: Adapter card not found or I/O port error. Possible Causes: 1. The adapter is not installed correctly in its slot. 2. I/O port failure due to incompatibility between the computer and the card Solution: Run the 1Step program to determine reason for the error. Error Message: ETHNE-Error-01: Incorrect Media Setting or Bad Transceiver Possible Causes: 1. The transceiver failure. 2. Cable breaks. 3. Loose cable connection. Solution: Run 1Step's diagnostic program to determine the cause of the problem. --- All trademarks or brand names mentioned are properties of their respective companies. -- THE END --Download Driver Pack
After your driver has been downloaded, follow these simple steps to install it.
Expand the archive file (if the download file is in zip or rar format).
If the expanded file has an .exe extension, double click it and follow the installation instructions.
Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.
Find the device and model you want to update in the device list.
Double-click on it to open the Properties dialog box.
From the Properties dialog box, select the Driver tab.
Click the Update Driver button, then follow the instructions.
Very important: You must reboot your system to ensure that any driver updates have taken effect.
For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.