ns8000.txt Driver File Contents (MegaRACv2_4.zip)

AMI IM Utility - Version 1.0
For the following, please refer to InforManager Interface Specification
-----------------------------------------------------------------------
Sensor Type: Temperature
Sensor ID: Processor #1
M (Dec): 543
C (Dec): -17778
K1 (Dec): 0
K2 (Dec): -3
Sensor Maximum Reading (Dec): 0
Sensor Minimum Reading (Dec): 0
High Critical Threshold (Dec): 50.000000
Low Critical Threshold (Dec): 0.000000
High Warning Threshold (Dec): 45.000000
Low Warning Threshold (Dec): 0.000000
**ACCESS #1
Primary Access: Read User Data
Final Access: Write Back To Port
Access Method: I2C
SlaveID (Hex): 1
User Data (Hex): 5
Data Type: unsigned byte
DO NOT STOP
**ACCESS #2
Primary Access: Read Port
Final Access: Save To Global Data
Access Method: I2C
SlaveID (Hex): 1
Data Type: unsigned byte
Read Position (Dec): 1

Sensor Type: Voltage
Sensor ID: Processor #1
M (Dec): 195
C (Dec): 0
K1 (Dec): 0
K2 (Dec): -4
Sensor Maximum Reading (Dec): 0
Sensor Minimum Reading (Dec): 0
High Critical Threshold (Dec): 3.080000
Low Critical Threshold (Dec): 2.520000
High Warning Threshold (Dec): 2.940000
Low Warning Threshold (Dec): 2.660000
**ACCESS #1
Primary Access: Read User Data
Final Access: Write Back To Port
Access Method: I2C
SlaveID (Hex): 1
User Data (Hex): 5
Data Type: unsigned byte
DO NOT STOP
**ACCESS #2
Primary Access: Read Port
Final Access: Save To Global Data
Access Method: I2C
SlaveID (Hex): 1
Data Type: unsigned byte
Read Position (Dec): 2

Sensor Type: Fan
Sensor ID: Processor #1
M (Dec): 60
C (Dec): 0
K1 (Dec): 0
K2 (Dec): 0
Sensor Maximum Reading (Dec): 0
Sensor Minimum Reading (Dec): 0
High Critical Threshold (Dec): 0.000000
Low Critical Threshold (Dec): 1000.000000
High Warning Threshold (Dec): 0.000000
Low Warning Threshold (Dec): 0.000000
**ACCESS #1
Primary Access: Read User Data
Final Access: Write Back To Port
Access Method: I2C
SlaveID (Hex): 1
User Data (Hex): 5
Data Type: unsigned byte
DO NOT STOP
**ACCESS #2
Primary Access: Read Port
Final Access: Save To Global Data
Access Method: I2C
SlaveID (Hex): 1
Data Type: unsigned byte
Read Position (Dec): 4

Sensor Type: Temperature
Sensor ID: Processor #2
M (Dec): 543
C (Dec): -17778
K1 (Dec): 0
K2 (Dec): -3
Sensor Maximum Reading (Dec): 0
Sensor Minimum Reading (Dec): 0
High Critical Threshold (Dec): 50.000000
Low Critical Threshold (Dec): 0.000000
High Warning Threshold (Dec): 45.000000
Low Warning Threshold (Dec): 0.000000
**ACCESS #1
Primary Access: Read User Data
Final Access: Write Back To Port
Access Method: I2C
SlaveID (Hex): 1
User Data (Hex): 5
Data Type: unsigned byte
DO NOT STOP
**ACCESS #2
Primary Access: Read Port
Final Access: Save To Global Data
Access Method: I2C
SlaveID (Hex): 1
Data Type: unsigned byte
Read Position (Dec): 7

Sensor Type: Voltage
Sensor ID: Processor #2
M (Dec): 195
C (Dec): 0
K1 (Dec): 0
K2 (Dec): -4
Sensor Maximum Reading (Dec): 0
Sensor Minimum Reading (Dec): 0
High Critical Threshold (Dec): 3.080000
Low Critical Threshold (Dec): 2.520000
High Warning Threshold (Dec): 2.940000
Low Warning Threshold (Dec): 2.660000
**ACCESS #1
Primary Access: Read User Data
Final Access: Write Back To Port
Access Method: I2C
SlaveID (Hex): 1
User Data (Hex): 5
Data Type: unsigned byte
DO NOT STOP
**ACCESS #2
Primary Access: Read Port
Final Access: Save To Global Data
Access Method: I2C
SlaveID (Hex): 1
Data Type: unsigned byte
Read Position (Dec): 8

Sensor Type: Fan
Sensor ID: Processor #2
M (Dec): 60
C (Dec): 0
K1 (Dec): 0
K2 (Dec): 0
Sensor Maximum Reading (Dec): 0
Sensor Minimum Reading (Dec): 0
High Critical Threshold (Dec): 0.000000
Low Critical Threshold (Dec): 1000.000000
High Warning Threshold (Dec): 0.000000
Low Warning Threshold (Dec): 0.000000
**ACCESS #1
Primary Access: Read User Data
Final Access: Write Back To Port
Access Method: I2C
SlaveID (Hex): 1
User Data (Hex): 5
Data Type: unsigned byte
DO NOT STOP
**ACCESS #2
Primary Access: Read Port
Final Access: Save To Global Data
Access Method: I2C
SlaveID (Hex): 1
Data Type: unsigned byte
Read Position (Dec): 10

Sensor Type: Voltage
Sensor ID: System Board +3.3V
M (Dec): 293
C (Dec): 0
K1 (Dec): 0
K2 (Dec): -4
Sensor Maximum Reading (Dec): 0
Sensor Minimum Reading (Dec): 0
High Critical Threshold (Dec): 3.630000
Low Critical Threshold (Dec): 2.970000
High Warning Threshold (Dec): 3.470000
Low Warning Threshold (Dec): 3.140000
**ACCESS #1
Primary Access: Read User Data
Final Access: Write Back To Port
Access Method: I2C
SlaveID (Hex): 1
User Data (Hex): 8
Data Type: unsigned byte
DO NOT STOP
**ACCESS #2
Primary Access: Read Port
Final Access: Save To Global Data
Access Method: I2C
SlaveID (Hex): 1
Data Type: unsigned byte
Read Position (Dec): 3

Sensor Type: Voltage
Sensor ID: System Board +5V
M (Dec): 293
C (Dec): 0
K1 (Dec): 0
K2 (Dec): -4
Sensor Maximum Reading (Dec): 0
Sensor Minimum Reading (Dec): 0
High Critical Threshold (Dec): 5.500000
Low Critical Threshold (Dec): 4.500000
High Warning Threshold (Dec): 5.250000
Low Warning Threshold (Dec): 4.750000
**ACCESS #1
Primary Access: Read User Data
Final Access: Write Back To Port
Access Method: I2C
SlaveID (Hex): 1
User Data (Hex): 8
Data Type: unsigned byte
DO NOT STOP
**ACCESS #2
Primary Access: Read Port
Final Access: Save To Global Data
Access Method: I2C
SlaveID (Hex): 1
Data Type: unsigned byte
Read Position (Dec): 4

Sensor Type: Voltage
Sensor ID: System Board -5V
M (Dec): -293
C (Dec): 0
K1 (Dec): 0
K2 (Dec): -4
Sensor Maximum Reading (Dec): 0
Sensor Minimum Reading (Dec): 0
High Critical Threshold (Dec): -4.500000
Low Critical Threshold (Dec): -5.500000
High Warning Threshold (Dec): -4.750000
Low Warning Threshold (Dec): -5.250000
**ACCESS #1
Primary Access: Read User Data
Final Access: Write Back To Port
Access Method: I2C
SlaveID (Hex): 1
User Data (Hex): 8
Data Type: unsigned byte
DO NOT STOP
**ACCESS #2
Primary Access: Read Port
Final Access: Save To Global Data
Access Method: I2C
SlaveID (Hex): 1
Data Type: unsigned byte
Read Position (Dec): 5

Sensor Type: Voltage
Sensor ID: System Board +12V
M (Dec): 586
C (Dec): 0
K1 (Dec): 0
K2 (Dec): -4
Sensor Maximum Reading (Dec): 0
Sensor Minimum Reading (Dec): 0
High Critical Threshold (Dec): 13.800000
Low Critical Threshold (Dec): 10.200000
High Warning Threshold (Dec): 13.200000
Low Warning Threshold (Dec): 10.800000
**ACCESS #1
Primary Access: Read User Data
Final Access: Write Back To Port
Access Method: I2C
SlaveID (Hex): 1
User Data (Hex): 8
Data Type: unsigned byte
DO NOT STOP
**ACCESS #2
Primary Access: Read Port
Final Access: Save To Global Data
Access Method: I2C
SlaveID (Hex): 1
Data Type: unsigned byte
Read Position (Dec): 6

Sensor Type: Voltage
Sensor ID: System Board -12V
M (Dec): -586
C (Dec): 0
K1 (Dec): 0
K2 (Dec): -4
Sensor Maximum Reading (Dec): 0
Sensor Minimum Reading (Dec): 0
High Critical Threshold (Dec): -10.200000
Low Critical Threshold (Dec): -13.800000
High Warning Threshold (Dec): -10.800000
Low Warning Threshold (Dec): -13.200000
**ACCESS #1
Primary Access: Read User Data
Final Access: Write Back To Port
Access Method: I2C
SlaveID (Hex): 1
User Data (Hex): 8
Data Type: unsigned byte
DO NOT STOP
**ACCESS #2
Primary Access: Read Port
Final Access: Save To Global Data
Access Method: I2C
SlaveID (Hex): 1
Data Type: unsigned byte
Read Position (Dec): 7

Sensor Type: Temperature
Sensor ID: Internal Ambient
M (Dec): 543
C (Dec): -17778
K1 (Dec): 0
K2 (Dec): -3
Sensor Maximum Reading (Dec): 0
Sensor Minimum Reading (Dec): 0
High Critical Threshold (Dec): 50.000000
Low Critical Threshold (Dec): 0.000000
High Warning Threshold (Dec): 45.000000
Low Warning Threshold (Dec): 0.000000
**ACCESS #1
Primary Access: Read User Data
Final Access: Write Back To Port
Access Method: I2C
SlaveID (Hex): 1
User Data (Hex): 9
Data Type: unsigned byte
DO NOT STOP
**ACCESS #2
Primary Access: Read Port
Final Access: Save To Global Data
Access Method: I2C
SlaveID (Hex): 1
Data Type: unsigned byte
Read Position (Dec): 3

Sensor Type: Fan
Sensor ID: System fan #1
M (Dec): 60
C (Dec): 0
K1 (Dec): 0
K2 (Dec): 0
Sensor Maximum Reading (Dec): 0
Sensor Minimum Reading (Dec): 0
High Critical Threshold (Dec): 0.000000
Low Critical Threshold (Dec): 1000.000000
High Warning Threshold (Dec): 0.000000
Low Warning Threshold (Dec): 0.000000
**ACCESS #1
Primary Access: Read User Data
Final Access: Write Back To Port
Access Method: I2C
SlaveID (Hex): 1
User Data (Hex): a
Data Type: unsigned byte
DO NOT STOP
**ACCESS #2
Primary Access: Read Port
Final Access: Save To Global Data
Access Method: I2C
SlaveID (Hex): 1
Data Type: unsigned byte
Read Position (Dec): 3

Sensor Type: Fan
Sensor ID: System fan #2
M (Dec): 60
C (Dec): 0
K1 (Dec): 0
K2 (Dec): 0
Sensor Maximum Reading (Dec): 0
Sensor Minimum Reading (Dec): 0
High Critical Threshold (Dec): 0.000000
Low Critical Threshold (Dec): 1000.000000
High Warning Threshold (Dec): 0.000000
Low Warning Threshold (Dec): 0.000000
**ACCESS #1
Primary Access: Read User Data
Final Access: Write Back To Port
Access Method: I2C
SlaveID (Hex): 1
User Data (Hex): a
Data Type: unsigned byte
DO NOT STOP
**ACCESS #2
Primary Access: Read Port
Final Access: Save To Global Data
Access Method: I2C
SlaveID (Hex): 1
Data Type: unsigned byte
Read Position (Dec): 4

Sensor Type: Fan
Sensor ID: System fan #3
M (Dec): 60
C (Dec): 0
K1 (Dec): 0
K2 (Dec): 0
Sensor Maximum Reading (Dec): 0
Sensor Minimum Reading (Dec): 0
High Critical Threshold (Dec): 0.000000
Low Critical Threshold (Dec): 1000.000000
High Warning Threshold (Dec): 0.000000
Low Warning Threshold (Dec): 0.000000
**ACCESS #1
Primary Access: Read User Data
Final Access: Write Back To Port
Access Method: I2C
SlaveID (Hex): 1
User Data (Hex): a
Data Type: unsigned byte
DO NOT STOP
**ACCESS #2
Primary Access: Read Port
Final Access: Save To Global Data
Access Method: I2C
SlaveID (Hex): 1
Data Type: unsigned byte
Read Position (Dec): 5

Sensor Type: Generic
Sensor ID: Chassis Cover - Left
M (Dec): 1
C (Dec): 0
K1 (Dec): 0
K2 (Dec): 0
**ACCESS #1
Primary Access: Read User Data
Final Access: Write Back To Port
Access Method: I2C
SlaveID (Hex): 1
User Data (Hex): b
Data Type: unsigned byte
DO NOT STOP
**ACCESS #2
Primary Access: Read Port
Operations in order: AND 1 / XOR 1
Final Access: Save To Global Data
Access Method: I2C
SlaveID (Hex): 1
Data Type: unsigned byte
Read Position (Dec): 3

Sensor Type: Generic
Sensor ID: Power Supply General Failure
M (Dec): 1
C (Dec): 0
K1 (Dec): 0
K2 (Dec): 0
**ACCESS #1
Primary Access: Read User Data
Final Access: Write Back To Port
Access Method: I2C
SlaveID (Hex): 1
User Data (Hex): d
Data Type: unsigned byte
DO NOT STOP
**ACCESS #2
Primary Access: Read Port
Operations in order: AND 1
Final Access: Save To Global Data
Access Method: I2C
SlaveID (Hex): 1
Data Type: unsigned byte
Read Position (Dec): 2

Sensor Type: Generic
Sensor ID: Memory Error EDC - Correctable
M (Dec): 1
C (Dec): 0
K1 (Dec): 0
K2 (Dec): 0
**ACCESS #1
Primary Access: Read User Data
Final Access: Write Back To Port
Access Method: I2C
SlaveID (Hex): 1
User Data (Hex): d
Data Type: unsigned byte
DO NOT STOP
**ACCESS #2
Primary Access: Read Port
Operations in order: AND 2
Final Access: Save To Global Data
Access Method: I2C
SlaveID (Hex): 1
Data Type: unsigned byte
Read Position (Dec): 2

Sensor Type: Generic
Sensor ID: Power Supply Mod2 Failure
M (Dec): 1
C (Dec): 0
K1 (Dec): 0
K2 (Dec): 0
**ACCESS #1
Primary Access: Read User Data
Final Access: Write Back To Port
Access Method: I2C
SlaveID (Hex): 1
User Data (Hex): d
Data Type: unsigned byte
DO NOT STOP
**ACCESS #2
Primary Access: Read Port
Operations in order: AND 10
Final Access: Save To Global Data
Access Method: I2C
SlaveID (Hex): 1
Data Type: unsigned byte
Read Position (Dec): 2

Download Driver Pack

How To Update Drivers Manually

After your driver has been downloaded, follow these simple steps to install it.

  • Expand the archive file (if the download file is in zip or rar format).

  • If the expanded file has an .exe extension, double click it and follow the installation instructions.

  • Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.

  • Find the device and model you want to update in the device list.

  • Double-click on it to open the Properties dialog box.

  • From the Properties dialog box, select the Driver tab.

  • Click the Update Driver button, then follow the instructions.

Very important: You must reboot your system to ensure that any driver updates have taken effect.

For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.

server: web5, load: 1.38