Gene Ethernet Controller Provider Inc.
10/100 Mbps Fast Ethernet PCI Adapter
SoftWare Driver Support
~~~~~~~~~~~~~~~~~~~~~~~
Copyright (C) 1999 Gene Ethernet Controller Provider Inc.
All rights reserved.
****************************************************************************
Product Support
---------------
This release diskette can be used for the following Fast Ethernet Controller
Provider Ethernet adapters:
FastNIC Adapter
How to Configue Your PCI adapter
------------------------------
1. Go to the PCI configuration item in BIOS setup.
2. For legacy computers please follow the following steps to configure the
PCI slot:
a). You should know which slot your adapter is plugged in to. Look for
the physical location of the slot on your PCI motherboard.
b). Set the field that reads "this device" to "Enable".
c). Set the field that reads "this item" to "Master".
The FastNIC PCI adapter MUST be installed in an expansion slot
that supports "Bus Master" Refer to your system documentation to
determine which slots support Bus Mastering.
d). Some BIOS Setups allow you to select which interrupt line you can
use. In our case, select "INT A" for the field that reads "this
item".
e). Select an IRQ of your choice; make sure it does not conflict with
existing IRQs in use.
f). Select the "Trigger method" by which the IRQ is assigned or routed
to the PCI slot. Choose the "level-trigger" option.
Multiple FastNIC PCI adapters can share the same PCI interrupt and
all must use INTA with level-trigger mode.
3. Run the diagnostic program found in the driver diskette. If a problem
arises during the installation, contact your dealer or
Gene Ethernet Controller Provider Inc. for support.
Conflict with Microsoft EMM386
------------------------------
The PCI adapters can only function with the EMM386.exe memory manager
program version 4.49 or later. You can verify its version number by
entering EMM386 at the DOS Prompt.
Do not specify the "highscan" option with the EMM386.exe statement in your
config.sys file, or your system will hang.
If you run MEMMAKER and select Custom Setup, do not specify "Aggressively
scan upper memory", or it will automatically insert the HIGHSCAN flag into
the EMM386 command line. This parameter cannot be manually removed once
it is installed, doing so will prevent the extended memory manager to
function properly.
Support for 5 Volt PCI Slots
----------------------------
The 10/100 Mbps Fast Ethernet PCI Adapter currently supports only 5 volt PCI
slots. Future releases of the adapter will support both 3.3 and 5 volt PCI
slots.
Download Driver Pack
After your driver has been downloaded, follow these simple steps to install it.
Expand the archive file (if the download file is in zip or rar format).
If the expanded file has an .exe extension, double click it and follow the installation instructions.
Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.
Find the device and model you want to update in the device list.
Double-click on it to open the Properties dialog box.
From the Properties dialog box, select the Driver tab.
Click the Update Driver button, then follow the instructions.
Very important: You must reboot your system to ensure that any driver updates have taken effect.
For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.