Upgrading TRAKKER Antares Firmware ----------------------------------- The TRAKKER Antares Firmware Upgrade contains these files: - INSTALL.BAT (user batch file to install the firmware files) - INSTALL.INF - INSTALL.PIF - README.TXT (instructions for using the Firmware upgrade) - a self-extracting archive containing the firmware files, either: - TKANTxxx.EXE (self-extracting archive for official releases), or - TKVxxxxx.EXE (self-extracting archive for field trial releases) NOTE: xxx and xxxxx represent the firmware version number. For example, TKANT710 is the archive for official release 7.10 and TKV71001 is the archive for field trial release 7.10.01 - WHATSNEW.TXT EQUIPMENT YOU NEED TO LOAD THE FIRMWARE To upgrade or load firmware on the TRAKKER Antares 24XX terminals, you need: - TRAKKER Antares 24XX terminal - Intermec RS-232 null modem cable: 9-pin to 25-pin (Intermec P/N 047569) 9-pin to 9-pin (Intermec P/N 059167) - Power supply (Intermec P/N 065236) ----------------------------------------------------------------------- There are two steps to load firmware on the TRAKKER Antares terminals: 1. Install the firmware files on your host computer or PC. You can download the latest version of firmware at no charge from the Intermec Web site at www.intermec.com. 2. Load the firmware on the TRAKKER Antares terminal. Each step is explained next in this README.TXT file. ----------------------------------------------------------------------- STEP 1: INSTALLING THE FIRMWARE ON YOUR HOST COMPUTER OR PC To install the firmware files on your host computer or PC: 1. Copy or extract the upgrade files from your source (Intermec Web site or e-mail) to a temporary folder on your PC. NOTE: If you download the upgrade files from the Intermec Web site, you will be prompted to also download the Trakker Antares Firmware Upgrade Utility (TAUPGRADE.EXE) and the FileCopy application (FILECOPYx.x.EXE, where x.x is the version number). Download TAUPGRADE.EXE if you are using a PC with Microsoft Windows 2000/NT/XP. Download FILECOPYx.x.EXE if you have or need to load TE 2000 on your terminal. 2. In an MS-DOS window, type: install.bat <drive> where <drive> is the specified drive where you want the Install program to create the directory that contains all the firmware, and the upgrade applications. The directory name is TKANTxxx (for a full release) or TKVxxxxx (for a field trial release), where xxx or xxxxx is the firmware version. ----------------------------------------------------------------------- STEP 2: LOADING THE FIRMWARE ON YOUR TRAKKER ANTARES TERMINAL Once you connect the terminal to your host computer or PC, you can download the firmware using one of these utilities: - Trakker Antares DOS Firmware Upgrade Utility. This utility is included with the firmware upgrade. You can use this utility to upgrade the terminal firmware using an MS-DOS window on a PC with Microsoft Windows 95/98. NOTE: If you want to use the DOS Firmware Upgrade Utility on a PC with Windows 2000/NT/XP, you can follow the upgrade procedure through Step 9. Print the UPGRADE.BAT file. Identify the numbers that are associated with the menu selections in Steps 10 through 13. When you get to Step 10, type: UPGRADE X X X X where the Xs represent the menu selection numbers. - Trakker Antares Firmware Upgrade Utility. You can choose to download this utility when you download the latest version of firmware. Or, you can download this utility at no charge from the Intermec Web site at www.intermec.com. This utility allows you to upgrade the terminal firmware using a Microsoft Windows interface on a PC with Microsoft Windows 2000/NT/XP. NOTE: This utility cannot be used to upgrade terminals with 802.1x security. TO UPGRADE THE FIRMWARE USING THE TRAKKER ANTARES DOS FIRMWARE UPGRADE UTILITY 1. Make sure you back up your custom files and applications, such as TE 2000, dcBrowser, and ROM-DOS, so that you can reinstall them after the upgrade procedure. 2. Open an MS-DOS window, and then open the MS-DOS Prompt Properties dialog box. On the Memory tab, set the Initial Environment field to 4096. Close the MS-DOS window and re-open it. 3. In the MS-DOS window, change to the directory that contains the firmware files on your computer. For example, type these commands: c: cd \TKANT700 4. On the Trakker Antares terminal, press these keys to access the TRAKKER Antares 2400 Menu System: FnL Enter 2 4 8 NOTE: If you have a 241X, 242X, or 243X terminal, you must use the left enter key. 5. From the Main Menu, choose the System Menu and press Enter. 6. Choose Upgrade Firmware and press Enter. The Upgrade Firmware screen appears. 7. Choose OK to continue. On the next screen, this prompt appears: Are you sure you want to continue? 8. Choose Yes to continue and upgrade the firmware. The terminal reboots and displays the "Loader Waiting" screen. NOTE: If you reach the Loader Waiting screen and cannot upgrade or continue, press the Esc key once or the 1/0 key twice to exit without upgrading the firmware. The Boot Menu appears. Press 2 or L to access the Loader Waiting screen. 9. On your PC in the MS-DOS window, type this command: UPGRADE 10. A menu appears asking you to select a communications port: Communication ports: 1 - COM1 2 - COM2 3 - COM3 4 - COM4 Select download comm port [ ]: Type the number of the COM port you are using to download firmware from your computer. 11. A menu appears asking you to select a download speed: Communication speed: 1 - 9600 2 - 19200 3 - 38400 4 - 57600 5 - 115200 Select download speed [38400]: Q to Quit Select the baud rate for download. 12. A menu appears asking you to select which protocol stack to use: Software network protocol stack used by TRAKKER Antares 1 - UDP Plus 2 - TCPIP 3 - No Stack (Batch) 4 - WTP Q - Quit Select stack for TRAKKER Antares [ ]: Q to Quit Select a protocol stack. 13. A menu appears asking you to select the communication hardware for your terminal: Communication Hardware for TRAKKER Antares 1 - OpenAir 2.4 GHz Proxim Radio 2 - IEEE 802.11 Direct Sequence Radio 3 - Ethernet 4 - IEEE 802.11 Direct Sequence Radio with 802.1x security enabled Q - Quit NOTE: Option number 4 only appears if you selected option number 2 (TCPIP) from the previous menu. Select communication hardware type for TRAKKER Antares [ ]: Q to Quit Select the appropriate hardware driver for the terminal being upgraded. The Loader screen appears and begins downloading the firmware and application from the computer to the terminal. If the terminal is radio or ethernet equipped, a second Loader screen appears, to load in the network specific and I/O specific drivers. Once the firmware is loaded on the terminal, the terminal reboots, displays the TRAKKER Antares screen, and begins running the default application. You will need to reconfigure the terminal. 14. If necessary, reload your custom applications and files on the terminal. TO UPGRADE THE FIRMWARE USING THE TRAKKER ANTARES FIRMWARE UPGRADE UTILITY NOTE: This utility cannot be used to upgrade terminals with 802.1x security. 1. Install and run this file for upgrade utility: TAUPGRADE.EXE 2. Use the online help that ships with the utility. ----------------------------------------------------------------------- TROUBLESHOOTING If you have a problem loading the firmware on the terminal, here are some things to check: - Make sure the terminal is connected correctly to the host computer or PC. - Make sure you have the firmware files from the Firmware disk installed on your host computer or PC. - Make sure you select the correct COM port during the upgrade process. - Make sure you have selected the Upgrade Firmware option and the terminal is at the Loader Waiting screen when you upgrade or load the firmware. - NOTE: Serial upgrade using the "upgrade.bat" method may not work well in Windows NT & Windows 2000 environments, especially at high baud rates. Also, since 7.10 version of Antares firmware, the program "choice.com" used to satisfy the query requests of the "upgrade.bat" file is distributed, in a form that works in all Windows environments, Win95 through Win2K. Should you have any trouble with baud rate, try a lower baud rate. Should you have trouble with queries, use the parameter method of instructing the "upgrade.bat" of your wishes. - NOTE: The display of the 246X family of readers cannot support the requirements of the MENU system provided in all other TRAKKER Antares units. The actions required to configure 246X units will be provided in bar code form. -----------------------------------------------------------------------Download Driver Pack
After your driver has been downloaded, follow these simple steps to install it.
Expand the archive file (if the download file is in zip or rar format).
If the expanded file has an .exe extension, double click it and follow the installation instructions.
Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.
Find the device and model you want to update in the device list.
Double-click on it to open the Properties dialog box.
From the Properties dialog box, select the Driver tab.
Click the Update Driver button, then follow the instructions.
Very important: You must reboot your system to ensure that any driver updates have taken effect.
For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.