README.TXT Driver File Contents (OPS111v540.zip)

                                                           Graphtec Corporation

OPS111 GRAPHTEC TWAIN32 DRIVER Ver.5.40 Supplementary Information
-------------------------------------------------------------------------------

Introduction

Thank you for using a Graphtec Image Scanner.
OPS111 is a TWAIN driver for use with Graphtec's image scanners, and enables
direct scanner control and scanning-in of drawings from TWAIN-compatible 32-bit
application software. Please be sure to read the following instructions 
carefully before installing the driver. 
Graphtec assumes no responsibility for any liabilities arising out of the use 
of this product.

System Requirements

OS         : Windows 95/98/Me, Windows NT 4.0 Workstation
             Windows 2000 Professional, Windows XP Professional/Home Edition
             (Requires Windows 2000/XP if the scanner is IS200, CS600/500/
             400/300 models.)
CPU        : Pentium 133 MHz or higher grade
Memory     : 32 MB or more
Monitor    : 1024x768, 256 colors or more
Disk space amount that can contain the scanned-in data
Mouse
SCSI board         : An Adaptec SCSI board (to connect the scanner via the SCSI
                     interface)
Network Interface  : 10BASE-T/100BASE-TX (to connect the scanner via the
                     Network interface)
USB Interface      : that comes standard with your computer (to connect the
                     scanner via the USB interface)
IEEE1394 Interface : (to connect the scanner via the IEEE1394 interface)

* If your scanner does not operate with the USB interface that comes with your
  computer, or if your computer does not have a USB 2.0 interface, please
  contact your sales representative or nearest Graphtec vendor for information
  on supported add-on cards.

* Graphtec does not guarantee correct scanner operation with every IEEE 1394
  computer interface or add-on card. Please contact your sales representative
  or nearest Graphtec vendor for information on supported add-on cards.

Recommended Environment

For Bilevel
CPU        : Pentium 200 MHz or higher grade
Memory     : 64 MB or more
SCSI board : An Adaptec SCSI board - for PCI
             (to connect the scanner via the SCSI interface)
Network Interface : 100BASE-TX
                    (to connect the scanner via the Network Interface)
USB 2.0 Interface : that comes standard with your computer
                    (to connect the scanner via the USB interface)

For Grayscale
CPU        : Pentium III 550 MHz or higher grade
Memory     : 256 MB or more
Monitor    : 1024x768, High Color display
SCSI board : An Adaptec SCSI board - for PCI
             (to connect the scanner via the SCSI interface)
Network Interface : 100BASE-TX
                    (to connect the scanner via the Network Interface)
USB 2.0 Interface : that comes standard with your computer
                    (to connect the scanner via the USB interface)

For 8-bit/24-bit color
CPU        : Pentium III 866 MHz or higher grade
Memory     : 512 MB or more
Monitor    : 1024x768, True Color display
SCSI board : An Adaptec SCSI board - for PCI
             (to connect the scanner via the SCSI interface)
Network Interface : 100BASE-TX
                    (to connect the scanner via the Network Interface)
USB 2.0 Interface : that comes standard with your computer
                    (to connect the scanner via the USB interface)

* If you want to scan in grayscale or color data larger than A1 size, 400 dpi,
  you may need a memory larger than the recommended size.
  Depending on the document, it may not be possible to scan in the images it
  contains or the process may slow down even if the memory size is increased.
  If you encounter such a problem, select Setup tab and enable "Use Work File".
  In addition, enable "Specify Folder" and then specify a folder with sufficient
  space.
* For details on the SCSI board, please refer to the User's Manual for your 
  scanner.

Compatible Scanners

  The following Graphtec scanners are compatible.
    IS2100         Ver. 1.00 or later
    IS3100         Ver. 1.00 or later
    CS1000         Ver. 1.00 or later
    CS1000EV       Ver. 2.00 or later
    CS1100EV       Ver. 1.00 or later
    CS2000         Ver. 1.00 or later
    CS300-10       Ver. 1.00 or later
    CS400-10       Ver. 1.00 or later
    CS500-11       Ver.1.00 or later
    CS500-11PRO    Ver.1.00 or later
    CS500-11eN     Ver.1.00 or later
    CS500-11eN-PRO Ver.1.00 or later
    CS600-11       Ver.1.00 or later
    CS600-11PRO    Ver.1.00 or later
    CS600-11eN     Ver.1.00 or later
    CS600-11eN-PRO Ver.1.00 or later
    IS200-11       Ver.1.00 or later
    IS200-11PRO    Ver.1.00 or later
    IS200-11eN     Ver.1.00 or later
    IS200-11eN-PRO Ver.1.00 or later

Installation

The installation process is initiated by running the SETUP.EXE file. After
installation is started, complete installation by following the instructions
appearing on the screen.

Uninstallation

In the same way as for other applications, select [Add/Remove Programs]
from the Control Panel to uninstall the GRAPHTEC TWAIN32 DRIVER.

Notes on Use

1) For operating instructions, refer to the Help menu.
2) To scan in image data through the scanner, you must have a SCSI board and
   ASPI manager for the ASPI that are running.
3) The standard version of Windows 95/98/Me contains an ASPI manager. However,
   there are a few problems (e.g., the standard ASPI manager cannot identify
   the SCSI ID automatically). Neither Windows NT 4.0 nor Windows 2000/XP
   contains an ASPI manager.
   If you want to use Windows 95/98/Me or Windows NT 4.0 for operation, be sure
   to install the ASPI Manager provided with the SCSI board.
   If you want to use Windows 2000/XP for operation, consult with your SCSI
   board vendor or Adaptec distributor.
4) While using GRAPHTEC TWAIN32 DRIVER to read image data from a scanner,
   do not concurrently run other software to read image data from the scanner.
5) Please use TWAIN-compatible 32-bit application software with the GRAPHTEC
   TWAIN32 DRIVER.
   16-bit application software is not supported. If you attempt to use 16-bit
   software, the dialog boxes may not be displayed correctly and image data may
   not be sent. Furthermore, Windows operation may be adversely affected.
6) Depending on the application, there may be limitations on the size of the
   image data that can be handled.
7) When using the scanner in an environment where Adaptec's EZ-SCSI software
   has been installed, problems such as image data not being sent or the
   Cancel button not working may occur, depending on the application being used.
   If problems like these occur, there is a possibility that TWAIN files which
   should only be in the Windows directory have also been installed by EZ-SCSI
   in the Windows system directory.
   If any of the following files are in the Windows System directory, back up
   those files and then remove them from the system directory. For example, if
   Windows is installed in the C: drive:

     In the case of Windows 95/98/Me
        C:\Windows\System\Twain.DLL
        C:\Windows\System\Twain_32.DLL
        C:\Windows\System\Twunk_16.EXE
        C:\Windows\System\Twunk_32.EXE

     In the case of Windows NT 4.0, Windows 2000/XP 
        C:\Windows\System32\Twain.DLL
        C:\Windows\System32\Twain_32.DLL
        C:\Windows\System32\Twunk_16.EXE
        C:\Windows\System32\Twunk_32.EXE

8) If you are using Imaging for Windows 95 (version supplied with OSR2), a
   narrow margin may appear on the right-hand side of the scanned-in data.
9) If a document which is shorter than the specified length is scanned in,
   scanning will be performed to the end of the document, but a dialog box with
   the question [The scanner has reached the end of the paper. Continue
   generating image data?] If you select [Yes], the scanned image will be the
   specified size. If you select [No], the image will be shortened to the actual
   length, but a white margin may be added to the bottom of the image.
   Furthermore, if a Rotate option was selected, the image data may not be
   received correctly by the application program.
10) Reload the document after performing a Prescan operation.
11) If there is another window or a task bar on top of the Details window,
    the image being scanned may be imprecise, or may not be displayed.
    Make sure that the windows are not overlapped.

Compatible application programs

OPS111 has been tested and found to be compatible with the following application
programs (as of April, 2003)

  Imaging for Windows (version supplied with Windows 98)   Eastman Software Inc.
  Imaging for Windows (version supplied with Windows Me)   Eastman Software Inc.
  Imaging for Windows (version supplied with Windows 2000) Eastman Software Inc.

OPS111 does not operate correctly with the following application programs:

  Imaging for NT (version supplied with Windows NT 4.0)    WANG Laboratories
  Imaging for Windows 95 Ver.01.00.00 (download version)   WANG Laboratories
  Microsoft PhotoDraw 2000 Ver.1.0                         Microsoft Corporation

     Windows and Windows NT are the registered trademarks of Microsoft Corp.
     Adaptec is the registered trademark of Adaptec, Inc.
     All copyrights for the GRAPHTEC TWAIN32 DRIVER, including the right of
     reproduction in whole or in part in any form, belong to Graphtec
     Corporation.
Download Driver Pack

How To Update Drivers Manually

After your driver has been downloaded, follow these simple steps to install it.

  • Expand the archive file (if the download file is in zip or rar format).

  • If the expanded file has an .exe extension, double click it and follow the installation instructions.

  • Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.

  • Find the device and model you want to update in the device list.

  • Double-click on it to open the Properties dialog box.

  • From the Properties dialog box, select the Driver tab.

  • Click the Update Driver button, then follow the instructions.

Very important: You must reboot your system to ensure that any driver updates have taken effect.

For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.

server: web5, load: 0.81