**************************************************************************** Fast Ethernet Controller Provider Inc. PCI 10/100 Fast Ethernet Adapter NDIS 2 Driver For SUN PC-NFS Installation ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Copyright (C) 1999 Fast Ethernet Controller Provider Inc. All rights reserved. **************************************************************************** The drivers named FastNIC contained in the directory \NDIS conform to the Network Driver Interface Specification (NDIS) defined by Microsoft/3Com. NDIS Driver Installation on SUN PC-NFS ====================================== 1. Edit the CONFIG.SYS file to include the following command line, and reboot the PC: Device=c:\dos\ansi.sys 2. Insert the PC-NFS Installation diskette into the PC's floppy drive. Type the following at the DOS prompt and press <Enter> to bring up the PC-NFS installation screen: INSTALL <Enter> 3. Follow screen prompts to configure your screen display. For example, press <M> to choose mono display, or press <C> to choose color display, or press <ESC> to cancel the installation. 4. When the "Install the Basic PC-NFS files" window appears onscreen, select "Install Full PC-NFS" from the choice list. 5. "Specify the target PC-NFS installation directory," by typing the appropriate path in the field provided. For example, C:\NFS. Then press <Enter> to continue. 6. Carefully read and respond to each prompt that appears on screen, indicating suitable selections for your system. 7. When you reach the prompt that reads, "Configure an Ethernet network connection", choose "Ethernet" from the choice list. Then press <Enter> to confirm your choice. 8. Choose the network adapter you will use. Select "NDIS" from the list shown on screen. Then press <Enter> to confirm your choice. 9. Follow screen instructions to complete the process. You will be prompted to insert some PC-NFS distribution diskettes. And during the process, files from the diskettes will be copied onto your hard disk drive. 10. When prompted to update your AUTOEXEC.BAT and CONFIG.SYS files, press "Y". 11. Your system will prompt you when the installation process is complete. It will display the following message, "PC-NFS installation is complete." 12. The system will create two subdirectories in the destination drive, namely, \LANMAN and \NFS. 13. Create the NETWORK.BAT, DRIVES,BAT and HOSTS files. Specify the PC name, IP address, server name and server IP address in these files. See the section on Sample Configuration Files for examples. 14. Copy the NETWORK.BAT, DRIVES.BAT and HOSTS files into the \NFS directory of your server. 15. Copy the FastNIC.DOS file from the \MSLANMAN.DOS\DRIVERS\FastNIC\FastNIC of your Driver Diskette to the newly created subdirectory (\LANMAN) on your destination drive. Note: The FastNIC.DOS file is also found in the \NDIS\DOS directory of your Driver Diskette. 16. Edit the CONFIG.SYS file using a text editor. Add the following command line before the NFS_NDIS driver specification: DEVICE=C:\LANMAN\FastNIC.DOS 17. Edit the PROTOCOL.INI file in the \LANMAN directory, replacing the following: a. Replace the section name [your-mac-module] with [FastNIC] b. Replace the command line "drivername = YOURMAC$" with "drivername = FastNIC$" c. Replace the command line "bindings = YOUR-MAC-MODULE" with "bindings = FastNIC" d. Assign the media type and line speed as used in sample PROTOCOL.INI file. 18. Reboot your computer. Then start the application you need. For example: a. Run NFSCONF.EXE to configure the system, such as mounting a virtual drive E: b. Run TELNET.EXE to do terminal emulation Sample Configuration Files -------------------------- 1. NETWORK.BAT REM stc* is a sample PC-NFS workstation name REM Fast Ethernet Controller Provider3 is a sample PC-NFS server address NET START RDR stc* NET PCNFSD Fast Ethernet Controller Provider3 NET NAME stc* 2. DRIVES.BAT REM specify connections to remote directory NET USE l:Fast Ethernet Controller Provider3:/usr2/down NET USE k:Fast Ethernet Controller Provider3:/mnt 3. HOSTS REM specify gateway address 210.65.45.254 <gateway # updated> REM specify workstation's IP address 210.65.45.102 stc REM specify server's IP address 210.65.45.202 Fast Ethernet Controller Provider3 4. CONFIG.SYS Device=c:\dos\himem.sys shell=c:\command.com /P /E:526 dos=high, UMB rem ----pcnfs install Device=c:\dos\ansi.sys DEVICE=C:\NFS\PCNFS.SYS /m DEVICE=C:\NFS\SOCKDRV.SYS REM Specify PROTOCOL.INI directory DEVICE=C:\LANMAN\PROTMAN.SYS /i:C:\LANMAN REM Fast Ethernet Controller ProviderNDIS driver name device=C:\LANMAN\FastNIC.DOS DEVICE=C:\LANMAN\NFS-NDIS.SYS FILES=50 BUFFERS=50 LASTDRIVE=v STACKS=9,256 5. PROTOCOL.INI file at the \LANMAN directory [protocol manager] drivername = PROTMAN$ [FastNIC] drivername = FSTNIC$ ; Slot = 1 ;; {1-4} ; SIA_Mode = AUTODETECT ;; {SIA_Mode = UTP, UTP_FD, UTP_100,UTP_100FD, AUTODETECT} [NFS-NDIS] drivername = NFSLINK$ bindings = FastNIC 6. AUTOEXEC.BAT ... SET TZ=PST8 SET path=C:\;C:\NFS;C:\LANMAN SET NFSDRIVE=D REM Add the following line to bind NDIS driver C:lanman\netbind PRT * REM Execute application you need, e.g. NFSRUN NFSNET INIT NFSRUN All trademarks or brand names mentioned are properties of their respective companies.Download Driver Pack
After your driver has been downloaded, follow these simple steps to install it.
Expand the archive file (if the download file is in zip or rar format).
If the expanded file has an .exe extension, double click it and follow the installation instructions.
Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.
Find the device and model you want to update in the device list.
Double-click on it to open the Properties dialog box.
From the Properties dialog box, select the Driver tab.
Click the Update Driver button, then follow the instructions.
Very important: You must reboot your system to ensure that any driver updates have taken effect.
For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.