OS2.TXT Driver File Contents (sdms43.zip)

***************************************************************************** 
                                    OS2.TXT  
***************************************************************************** 

INSTALLATION GUIDE FOR THE SDMS OS/2 DRIVERS: SYM8XX.ADD V4.06.00
                                              SYM_HI.ADD V4.07.00

This file describes the features and use of the Symbios SDMS device 
driver for the OS/2 operating system environment. It is divided into the 
following sections:

Introduction 
     Features 
     Description 
     Symbios Devices Supported 
Installing Your SDMS OS/2 Driver 
     Installing SYM8XX.ADD/SYM_HI.ADD with OS/2 Already Installed 
     Installing SYM8XX.ADD/SYM_HI.ADD and OS/2 from a Floppy to a 
        SCSI Hard Drive 
     Installing SYM8XX.ADD/SYM_HI.ADD and OS/2 from a SCSI CD-ROM to a 
        SCSI Hard Drive 
     Driver Order in the CONFIG.SYS File 
     Command Line Options 
     Troubleshooting 


******************************** Introduction ********************************* 

The OS/2 operating system version 4.0 provides an integrated platform featuring 
a graphical windowing interface, called Presentation Manager, that allows 
multiple applications to be viewed at the same time. Multitasking is also 
supported, enabling several different programs to run at the same time in 
different windows. Presentation Manager allows the user to switch between 
programs, start other programs, and maintain files and directories. This 
version of OS/2 requires an 80386 or higher microprocessor. Other hardware 
requirements include a minimum of 8 megabytes of RAM and a minimum hard disk 
drive size of 90 megabytes. Symbios SDMS 4.0 provides the necessary SCSI 
device driver for OS/2. We recommend reviewing the OS/2 manual prior 
to proceeding.


*  *  *  *  *  *  *  *  *  * * Features *  *  *  *  *  *  *  *  *  *  *  *  * 

o  Supports synchronous negotiation (including Ultra2 SCSI) 
o  Supports narrow and wide SCSI (single-ended and differential) 
o  Supports multiple host adapters
o  Supports Disconnect/Reselect 
o  Supports Scatter/Gather 
o  Allows tagged command queuing
o  Supports single-ended, differential and low-voltage differential
o  Allows target-initiated negotiation
o  Supports NVRAM/NVS configuration storage
 

New Features:

The SYM_HI.ADD V4.07.00 driver allows up to 8 host adapters to be present in your 
system. The first 4 host adapters will be accessed in the order you specify using 
the SCSI Configuration Utility provided with some members of the 8XX family of host 
adapters. Refer to your host adapter's user guide for information on the availability 
and use of the SCSI Configuration Utility. Remaining host adapters will be accessed 
based on their physical position in your system. Refer to your system documentation 
for further information.

*  *  *  *  *  *  *  *  *  *  * Description  * *  *  *  *  *  *  *  *  *  *  

Although the Symbios SCSI controller's firmware can access the SCSI hard disk 
drives attached to the computer independently, the SCSI device drivers SYM8XX.ADD 
and SYM_HI.ADD act as an enhanced interface between the computer system and the 
SCSI BIOS firmware. Use of the device drivers increases the abilities of the SCSI 
controller firmware and fully utilizes the advancements and improvements of 
Pentium-based and higher microprocessors.

The device drivers are also necessary to support the use of SCSI tape drives 
and CDROM drives with an OS/2 system. The Symbios SYM8XX.ADD and SYM_HI.ADD 
device drivers are written in compliance with the IBM OS/2 ADD (Adapter Device 
Driver) specification, and the device drivers work with third party applications 
that comply with the same specification. 

*  *  *  *  *  *  *  *  *  *  Symbios Devices Supported *  *  *  *  *  *  *  *  *

The SYM8XX.ADD driver supports the following devices and Symbios host adapters based
on those devices: 

SYM53C810, SYM53C810A, SYM53C810AE (SYM8100S, SYM8100ASP) 
SYM53C815 (SYM815XS, SYM8150SP) 
SYM53C825, 53C825A (SYM8250S, SYM8251S, SYM8251D, SYM8250ASP, SYM8251ASP, SYM8251AD) 
SYM53C860, SYM53C860AE (SYM8600SP) 
SYM53C875, SYM53C875E (SYM8750SP, SYM8751SP, SYM8751D) 
SYM53C876 (SYM22801, SYM22802) 
SYM53C885  
SYM53C895 (SYM8951U) 

The SYM_HI.ADD driver supports the  following device and Symbios host adapter
based on this device: 

SYM53C896 (SYM22910)


********************** Installing Your SDMS OS/2 Driver ********************* 

These installation instructions are specific and accurate for the SDMS OS/2 
driver SYM8XX.ADD V4.06.00 and SYM_HI.ADD V4.07.00. You should refer to the text
file OS2.TXT located on the SDMS diskette for a version of these instructions 
guaranteed to match your driver.

The Symbios device driver floppy diskette contains six files for OS/2: the 
device drivers SYM8XX.ADD and SYM_HI.ADD, the text files SYM8XX.DDP and SYM_HI.DDP 
the executable files, SYM8XXPC.EXE and SYM_HIPC.EXE. When the device driver 
installation utility under OS/2 is activated, it looks for all files with the DDP 
extension. The DDP file contains the necessary information to install the SCSI 
device driver. The EXE file contains a utility that verifies that an appropriate 
adapter is present. If you do not wish to install both device drivers, create a
floppy diskette containing the appropriate driver, DDP file and EXE file to use
instead of the Symbios device driver floppy diskette.

Note: If you previously installed OS2CAM.ADD (the previous version of this 
      driver), delete OS2CAM.ADD and delete the corresponding 
      BASEDEV= statement in CONFIG.SYS after you complete installation 
      procedures. If you previously installed SYM8XX.ADD and/or SYM_HI.ADD 
      in a directory other than \OS2\BOOT, move SYM8XX.ADD and/or SYM_HI.ADD
      to \OS2\BOOT, where the new versions of these drivers can replace the old
      versions. The system will continue to boot using the previous drivers until
      these steps are taken.


*  *  *  * Installing SYM8XX.ADD/SYM_HI.ADD with OS/2 Already Installed *  *  *   

1) At the OS/2 Desktop, open the System Setup folder located within the OS/2 
   System folder. Open the Install/Remove folder and then double-click on the
   Device Driver Install icon.

2) Insert the floppy diskette containing the Symbios device driver(s) in 
   the source drive. The system will find all DDP files on the floppy diskette
   and automatically install the corresponding drivers.

3) To make sure that the installation was successful, open the Utilities 
   folder located within the Programs folder on the OS/2 Desktop. Then 
   double-click on the OS/2 System Editor to start the editor. Open the 
   CONFIG.SYS file in the root directory and find the line(s): 

     BASEDEV=SYM8XX.ADD /V
 
     and/or

     BASEDEV=SYM_HI.ADD /V

   Then check that the appropriate drivers are in the \OS2\BOOT directory on 
   the boot drive.


* Installing SYM8XX.ADD/SYM_HI.ADD and OS/2 from a Floppy to a SCSI Hard Drive *  

In this case, since OS/2 will be installed from a floppy diskette, it is not 
required that the driver be present to install the operating system (as is 
the case when installing from a CDROM).

1) After the installation of OS/2 completes and the WorkPlace Shell desktop 
   builds, open the System Setup folder located in the OS/2 System folder. Open
   the Install/Remove folder and then double-click on the Device Driver Install
   icon.

2) Insert the floppy diskette containing the Symbios device driver(s) in 
   the source drive.  The system will find all DDP files on the floppy diskette
   and automatically install the corresponding drivers.

3) To make sure that the installation was successful, open the Utilities
   folder located within the Programs folder on the OS/2 Desktop. Then
   double-click on the OS/2 System Editor to start the editor. Open the
   CONFIG.SYS file in the root directory and find the line(s):

   BASEDEV=SYM8XX.ADD /V

   and/or

   BASEDEV=SYM_HI.ADD /V

   Then check that the appropriate drivers are in the \OS2\BOOT directory on
   the boot drive.

4) Continue with the OS/2 installation process as documented in the OS/2 
   Installation Guide.


* Installing SYM8XX.ADD/SYM_HI.ADD and OS/2 from a SCSI CDROM to a SCSI Hard Drive *  

To install OS/2 from a SCSI CDROM attached to a Symbios host adapter, 
the SCSI driver must be present in order to access the CDROM. The following 
steps allow installation of OS/2 from a SCSI CDROM.

1) Make copies of the floppy diskettes used for installation that are 
   included with the CDROM version of OS/2.

2) Determine the appropriate driver for installation by locating the host adapter
   to which the CDROM is attached in the section of this guide titled "Symbios 
   Devices Supported". Then copy the indicated driver to the copy of Diskette 1.  
   In order to do so, you must delete files on Diskette 1 to provide space.  
   Consult the README.1ST file on the Device Driver Pak Volume 1.0 CD. It contains  
   a list of files that may not be deleted. Follow the instructions provided in the 
   README.1ST file. Once space is made available on Diskette 1, copy the 
   appropriate Symbios device driver onto this diskette.

   When .ADD drivers are deleted from Diskette 1, make certain to delete or 
   remark out the corresponding BASEDEV= statement in the CONFIG.SYS file.
   Otherwise, error messages will show up during installation.

3) Edit the CONFIG.SYS file on the copy of Diskette 1 by adding one of the
   following lines at the end of the file:

   BASEDEV=SYM8XX.ADD /V 

   or

   BASEDEV=SYM_HI.ADD /V

   Follow the directions in the README.1ST file for adding the following 
   line to the CONFIG.SYS file:

   SET COPYFROMFLOPPY=1

   This allows the Symbios driver to be copied from the installation diskette to 
   the system's boot drive.

4) Place the copy of Installation Diskette in the A: drive and reboot the 
   computer.

5) Proceed with the OS/2 installation process as documented in the OS/2 
   Installation Guide.


*  *  *  *  *  *  * Driver Order in the CONFIG.SYS File *  *  *  *  *  *  *

Because of the way OS/2 assigns drive letters, the order in which drivers 
appear in the CONFIG.SYS file is important. The drivers must appear in the 
order in which the drive letters are to be assigned. In particular:

   - OS/2 Warp will install the BASEDEV= line at the beginning of the target 
     system's CONFIG.SYS file regardless of where the line is located in that 
     file on Diskette 1. You may need to rearrange the order in which drivers 
     appear in the CONFIG.SYS file for the target system.

   - The driver for the host adapter to which the boot device is attached must
     appear before all other BASEDEV= drivers in the CONFIG.SYS file.

   - If you are installing both Symbios drivers, the driver corresponding to the 
     host adapter with the boot drive attached must appear first in the CONFIG.SYS
     file. 

Refer to the OS/2 documentation to fully understand this requirement. 


*  *  *  *  *  *  *  *  *  * Command Line Options *  *  *  *  *  *  *  *  * 

Your host adapter has a default configuration that consists of optimal values 
for operation. You may decide to alter these default values if there is a 
conflict between device settings or if you need to optimize system performance. 
Some values may be changed using the SCSI Configuration Utility provided with 
some members of the 8XX family of host adapters. Refer to your host adapter's 
user guide for information on the availability and use of the SCSI Configuration 
Utility. In addition, the Symbios OS/2 device drivers have several embedded 
functions that can be accessed via switches on the command line in the 
CONFIG.SYS file. 

Note:  Values are applied in the following order:

       o  Manufacturer's settings
       o  SCSI Configuration Utility changes
       o  Command line options 

At any point during this process, subsequent changes in synchronous and
wide negotiations may only decrease speed or reduce width. Any changes 
that attempt to increase speed or width will be ignored.

The options available using command line switches are described below. The
SYM8XX.ADD driver is used in all examples; SYM_HI.ADD may be substituted for
SYM8XX.ADD with identical results.


*   *   * Using the /VERBOSE (or /V) Option *   *   *

This option appears on the command line by default. It enables display of 
a banner, version number, and SCSI bus information during start up of the 
system. 

    Usage: 
        /VERBOSE

    For example, if you wish to see more detailed information displayed when 
    you boot, the line in the CONFIG.SYS file that loads SYM8XX.ADD should look 
    like this:

    BASEDEV=SYM8XX.ADD /VERBOSE

    or

    BASEDEV=SYM8XX.ADD /V

    To disable this feature, remove this switch from the command line.


*   *   * Using the /!DM Option *   *   *

This option disables use of the IBM-supplied DASD manager (OS2DASD.DMD) 
for the devices listed. The DASD manager supports direct access devices 
such as hard drives.   

   Usage: 
        /!DM<path[:id]>[,<path[:id]>]*

    where:

        path represents the position of a host adapter as indicated
        by its numbering displayed by the Verbose option. This is
        NOT the SCSI ID of the host adapter.

        id represents a SCSI target ID on the indicated path.    
       
        [ ] indicate optional information.   
       
        * indicates the pattern enclosed in the [ ] may be repeated.   

    For example, if you want to disable OS2DASD.DMD for devices on host 
    adapter 0 at target IDs 3 and 5, the line in CONFIG.SYS that loads 
    SYM8XX.ADD should look like this:

    BASEDEV=SYM8XX.ADD /!DM<0:3>, <0:5>


*   *   * Using the /!SM Option *   *   *

This option disables use of the IBM-supplied SCSI manager (OS2SCSI.DMD) 
for the devices listed. The SCSI manager supports SCSI tape drives.

    Usage: 
        /!SM<path[:id]>[,<path[:id]>]*

    where: 

        path represents the position of a host adapter as indicated by
        its numbering displayed by the Verbose option. This is NOT the
        SCSI ID of the host adapter.
 
        id represents a SCSI target ID on the indicated path.   
 
        [ ] indicate optional information.   
 
        * indicates the pattern enclosed in the [ ] may be repeated.    

    
    For example, if you want to disable OS2SCSI.DMD for devices on host 
    adapter 0 at target IDs 3 and 5, the line in the CONFIG.SYS file that loads 
    SYM8XX.ADD should look like this:

          BASEDEV=SYM8XX.ADD /!SM<0:3>,<0:5>


*   *   * Using the /SYNCH_RATE (or /SR) Option *   *   *

This sets the maximum synchronous transfer rate (in megabyte transfers per 
second) to negotiate with a particular device. The allowable values for 
this setting are 0, 5, 10, 20, and 40 megabyte transfers per second, if the 
adapter is capable of the specified speed. All host adapters in the 8XX 
family support at least 10 megabyte transfers per second; some support 20 or 
40 megabyte transfers per second. To turn off synchronous transfers for a 
particular device, specify 0 (zero). The value set by this option only 
defines the maximum transfer rate negotiated. The actual rate also 
depends on what the device can do. The default value is the fastest 
transfer rate that is supported by a particular host adapter.

Note:  The maximum synchronous transfer rates effectively double when the 
adapter and device permit wide transfers (See the /WIDTH option).  For example,  
a synchronous transfer rate setting of 40 megabyte transfers per second will  
actually produce a transfer rate of 80 megabyte transfers per second if the
adapter and device both allow and are set to perform wide transfers.

    Usage: 
        /SYNCH_RATE = n<path[:id]>[,n<path[:id]>]*

    where: 

        n = 0, 5, 10, 20 or 40.    

        path represents the position of a host adapter as indicated by
        its numbering displayed by the Verbose option. This is NOT the
        SCSI ID of the host adapter.   
 
        id represents a SCSI target ID on the indicated path.  
  
        [ ] indicate optional information.  
  
        * indicates the pattern enclosed in the [ ] may be repeated.    

    For example, if you want to turn off synchronous transfers to ID 3 on 
    host adapter 0, the line in CONFIG.SYS that loads SYM8XX.ADD should look 
    like this:

    BASEDEV=SYM8XX.ADD /SYNCH_RATE=0<0:3>

    As another example, if you want to set synchronous transfers to 10 megabyte 
    transfers per second on all devices on adapter 1, the line in the CONFIG.SYS
    file that loads SYM8XX.ADD should look like this: 

    BASEDEV=SYM8XX.ADD /SR=10<1>


*   *   * Using the /SYNCH_OFFSET (or /SO) Option *   *   *

This sets the maximum synchronous offset to negotiate with a particular 
device. The allowable values for this setting are 0 to the maximum 
synchronous offset supported by the specified path. The SYM53C8XX 
controller chips support offsets up to 31. Refer to your host adapter's 
user guide for information on the maximum offset supported by your
host adapter. If 0 (zero) is specified for the synchronous offset value,
then synchronous transfers are turned off for any specified device. The
value set by this option only defines the maximum offset that is 
negotiated. The resulting rate also depends on the device capability. The
default value is the maximum offset that is supported by a particular host
adapter.

    Usage: 
        /SYNCH_OFFSET = n<path[:id]>[,n<path[:id]>]*

    where: 

        n = 0..maximum synchronous offset for the adapter. 

        path represents the position of a host adapter as indicated by 
        its numbering displayed by the Verbose option. This is NOT the 
        SCSI ID of the host adapter.
 
        id represents a SCSI target ID on the indicated path.   
 
        [ ] indicate optional information.  
  
        * indicates the pattern enclosed in the [ ] may be repeated.    


    For example, if you want to change the synchronous offset to 6 for ID 3, 
    the line in the CONFIG.SYS file that loads SYM8XX.ADD should look like this:

    BASEDEV=SYM8XX.ADD /SYNCH_OFFSET=6<0:3>


*   *   * Using the /TIMEOUT (or /T) Option *   *   *

The Symbios device drivers use a time-out mechanism to detect certain errors.
When the driver issues a command to a SCSI device, a timer is started. If the 
timer expires before the command completes, the driver assumes that something 
has gone wrong with the device, and takes steps to recover. The default value
for this is 10 seconds. If you set the value to be less than the system has
allocated for a particular device, your value will be ignored. To turn off
the time-out mechanism for a particular device, set the value to 0 (zero).
  
 Usage: 
        /TIMEOUT = n<path[:id]>[,n<path[:id]>]*

    where: 

       n = time-out value in seconds for device, n=(0..65535).
   
       path represents the position of a host adapter as indicated by its
       numbering displayed by the Verbose option. This is NOT the SCSI ID
       of the host adapter.  
  
       id represents a SCSI target ID on the indicated path.  
  
       [ ] indicate optional information.   
 
       * indicates the pattern enclosed in the [ ] may be repeated.   

    For example, if you have a particularly slow device on ID 3 and you wish 
    to extend the time out on this device to 60 seconds, then the line in 
    CONFIG.SYS that loads SYM8XX.ADD should look like this:

    BASEDEV=SYM8XX.ADD /TIMEOUT=60<0:3>


*   *   * Using the /DISCONNECT (or /DC) Option *   *   *

SCSI devices have the ability to disconnect from the bus during an I/O 
transfer. This option is used to allow (or not allow) a device to 
disconnect during an I/O. If a particular adapter has parity checking 
disabled, then you must use this option to disable disconnects for all 
devices on that adapter that do not generate parity. This is because the 
/PARITY option does not change the disconnect state for any device on 
that adapter. See the /PARITY option for more information.

    Usage: 
        /DISCONNECT = n<path[:id]>[,n<path[:id]>]*

    where: 

        n = ON or OFF.  

        path represents the position of a host adapter as indicated by 
        its numbering displayed by the Verbose option. This is NOT the
        SCSI ID of the host adapter.  

        id represents a SCSI target ID on the indicated path.  

        [ ] indicate optional information.   

        * indicates the pattern enclosed in the [ ] may be repeated.    


    Valid options are "ON" (allow disconnects) and "OFF" (do not allow 
    disconnects). The default for all devices is "ON".

    For example, if you want to disable disconnects on the device at ID 2, 
    then the line in CONFIG.SYS that loads SYM8XX.ADD should look like this:

    BASEDEV=SYM8XX.ADD /DISCONNECT=OFF<0:2>


*   *   * Using the /PARITY (or /P) Option *   *   *

The SYM53C8XX chips are capable of enabling or disabling the SCSI bus 
data integrity checking feature known as "parity". Some non-SCSI compliant 
devices sold as SCSI devices do not generate parity. You can use this 
option to disable parity checking. The SYM53C8XX chips always generate 
parity (for outputs), but may optionally check the parity (for inputs). 

    Usage: 
        /PARITY = n<path[,path]*>[,n<path[,path]*>]*

    where: 

        n = ON or OFF. 
   
        path represents the position of a host adapter as indicated by
        its numbering displayed by the Verbose option. This is NOT the
        SCSI ID of the host adapter.   
 
        [ ] indicate optional information.   
 
        * indicates the pattern enclosed in the [ ] may be repeated.    

       Valid options are "ON" (check parity) and "OFF" (do not check parity). 
       The default for all devices is "ON", which enables parity checking for 
       all devices.

    Note: When disabling parity checking, it is necessary to disable 
          disconnects for any device that does not generate parity, as the 
          SYM53C8XX chips cannot disable parity checking for that device 
          during the reselection phase. Please refer to using the /DISCONNECT 
          option for more information on how to disable disconnects for a 
          device. If a device does not generate parity and it disconnects, 
          the I/O never completes as the reselection never completes.

    For example, to turn off parity checking on host adapter number 0, the 
    line in CONFIG.SYS that loads SYM8XX.ADD should look like this:

    BASEDEV=SYM8XX.ADD /PARITY=OFF<0>


*   *   * Using the /QTAG (or /QT) Option *   *   *

Queue tagging allows more than one outstanding command per SCSI device.
Some non-SCSI compliant devices sold as SCSI devices do not allow queue 
tags, in which case queue tagging needs to be disabled. The value given in
the command line will be the depth of the queue for queue tags for the 
device(s) indicated. To disable queue tag support, a value of 0 or 1 should
be given.

    Usage: 
        /QTAG = n<path[:id]>[,n<path[:id]>]*

    where: 

        n = the number of queue tags allowed for a device (0..256).  
  
        path represents the position of a host adapter as indicated by
        its numbering displayed by the Verbose option. This is NOT the
        SCSI ID of the host adapter.   
 
        id represents a SCSI target ID on the indicated path.   
 
        [ ] indicate optional information. 
   
        * indicates the pattern enclosed in the [ ] may be repeated.    

    For example, to turn off queue tagging for ID 3 on host adapter number 0, 
    the line in CONFIG.SYS that loads SYM8XX.ADD should look like this:

    BASEDEV=SYM8XX.ADD /QTAG=0<0:3>

    As another example, if you want to set the queue depth to 5 for all 
    devices on host adapter number 2, the line in CONFIG.SYS that loads 
    SYM8XX.ADD should look like this:

    BASEDEV=SYM8XX.ADD /QT=5<2>


*   *   * Using the /WIDTH (or /W) Option *   *   *

Devices attached to a SCSI bus are narrow or wide devices. Narrow devices 
transfer data one byte (or 8 bits) at a time. Wide devices transfer two 
bytes (or 16 bits) at a time. The value given in the command line option 
will determine the size of data transfers.

    Usage: 
        /WIDTH = n<path[:id]>[,n<path[:id]>]*

    where: 

        n = 8 or 16.  
  
        path represents the position of a host adapter as indicated by
        its numbering displayed by the Verbose option. This is NOT the
        SCSI ID of the host adapter. 
   
        id represents a SCSI target ID on the indicated path. 
   
        [ ] indicate optional information. 
  
        * indicates the pattern enclosed in the [ ] may be repeated.   

   
    For example, to have the device at ID 3 on host adapter number 0 treated 
    as a narrow device, the line in the CONFIG.SYS file that loads SYM8XX.ADD 
    should look like this:

    BASEDEV=SYM8XX.ADD /WIDTH=8<0:3>

    As another example, if you want to have all devices on host adapter 
    number 2 treated as 8-bit devices, the line in the CONFIG.SYS file that 
    loads SYM8XX.ADD should look like this:

    BASEDEV=SYM8XX.ADD /W=8<2>


*  *  *  *  *  *  *  *  *  *  * Troubleshooting *  *  *  *  *  *  *  *  *  *

The following are some potential problems and their suggested solutions:

1. Problem: You cannot access the SCSI device(s). 

   Solution: 

     a. Make sure the SCSI device driver is installed properly.

     b. Make sure each device has power.

     c. Verify that the appropriate BASEDEV = line (BASEDEV=SYM8XX.ADD /V or
        BASEDEV = SYM_HI.ADD /V) exists in the CONFIG.SYS file. 

     d. Verify that the correct driver is in the appropriate directory
        (\OS2\BOOT).

     e. Check the cable connections and the host adapter installation.

2. Problem: The computer hangs or locks up when booting and the SCSI devices
            attached are not seen by the computer system.

   Solution: 

     a. Make sure that all the SCSI devices are configured at different ID numbers.
        If booting the system from a device on the SCSI bus, the boot drive must
        have the lowest ID or the highest ID, depending on the scan order option
        selected in the configuration utility. For more information, consult the
        BOOTROM.TXT file or the documentation provided with your host adapter
        board.

     b. Make sure both, but only, the ends of the SCSI bus are terminated.

     c. Make sure the device driver is listed in CONFIG.SYS (and loaded when 
        booting).

3. Problem: The device driver does not see one of the SCSI devices.

   Solution:
 
     a. Reboot the computer.

     b. Make sure the SCSI devices have different ID numbers. 

     c. Make sure both, but only, the ends of the SCSI bus are terminated. 

     d. Check the cable and power connections.

4. Problem: OS/2 installs to an IDE drive in the system instead of installing 
            to the SCSI drive.

   Solution:

     The IDE drive must be physically disconnected and disabled in the CMOS setup 
     before attempting to install to a SCSI drive. 

5. Problem: The following message is displayed at bootup: 

     "OS/2 is unable to operate your hard disk or diskette drive. The system 
     is stopped. Correct the preceding error and restart the system."

   Solution:

     a. This problem is caused when your system is booting from a hard drive 
        attached to an IDE bus, a SCSI disk is attached to your Symbios host 
        adapter, and the statement(s) 

          BASEDEV=SYM8XX.ADD /V 

          and/or

          BASEDEV=SYM_HI.ADD /V

        appears in the CONFIG.SYS file before the IDE device driver statement.

     b. Boot the system using the floppy drive and installation diskettes to the 
        F3=Command Prompt screen. Use the tedit.exe editor to edit the CONFIG.SYS 
        file. Move the BASEDEV=SYM8XX.ADD /V and/or the BASEDEV=SYM_HI.ADD /V 
        statement(s) to the last line in the CONFIG.SYS file.

     c. Restart your system. 
Download Driver Pack

How To Update Drivers Manually

After your driver has been downloaded, follow these simple steps to install it.

  • Expand the archive file (if the download file is in zip or rar format).

  • If the expanded file has an .exe extension, double click it and follow the installation instructions.

  • Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.

  • Find the device and model you want to update in the device list.

  • Double-click on it to open the Properties dialog box.

  • From the Properties dialog box, select the Driver tab.

  • Click the Update Driver button, then follow the instructions.

Very important: You must reboot your system to ensure that any driver updates have taken effect.

For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.

server: web4, load: 1.24