*****************************************************************************
* *
* 32-Bit PCI Fast Ethernet Adapter *
* *
* NDIS/2 Driver for SUN PC-NFS *
* *
*****************************************************************************
The driver named RTSND contained in the directory \NDIS2 conform to the
Network Driver Interface Specification (NDIS) defined by Microsoft/3Com.
NDIS/2 Driver Installation on SUN PC-NFS
========================================
1. Edit the CONFIG.SYS file to include the following command line, and
reboot the PC:
Device=c:\dos\ansi.sys
2. Insert the PC-NFS Installation diskette into the PC's floppy drive.
Type the following from DOS and press <Enter> to bring up the PC-NFS
installation screen:
INSTALL <Enter>
3. Follow screen prompts to configure your screen display. For example, press
<M> to choose mono display, or press <C> to choose color display, or press
<ESC> to cancel the installation.
4. When the "Install the Basic PC-NFS files" window appears on screen, select
"Install Full PC-NFS" from the choice list.
5. "Specify the target PC-NFS installation directory," by typing the
appropriate path in the field provided. For example, C:\NFS. Then press
<Enter> to continue.
6. Carefully read and respond to each prompt that appears on screen,
indicating the suitable selections for your system.
7. When you reach the prompt that reads,
"Configure an Ethernet network connection,"
choose "Ethernet" from the choice list. Then press <Enter> to confirm your
choice.
8. Choose the network adapter you will use. Select "NDIS" from the list shown
onscreen. Then press <Enter> to confirm your choice.
9. Follow screen instructions to complete the process. You will be prompted
to insert some PC-NFS distribution diskettes. And during the process,
files from the diskettes will be copied into your hard disk drive.
10. When prompted to update your AUTOEXEC.BAT and CONFIG.SYS files, press "Y".
11. Your system will prompt you when the installation process is complete.
It will display the following message,
"PC-NFS installation is complete."
12. The system will create two subdirectories in the destination drive,
namely, \LANMAN and \NFS.
13. Create the NETWORK.BAT, DRIVES.BAT and HOSTS files. Specify the PC name,
IP address, server name and server IP address in these files. See the
section on Sample Configuration Files for examples.
14. Copy the NETWORK.BAT, DRIVES.BAT and HOSTS files into the \NFS directory
of your server.
15. Copy the RTSND.DOS file from the \NDIS2\DOS of your driver diskette to
the newly created subdirectory (\LANMAN) on your destination drive.
16. Edit the CONFIG.SYS file using a text editor. Add the following command
line before the NFS_NDIS driver specification:
DEVICE=C:\LANMAN\RTSND.DOS
17. Edit the PROTOCOL.INI file in the \LANMAN directory, replacing the
following:
a. Replace the section name [your-mac-module] with [RTSND_NIF]
b. Replace the command line "drivername = YOURMAC$" with
"drivername = RTSND$"
c. Replace the command line "bindings = YOUR-MAC-MODULE"
with "bindings = RTSND_NIF"
d. Assign the media type and line speed as used in sample
PROTOCOL.INI file.
18. Reboot your computer. Then start the application you need.
For example:
a. Run NFSCONF.EXE to configure the system, such as
mounting a virtual drive E:
b. Run TELNET.EXE to do terminal emulation
Sample Configuration Files
--------------------------
1. NETWORK.BAT
REM stc* is a sample PC-NFS workstation name
REM test1 is a sample PC-NFS server address
NET START RDR stc*
NET PCNFSD test1
NET NAME stc*
2. DRIVES.BAT
REM specify connections to remote directory
NET USE l:test1:/usr2/down
NET USE k:test1:/mnt
3. HOSTS
REM specify gateway address
192.72.24.201 <gateway # updated>
REM specify workstation's IP address
192.72.24.102 stc
REM specify server's IP address
192.72.24.202 test1
4. CONFIG.SYS
Device=c:\dos\himem.sys
shell=c:\command.com /P /E:526
dos=high, UMB
rem ----pcnfs install
Device=c:\dos\ansi.sys
DEVICE=C:\NFS\PCNFS.SYS /m
DEVICE=C:\NFS\SOCKDRV.SYS
REM Specify PROTOCOL.INI directory
DEVICE=C:\LANMAN\PROTMAN.SYS /i:C:\LANMAN
REM NDIS driver name
device=C:\LANMAN\RTSND.DOS
DEVICE=C:\LANMAN\NFS-NDIS.SYS
FILES=50
BUFFERS=50
LASTDRIVE=v
STACKS=9,256
5. PROTOCOL.INI file at the \LANMAN directory
[protocol manager]
drivername = PROTMAN$
[RTSND_NIF]
drivername = RTSND$
[NFS-NDIS]
drivername = NFSLINK$
bindings = RTSND_NIF
6. AUTOEXEC.BAT
...
SET TZ=PST8
SET path=C:\;C:\NFS;C:\LANMAN
SET NFSDRIVE=D
REM Add the following line to bind NDIS driver
C:lanman\netbind
PRT *
REM Execute application you need, e.g. NFSRUN
NFSNET INIT
NFSRUN
----
All trademarks or brand names mentioned are properties
of their respective companies.
Download Driver Pack
After your driver has been downloaded, follow these simple steps to install it.
Expand the archive file (if the download file is in zip or rar format).
If the expanded file has an .exe extension, double click it and follow the installation instructions.
Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.
Find the device and model you want to update in the device list.
Double-click on it to open the Properties dialog box.
From the Properties dialog box, select the Driver tab.
Click the Update Driver button, then follow the instructions.
Very important: You must reboot your system to ensure that any driver updates have taken effect.
For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.