readme.txt Driver File Contents (SS020750.zip)

SANSurfer Version 2.07.50 Release
50142-07 Rev. H

System Overview
_______________

Thank you for using the QLogic SANSurfer Application to manage your QLogic
SANBox family of Fibre Channel switch products. These notes describe
Release 2.07.50 of the SANSurfer Application.

The QLogic SANSurfer Application is Java-based and on Windows operates with 
Netscape 4.6 and Internet Explorer 5.0 with Release 5.0.0.3309 or Release 
5.0.0.3167 of the Java VM Windows 95/98/NT.  It also operates as a Java 
Application on Solaris 2.8 and 2.7. JRE version 1.2.2_05a is required on
Solaris.

Version 2.07.50 is a corrective code release of the Gui. It contains no new
features, but is substantially more stable than Version 2.07.39.

Two significant user interface changes will be apparent in this release:
	
1) The Fabric window now shows only a single fabric line. The system 
administrator will enter one fabric and its IP address on the "Fabric" screen.
If the user wishes to save this fabric for subsequent viewing and configuration,
the user pulls down the file menu and chooses "save as". The user follows these
steps for each fabric of interest. The user can easily track multiple fabrics 
from one installation of the Gui. To switch among fabrics, the administrator 
uses the file menu and loads in turn, the file of interest. 
	
2) A busy cursor will appear upon entering each window, which will prevent the
user from performing any operation which would make the Gui unstable as a result
of having incomplete data at the time the operation was requested.

__________________
Release Components
__________________


QLogic.htm           -|
admin.htm             |
admin_v20750.jar      |
MKII_v20750.jar       |
QLogic_v20750.jar     |>   Sansurfer componets to load onto
MKII_v20750.cab       |    a SANbox switch
QLogic_v20750.cab     |
Admin_v20750.cab      |
version.txt          -|

Gosleep.exe	    - Executable used in the install process	
setgui_QLogic.bat   - Batch file used for installing the WEBGUI on a switch	
Tftp.exe	    - TFTP program (used in Switch install if on Windows 95/98)
QLGCWsmgr           - Package file, for installing the SANSurfer on Solaris	
readme.txt	    - This document   
_____________________
Software Installation
_____________________

There are 2 ways to install the SANSurfer application.

1. Install to a Sun SPARC System. 

    Copy the QLGCWsmgr to a local disk
    enter pkgadd -d QLGCWsmgr


2. Install to a SANBox Switch.

    In a DOS window under Windows, Enter: 
    setgui_QLogic <IP address of switch>   

    This will copy all necessary files to the switch.



If you have any questions or problems, please call QLogic
Customer Support:
Phone: (952) 932-4040
FAX: (952) 932-4018   Attn: Customer Support
Email: switchsupport@qlogic.com

________________________________________________________________
Changes in this release include: 
________________________________________________________________

2.07.40

1)  Fixed bug #915 -- Add generic failure message to faceplate display when a 
    faceplate parameter change is rejected by the switch for any reason.

2)  Fixed bug #917 -- Fix netscape error where reading in a remotely saved 
    topology causes an exception.

3)  Fixed bug -- Switch icon was incorrectly colored when switch was disconnected
    from fabric.

4)  Fixed bug #913 -- Fix condition where switch was taken offline, then back 
    online and the zoning configuration type wasn't being read in.

5)  Fixed bug #910 -- Display a popup when a switch has been discovered to have
    been disconnected from the fabric.  This msg is only seen if the failed 
    message was a write of some sort.

6)  Fixed bug -- Display switches in the tree with the correct effect color
    depending on the state within the fabric.

7)  Fixed bug #909 -- Avoid Netscape hang when entering zoning display and 
    selecting zonenumber immediately.

8)  Fixed bug #918 -- If zoning type isn't known for the switch, do not attempt
    to display port types or devices.

2.07.41
 
1)  Put in a delay to keep user from re-accessing the faceplate for 15 seconds
    after doing a switch reset.
 
2)  Take out "Save complete" that would display on status panel whether anything
    was successfully saved or not.

3)  Correct the problem of the Gui switching between port mode, port state, 
    and port tuning views on the faceplate after you do a refresh.

4)  Refresh on topology screen will no longer cause a red offline switch to 
    appear to be online.

5)  Disable menubar when busy cursor is set.

6)  Made cursor busy during flash download.

7)  Fixed bug #914 -- Can't see a switch's devices in the device list of the 
    zoning window when that switch is no longer part of the fabric.

8)  Fix duplicate links appearing on topology screen.

9)  Fixed bug #820 -- Gui hangs after opening the fabric, disconnecting the 
    only TCP/IP connection, and then remove a zone member.

10) Gui hang prevention.

11) Restrict users to one IP address per line.

12) Fix for fabrics coming up with red icon.

13) Fix for name server not completing.

14) Upped busy cursor wait times on faceplate and topology.

15) Fix Gui hang in topology.

2.07.42

1)  Changes to prevent Gui from getting confused when chassis ID's are changed.

2)  Correct bb credit donor problem.

3)  Login fixes so Gui no longer requires an app.dat file to be on the local
    workstation when you are running off the switch.

2.07.43

1)  Busy cursor changes for busy cursor not always showing up first time into
    screen.

2)  Added busy cursor to zoning window to try to prevent Gui hang when pulldown
    is accessed before window is done drawing.

3)  Added change to put up correct topology name under switch faceplate.

2.07.44

1)  Fixed bug #1125 -- Zoning problem description out of sync.  Allow only 
    one fabric line.

2)  Queuing problem fix.

3)  Null ptr exception fix.

4)  Fixed bug #1126 -- Put out warning msg when you can't talk to fabric.

2.07.45

1)  Moved topo reset cmd to come before h/w reconfig.

2)  Changed titles on Fabrics & Topology screens.

3)  Grayed out "Open Fabrics" on all screens except the Fabrics screen.

4)  Pop up dialog box if user tries to apply zoning changes when IP connection
    to source IP is down.

5)  Catching ArrayOutOfBoundsException when writing to socket.

6)  Fix check for dup chassis ID.

2.07.46

2.07.47

1)  Omit rescan to switches if the queue is clogged.

2)  Omit request zoning info if the switch is "Unplugged".

2.07.48

1)  Changes to prevent continuous beeping when Gui can't talk to switch.

2)  Changed all "Ancor" strings to "QLogic".

3)  Asks user if he wants to reset switch after changing stage type, so 
    you don't have to go back and do it yourself.

4)  Fix so that when you drill into a port when in HUB mode, you get it 
    showing up as SL_PORT, not Unknown.

5)  Fix for disappearing devices in tree on topology.

6)  Fix for unnecessary reset.

7)  Fix gray out next/prev buttons on zoning window after a window resize.

8)  Fixed a bug in delete zone for SL zoning where the shift-up of zones 
    didn't work correctly.

9)  Fixed a bug in Clear/Delete All Zones in SL zoning that left some ports 
    in zones.

10) Put a title on File Load/Save Dialog boxes.

11) Clear up problem with filenames ending in "*default.fab".

12) Fix null ptr exception when zeroing port counts in faceplate.

13) Make status field at bottom 2 lines high so msgs don't get cut off.

14) Fixes for saving/restoring zoning templates for SL zoning.

15) Reduced number of line breaks in some error/warning messages.

16) Fixed status msgs that appear at bottom of screen.

17) Fixed loopback testing.

18) Fixed "No reply from switch" msg remaining at bottom of fabric screen 
    even when switch is accessible.

19) Fixed a null ptr problem.

20) Fixed a Gui hang problem relating to dialog boxes & busywait cursor.

21) Explicitly send additional "stop test" util msg to make sure loopback
    testing stops when user clicks on StopTest icon.

22) Allow user to specify test length, frame size, and pattern for loopback
    testing.

2.07.49

1)  Fixes for loopback testing problem where Gui would fail to pop up testing
    window after a previous test completed (TEST_OUTOFTIME).

2)  Disallow simultaneous testing on multiple ports.

3)  Change Zoning to fix problem where Gui hangs when user accesses the pulldown
    choice boxes while screen is redrawing.

4)  Change made in Faceplate to prevent loss of device login when changing 
    port on/offline or changing from fabric to SL. 

5)  Made a change to fix problem with zoning where ports previously clicked on
    get added to the zone, even though they are not highlighted as being selected
    at the time of the APPLY.

6)  Fixed problem of not being able to remove a port from a zone(with SL zoning).

7)  Fixed problem with polling thread. This clears up two bugs:
      #1306 "Save complete, but failed writing to 1 switch"
      #1312 "A switch has failed to respond during the zoning operation. Zoning
      operation failed."

8)  Fixed bugs #1202 & 1310 --  No longer printing out "Exception caught 
    java.io.InvalidClassException: MKII.Switch;  Local class not compatible..."
    This is the result of a newer version of Gui reading in a fabric file created
    by an older version of the Gui, and does not cause a problem for the user. 

9)  Fixed bug #1315 --  When user tries to load a zoning template from an 8 port
    into a 16 port or vice versa and would then get an error msg repeated many
    times.  Now user should only see error msg once.

10) Fixed bug #1304 -- Enabled beacon menu option in faceplate even if switch is 
    in Hub mode.

11) Fixed bug #1323 -- After clearing all zones, should no longer see "add to 
    zone" text under Orphan zone. Also related to this bug, fixes were made so
    that you should be able to add ports to several zones before hitting apply,
    and they should all be saved. 

12) Fix related to bug #1315 -- Gui should no longer allow zoning templates from 
    an 8 port switch to be saved to a 16 port switch (or vice-versa). Side 
    effect of this change is that zoning templates created with older versions 
    of the Gui will now be incompatible with zoning templates created from this
    version and its successors.

13) Fixed bug #1320 -- Put up a msg and a busy cursor while trying to resolve IP
    addr in the fabric window.

14) Fixed bug #1311 -- If you hit Cancel on the testing parameters dialog, you no
    longer have to click on StopTests icon to change its state. Also, no longer  
    have to click on StopTests to remove test results window after test 
    completes. Next refresh will do that. Still prevents user from leaving Port
    window while test is running- that is necessary to prevent other problems.

15) Fixed bug # 1269 -- Now catching an exception that would get thrown when user
    tried to delete multiple users at once. It only works to remove a single user
    at a time.

16) Fixed bug #1169 -- Gui now forces expected suffixes on the end of filenames.
    For example, if you save a zoning template, the Gui will append .tpl to the 
    filename. You should see all *.tpl files when you try to restore a zoning 
    template. You will NOT see all the files in the directory running on the Sun
    unless you click on Update, but that is expected.  You should see any *.tpl 
    files if there are any present.

17) Fixed bug #1320 -- Additional modification made to disable toolbar buttons 
    while Gui is trying to resolve IP address.

18) Fixed bug #1369 -- Change made to correct problem where "Clear All Zones" 
    does not work for Name Server, Broadcast, and Hard Zones.  

19) Fix bug where the Done button on the zone description edit window became 
    inoperative after user uses Back toolbar button to leave zoning with edit
    window open amd then returns to zoning. A minor related fix prevents user
    from changing to other zones while the zone description edit window is open.

20) Online help has been updated to reflect Gui changes.

21) Fix problem where busy cursor did not prevent user from accessing zone type
    pulldown after first entering zoning screen.

22) Fixed bug #1392 -- Disable next/prev buttons on topology screen because it
    only allows a single fabric.

23) Prevent a null pointer exception when a user enters an invalid loop back
    testing parameter the first time testing is started.

24) Rebuilt the Fabric.gif file for QLogic.

25) Prevent a null ptr exception from being thrown when changing stage type on
    a switch.

26) Changed string on login screen from "Username" to "User Name".

27) Changed "switch no longer appears to be in fabric" msg so that it should 
    show up on a single line, and not get cut off the display.

28) Fixed bug #794 -- Proxy server is not getting newest Gui files.



Download Driver Pack

How To Update Drivers Manually

After your driver has been downloaded, follow these simple steps to install it.

  • Expand the archive file (if the download file is in zip or rar format).

  • If the expanded file has an .exe extension, double click it and follow the installation instructions.

  • Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.

  • Find the device and model you want to update in the device list.

  • Double-click on it to open the Properties dialog box.

  • From the Properties dialog box, select the Driver tab.

  • Click the Update Driver button, then follow the instructions.

Very important: You must reboot your system to ensure that any driver updates have taken effect.

For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.

server: web1, load: 0.70