OEMSETUP.INF Driver File Contents (perc-cerc-w2k3-6.41.2.32-A03.exe)

;  -- This file contains descriptions of the MegaRAID family 
;             of RAID Controllers
;
; Copyright © 2001, LSI Logic Corp.,
[version]
Signature="$Windows NT$"
Class=SCSIAdapter
ClassGUID={4D36E97B-E325-11CE-BFC1-08002BE10318}
Provider=%Dell%
CatalogFile=mraid35x.cat
DriverVer=12/11/2003,6.41.2.32


     
[DestinationDirs]
DefaultDestDir = 12 ; DIRID_DRIVERS


[ControlFlags]
;
; Exclude the following PnP devices from Select Device list.
; 
ExcludeFromSelect = PCI\VEN_8086&DEV_1960&SUBSYS_11121111
ExcludeFromSelect = PCI\VEN_8086&DEV_1960&SUBSYS_11111111
ExcludeFromSelect = PCI\VEN_8086&DEV_1960&SUBSYS_09A0101E
ExcludeFromSelect = PCI\VEN_8086&DEV_1960&SUBSYS_11111028
ExcludeFromSelect = PCI\VEN_8086&DEV_1960&SUBSYS_04671028 
ExcludeFromSelect = PCI\VEN_101E&DEV_1960&SUBSYS_04711028 
ExcludeFromSelect = PCI\VEN_101E&DEV_1960&SUBSYS_04931028 
ExcludeFromSelect = PCI\VEN_101E&DEV_1960&SUBSYS_05111028 
 
ExcludeFromSelect = PCI\VEN_101E&DEV_1960&SUBSYS_04751028 
ExcludeFromSelect = PCI\VEN_1000&DEV_1960&SUBSYS_05181028 
ExcludeFromSelect = PCI\VEN_1000&DEV_1960&SUBSYS_05201028 
ExcludeFromSelect = PCI\VEN_1028&DEV_000E&SUBSYS_01231028 
ExcludeFromSelect = PCI\VEN_1028&DEV_000F&SUBSYS_013B1028 
ExcludeFromSelect = PCI\VEN_1028&DEV_000F&SUBSYS_014A1028 
ExcludeFromSelect = PCI\VEN_1028&DEV_000F&SUBSYS_014C1028 
ExcludeFromSelect = PCI\VEN_1028&DEV_000F&SUBSYS_014D1028 
ExcludeFromSelect = PCI\VEN_1028&DEV_0013&SUBSYS_016C1028 
ExcludeFromSelect = PCI\VEN_1028&DEV_0013&SUBSYS_016D1028 
ExcludeFromSelect = PCI\VEN_1028&DEV_0013&SUBSYS_016E1028 
ExcludeFromSelect = PCI\VEN_1028&DEV_0013&SUBSYS_016F1028 
ExcludeFromSelect = PCI\VEN_1028&DEV_0013&SUBSYS_01701028 
ExcludeFromSelect = PCI\VEN_1000&DEV_0408&SUBSYS_00021028 
ExcludeFromSelect = PCI\VEN_1000&DEV_0408&SUBSYS_00011028 


     
[Manufacturer]
%DELL%=DELL
     

[DELL]

;DELL 438
%Dell.DeviceDesc% = mraid35x_Inst, PCI\VEN_8086&DEV_1960&SUBSYS_11121111

;DELL 466
%Dell.DeviceDesc% = mraid35x_Inst, PCI\VEN_8086&DEV_1960&SUBSYS_11111111
%Dell.DeviceDesc% = mraid35x_Inst, PCI\VEN_8086&DEV_1960&SUBSYS_09A0101E
%Dell.DeviceDesc% = mraid35x_Inst, PCI\VEN_8086&DEV_1960&SUBSYS_11111028

;DELL 467
%Dell467.DeviceDesc% = mraid35x_Inst, PCI\VEN_8086&DEV_1960&SUBSYS_04671028 

;DELL 471/503
%Dell471.DeviceDesc% = mraid35x_Inst_reboot, PCI\VEN_101E&DEV_1960&SUBSYS_04711028 


;DELL 493/494
%Dell493.DeviceDesc% = mraid35x_Inst_reboot, PCI\VEN_101E&DEV_1960&SUBSYS_04931028 


;Dell IDE 100 (511)
%Dell511.DeviceDesc% = mraid35x_Inst, PCI\VEN_101E&DEV_1960&SUBSYS_05111028 

;PERC 3/SC (DELL 475)
%Dell475.DeviceDesc% = mraid35x_Inst, PCI\VEN_101E&DEV_1960&SUBSYS_04751028 

;PERC 4/Di 0123
%DellROM.DeviceDesc% = mraid35x_Inst, PCI\VEN_1028&DEV_000E&SUBSYS_01231028 

;PERC 4/DC (DELL 518)
%Dell518.DeviceDesc% = mraid35x_Inst, PCI\VEN_1000&DEV_1960&SUBSYS_05181028 


;PERC 4/SC (DELL 520)
%Dell520.DeviceDesc% = mraid35x_Inst, PCI\VEN_1000&DEV_1960&SUBSYS_05201028 

;PERC 4/Di 013B
%DellROM.DeviceDesc% = mraid35x_Inst, PCI\VEN_1028&DEV_000F&SUBSYS_013B1028 

;PERC 4/Di 014A
%DellROM.DeviceDesc% = mraid35x_Inst, PCI\VEN_1028&DEV_000F&SUBSYS_014A1028 

;PERC 4/Di 014C
%DellROM.DeviceDesc% = mraid35x_Inst, PCI\VEN_1028&DEV_000F&SUBSYS_014C1028 

;PERC 4/Di 014D
%DellROM.DeviceDesc% = mraid35x_Inst, PCI\VEN_1028&DEV_000F&SUBSYS_014D1028 

;PERC 4e/Si
%Dell16C.DeviceDesc% = mraid35x_Inst, PCI\VEN_1028&DEV_0013&SUBSYS_016C1028 

;PERC 4e/Di
%Dell16DE.DeviceDesc% = mraid35x_Inst, PCI\VEN_1028&DEV_0013&SUBSYS_016D1028 
%Dell16DE.DeviceDesc% = mraid35x_Inst, PCI\VEN_1028&DEV_0013&SUBSYS_016E1028 
%Dell16DE.DeviceDesc% = mraid35x_Inst, PCI\VEN_1028&DEV_0013&SUBSYS_016F1028
%Dell16DE.DeviceDesc% = mraid35x_Inst, PCI\VEN_1028&DEV_0013&SUBSYS_01701028  

;PERC 4e/DC
%Dell002.DeviceDesc% = mraid35x_Inst, PCI\VEN_1000&DEV_0408&SUBSYS_00021028 

;PERC 4e/SC
%Dell001.DeviceDesc% = mraid35x_Inst, PCI\VEN_1000&DEV_0408&SUBSYS_00011028 



[mraid35x_Inst_reboot]
CopyFiles = @mraid35x.sys
Reboot

[mraid35x_Inst]
CopyFiles = @mraid35x.sys
     
[mraid35x_Inst.HW]
DelReg = LegacyScsiportValues

[mraid35x_Inst_reboot.HW]
DelReg = LegacyScsiportValues

[mraid35x_Inst.Services]
AddService = mraid35x, %SPSVCINST_ASSOCSERVICE%, mraid35x_Service_Inst,Miniport_EventLog_Inst

[mraid35x_Inst_reboot.Services]
AddService = mraid35x, %SPSVCINST_ASSOCSERVICE%, mraid35x_Service_Inst,Miniport_EventLog_Inst


[mraid35x_Service_Inst]
ServiceType    = %SERVICE_KERNEL_DRIVER% 
StartType      = %SERVICE_BOOT_START% 
ErrorControl   = %SERVICE_ERROR_NORMAL% 
ServiceBinary  = %12%\mraid35x.sys
LoadOrderGroup = SCSI Miniport
AddReg         = pnpsafe_pci_addreg
AddReg         = DriverInfoAddReg     
     
;************************************************************* 
;The EventLog entries are the same for all SCSI miniports. 
[Miniport_EventLog_Inst]
AddReg = Miniport_EventLog_AddReg
     
[pnpsafe_pci_addreg]
HKR, "Parameters\PnpInterface", "5", 0x00010001, 0x00000001
HKR, "Parameters\Device", "NumberOfRequests", 0x00010001, 0x00000080
HKLM,"System\CurrentControlSet\Services\Disk","TimeOutValue",0x00010001,0x00000028

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_1960&subsys_11121111,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_1960&subsys_11121111,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_1960&subsys_11111111,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_1960&subsys_11111111,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_1960&subsys_09A0101E,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_1960&subsys_09A0101E,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_1960&subsys_11111028,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_1960&subsys_11111028,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_1960&subsys_04671028,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_1960&subsys_04671028,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_101E&dev_1960&subsys_04931028,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_101E&dev_1960&subsys_04931028,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_101E&dev_1960&subsys_05111028,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_101E&dev_1960&subsys_05111028,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_101E&dev_1960&subsys_04711028,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_101E&dev_1960&subsys_04711028,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_101E&dev_1960&subsys_04751028,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_101E&dev_1960&subsys_04751028,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_1960&subsys_05181028,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_1960&subsys_05181028,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_1960&subsys_05201028,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_1960&subsys_05201028,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1028&dev_000E&subsys_01231028,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1028&dev_000E&subsys_01231028,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1028&dev_000F&subsys_013B1028,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1028&dev_000F&subsys_013B1028,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1028&dev_000F&subsys_014A1028,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1028&dev_000F&subsys_014A1028,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1028&dev_000F&subsys_014C1028,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1028&dev_000F&subsys_014C1028,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1028&dev_000F&subsys_014D1028,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1028&dev_000F&subsys_014D1028,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1028&dev_0013&subsys_016C1028,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1028&dev_0013&subsys_016C1028,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1028&dev_0013&subsys_016D1028,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1028&dev_0013&subsys_016D1028,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1028&dev_0013&subsys_016E1028,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1028&dev_0013&subsys_016E1028,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1028&dev_0013&subsys_016F1028,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1028&dev_0013&subsys_016F1028,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1028&dev_0013&subsys_01701028,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1028&dev_0013&subsys_01701028,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0408&subsys_00021028,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0408&subsys_00021028,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0408&subsys_00011028,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0408&subsys_00011028,Service,,%Service%


     
[Miniport_EventLog_AddReg]
HKR,,EventMessageFile,%REG_EXPAND_SZ%,%%SystemRoot%%\System32\IoLogMsg.dll 
HKR,,TypesSupported,%REG_DWORD%,7

[LegacyScsiportValues]
HKR,Scsiport

[DriverInfoAddReg]
; This section is added to all INFs to add registry entries for Driver Info.
HKLM,Software\InstalledOptions\%DriverOEM%\%DriverFamily%\%DriverMfgr%\%DriverProduct%,Description,,%DriverDescription%
HKLM,Software\InstalledOptions\%DriverOEM%\%DriverFamily%\%DriverMfgr%\%DriverProduct%,CurrentVer,,%DriverOEMVersion%
HKLM,Software\InstalledOptions\%DriverOEM%\%DriverFamily%\%DriverMfgr%\%DriverProduct%,Ver_%DriverOEMVersion%,,%DriverVersionID%
HKLM,Software\InstalledOptions\%DriverOEM%\%DriverFamily%\%DriverMfgr%\%DriverProduct%,BaseDriverFileName,,%BaseDriverFileName%
HKLM,Software\InstalledOptions\%DriverOEM%\%DriverFamily%\%DriverMfgr%\%DriverProduct%,BaseDriverFileVersion,,%BaseDriverFileVersion%



[SourceDisksNames]
1 = %SOURCE_DISK%,\mraid35x.sys,,

[SourceDisksFiles]
mraid35x.SYS = 1,,11136,,,,,,

[Strings]

;---------------------Dell-----------------------------
DELL="DELL"
Dell467.DeviceDesc  = "Dell PERC 2/DC RAID Controller" 
Dell.DeviceDesc	    = "Dell PERC 2/SC RAID Controller" 
Dell471.DeviceDesc  = "Dell PERC 3/QC RAID Controller" 
Dell493.DeviceDesc  = "DELL PERC 3/DC & PERC 3/DCL RAID Controller" 
Dell511.DeviceDesc  = "DELL CERC ATA 100/4ch RAID Controller" 
Dell475.DeviceDesc  = "DELL PERC 3/SC RAID Controller" 
DellROM.DeviceDesc  = "DELL PERC 4/Di RAID On Motherboard Driver" 
Dell518.DeviceDesc  = "DELL PERC 4/DC RAID Controller" 
Dell520.DeviceDesc  = "DELL PERC 4/SC RAID Controller"
Dell16C.DeviceDesc  = "DELL PERC 4e/Si RAID Controller"
Dell16DE.DeviceDesc  = "DELL PERC 4e/Di RAID Controller"
Dell002.DeviceDesc  = "DELL PERC 4e/DC RAID Controller"
Dell001.DeviceDesc  = "DELL PERC 4e/SC RAID Controller"


DriverMfgr           = "LSI Logic Corporation"
DriverVersionID      = "6.41.2.32"
DriverOEM            ="Dell"
DriverFamily         ="Storage"
DriverProduct        ="PERC 4/SC; 4/DC; 4/Di; 2/SC; 2/DC; 3/SC; 3/DC; 3/QC; CERC ATA100/4ch - Device Drivers"
DriverDescription    ="PERC Controller Support"
DriverOEMVersion     ="A01"
BaseDriverFileName   ="mraid35x.SYS"
BaseDriverFileVersion="6.41.2.32"
SOURCE_DISK          ="Dell PERC RAID Driver" 
Service = "mraid35x"
ClassGUID = "{4D36E97B-E325-11CE-BFC1-08002BE10318}"
     
;******************************************* 
;Handy macro substitutions (non-localizable) 
SPSVCINST_ASSOCSERVICE = 0x00000002
SERVICE_KERNEL_DRIVER  = 1
SERVICE_BOOT_START     = 0
SERVICE_ERROR_NORMAL   = 1
REG_EXPAND_SZ          = 0x00020000
REG_DWORD              = 0x00010001
Download Driver Pack

How To Update Drivers Manually

After your driver has been downloaded, follow these simple steps to install it.

  • Expand the archive file (if the download file is in zip or rar format).

  • If the expanded file has an .exe extension, double click it and follow the installation instructions.

  • Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.

  • Find the device and model you want to update in the device list.

  • Double-click on it to open the Properties dialog box.

  • From the Properties dialog box, select the Driver tab.

  • Click the Update Driver button, then follow the instructions.

Very important: You must reboot your system to ensure that any driver updates have taken effect.

For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.

server: web2, load: 1.09