*******************************************************************
*README.TXT Release Notes for Plug and Play Kit *
* for MS-DOS(R) *
*Release 1.43 May 1995 *
*******************************************************************
Introduction
============
This kit contains Release 1.43 of the Plug and Play Kit for MS-DOS.
This release of the Plug and Play Kit for MS-DOS supersedes
all previous releases. The components of this kit are:
Plug and Play Configuration Manager (CM) for MS-DOS
Provides configuration services to real-mode and protected-
mode drivers and to applications in MS-DOS environments.
Plug and Play ISA Configuration Utility (ICU) for MS-DOS
Provides a way to assign system resources to add-in cards
before the card is installed. This assignment avoids
resource conflicts and keeps track of system resources so
that Plug and Play cards do not conflict with non-Plug
and Play cards in a system.
*******************************************************************
*Plug and Play Configuration Manager (CM) *
*******************************************************************
The Plug and Play Configuration Manager provides all of the
functionality defined in the "Plug and Play Device Driver
Specification for Microsoft(R) Windows(TM) and MS-DOS(R)".
The Configuration Manager also complies with the specifications
and definitions in:
"Plug and Play ISA Specification", Version 1.0a
from Intel Corporation and Microsoft Corporation
"Plug and Play BIOS Specification", Version 1.0a
from Intel Corporation, Compaq Computer Corporation,
Phoenix Technologies, Ltd., and Microsoft Corporation
"Plug and Play BIOS Extensions Guide", Version 1.1
from Intel Corporation
"PCI BIOS Specification", Version 2.1, from Intel Corporation
Configuration Manager Limitations
=================================
Please be aware that this release of the Plug and Play
Configuration Manager for MS-DOS has the following
limitations:
- The default installation of the MS-DOS CM driver invokes the driver
with the 'lock' device function of the CM provided by the
CM_LockConfig and CM_UnlockConfig functions unavailable to PC
add-in install programs running in a real-mode MS-DOS environment.
If the CM driver for Windows is also installed, the CM lock
functionality is always available under Windows,
including the Windows V86 DOS. If this functionality is needed,
add the /LOCK parameter to the line in your CONFIG.SYS file that
invokes the CM driver, DWCFGMG.SYS.
CM_LockConfig and CM_UnlockConfig are unrelated to the locking
options available with ECU or ICU utilities.
- In the absence of the Intel Plug and Play BIOS extensions, Plug
and Play boot devices are not reconfigured by the Configuration
Manager.
- Calls to the Configuration Manager do not work during
sys_critical_init.
******************************************************************
*Plug and Play Kit ISA Configuration Utility (ICU) *
******************************************************************
See the ISA Configuration Utility User's Guide for details on
using the Plug and Play ICU.
NOTE
The ISA Configuration Utility is for ISA systems
only. Do not run it on EISA systems. To configure
EISA systems, use an EISA Configuration Utility.
ICU Limitations
===============
Please be aware that this release of the Plug and Play
ISA Configuration Utility for MS-DOS has the following
limitations:
- Some portions of the ICU may not fit on the screen if you are using
VGA resolution. If this happens, you can see the missing information
by moving the displayed item back onto the screen. Click on the
title bar of the displayed item, and move the item to the desired
location.
- Double clicking to select an item in a list is not supported.
- If any PCI devices are locked, the ICU may fail when trying to
reconfigure other PCI devices. To work around this limitation,
unlock all PCI devices while adding or modifying other cards.
You may lock the PCI devices again before saving the configuration.
- Pressing the F1 key invokes the ICU help facility from the
ISA Configuration Utility window (the main window) only.
- When you are modifying a function of a Plug and Play card in
preparation for locking it, you might see a conflict message
that indicates the card is conflicting with itself. Try
reconfiguring the card functions in a different order.
- If a function has two or more resource types that must be
configured together, the ICU might not be able to configure
that function, even though there might be a valid configuration
available. See the discussion on resolving conflicts in the
Troubleshooting section of the ICU User's Guide for ways to
successfully configure functions in this category.
- When you pick a resource for a new card that is currently used
by an existing card, the ICU reconfigures the Plug and Play ISA
cards first, then the PCI cards. However, PCI cards are
restricted to specific interrupts. Sometimes the configuration
fails because the ICU assigns all the valid PCI interrupts to
the Plug and Play cards, so that it cannot configure the PCI
cards. Use the ICU to reconfigure the Plug and Play cards to
different interrupts, then try again to configure your new
card.
Operational Hints
=================
- Run the MS-DOS installations for the kit components from MS-DOS,
not from an MS-DOS window under Windows.
- The MS-DOS install program on these diskettes is incompatible
with the expanded memory manager. Before installing the Plug
and Play kit for MS-DOS, disable your expanded memory manager.
After you have finished the installation, you can enable the
expanded memory manager again.
- The MS-DOS ICU installation might fail if some Terminate and
Stay Resident (TSR) programs or drivers are resident in memory.
If this happens, remove all TSRs from memory and restart the
install process. Some example TSRs and drivers are: Borland
Side Kick and network drivers that are not loaded from
config.sys.
- You must execute the MS-DOS ICU from MS-DOS only, not from an
MS-DOS window. If you want to use the MS-DOS ICU from an MS-DOS
window, the Windows ICU must also be installed on the system.
- If you are upgrading from a previous version of the ICU,
any user-entered names for unlisted cards are lost and will
have to be re-entered.
- When you save an image file (Save Image File or Save Image File
As.. on the Advanced menu), the icu.ndx index file is not
updated. So if the configuration you saved contained one or
more unlisted cards, when you load the image file you saved,
the card resources for these unlisted cards are in the loaded
configuration image. However, cards of this type might be listed
as "Unknown Card," instead of by the name you assigned
when you added it. You can avoid this behavior by choosing the
Save item on the File menu before you save the image file. In
addition, if you copy the image file to another system, you
must also copy the icu.ndx index file to avoid this behavior.
- After using the ICU load image file operation, you must save the
changes and reboot your system before making any other changes.
If you don't, you will see inconsistent behavior.
- When a PCI or Plug and Play ISA card is modified, the ICU asks
you to verify that the card is configured as shown. This step
is unnecessary; the card will be automatically configured as shown
when the system next boots.
- Configuration Assistance Utility (cassist) operation is
incompatible with Plug and Play cards. Remove all Plug and Play
cards from your system before running cassist. Failure to do so
may result in system failure. Replace the cards after you have
run cassist.
- If you have no mouse, you may experience changes in the keyboard
interface. In most cases you can still traverse buttons, list
boxes and menus in the dialog boxes using the <TAB> key, and select
using the space bar. In the message dialogs, you must use the
up and down arrow keys or page up and page down keys instead
for traversal.
- This release of the ICU includes PCMCIA Revision 2.10 support.
This does not include support for CardBus or DMA, which were added
to the new PC-Card Standard. To enable this support, Card Services
must be running on your system.
*******************************************************************
Trademark and Copyright Citations
=================================
MS-DOS is a registered trademark, and Windows is a trademark of
Microsoft Corporation.
Other names and trademarks are the property of their respective
companies.
<END>
Download Driver Pack
After your driver has been downloaded, follow these simple steps to install it.
Expand the archive file (if the download file is in zip or rar format).
If the expanded file has an .exe extension, double click it and follow the installation instructions.
Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.
Find the device and model you want to update in the device list.
Double-click on it to open the Properties dialog box.
From the Properties dialog box, select the Driver tab.
Click the Update Driver button, then follow the instructions.
Very important: You must reboot your system to ensure that any driver updates have taken effect.
For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.