ÉÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ»
º º
º Microsoft DOS Client Installation Guide º
º Copyright (C) 1997 by PDS. All Rights Reserved. º
º º
ÈÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍͼ
ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
³ GENERAL INFORMATION ³
ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ
Mircosoft DOS Client support both NDIS2 and DOS ODI drivers.
ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
³ INSTALLATION GUIDE ³
ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ
The installation described below is for;
Compex ReadyLINK RL2000-PCI Ethernet Adapter.
Microsoft DOS Client
ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ
1. NDIS2 driver Installation
a) Run SETUP in DISK1.
b) When asked where the software to install, enter the location,
e.g. C:\MSCLIENT
c) Select "Network adapter not shown an list below ..."
d) The Install Driver box appears. Insert driver diskette
into floppy drive and type the path of the NDIS2 driver.
Enter the driver location,
e.g. A:\NDIS2
e) Select "Change Network Configuarion".
f) Select "Add Protocol" and "Microsoft NetBEUI" to add NETBEUI
protocol in.
g) Follow the instruction to complete the installation.
2. DOS ODI Driver Installation
a) Run SETUP in DISK1.
b) When asked where the software to install, enter the location,
e.g. C:\MSCLIENT
c) Select "ODI/NDIS Support Driver".
d) Select "Change Network Configuarion".
e) Select "Add Protocol" and "Microsoft NetBEUI" to add NETBEUI
protocol in.
f) Follow the instruction to complete the installation.
g) Modify PROTOCOL.INI. Change all the lines BINDINGS=ODINSUPMAC
to BINDINGS=RL2000 as shown by the arrows below.
(there should have three lines needed to be modified).
PROCOTOL.INI
------------
[network.setup]
version=0x3110
netcard=odinsupmac,1,ODINSUPMAC,1
transport=ms$nwlink,MS$NWLINK
transport=ms$ndishlp,MS$NDISHLP
transport=ms$netbeui,MS$NETBEUI
lana0=odinsupmac,1,ms$nwlink
lana1=odinsupmac,1,ms$ndishlp
lana2=odinsupmac,1,ms$netbeui
[MS$NWLINK]
FRAME=ETHERNET_802.3
DriverName=nwlink$
BINDINGS=RL2000 <-----
[protman]
DriverName=PROTMAN$
PRIORITY=MS$NDISHLP
[ODINSUPMAC] <---- can be deleted
[MS$NDISHLP]
DriverName=ndishlp$
BINDINGS=RL2000 <-----
[MS$NETBEUI]
DriverName=netbeui$
SESSIONS=10
NCBS=12
BINDINGS=RL2000 <-----
LANABASE=1
i) Copy the following files from A:\DOSODI to C:\NWCLIENT directory
LSL.COM, ODINSUP.COM and RL2000.COM
j) Create or copy NET.CFG from A:\NDIS2 to C:\NWCLIENT
Below is a sample of NET.CFG:
NET.CFG
-------
PROTOCOL ODINSUP
Bind RL2000
BUFFERED
Link driver RL2000
Frame Ethernet_802.2
Frame Ethernet_802.3
Frame Ethernet_II
Frame Ethernet_SNAP
l) Modify AUTOEXEC.BAT. Following is a sample for it.
AUTOEXEC.BAT
------------
c:\NWclient\lsl
c:\NWclient\RL2000
c:\MSClient\net initialize } These lines are added by
C:\MSClient\nwlink } Microsoft DOS Client
c:\MSClient\odinsup } during installation
c:\MSClient\netbind }
c:\MSClient\net start }
** Note:- Do not type in the character "}" and the message that follows
them. They are added to explain a point only.
m) Installation completed.
Download Driver Pack
After your driver has been downloaded, follow these simple steps to install it.
Expand the archive file (if the download file is in zip or rar format).
If the expanded file has an .exe extension, double click it and follow the installation instructions.
Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.
Find the device and model you want to update in the device list.
Double-click on it to open the Properties dialog box.
From the Properties dialog box, select the Driver tab.
Click the Update Driver button, then follow the instructions.
Very important: You must reboot your system to ensure that any driver updates have taken effect.
For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.