ÉÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ» º º º Microsoft DOS Client 3.0 Installation Guide º º Copyright (C) 1997 by PDS. All Rights Reserved. º º º ÈÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍͼ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿ ³ GENERAL INFORMATION ³ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ Mircosoft DOS Client support both NDIS2 and DOS ODI drivers. ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿ ³ INSTALLATION GUIDE ³ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ The installation described below is for; Compex LinkPort/TX16 10/100 Fast Ethernet Adapter. Microsoft DOS Client ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ 1. NDIS2 driver Installation ------------------------- a) Run SETUP in DISK1 og Microsoft Client 3.0 for DOS. b) When asked where the software to install, enter the location, e.g. C:\MSCLIENT c) Select "Network adapter not shown an list below ..." d) The Install Driver box appears. Insert Compex driver diskette into floppy drive and type the path of the NDIS2 driver. Enter the driver location, e.g. A:\NDIS2 e) Select "Change Network Configuarion". f) Select "Add Protocol" and "Microsoft NetBEUI" to add NETBEUI protocol in. g) Follow the instruction to complete the rest of the installation. 2. DOS ODI Driver Installation --------------------------- a) Run SETUP in DISK1 of Microsoft Client 3.0 for DOS. b) When asked where the software to install, enter the location, e.g. C:\MSCLIENT c) Select "ODI/NDIS Support Driver". d) Select "Change Network Configuarion". e) Select "Add Protocol" and "Microsoft NetBEUI" to add NETBEUI protocol in. f) Follow the instruction to complete the installation. g) Modify PROTOCOL.INI. Change all the lines BINDINGS=ODINSUPMAC to BINDINGS=CLPTX16 as shown by the arrows below. (there should have three lines needed to be modified). PROCOTOL.INI ------------ [network.setup] version=0x3110 netcard=odinsupmac,1,ODINSUPMAC,1 transport=ms$nwlink,MS$NWLINK transport=ms$ndishlp,MS$NDISHLP transport=ms$netbeui,MS$NETBEUI lana0=odinsupmac,1,ms$nwlink lana1=odinsupmac,1,ms$ndishlp lana2=odinsupmac,1,ms$netbeui [MS$NWLINK] FRAME=ETHERNET_802.3 DriverName=nwlink$ BINDINGS=CLPTX16 <----- [protman] DriverName=PROTMAN$ PRIORITY=MS$NDISHLP [ODINSUPMAC] <---- can be deleted [MS$NDISHLP] DriverName=ndishlp$ BINDINGS=CLPTX16 <----- [MS$NETBEUI] DriverName=netbeui$ SESSIONS=10 NCBS=12 BINDINGS=CLPTX16 <----- LANABASE=1 h) Copy from A:\DOSODI directory the following files to C:\NWCLIENT directory; LSL.COM, ODINSUP.EXE and CLPTX16.COM i) Create or copy the NET.CFG from A:\NDIS2 to C:\NWCLIENT Below is a sample of NET.CFG: NET.CFG ------- PROTOCOL ODINSUP Bind CLPTX16 BUFFERED Link driver CLPTX16 Frame Ethernet_802.2 Frame Ethernet_802.3 Frame Ethernet_II Frame Ethernet_SNAP j) Modify AUTOEXEC.BAT. Below is a sample. AUTOEXEC.BAT ------------ c:\NWclient\lsl c:\NWclient\CLPTX16 c:\MSClient\net initialize } These lines are added by C:\MSClient\nwlink } Microsoft DOS Client c:\MSClient\odinsup } during installation c:\MSClient\netbind } c:\MSClient\net start } ** Note:- Do not type in the character "}" and the message that follows them. They are added to explain a point only. k) Installation completed.Download Driver Pack
After your driver has been downloaded, follow these simple steps to install it.
Expand the archive file (if the download file is in zip or rar format).
If the expanded file has an .exe extension, double click it and follow the installation instructions.
Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.
Find the device and model you want to update in the device list.
Double-click on it to open the Properties dialog box.
From the Properties dialog box, select the Driver tab.
Click the Update Driver button, then follow the instructions.
Very important: You must reboot your system to ensure that any driver updates have taken effect.
For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.