README.TXT Driver File Contents (dfe650TXD_winxp_driver_1010.exe)

==================================================================
NOTES:
   D-Link DFE-650 Fast Ethernet PC Card Diagnostic Program
==================================================================
    (c) 1999 Copyright D-Link Corporation  ALL RIGHTS RESERVED

   The Diagnostic Program permits you to verify the configuration
   and suspect the isolation of faults; Make sure to isolate your
   network before running the Diagnostic Program.

   The additional information describe as below:

   1. Files List
   --------------
        A list of diagnostic program files:

        DIAG.EXE    : The diagnostic program
        DFCD.EXE    : Enabler for DFE-650 Fast Ethernet PC Card
        BASDIAG.EXE : The basic diagnostic program
        NETDIAG.EXE : The network diagnostic program
        DFE650.COM  : The ODI driver
        IPXODI.COM  : The IPX protocol driver for the ODI stack
        LSL.COM     : The link support layer for the ODI stack
        NET.CFG     : The ODI configuration file
        README.TXT  : This file

    2   Menu for Diagnostic Program
    --------------------------------
        The diagnostic main menu provides two options:

         i: Adapter Basic Diagnostics
            This option performs a diagnostic test on the adapter
            components.

        ii: Network Diagnostics
            This option allows you to test the connectivity of the adapter
            on the network.

        Diagnostic Program also lets you view the current adapter configuration,
        including:

        Viewed items: Your Current Configuration
                    <1> CS Vender
                    <2> CS Revision
                    <3> Node ID
                    <4> I/O Base Address
                    <5> Interrupt Number
                    <6> Connection Type

        The following displays the DIAG main menu:

                        ÉÍÍÍÍÍÍÍÍÍ Main Menu ÍÍÍÍÍÍÍÍ»
                        º  Adapter Basic Diagnostics º
                        º  Network Diagnostics       º
                        ÈÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍͼ


        The Adapter Basic Diagnostics option checks the major components
        on the adapter and network cable to ensure proper operation.
        The following is the screen print of the diagnostics screen.

         ÉÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ Adapter Diagnostic ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ»
         º  Node ID          : 00 80 C8 00 00 02                  º
         º  I/O Base Address : 300                                º
         º  Interrupt Number : 3                                  º
         º  Connection Type  : 10M Half                           º
         º                       Cycle   0                        º
         º  Current I/O Base Address ...................  PASS    º
         º  DC-DC Convert, Oscillator, Crystal T7213 ...  PASS    º
         º  EEPROM .....................................  PASS    º
         º  LAN Setup Registers ........................  FAIL    º
         º  Memory .....................................  Testing º
         º  Loopback Mode Testing ......................  Unknown º
         ÈÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍͼ

        Select Network Diagnostics to perform a live transmission test for
        checking the adapter's network connectivity. This test requires that
        LSL.COM, DFE650.COM and IPXODI.COM be located on the same directory
        as the Setup program.

                    ÉÍÍÍÍ Network Diagnostic ÍÍÍÍ»
                    º Set up as a master station º
                    º Set up as a slave station  º
                    ÈÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍͼ

          The Network Diagnostics option tests the ability of the adapter
          to communicate with other stations on the network. This test
          requires one master station and one slave station. The master
          station is responsible for sending test packets to the network.
          The slave station is responsible for sending back these packets
          to the master station. There is good connectivity if all the
          packets sent by the master were able to come back.

          Before running this test, ensure to copy first LSL.COM,
          IPXODI.COM, DFE650.COM and NET.CFG to the same directory where
          the dagnostic program resides. Also, ensure that the slave and
          master stations use the same frame type specified in the net.cfg
          file. We provide everything you need in the \DIAG directory.
          To set up a station as master, select "Set up as a master
          station". To set up the other station as slave, select "Set up
          as a slave station".

          When you start the test, these messages appear on each station:

                              MASTER STATION

                      ÉÍÍÍÍÍÍ Master Station ÍÍÍÍÍÍ»
                      º Waiting Sending Receiving  º
                      º    \       |        /      º
                      ÈÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍͼ

                               SLAVE STATION

    ÉÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ Slave Station ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ»
    º Node Address     : 00 80 C8 00 00 02                               º
    º I/O Base Address : 300                  Test started at : 20:06:10 º
    º Interrupt Number : 3                    Current time    : 20:10:50 º
    º Connect Type     : 10M Half                                        º
    º                                                                    º
    º Transmit Packet Length .................................  1234     º
    º Transmit Packet Counter ................................  1111     º
    º Transmit Time Out Counter ..............................  0        º
    º                                                                    º
    º Received Packet Length .................................  1234     º
    º Received Packet Counter ................................  1111     º
    º Received Error Counter .................................  0        º
    º No Response Counter ....................................  0        º
    º Data Mismatch Counter ..................................  0        º
    º                                                                    º
    ÈÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍͼ


Download Driver Pack

How To Update Drivers Manually

After your driver has been downloaded, follow these simple steps to install it.

  • Expand the archive file (if the download file is in zip or rar format).

  • If the expanded file has an .exe extension, double click it and follow the installation instructions.

  • Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.

  • Find the device and model you want to update in the device list.

  • Double-click on it to open the Properties dialog box.

  • From the Properties dialog box, select the Driver tab.

  • Click the Update Driver button, then follow the instructions.

Very important: You must reboot your system to ensure that any driver updates have taken effect.

For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.