Event.ini Driver File Contents (Conexant_HSF_V92_modem_Win_x86.ZIP)

# Event.ini
#
# This Event.ini is a template to be used as a starting point for 
# a customer-oriented, customized event.ini file
# Email questions to darren.santos@conexant.com 
#
# All the events must be numbered in sequence.
# If you want to disable an event, the Code must have the value -1 (see Event1 below).
#
#		System Events
#

########################################################################################
Section for temporary events
########################################################################################


[EVENT-1]
Name=Sales Training Diag Script
Display1=Session of 24/03/2000 16:55
Display10=Session of 24/03/2000 16:22
Display19=Session of 24/03/2000 15:33
Display28=Session of 24/03/2000 15:28
Display2=Transmit Carrier Negotiation Result=V34
Display11=Transmit Carrier Negotiation Result=V34
Display20=Transmit Carrier Negotiation Result=V34
Display29=Transmit Carrier Negotiation Result=V34
Display3=Receive Carrier Negotiation Result=V34
Display12=Receive Carrier Negotiation Result=V34
Display21=Receive Carrier Negotiation Result=V34
Display30=Receive Carrier Negotiation Result=V34
Display4=Round Trip Delay=0 (22064)
Display13=Round Trip Delay=0 (22519)
Display22=Round Trip Delay=0 (21738)
Display31=Round Trip Delay=0 (22140)
Display5=Maximum Upstream Bits per Second=
Display14=Maximum Upstream Bits per Second=
Display23=Maximum Upstream Bits per Second=10810 bps (0)
Display32=Maximum Upstream Bits per Second=530 bps (0)
Display6=Maximum Downstream Bits per Second=
Display15=Maximum Downstream Bits per Second=
Display24=Maximum Downstream Bits per Second=47360 bps (0)
Display33=Maximum Downstream Bits per Second=0 bps (0)
Display7=Robbed Bits Detected=0 (22064)
Display16=Robbed Bits Detected=0 (22519)
Display25=Robbed Bits Detected=0 (21738)
Display34=Robbed Bits Detected=0 (22140)
Display8=Signal to Noise Ratio=33 (22064)
Display17=Signal to Noise Ratio=33 (22519)
Display26=Signal to Noise Ratio=33 (21738)
Display35=Signal to Noise Ratio=33 (22140)
Display9=Reason for V.34 Fallback=Dual PCM
Display18=Reason for V.34 Fallback=Dual PCM
Display27=Reason for V.34 Fallback=Dual PCM
Display36=Reason for V.34 Fallback=Dual PCM

########################################################################################
#These events are tied to the Test Dialtone and Test Modem buttons-
########################################################################################

[EVENT-2] # DO NOT EDIT OR DELETE THIS EVENT
NAME=Hardware test failed
Display1=Hardware test failed
Display2="  "
Display3=Please check to make sure the modem is inserted in the computer correctly.
Display4="  "
Display5=If the hardware test still fails, please contact technical support.

[EVENT-3] # DO NOT EDIT OR DELETE THIS EVENT
NAME=No Dialtone
Display1=The modem has reported there is no dialtone on the line.
Display2="  "
Display3=Check to see if the line is in use by someone else.
Display4=Pick up a phone on the same line to see if there is a dialtone.



########################################################################################
#Disabled User Events- SmartDAA Related Events
#To enable an event, copy the event, and append it to the enabled user event section. 
#Then reassign the event number to equal (last event #) +1
########################################################################################


[EVENT-4] # Smart DAA only
Name=The Line is in use
Level=Alert
Code=43		# CSDIAG_CALL_SETUP_RES
Subcode=3
Display1=The modem has reported the line is in use.
Display2="  "
Display3=Check to see if the line is in use by someone else.

[EVENT-5] # Smart DAA only
Name=Extension Offhook
Level=Alert
Code=45		# CSDIAG_TERMINATION_CAUSE
Subcode=43      # Extension Offhook
Display1=The modem is reporting a phone extension is offhook.
Display2=" "
Display3=Check the other phones in the house and make sure that all are on hook.
Display4=If you still have a problem unplug the phone line from the modem and check for dial tone.

[EVENT-6] # Smart DAA only
Name=Loop Current Interrupted, Code 45-46
Level=Alert
Code=45		# CSDIAG_TERMINATION_CAUSE
Subcode=46      # Loop Current Interrupted
Display1=Loop Current Interrupted

[EVENT-7] #Smart DAA only
Name=Digital Line Protection
Level=Alert
Code=45
Subcode=101
Display1=A digital line was detected by the modem. 
Display2=To protect the modem from high voltages, the modem 
Display3=was place back on hook. Please disconnect the digital phone
Display4=line and plug the modem into an analog phoneline.

########################################################################################
#Disabled User Events- Untested, 
########################################################################################


[EVENT-8]  # This event was not tested.  Code 43 Subcode 0 is not documented.
Name=Call Didn't Connect, Code 43-0
Level=Alert
Code=43		# CSDIAG_CALL_SETUP_RES
Subcode=0
Display1=Check the following solutions and then re-dial:
Display2="  "
Display3=1) Make sure an extension phone is not being used.
Display4=2) Make sure the phone cable is connected.
Display5=3) Try using a different phone cable.
Display6=4) Try dialing another number.

[EVENT-9] # This alert was not able to be tested. Could not get this subcode from API.
Name=Voice Code 43-5
Level=Alert
Code=43		# CSDIAG_CALL_SETUP_RES
Subcode=5
Display1=The line has Voice trafic in it.

[EVENT-10] # Not used in normal modem opperation.
Name=Data Calling Tone Code 43-8
Level=Alert
Code=43		# CSDIAG_CALL_SETUP_RES
Subcode=8
Display1=Date Calling Tone

[EVENT-11] # This alert only works when making fax calls, not used.
Name=Fax Answer Tone Code 43-9
Level=Alert
Code=43		# CSDIAG_CALL_SETUP_RES
Subcode=9
Display1=Fax Answer Tone

[EVENT-12] # Only works on incoming fax calls, not used.
Name=Fax Calling Tone Code 43-10
Level=Alert
Code=43		# CSDIAG_CALL_SETUP_RES
Subcode=10
Display1=Fax Calling Tone

[EVENT-13] # Need documentation on this code.
Name=No Previous Call Code 45-1
Level=Alert
Code=45
Subcode=1
Display1=No Previous Call

[EVENT-14] # Blacklisting is not used in the US.
Name=Number Blacklisted
Level=Alert
Code=45		# CSDIAG_TERMINATION_CAUSE
Subcode=41      # Blacklisted
Display1=In some regions this can occur if the modem dials the
Display2=same number too many times within a certain period.
Display3="  "
Display4=Wait a bit, then try to dial the number.

[EVENT-15] # Not documented, tested on used. Blacklisted?
Name=Delayed, Code 45-4
Level=Alert
Code=45
Subcode=4
Display1=Delayed

[EVENT-16] # Tested but removed, dial tone tested with -3 Code.
Name=No Dial Tone on Phone Line
Level=Alert
Code=45		# CSDIAG_TERMINATION_CAUSE
Subcode=47      # No Dial Tone
Display1=The phone line does not have a dial tone.
Display2="  "
Display3=Make sure the line is plugged into the modem.
Display4=Make sure the phone line is not in use.
Display5=Plug a phone in and check for dial tone.
Display6=If you still have no dial tone call the phone company.

[EVENT-17] # Not documented, tested or used.
Name=The line has voice on it, Code 45-48
Level=Alert
Code=45		# CSDIAG_TERMINATION_CAUSE
Subcode=48      # Voice
Display1=The phone line does not have a dial tone.
Display2="  "
Display3=Make sure the line is plugged into the modem.
Display4=Make sure the phone line is not in use.
Display5=Plug a phone in and check for dial tone.
Display6=If you still have no dial tone call the phone company.

[EVENT-18] # Not documented, tested or used.
Name=Fax Detected
Level=Alert
Code=45		# CSDIAG_TERMINATION_CAUSE
Subcode=66      # Fax Detected
Display1=The number you have called is a Fax number.
Display2="  "
Display3=Check the number and try again.

[EVENT-19] # Not tested, documented or used.
Name=Protocol Negotiation Failed, Code 45-94
Level=Alert
Code=45		# CSDIAG_TERMINATION_CAUSE
Subcode=94      # Negotiation Failed
Display1=This may have been just a random disconnection.  If the problem persists, then check the solutions below:
Display2="  "
Display3=1) Make sure an extension phone is not in use.
Display4=2) If your phone line has call waiting then disable it per the phone company instructions.
Display5=3) There may be a problem at the number being dialed.  Try another number.

[EVENT-20] # Not documented, tested on used.
Name=Call in Progress Code 45-2
Level=Alert
Code=45
Subcode=2
Display1=Call in Progress

########################################################################################
########################################################################################
#		Enabled Events
########################################################################################
########################################################################################

[EVENT1] #Code 43-1 This alert comes up if the phone line is unplugged during a call.
Name=No Dialtone
Level=Alert
Code=43		# CSDIAG_CALL_SETUP_RES
Subcode=1
Display1=Check the following solutions and then re-dial:
Display2="  "
Display3=1) Make sure an extension phone is not being used.
Display4=2) Make sure the phone cable is connected.
Display5=3) Try using a different phone cable.

[EVENT2] # Code 45-0 Not tested
Name=Call Terminated
Level=Suspend
Code=45		# CSDIAG Termination Cause
Subcode=0	# Cause Undifined
Display1=Check the following solutions and then re-dial:
Display2="  "
Display3=1) Make sure an extension phone is not being used.
Display4=2) Make sure the phone cable is connected.
Display5=3) Try using a different phone cable.
Display6=4) Try dialing another number.

[EVENT3] # Not able to get this to display. Call waiting gives 45-63 when simulated.
Name=Call Waiting Disconnect Code 45-3
Level=Alert
Code=45		# CSDIAG_TERMINATION_CAUSE
Subcode=3       # Call Waiting Tone
Display1=Your modem was disconnected because of Call Waiting
Display2="  "
Display3=An incoming call caused a disconnect due to the call-waiting feature on 
Display4=this phone line.
Display5=To avoid this you can modify Windows dialing properites to disable call waiting.
Display6=" "
Display7=1. Click on the Start button and select Settings and Control Panel.
Display8=2. Double-click on the Modem icon.
Display9=3. Now click on the Dialing Properties button.
Display10=4. Put a check in the 'To disable call waiting, dial:' box and select
Display11=the correct command in the drop down box to the right.
Display12=The most common is *70.
Display13=Contact your local phone company if you are not sure.

[EVENT4] # Tested. S30 timer for line activity, in 10 sec steps. Set with ats30=x.
Name=Inactivity Timer Expired
Level=Alert
Code=45		# CSDIAG_TERMINATION_CAUSE
Subcode=25      # Inactivity Timer Expired
Display1=Your modem was disconnected because of inactivity on the connection.
Display2="  "
Display3=If the connection is not used for some period of time
Displat4=your computer will interrupt the connection.
Display5=This amount of time is defined by the software on your computer
Display6=and may be set by the ISP software you are using.

[EVENT5] # Tested with different S7 values.  Came up with voice answer.
Name=No Answer
Level=Alert
Code=45		# CSDIAG_TERMINATION_CAUSE
Subcode=44      # S7 Timer Expired
Display1=The number dialed is not being answering by a modem.
Display2="  "
Display3=Check the number to see if it is correct.
Display4=Try a different number for the internet service provider.
Display5=Using a telephone, call the number you are dialing to see if it is being answered.

[EVENT6] # Tested with simulation
Name=Fast Busy Tone
Level=Alert
Code=45		# CSDIAG_TERMINATION_CAUSE
Subcode=49      # Reorder Tone
Display1=This usually indicates that all circuits are busy.
Display2=" "
Display3=Check the number and dial again. If this problem continues check with
Display4=the phone company or your internet service provider.

[EVENT7]
Name=Unexpected Modem Disconnect
Level=Alert
Code=45		# CSDIAG_TERMINATION_CAUSE
Subcode=60      # Carrier Lost
Display1=Disconnect due to lost carrier
Display2="  "
Display3=Your phone line got unplugged or something caused it to disconnect.
Display4=Check your phone cable, check dial tone and try again.
Display5=If this continues you may have a problem with the phone line.

[EVENT8]
Name=Training Failed
Level=Alert
Code=45       # CSDIAG_TERMINATION_CAUSE
Subcode=61      # Training Failed
Display1=The Modem training sequence failed.
Display2=This is caused by poor line conditions.
Display3=If the problem continues contact the phone company about line quality.

[EVENT9]
Name=Unexpected Modem Disconnect
Level=Alert
Code=45		# CSDIAG_TERMINATION_CAUSE
Subcode=63      # Retrain Failed
Display1=Your modem failed to retrain after the line conditions changed.
Display2=This may have been a random disconnection or caused by Call Waiting.
Display3=If the problem persists, then check the solutions below:
Display4="  "
Display5=1) Make sure an extension phone is not in use.
Display6=2) If your phone line has call waiting disable it per the phone company instructions.

[EVENT10]
Name=Unexpected Modem Disconnect
Level=Alert
Code=45		# CSDIAG_TERMINATION_CAUSE
Subcode=65      # GSTN Cleardown
Display1=This call was terminated by the modem you called.
Display2=This could be normal but could also be an error by the other modem.

[EVENT11] # Tested
Name=Connection Terminated
Level=Alert
Code=45		# CSDIAG_TERMINATION_CAUSE
Subcode=80      # Anykey Abort
Display1=The call never connected
Display2=" "
Display3=You may have hit a key during the modem handshake.
Display4=This will terminate the connection.  Try again and wait longer before typing.

[EVENT12]
Name=Modem Disconnection From ATH
Level=Alert
Code=45		# CSDIAG_TERMINATION_CAUSE
Subcode=81      # ATH Hang up command issued
Display1=Disconnect Caused from ATH issued by your computer.
Display2=" "
Display3=A command was issued by your computer to reset the modem.
Display4=This could have been caused by one of the programs or by Windows.

[EVENT13]
Name=Modem Disconnection From ATZ
Level=Alert
Code=45		# CSDIAG_TERMINATION_CAUSE
Subcode=82      # ATZ Reset command issued
Display1=Disconnect Caused from ATZ issued by your computer.
Display2=" "
Display3=A command was issued by your computer to reset the modem.
Display4=This could have been caused by one of the programs or by Windows.

[EVENT14] # Not tested
Name=Frame Reject Error
Level=Alert
Code=45		# CSDIAG_TERMINATION_CAUSE
Subcode=90      # Frame Reject
Display1=Problem with V.42 LAPB error control.
Display2=An error in the frame caused disconnect.
Display3=This could be caused by the line conditions changing.

[EVENT15] # Tested with at\n0 (EC off) and at\n4 on calling modem
Name=Error Control Problem
Level=Alert
Code=45		# CSDIAG_TERMINATION_CAUSE
Subcode=91      # No EC Established
Display1=The connection was terminated because of an error control problem.
Display2=If error control is disabled on the answering modem, your modem may
Display3=hang up after a short time. Check with your internet service provider.

[EVENT16] # Not tested
Name=Protocol Violation
Level=Alert
Code=45		# CSDIAG_TERMINATION_CAUSE
Subcode=92      # Protocol Violation
Display1=The answering modem has a problem.
Display2=Check with the internet service provider or service you are calling 
Display3=if the problem continues.

[EVENT17] # Not tested
Name=Unexpected Modem Disconnect
Level=Alert
Code=45		# CSDIAG_TERMINATION_CAUSE
Subcode=93      # n400 Exceeded
Display1=This may have been just a random disconnection.  If the problem persists, check the solutions below:
Display2="  "
Display3=1) Make sure an extension phone is not in use.
Display4=2) If your phone line has call waiting then disable it per the phone company
Display5=instructions.  Check with Technical support if the problem continues.

[EVENT18] # Tested, ATH by recieving modem with Error Control on.
Name=Dropped by the other modem
Level=Alert
Code=45		# CSDIAG_TERMINATION_CAUSE
Subcode=95      # Discontinue Frame
Display1=The number being dialed disconnected the call.
Display2="  "
Display3=Make certain the number being dialed is correct.
Display4=Try a different number for the internet service provider.
Display5=Check with the ISP to see if they have a problem.

[EVENT19]
Name=Busy Tone Detected
Level=Alert
Code=43 #CSDIAG_CALL_SETUP_RES
Subcode=3 #UD_CallSetupInfo_Busy
Display1="A busy tone was detected"
Display2="Please try placing the call again or make sure the correct number is being dialed."


[EVENT20] #Smart DAA only
Name=Digital Line Protection
Level=Alert
Code=45
Subcode=101
Display1=A digital line was detected by the modem. 
Display2=To protect the modem from high voltages, the modem 
Display3=was place back on hook. Please disconnect the digital phone
Display4=line and plug the modem into an analog phoneline.

###############################################################"
[EVENT21] #Smart DAA only
Name=Digital Line Protection
Level=Alert
Code=41
Subcode=0
ModemOnHold=1

[EVENT21] #Smart DAA only
Name=Digital Line Protection
Level=Alert
Code=103
Subcode=0
ModemOnHold=1

[EVENT22] #Smart DAA only
Name=Digital Line Protection
Level=Alert
Code=105
Subcode=0
ModemOnHold=1
###############################################################"

[EVENT23]
Name=TX rate alert
Level=Suspend
Display1=Your upstream data rate has fallen below 28.8k
Display2="  "

[EVENT24]
Name=RX data rate alert
Level=Suspend
Display1=The downstream data rate has fallen below 40k
Display2="  "

[EVENT25]
Name=SNR Alert
Level=Suspend
Display1=Signal to noise ratio is less than 40db
Display2="  "

[EVENT26]
Name=Robbed Bits Alert
Level=Alert
Display1=2 or more robbed bits have been detected
Display2="  "

[EVENT27]
Name=Digital Pads Alert
Level=Alert
Display1=1 or more digital pads have been detected
Display2="  "

[EVENT28]
Name=Rate Renegotiations granted
Level=Alert
Display1=3 or more rate renegotiations granted
Display2="  "

[EVENT29]
Name=Retrains granted
Level=Alert
Display1=3 or more retrains granted
Display2="  "
Download Driver Pack

How To Update Drivers Manually

After your driver has been downloaded, follow these simple steps to install it.

  • Expand the archive file (if the download file is in zip or rar format).

  • If the expanded file has an .exe extension, double click it and follow the installation instructions.

  • Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.

  • Find the device and model you want to update in the device list.

  • Double-click on it to open the Properties dialog box.

  • From the Properties dialog box, select the Driver tab.

  • Click the Update Driver button, then follow the instructions.

Very important: You must reboot your system to ensure that any driver updates have taken effect.

For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.

server: web3, load: 1.97