yukonwnt.txt Driver File Contents (lan.zip)

(C)Copyright 2002-2003 Marvell(R).
All rights reserved
===========================================================================

yukonwnt.txt created 23-Dec-2003

Readme File for YUKONWNT.sys v6.32
Marvell Yukon Gigabit Ethernet Adapter

NDIS4 Miniport Driver for Windows NT4 (x86)

This file contains
 1  Overview
 2  Required Files
 3  Installation
    3.1  Installing the driver
    3.2  Updating the driver
 4  Parameters
 5  Troubleshooting

===========================================================================


1  Overview
===========

YUKONWNT.sys is the NDIS4 32-bit Miniport driver for the
Marvell Yukon Gigabit Ethernet Adapter.

This driver supports only Windows NT4 (x86).
This README file explains how to install the Miniport driver on a machine
running Windows NT4 (x86).

This YUKONWNT NDIS4 Miniport driver cannot be used with other 
Windows versions than Windows NT4 (x86).
***


2  Required Files
=================

To install the driver, the following files are required:
YUKONWNT.sys Marvell Yukon Gigabit Ethernet Adapter NDIS4 Miniport driver 
oemsetup.inf    installation setup script
GEDIALOG.HLP    installation help file
GEDIALOG.DLL    installation dialogs
***


3  Installation
===============

3.1  Installing the driver
--------------------------

Read the installation instructions in the adapter manual carefully.
Follow these instructions to install the adapter in your computer.

1.  Start Windows NT4 (x86).
2.  Click START / SETTINGS / CONTROL PANEL / NETWORK.
3.  Select ADAPTERS.
4.  Click ADD.
5.  Select HAVE DISK.
6.  Depending on the type of installation medium used (e.g. CD-ROM, floppy
    diskette, network drive, etc.) enter the path to the required files. 
7.  Click OK.
8. Select the Marvell Yukon Gigabit Ethernet Adapter entry that matches your 
adapter. 
9.  Click OK.
10. Select the appropriate configuration (see section "Driver Options"
    in this readme file for details).

NOTE: We strongly recommend to install the latest Windows NT4 (x86) Service 
Pack *after* successful installation of the driver. 

11. Click OK.
12. Restart your system.


***


3.2  Updating the driver
------------------------

You can use the CONTROL PANEL / NETWORK / ADAPTERS / 
Marvell Yukon Gigabit Ethernet Adapter / UPDATE button to update an already 
installed 
driver for your Marvell Yukon Gigabit Ethernet Adapter.

NOTE: If you are updating from a driver version which is lower than V6.00, 
you    cannot use the UPDATE button to update the driver. You must first    
remove the installed driver via the CONTROL PANEL / NETWORK /    ADAPTERS / 
Marvell Yukon Gigabit Ethernet Adapter / REMOVE button. 
Then reboot the computer and install the new driver as described 
in the section "Installing the driver".



Please note that the latest version of the YUKONWNT driver is
available for download from our web site.


4  Parameters
=============

The YUKONWNT.sys driver supports various advanced options.

 CAUTION: Setting any advanced driver options can dramatically change 
          the behaviour of the driver. This can lead to serious system 
          or network problems. So care must be taken when any driver 
          options are set by the user.

          If the driver is ever misconfigured in such a way that it no 
          longer operates properly, then remove and re-install the driver.
          This causes the default values for all options to be restored.

To set the advanced driver options, proceed as follows:
1.  Start the Registry Editor tool REGEDIT.
2.  All of the driver's options are stored in the system's registry
    database. Open the path to the driver's options:

	\HKEY_LOCAL_MACHINE
	 \SYSTEM
	  \CurrentControlSet
	   \Services
	    \YUKONWNTx
	     \Parameters

    Where the 'x' in YUKONWNT must be replaced by the instance
    number of the driver, i.e. YUKONWNT1, YUKONWNT2, etc.
3.  The following actions can be executed:

    - Modify an existing driver option by double-clicking it.
    
    - Create a new driver option: Select EDIT > NEW, select the type for 
      the new option: "String", "Binary" or "DWORD". The type required 
      by each particular driver option is listed in the "Type:" field in
      the description below.
    
    - Delete an existing driver option: Select the option to be deleted,
      click EDIT > DELETE. In this case, the driver will use its built-in 
      default for the deleted option.

5.  After you have finished changing the driver options, reboot the 
    machine.

NOTE: The machine must be rebooted before any changed options can take 
      effect.

The following is a list of advanced options supported by the YUKONWNT
driver.

NOTE: If an advanced option is not present in the registry, you may create
      it via EDIT / NEW. Note that in the absence of any option, the 
      driver will use its built-in default value for that option, as 
      described by "Default value:" below.

The YUKONWNT.sys driver allows you to modify several options in order to 
optimize the operation of your Marvell Yukon Gigabit Ethernet Adapter. 



The parameters supported by the driver are described below.

Bus Type
----------

Registry Name:	"BusNumber"
Default value:    next available adapter found when driver installed
Valid range:      depends on system configuration

This parameter specifies the adapter instance to which the driver shall be 
bound. You can choose from a list of bus/slot combinations for which the 
system has found one or more instances of the Marvell Yukon Gigabit Ethernet 
Adapter. 
When you add, remove,or move any adapters to, from, or between PCI slots,
this list will change.


Network Address
---------------

Registry Name:	"NetworkAddress"
Default value:  burned-in adapter address
Valid range:    0y-00-00-00-00-01 to FE-FF-FF-FF-FF-FF (hexadecimal), 
                where at least the "multicast" bit must not be set 
                (it indicates that the address field contains an 
                individual address)and the "locally administered" bit 
                is set (the address has been assigned by a local
                administrator). These two bits are first and second 
                bits transmitted on the LAN medium.

CAUTION: Each individual network MAC address can only be used once in a
         network. Assigning the same address to more than one adapter in 
         the same network is not allowed and can cause serious network 
         problems.

To use a network MAC address other than the one burned into the adapter,
enter the network address in the following hexadecimal format:

    XX-XX-XX-XX-XX-XX (e.g. 02-00-5A-98-12-34).

If the network address field blank is left blank (or a different number of
digits is specified), the network address burned into the adapter will 
be used.


Maximum Frame Size
------------------

Registry Name:	"MaxFrameSize"
Default value:  1514 (decimal)
Valid range:    12..9014 (decimal)

This parameter specifies the maximum frame size in bytes that the driver
will support. The performance of your network usually increases when
a large packet size is used. Do not use values larger than 1514 if you
are not sure if your network supports jumbo frames.






Link Speed
----------

Registry Name:	"Speed_<n>"	<n> = port designator (A or B) 
Default value:  1 (Auto)
Valid values:   1 = "Auto"
                2 = "10"
                3 = "100"
                4 = "1000"

- "Auto"        Auto-negotiate Speed
- "10"          Force Speed to 10 MBit
- "100"         Force Speed to 100 MBit
- "1000"        Force Speed to 1000 MBit

This parameter is only available for V2.0 copper versions of the Marvell 
Yukon Gigabit Ethernet Adapter. 

Number of Receive Buffers
-------------------------

Registry Name:	"MaxReceives"
Default value:  50 (decimal)
Valid range:    3..500 (decimal)

This parameters defines the number of receive buffers allocated by the
driver. If the system does not have enough resources the driver will fail 
to load. Increasing this value may improve performance.


Number of Transmit Buffers
--------------------------

Registry Name:	"MaxTransmits"
Default value:  50 (decimal)
Valid range:    4..200 (decimal)

This parameters defines the number of transmit buffers allocated by the
driver. If the system does not have enough resources the driver will 
fail to load. Increasing this value may improve performance.

Interrupt Moderation
--------------------

Registry Name:	"Moderate"
Default value:  1 (On)
Valid values:   1 = "On"
                0 = "Off"

If more than the specified rate of interrupts occur, the function 
Interrupt Moderation groups these interrupts so that several data packets 
can be handled per interrupt. This will lead to lower CPU utilization 
but may increase the latency.


Max IRQ per Sec
---------------

Registry Name:	"FixedIntMod"
Default value:  5000 (decimal)
Valid range:    1000..30000 (decimal)

This parameter specifies the interrupt rate for Interrupt Moderation. If
Interrupt Moderation is set to "Off" it will be ignored.

Log Status Messages
-------------------

Registry Name:	"MessageLog"
Default value:  1 (Status Messages)
Valid values:   0 = "All Messages"
                1 = "Status Messages"
                2 = "Warnings"
                3 = "Errors"
                4 = "None"

This parameter specifies the messages, which are to be logged in the 
Event Log.

- "All Messages":    This option should only be used for test purposes.
- "Status Messages": In this mode the driver will generate an event log 
                     entry every time the link status changes.
- "Warnings":        In this mode you will only receive warning or error 
                     messages.
- "Errors":          In this mode you will only receive error messages.
- "None":            All driver messages will be suppressed. It is not 
                     recommended to use this value.


AutoNegotiation
---------------

Registry Name:	"AutoNegotiation_<n>"  <n> = port designator (A or B)
Default value:  1 (On)
Valid range:    0 = "Off"
                1 = "On"
                2 = "Auto-Sense"

NOTE: If this parameter is set to "Off" and 'DuplexCapabilities' is
      set to "half and full duplex" the driver will override the
      setting and use "On" instead.

NOTE: Copper adapters do not support "auto-sense". This setting will be
      treated like "On".

This parameter defines the auto-negotiation mode and can be set for each 
port individually, which is helpful if the port at the other end of the 
cable is limited in its capabilities. Using the default setting, the
Marvell Yukon Gigabit Ethernet Adapter should
automatically detect the capabilities of the peer port.


DuplexCapabilities
------------------

Registry Name:	"DuplexCapabilities_<n>"  <n> = port designator (A or B)
Default value:  3 (half and full duplex)
Valid range:    1 = "half duplex"
                2 = "full duplex"
                3 = "half and full duplex"

NOTE: This parameter is ignored if 'AutoNegotiation' is set to "auto-sense".

This parameter can be used to limit the duplex capabilities the port
reports during auto-negotiation. This parameter can be set for each port
individually, which is helpful if the port at the other end of the cable 
cannot handle all possible combinations. Using the default setting, the
Marvell Yukon Gigabit Ethernet Adapter should
automatically detect the capabilities of the peer port.

FlowControl
-----------

Registry Name:	"FlowControl_<n>"  <n> = port designator (A or B)
Default value:  3 (Asymmetrical and Symmetrical Flow Control)
Valid range:    0 = "No Flow Control"
                1 = "Asymmetrical Flow Control"
                2 = "Symmetrical Flow Control"
                3 = "Asymmetrical and Symmetrical Flow Control"

Modes:
- Symmetrical Flow Control: Both link partners are allowed to send 
                            PAUSE frames.

- Asymmetrical and Symmetrical Flow Control: Both or only the remote
                                             link partner are allowed
                                             to send PAUSE frames.

- Asymmetrical Flow Control: Only the local link partner is allowed 
                             to send PAUSE frames.

- No Flow Control: No link partner is allowed to send PAUSE frames.

NOTE: This parameter is ignored if 'AutoNegotiation' is set to "Off".

This parameter can be used to set the flow control capabilities the port 
reports during auto-negotiation. This parameter can be set for each port 
individually, which is helpful if the port at the other end of the cable 
cannot handle all possible combinations. Using the default setting, the
Marvell Yukon Gigabit Ethernet Adapter should
automatically detect the capabilities of the peer port.


Role
----
Registry Name:	"Role_<n>"  <n> = port designator (A or B)
Default value:  0 (Auto)
Valid range:    0 = "Auto"
                2 = "Master"
                3 = "Slave"

NOTE: This parameter will be used only for copper adapters.

For two 1000Base-T ports to communicate, one must take the role of the 
master (providing timing information), while the other must be slave.
Usually, this is negotiated between the two ports during link
establishment. If this fails, a port can be forced to a specific setting 
with this parameter.

Preferred Port
--------------

Registry Name:	"PreferredPort"
Default value:  1 (A)
Valid range:    1 = "A"
		2 = "B"

NOTE: This parameter is only available for dual link adapters.

Use this parameter to set the preferred port the RLMT (Redundant
Link Management Technology) will use for all network traffic, if more than
one port has an active link to the network.


RLMT Mode
---------

Registry Name:	"RlmtMode"
Default value:  1 (CLS)
Valid range:    1 = "CLS"
                3 = "CLP"
                7 = "CLPSS"

NOTE: This parameter is only available for dual link adapters.

Use this parameter to set the operational mode for the RLMT:

- "CLS" (Check Link State): RLMT uses the link state reported by the
      adapter hardware for each individual port to determine whether a 
      port can be used for all network traffic or not.

- "CLP" (Check Local Port): In this mode, RLMT monitors the network path
      between the two ports of an adapter by regularly exchanging packets 
      between them. This mode requires a network configuration in which 
      the two ports "see" each other (i.e. there must not be any router 
      between the ports).

- "CLPSS" (Check Local Ports and Segmentation Status): This mode supports 
      the same functions as the CLP mode and additionally checks network 
      segmentation by sending BPDU hello packets. Thus, this mode is only 
      to be used if Gigabit Ethernet switches are installed on the network
      that have been configured to use the Spanning Tree protocol.

NOTE: RLMT modes "CLP" and "CLPSS" are designed to operate in 
      configurations where a network path between the ports on one adapter
      exists. Moreover, they are not designed to work where adapters are
      connected back-to-back.



5  Troubleshooting
==================

If you should encounter any problems with your Marvell Yukon Gigabit 
Ethernet Adapter, please re-read the instructions above and the 
documentation supplied with the operating system. 
Also refer to your system event log file (using the Event Viewer) and
check it for entries from YUKONWNT.

If your particular problem is not listed or the error persists, please send 
your system event log file or at least the event id number and the logging 
data (as WORDs) of the entries made by YUKONWNT to our technical support. 

*** End of Readme File ***

Download Driver Pack

How To Update Drivers Manually

After your driver has been downloaded, follow these simple steps to install it.

  • Expand the archive file (if the download file is in zip or rar format).

  • If the expanded file has an .exe extension, double click it and follow the installation instructions.

  • Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.

  • Find the device and model you want to update in the device list.

  • Double-click on it to open the Properties dialog box.

  • From the Properties dialog box, select the Driver tab.

  • Click the Update Driver button, then follow the instructions.

Very important: You must reboot your system to ensure that any driver updates have taken effect.

For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.

server: web2, load: 0.97