README Driver File Contents (2000pnp.exe)

****************************************************************************
*                                                                          *
*                         ATI AT-2000PNP Ethernet Adapter                  *
*                                                                          *
*                              NDIS Driver                                 *
*                                                                          *
*                              Ver. 2.30                                   *
*                                                                          *
*                              README file                                 *
*                                                                          *
****************************************************************************

1. Introduction:

   These Ethernet NDIS drivers conform to 3Com/Microsoft Network Driver In-
   terface Specification v2.0.1 (Final 1990-10-8). It supports many network
   applications, such as Microsoft LAN Manager for DOS, SUN PC-NFS, Banyan
   VINES for DOS workstations, Sitka 10NET and Wollongong Pathway Access.


2. Contents of the Subdirectory:

      PNPND.DOS       The NDIS driver for DOS.

      PNPND.OS2       The NDIS driver for OS/2.

      PROTOCOL.INI    The prototype of the final PROTOCOL.INI which stores
                      the configuration and binding information for all
                      protocols and MAC modules in the system.  This is for
                      use of the Protocol Manager during initialization.

                      This file will be bound or modified during the instal-
                      lation.


3. Installation

   First, install your AT-2000PNP Ethernet Adapter on your PC system follow-
   ing the procedure described in your installation manual. Then skip to the
   related section for your specific network application to continue the
   NDIS driver installation.


3.1 SUN PC-NFS Installation

   * Installation on a DOS Workstation

     1) If PC-NFS has not been installed yet, follow the instructions in
        the PC-NFS installation manual to install PC-NFS.

        Or, change the current directory to C:\NFS and run NFSCONF. Then
        choose "Configure an Ethernet network connection" when it appears
        during installation.

     2) Choose "NDIS" when you are asked to select the network driver used
        for PC-NFS.

     3) When the installation is completed, choose "Exit" to return to
        DOS.

     4) Copy PNPND.DOS to the \LANMAN directory of your hard disk.

     5) Edit CONFIG.SYS to add the following line:

             DEVICE=C:\LANMAN\PNPND.DOS

        between

             DEVICE=C:\LANMAN\PROTMAN.SYS
             DEVICE=C:\LANMAN\NFS-NDIS.SYS.

     6) Edit C:\LANMAN\PROTOCOL.NFS as follows.

       - If the Operating Mode in DIAG has been set as Plug & Play
         mode, you should:

         a) Replace "your-mac-module" with "PNPND_NIF"in the file. There
            are two "your-mac-module" to be changed.

         b) Replace "YOURMAC$" with "PNPND$".

         c) Replace the line "option 1 = value 1 etc" with the desired
            option or delete it.

         The following is an example of the modified PROTOCOL.NFS:

                   [protocol manager]
                         drivername=PROTMAN$
                   [PNPND_NIF]
                         drivername=PNPND$
                   [NFS-NDIS]
                         drivername=NFSLINK$
                         bindings=PNPND_NIF

       - If the Operating Mode in DIAG has been set as Jumperless mode,
         you should:

         a) Replace "your-mac-module" with "PNPND_NIF"in the file.  Note
            that there are two "your-mac-module" to be changed.

         b) Replace "YOURMAC$" with "PNPND$".

         c) Replace the line "option 1 = value 1 etc" with the desired
            option or delete it.

                   [protocol manager]
                         drivername=PROTMAN$
                   [PNPND_NIF]
                         drivername=PNPND$
                         IOBASE=0x300
                         INTERRUPT=3
                   [NFS-NDIS]
                         drivername=NFSLINK$
                         bindings=PNPND_NIF

         Note: You should change the INTERRUPT and IOBASE according
               to the hardware settings.

     7) Rename "PROTOCOL.NFS" to "PROTOCOL.INI".

     8) Edit AUTOEXEC.BAT to add the line "C:\LANMAN\NETBIND" before
        "PRT *".

     9) Reboot the PC system.


3.2 Banyan VINES Installation

   * Installation on the First DOS Workstation

     1) Create a DOS boot diskette with DOS 3.1 or later.

     2) Copy all files from \NDIS2 of Master Disk to the boot diskette.

     3) Copy PNPND.DOS and PROTOCOL.INI to the boot diskette.

     4) Edit PROTOCOL.INI as follows:

        - If the Operating Mode in DIAG has been set as Plug & Play
          mode, you should use any text editor to edit the following lines
          in your PROTOCOL.INI:

                   [protocol manager]
                         drivername=PROTMAN$
                   [VINES_XIF]
                         drivername=NETBEUI$
                         bindings=PNPND_NIF
                   [PNPND_NIF]
                         drivername=PNPND$

        - If the Operating Mode in DIAG has been set as Jumperless mode,
          you should use any text editor to edit the following lines in
          your PROTOCOL.INI:

                   [protocol manager]
                         drivername=PROTMAN$
                   [PNPND_NIF]
                         drivername=PNPND$
                         IOBASE=0x300
                         INTERRUPT=3
                   [NFS-NDIS]
                         drivername=NFSLINK$
                         bindings=PNPND_NIF

          Note: You should change the INTERRUPT and IOBASE according
                to the hardware settings.

     5) At the DOS prompt, type "PCCONFIG";  the configuration window is
        displayed.  Choose "Network Card Settings", then choose "NDIS
        Ethernet", and enter the following parameters:

             Interrupt Level: [interrupt_number]
             PROTOCOL.INI bindings = PNPND_NIF

     6) From the Configuration Main Window, choose "Login Environment
        Settings", then choose "Select Default Communication Driver"
        and "NDIS Ethernet".  Save the changes and exit to DOS.

     7) Edit CONFIG.SYS to add the following two lines:

             DEVICE=\PROTMAN.DOS /I=A:\  (if A drive is used)
             DEVICE=\PNPND.DOS

     8) Reboot the PC system.


   * Installation on Additional DOS Workstations

     1) Create a DOS boot diskette with DOS 3.1 or later.

     2) From an existing workstation, login to the server.  With the new
        boot diskette in the floppy drive, run PCCOPY. Select "NDIS Ether-
        net" and enter the following parameters:

             Interrupt Level: [interrupt_number]
             PROTOCOL.INI bindings = PNPND_NIF

        This will copy the VINES software to your boot diskette.

     3) Insert the boot diskette to any floppy drive of the working DOS
        workstation, repeat step 3 to 8 in "Installing on the First DOS
        Workstation".


   * Installation on the First OS/2 Workstation

      1) Insert the "Master Disk OS/2" diskette to any floppy drive and
         run VCLIENT.

      2) Choose "Install directory" (e.g., C:\VINES) and "NDIS Driver
         Ethernet' as the driver.

      3) Copy PNPND.OS2 and PROTOCOL.INI from the Ethernet Driver Disk
         to \VINES\DRIVERS\BN_NDIS\ND_ETH on your system.

      4) Edit CONFIG.SYS to change the following line:

              DEVICE=C:\VINES\DRIVERS\BN_NDIS\ND_ETH\<filename>
         to

              DEVICE=C:\VINES\DRIVERS\BN_NDIS\ND_ETH\PNPND.OS2

      5) Modify PROTOCOL.INI under \VINES\DRIVERS\BN_NDIS\ND_ETH, as
         shown below.

              [protocol manager]
                    drivername=PROTMAN$
              [VINES_XIF]
                    drivername=NETBEUI$
                    bindings=PNPND_NIF
              [PNPND_NIF]
                    drivername=PNPND$

      6) Change the current directory to VINES and run PCCONFIG to confi-
         gure your PC network, if necessary.

      7) Shut down OS/2 system and reboot.

      8) At the OS/2 prompt, change the directory to VINES and run BAN.


   * Installation on Additional OS/2 Workstations

     Step 1: Setup "Installation Diskette"

      1) From an existing workstation, login to the server.

      2) Insert a formatted 2HD diskette to any floppy drive. Run VCLIENT
         and select "Build an Install Diskette" item from the menu. Then,
         fill in VINES Directory Selection and FD Driver (e.g. C:\VINES
         and A:) to start the process.

      3) Choose "NDIS Ethernet" when you are asked to choose a driver.

      4) At the OS/2 prompt, change the drive letter to the drive where
         the "Installation Diskette" is located (e.g., A:),  and run
         PCCONFIG to configure your PC network.


     Step 2 : Install Drivers on the OS/2 Workstation

      5) Replace "Master Disk OS/2" diskette with the Install Diskette
         built in step 2; follow the procedure described in "Installation
         on the First OS/2 Workstation" to install.

             Interrupt Level: [interrupt_number]
             PROTOCOL.INI bindings = PNPND_NIF

         This will copy the VINES software to your boot diskette.

      6) Insert the boot diskette to any floppy drive of the working DOS
         workstation, repeat step 3 to 8 in "Installation on the First
         OS/2 Workstation".


3.3 Sitka 10NET Installation

    1) While installing 10NET, choose "None of the above" when you are
       asked to select the type of your LAN card.

    2) In DOS, copy PNPND.DOS and PROTOCOL.INI to the directory in which
       10Net is located.

    3) Edit CONFIG.SYS to add the following lines to the end of file:

             DEVICE=C:\10NET\10PROT.DOS /I:C:\10NET
             DEVICE=C:\10NET\10BEUI.DOS
             DEVICE=C:\10NET\PNPND.DOS

    4) Edit AUTOEXEC.BAT to add the following line to the beginning of
       the file:

              C:\10NET\10BIND

    5) Edit C:\10NET\PROTOCOL.INI as follows.

       - If the Operating Mode in DIAG has been set as Plug & Play
         mode, you should use any text editor to edit the following lines
         in your PROTOCOL.INI:

                   [protocol manager]
                         drivername=PROTMAN$
                   [10BEUI]
                         drivername="10BEUI$"
                         sessions=10
                         packets=40
                         stackcount=6
                         bindings=PNPND_NIF
                   [PNPND_NIF]
                         drivername=PNPND$

       - If the Operating Mode in DIAG has been set as Jumperless mode,
         you should use any text editor to edit the following lines in
         your PROTOCOL.INI:

                   [protocol manager]
                         drivername=PROTMAN$
                   [10BEUI]
                         drivername="10BEUI$"
                         sessions=10
                         packets=40
                         stackcount=6
                         bindings=PNPND_NIF
                   [PNPND_NIF]
                    drivername=PNPND$
                    IOBASE=0x300
                    INTERRUPT=3

         Note: You should change the INTERRUPT and IOBASE according
               to the hardware settings.

    6) Reboot the PC system.


3.4 DEC Pathworks Installation

    1) Copy all files under \NDIS2 from the Ethernet Driver Disk to the
       \NDIS2 directory of DEC Pathworks Client Setup Disk (create the
       directory if it does not exist).

    2) Insert DEC Pathworks Setup Disk into any floppy drive and run
       NETSETUP.EXE.

    3) Select "Yes" or "No" to confirm the type of your keyboard.

    4) Select DECNET and insert PWRKS 4.0 DNET TRANSPORT Disk 1 when
       prompted for.

    5) Take actions according to the screen instructions.  If you need,
       you can create an initial workstation diskette when you are asked
       to.

    6) Enter the destination drive letter in which the client drivers are
       to be installed when prompted for.  For example, "C".

    7) Press <Enter> to continue.

    8) When the installation is completed, press F10 to exit the setup
       utility.

    9) Modify the "SHELL=" line in your CONFIG.SYS as follows:

           SHELL=\COMMAND.COM /P /E:1024

   10) Reboot your PC to make the changes take effect.

   11) Run STARTNET.BAT from the \DECNET directory on your system.


3.5 Artisoft LANBIOS/AI 6.0 Installation

    In order to install a driver for LANtastic 6.0, you must reinstall
    LANtastic 6.0.

   1) Insert LANtastic Network Software 6.0 Disk 1 into your floppy drive.
      At the DOS prompt, type "INSTALL" and press <Enter> to start the LAN-
      tastic installation process.

   2) Artisoft's installation program will search for Microsoft Windows on
      your system.  If Windows not found, press <Enter> at the message to
      run the installation program under DOS.

   3) When you are asked to specify the desired driver, select "NDIS sup-
      port for Network Adapters".

   4) Insert the Ethernet Driver Disk that contains the NDIS driver for
      LANtastic 6.0 into the floppy drive, and then enter the path name
      where the driver is located.  For example, B:\NDIS2.

   5) Follow the instructions on the screen to complete the installation
      for LANtastic 6.0.  See the documentation coming with the LANtastic
      6.0 network software for more information.

   6) Reboot your PC.


Download Driver Pack

How To Update Drivers Manually

After your driver has been downloaded, follow these simple steps to install it.

  • Expand the archive file (if the download file is in zip or rar format).

  • If the expanded file has an .exe extension, double click it and follow the installation instructions.

  • Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.

  • Find the device and model you want to update in the device list.

  • Double-click on it to open the Properties dialog box.

  • From the Properties dialog box, select the Driver tab.

  • Click the Update Driver button, then follow the instructions.

Very important: You must reboot your system to ensure that any driver updates have taken effect.

For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.

server: web1, load: 1.13