Readme.txt Driver File Contents (CV_Setup_J5DY0_A27_ZPE.exe)


                        Broadcom (R) Corporation                  
                            Broadcom USH CD 
                   for the BCM5880/BCM5882 USH product

                      RELEASE 2.2.00117.22.7.133.0B
					  
                             (06/04/2012)

                             RELEASE NOTES


These notes describe release software for the BCM5880 USH Product
For release version information for individual products, see the 
"Release Version Information Table" below.

Software Compatibility
======================

This release of software supports:
- BCM5880 USH with A0/B0/C0 step silicon version.
- BCM5882 USH with A0/B0 step silicon version.


Upgrading from the Previous Driver Release
==========================================

It is highly recommended that you upgrade any previous installations
of the Broadcom BCM5880/BCM5882 USH software.

    If you are installing on a platform that is currently running DCP version 1.3 
    or earlier (with USH firmware 1.3 or earlier), the upgrade to DCP version 2.2
    (and USH firmware 2.2) MUST occur in the following order:

    1) Upgrade firmware to 2.2
    2) Upgrade USH host components to 2.2

    
Contents of the CD
==================

*** Release Version Information Table ***

    Product                                Version        Previous Rel.  
                
1.  USH Firmware                        22.7.133.0        22.7.133.0
2.  MA Bios-Driver                           4.0.4        4.0.4
3.  MP Bios-Driver                           4.0.4        4.0.4
4.  WinXp Drivers and Applications           4.1.3        4.1.3
5.  USH DOS Diagnostics                       2.17        2.17
6.  CV host software                         0.24G        0.24G
7.  CV host software 64 bit                  0.24G        0.24G    
8.  CV Firmware                           1.0.2.53        1.0.2.52
9.  Installer for host components that     2.2.117        2.2.117
    includes USH host components
10. Dell Data Protection | Prerequisites       A00        X08
11. Dell Data Protection | Application         X17        A02


This release contains the following software programs:

1) BCM5880 USH Firmware. Supports TPM 1.2 and PCSC. For more
   deatils, please refer to the release notes under firmware/

2) USH MA Bios-Driver. Supports TPM 1.2 for TPM bios access. For more
   details, please refer release notes under bios-driver/madriver 

3) USH MP Bios-Driver. Supports TPM 1.2 for TPM bios access. For more
   details, please refer release notes under bios-driver/mpdriver 

4) USH Windows XP TPM drivers and tpm applications which includes
   TPM Diagnostics and Firmware upgrade tool. For more details,
   please refer release notes under windowsxp/

5) CV host sofware that includes CV USB host driver, CV API user library,
   User DLL, and applications. For more details refer to release notes
   under windowsxp and windowsxp/cv

6) CV host software for XP 64 bit platform. Includes CV USB host driver,
   CV API user library, User DLL and applications.

7) Installer for host components. This includes CV, TPM and UCC components.



Changes/Additions
=================

In Release 2.2.0117.22.7.133.0B
===============================
-Firmware:
	- Added RFID config file for Vans15 and Vans17 platform
	
In Release 2.2.0117.22.7.133.0A
===============================
-Firmware:
	- added CID 7 images

In Release 2.2.0117.22.7.133.0
===============================
-Firmware, WPEUshdiag & DOS Ushdiag:
	- ESPSW-2288: DF548660, USH smart card test fail on Dalmore-14/15

In Release 2.2.0117.22.7.126.0E
===============================
-Firmware:
	- Added RFID config file for Dalmore 13" (533) platform.

In Release 2.2.0117.22.7.126.0D
===============================
- WPEUshdiag & WPEUshupgrade:
	- ESPSW-2229: DF535889, [Dalmore14/15] Failed to run "wpeushdiag.exe -u -Sid" in WPE MDX test process

In Release 2.2.0117.22.7.126.0C
===============================
-Firmware:
	- ESPSW-2245: [DDPA 2.2 RFID performance] It is difficult to pass CV RFID Mfg 3 Minutet test on Dalmore 14" and 15" ST systems: Added RFID config files for Dalmore 14" (534) and 15" (535) platforms.

In Release 2.2.0117.22.7.126.0B
===============================
- WPEUshupgrade:
	- ESPSW-2227: DF536212 , WPE USH F/W flash issue

In Release 2.2.0117.22.7.126.0A
===============================
-Firmware:
	- added CID 7 images

In Release 2.2.0117.22.7.126.0
===============================
-Firmware:
	- ESPSW-2199 [DDPA2.2]Fingerprint enrollment allows the same finger to be enrolled twice
	- ESPSW-2201 [DDPA2.2] Incorrect behavior with PBA "SC+FP" or "CLSC+ FP" for bad authentication
	
- Host components:
	- ESPSW-2194 [DDPA22] DDPA complains the CV admin password is incorrect after resuming from S3 or S4 with DDPA GUI opened 


In Release 2.2.0116.22.7.125.0
===============================
-Firmware:
	- ESPSW-2198 [DDPA 2.2] PBA direct show "Identification Failed - Press any key to continue" when warm boot system 
	- ESPSW-2128 DF509014 , Finger printer ESD issue on air discharge +/-2KV~+/-12KV (Dalmore 14 and 15)
	
In Release 2.2.0116.22.7.124.0
===============================
-Firmware:
	- ESPSW-2197 DF526290 , DDPA 2.2: Brooks with fingerprint/smartcard login intermittently fails on S3
	
In Release 2.2.0116.22.7.123.0
===============================
-Firmware:
	- ESPSW-2176 DF521912 , First FP swipe fails coming out of S4
	- Fix issue in PBA with getting “Identification failed” message w/o a FP swipe

- Host components:
	- ESPSW-2194/DF527140 [DDPA22] DDPA complains the CV admin password is incorrect after resuming from S3 or S4 with DDPA GUI opened 

In Release 2.2.0115.22.7.122.0
===============================
- Host components:
	- ESPSW-2192 [DDPA2.2] WAVE Gina login page only show "switch user " after system resume from S3

In Release 2.2.0114.22.7.122.0
===============================
-Firmware:
	- ESPSW-2175/DF521853: Mifare cards not working with DDPA; updated HID library
- Host components:
	- ESPSW-2188/DF524434: Incorrect Cred. Prov. logon screen with logon policy "SC or fingerprint" by CLSC

In Release 2.2.0113.22.7.121.0A
===============================
-Firmware:
	- added CID 7 images

	
In Release 2.2.0113.22.7.121.0
===============================
-Firmware:
	- address ESD failures found on X4 systems with Upek touch sensors

	
In Release 2.2.0113.22.7.120.0
===============================
-Firmware:
	- ESPSW-2128/DF509014: Finger printer ESD issue on air discharge +/-2KV~+/-12KV (Dalmore 14 and 15)

In Release 2.2.0113.22.7.119.0
===============================
-Firmware:
	- Fix for backdrive issue during S3
	- Partial fixes for ESPSW-2128/DF509014: Finger printer ESD issue on air discharge +/-2KV~+/-12KV (Dalmore 14 and 15)

In Release 2.2.0113.22.7.118.0
===============================
-Firmware:
	- Fix for backdrive issue during S3
- Host components:
	- ESPSW-2168: [DDPA2.2] Wave Gina temporary display "Contactless smartcard failure" about 2~3 seconds then switch to place card

In Release 2.2.0112.22.7.117.0
===============================
- Firmware:
	- ESPSW-2138 [DDPA2.2] E4 Dalmore 15": FW reset to SBI mode
	
In Release 2.2.0112.22.7.116.0
===============================
- Firmware:
	- ESPSW-2128 DF509014 , Finger printer ESD issue on air discharge +/-2KV~+/-12KV (Dalmore 14 and 15)
	- ESPSW-2159 Displaying the wrong text string in chkbios.bat
- Host Components:
	- ESPSW-2152 [DDPA2.2] Dalmore 14" - WAVE GINA doesn't appear after resume from S3
	- ESPSW-2160 DF514469 , Enrollment wizard is failing to validate incomplete/errored FP enrollments
	- ESPSW-2166 [DDPA2.2] intermittence - WAVE GINA shows failure after resume from S3
	- invalid SID found in registry caused failure


In Release 2.2.0111.22.7.115.0
===============================
- Firmware 22.7.115.0:
	- ESPSW-2149 [DDPA2.2] Dalmore 14” – no response for FP after wake up from S3 on WAVE GINA “smartcard or fingerprint”. 
- Host Components:
	- ESPSW-2149 [DDPA2.2] Dalmore 14” – no response for FP after wake up from S3 on WAVE GINA “smartcard or fingerprint”. 
	
In Release 2.2.0110.22.7.113.0
===============================
- Host Components:
	- ESPSW-2150 [DDPA22] The Driver showed "unsigned" in 32bit OS with the 2.2.00109.22.7.113.0 release
	
In Release 2.2.00109.22.7.113.0
===============================
- Firmware 22.7.113.0:
	- ESPSW-2046: [DDPA_wbf] Fingerpint showed " Failure" on the Wave GINA login screen after cover up E2 AT sersor 5-10 sec .
	- ESPSW-2139: The finger print sensor dosent recover seamlesly after bombarding the sensor with -8.0kv of esd charge (Air Discharge) for authentication.
	- ESPSW-2133: [2.2] Calling CSS_FingerprintEnroll returns 0x89 with a touch sensor
	
In Release 2.2.00108.22.7.112.0
===============================
- Host Components:
	- added WHQL signatures for all drivers
	
In Release 2.2.00107.22.7.112.0
===============================
- Firmware 22.7.112.0:
	- ESPSW-2131: [DDPA2.2] WMI "USHOnModule" Displayed "True" on X3 Platform
	- ESPSW-2132: [DDPA2.2] some of the smart cards are failed to detection
- Host Components:
	- ESPSW-2125: [2.2]BIP_API:CSS_DeleteObject returns 0x00000088(CV_INVALID_CAPTURE_ID) when deleting an auth type/CV_AUTH_FINGERPRINT obj

In Release 2.2.00106.22.7.111.0
===============================
- Firmware 22.7.111.0:
	- ESPSW-2126: [DDPA2.2] GINA returns Failure when swipe a bad fp
	- ESPSW-2125: [2.2]BIP_API:CSS_DeleteObject returns 0x00000088(CV_INVALID_CAPTURE_ID) when deleting an auth type/CV_AUTH_FINGERPRINT obj
	- Coverity fixes
- Host Components:
	- ESPSW-2125: [2.2]BIP_API:CSS_DeleteObject returns 0x00000088(CV_INVALID_CAPTURE_ID) when deleting an auth type/CV_AUTH_FINGERPRINT obj

In Release 2.2.00105.22.7.110.0
===============================
- Firmware 22.7.108.0/22.7.110.0:
    - ESPSW-2070/DF498686: CSC logon failure at Windows logon (SSO)
    - ESPSW-2097: CSS_GetObject/cssCVSaveSessionListToFile causes hang
    - ESPSW-2116: [DDPA2.2]USHOnModule properties are error
    - Fix for smart card coupler back-drive during suspend
    - Coverity fixes
	- Detection of USH on module
	- fix bug where bad swipe for raw FP capture resulted in CV_INVALID_OUTPUT_PARAMETER_LENGTH error
	- ESPSW-2096/DF503269: [PT_E15] USH smart card test fail
- Host Components:
    - ESPSW-2095: EXTRACTDRIVERS mode copies drivers into subfolders for unsupported OS'es
    - ESPSW-2089/DF503723: Broadcom USbccid Smartcard Reader(WUDF)-Not Digitally Signed
    - ESPSW-2093: [DDPA2.2] TPMEnabled and TPMPresent properties are error
    - ESPSW-2104: [DDPA22] TPM version is transulated wrong in WMI
    - ESPSW-2105: [DDPA22] CVHCI failed to execute in SBL mode
    - ESPSW-2017: 32bit CVHCI installer can be executed in 64bit OS
    - ESPSW-2086: Uninstalling CVHCI does not clean all installed files
	- ESPSW-2099: calling CSS_GetSessionCount returns 0x6(cv_get_session_count-Invalid Handle Value)
	- ESPSW-2109: [DDPA2.2]windows screen is stuck at "welcome" when resumes from s3 on E1 Roush
	- ESPSW-2112: [DDPA22]PBA function not bypass the Windows login screen when enrolled 5 FP users (different fingers)
	- ESPSW-2113: [2.2]CSS_GetObject should return the correct size of template buffer when the error "0x34" occurs
	- Coverity fixes
	- change CSS_GetInfo to return 2.0 for 5882 and 1.0 for 5880 (since it doesn't support async FP)

In Release 2.2.00103.22.7.107.0
===============================
- Firmware 22.7.107.0:
    - Coverity fixes
    - added firmware version in simple form to current_version file
- Host Components:
    - ESPSW-2085: disable WBDI endpoint during install
    - ESPSW-2084: [DDPA2.2] Memory leak during AST S3 test without swipe finger or scan CL card to logging into the Windows
    - ESPSW-2087: [DDPA2.2]Fingerpint showed " Failure" on the Wave GINA login screen after locking system over night


In Release 2.2.00102.22.7.105.0
===============================
- Firmware 22.7.105.0:
    - ESPSW-2068: [WBF]WBDI device disappeared when Take TPM ownership
    - Coverity fixes
- Host Components:
    - ESPSW-2080: CVHCI can not Uninstalling 
    - ESPSW-2083: check FW version during install
    - ESPSW-2057: WBF "bad swipe testing"

In Release 2.2.00101.22.7.104.0
===============================
- Firmware 22.7.104.0:
    - Partially address issue with FP functionality on resume from S3/S4
- Host Components:
    - ESPSW-2074: USHOnModule property value is reversed
    - ESPSW-2075: FPVendor and FPDevID properties are empty
    - WBDI device may not show up in control panel
    - Partially address issue with FP functionality on resume from S3/S4


In Release 2.2.00100.22.7.103.0
===============================
- 2.2 alpha release
- Firmware 22.7.103.0:
    - E4 detection logic using gpios
    - Gpio/SC power configuration changes to handle pwr states
    - FP performance optimization (except resume from S3 which is pending)
    - Updated Validity Library to 4.2.420:
		- associated USH firmware changes to address ESD issues when using hardware FP detect
    - DF456487: AT1660 ESD issues on Vida platform
    - DF456554: issue with the AT1660 sensor for low ESD hits (2KV contacted discharge
    - ESPSW-2070/DF498686: CSC logon failure at Windows logon (SSO)
	- ESPSW-2073: USH hang when tpm.msc launched during FP capture
- Host Components:
    - FP performance optimization (except resume from S3 which is pending)
    - ESPSW-2056: installer should not run on systems without CV
    - ESPSW-2072: create WMI API for querying device info
    - ESPSW-2037: implement MS support solution for ESPSW-2004 and ESPSW-1947
    - ESPSW-2054: [HCI] stop enabling WBDI interface during install
- USH Diag v1.1.0.22:
    - ESPSW-1985: Run USHdiag CV command: CV FP Duplicate Check in 64 bit OS will return 0x200008 error
        

Known Issues
============
- none
Download Driver Pack

How To Update Drivers Manually

After your driver has been downloaded, follow these simple steps to install it.

  • Expand the archive file (if the download file is in zip or rar format).

  • If the expanded file has an .exe extension, double click it and follow the installation instructions.

  • Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.

  • Find the device and model you want to update in the device list.

  • Double-click on it to open the Properties dialog box.

  • From the Properties dialog box, select the Driver tab.

  • Click the Update Driver button, then follow the instructions.

Very important: You must reboot your system to ensure that any driver updates have taken effect.

For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.

server: ftp, load: 2.94