Accton Technology Corporation Drivers
Installation For EN1653 and EN162x Ethernet Adapters
V1.00 07/05/93
Copyright (C) 1992, 1993 by Accton Technology Corporation.
All rights reserved.
The drivers NWMLID.COM, NW311.LAN, OS2MLID.SYS, ACC40.LAN can be used for the
following Accton Ethernet adapters:
ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
³ Product Name Product Number ³
ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
³ EtherPair-NE2 EN1622 ³
³ EtherCoax-NE2 EN1623 ³
³ EtherDuo-NE2 EN1653 ³
ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ
1. For your convenience, the Acc-10 Hardware Driver Disk is not
copy protected. Before you start with the installation
process, make a backup copy of this diskette. Use the
backup as your working diskette. Keep the original and use
it only to make backup copies.
ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
³ Novell Advanced NetWare 2.1x Driver Installation ³
ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ
1. Things You Need
ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
Before you start with the installation process make sure you have
the following :
a. ACCTON Acc-10 Hardware Driver Disk
b. Novell Advanced NetWare Disks :
AUXGEN, NETGEN and SHGEN_1 Disks
c. One formatted blank diskette
Volume name LAN_DRV_003
2. How To Install
ÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
2.1 OS Generation
a. Make a backup of your NetWare diskettes. Please refer
to your Novell Advanced NetWare Installation Manuals
for detailed description of the backup process. If
you have already done this operation, skip this step.
b. Insert the Acc-10 Hardware Driver Disk into drive A
and check the contents of subdirectory \NETWARE\V215.
It should contain the following files :
ANE2OS.OBJ ÄÄ¿
BNE2OS.OBJ ÄÄÅÄÄ Server Driver
CNE2OS.OBJ ÄÄ´
DNE2OS.OBJ ÄÄÙ
ACCNE2.LAN ÄÄÄÄÄ Configuration File
NE2SH.OBJ ÄÄÄÄÄ Shell Driver
c. Copy the ACCNE2.LAN file from the Acc-10 Hardware
Driver Disk into the NetWare diskette labeled
AUXGEN.
d. Use the 'FORMAT' command to format a blank diskette
and give the volume name LAN_DRV_003.
e. Copy the following driver files from the Acc-10
Hardware Driver Disk into the LAN_DRV_003 diskette :
ANE2OS.OBJ
BNE2OS.OBJ
CNE2OS.OBJ
DNE2OS.OBJ
NE2SH.OBJ
f. Insert the NetWare diskette NETGEN into drive A and
execute the NETGEN.EXE program. Follow the screen
instructions to change diskettes and select 'ACCTON
EtherCoax/Pair-NE(2) vx.xxRxx (yymmdd)' as the target
network adapter in the choice list. The NETGEN program
will generate the NetWare file server execution
program NET$OS.EXE automatically.
2.2 SHELL Generation
ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
a. Make the backup NetWare diskettes and check the
contents of the Acc-10 Hardware Driver Disk as
described in steps a and b of Section 2.2 (SHELL
Generation). If you have already done these
operations, skip this step.
b. Copy the ACCNE2.LAN file from the Acc-10 Hardware
Driver Disk into NetWare diskette labeled SHGEN-1.
c. Copy the following driver files from the Acc-10
Hardware Driver Disk into the LAN_DRV_003 diskette :
ANE2OS.OBJ
BNE2OS.OBJ
CNE2OS.OBJ
DNE2OS.OBJ
NE2SH.OBJ
d. Insert the NetWare diskette SHGEN-1 into drive
A and execute the SHGEN.EXE program. Follow the
screen instructions to change diskettes and select
'ACCTON NE2 Netware 2.15 Driver (Vxx-Rxx mm/dd/yy)'
as the target network adapter in the choice list. The
SHGEN program will generate the NetWare workstation
execution program IPX.COM automatically.
ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
³ Novell NetWare 386 Version 2.20 Driver Installation ³
ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ
1. How To Install
ÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
1.1 OS Generation
a. Make a backup of your NetWare diskettes. Please refer
to your Novell NetWare V2.20 Installation Manuals
for detailed description of the backup process. If
you have already done this operation, skip this step.
b. Insert the Acc-10 Hardware Driver Disk into drive A
and check the contents of subdirectory \NETWARE\V220.
It should contain the following files :
ANE2OS.OBJ ÄÄ¿
BNE2OS.OBJ ÄÄÅÄÄ Server Driver
CNE2OS.OBJ ÄÄ´
DNE2OS.OBJ ÄÄÙ
OS.LAN ÄÄÄÄÄ Server Configuration File
SHELL.LAN ÄÄÄÄÄ Workstation Configuration File
NE2SH.OBJ ÄÄÄÄÄ Shell Driver
c. Use the 'FORMAT' command to format a blank diskette
and give the volume name LAN_DRV_003.
d. Copy the following driver files from the Acc-10
Hardware Driver Disk into the LAN_DRV_003 diskette :
ANE2OS.OBJ
BNE2OS.OBJ
CNE2OS.OBJ
DNE2OS.OBJ
e. Copy the following driver file from the Acc-10
Hardware Driver Disk into the SYSTEM-1 diskette :
OS.LAN
f. Insert the NetWare diskette SYSTEM-1 into drive A and
execute the INSTALL program. Follow the screen
instructions to change diskettes and select 'ACCTON
EtherCoax/Pair-NE2 vx.xxRxx (yymmdd) ' as the target
network adapter in the choice list. The INSTALL program
will generate the NetWare file server execution
program NET$OS.EXE into OSEXE diskette automatically.
1.2 SHELL Generation
ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
a. Copy the SHELL.LAN and EP0100SH.OBJ file from the Acc-10
Hardware Driver Disk into NetWare diskette labeled WSGEN.
b. Insert the NetWare diskette WSGEN into drive A:
and execute the WSGEN.EXE program. Follow the
screen instructions to change diskettes and select
'ACCTON EtherCoax/Pair-NE2 vx.xxRxx (yymmdd) ' as the
target network adapter in the choice list. The WSGEN
program will generate the NetWare workstation
execution program IPX.COM automatically.
ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
³ Novell NetWare Version 386 Version 3.10 Driver Installation³
ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ
1. Things You Need
ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
Before you start with the installation process make sure you have
the following :
a. Acc-10 Hardware Driver Disk
b. Novell NetWare 386 Version 3.10 System Diskette
2. How To Install O.S. Driver
ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
a. Insert the Acc-10 Hardware Driver Disk into drive A
and check the contents of subdirectory \NETWARE\V310.
It should contain the following file :
NETWO31.LAN ÄÄÄ Novell NetWare 386 V3.10 Driver
b. Copy the contents of the Novell NetWare 386 Version
3.10 System Diskette into your NetWare 386 server
station hard disk. Please refer to your Novell
NetWare 386 Installation Manual for details.
c. Copy the NETWO31.LAN file from the Acc-10 Hardware
Driver Disk into the NetWare 386 server station hard
disk.
d. Run SERVER.EXE on the server station. Several NetWare
messages will be shown on-screen.
e. At the NetWare 386 prompt (indicated by a colon), run
the driver program, type :
: LOAD [d:]NETWO31 <Enter>
(Command Syntax : LOAD [d:]<Driver Name>)
Follow the instructions to select the appropriate
adapter configuration, Allowable values for these
parameters will also be shown on-screen. When you
load the driver program, your screen will display the
following messages :
Loading module NETWO31.LAN
Supported slot value are : 2
Slot:2
f. Bind IPX with ACCTON LAN driver, at the Netware server
prompt, type :
:BIND IPX NETWO31 <Enter>
After pressing <Enter> the computer prompts you for
the Network Number. For details on how to assign this
number, please consult your NetWare 386 Installation
Manual.
If problems occur during the binding process, your
screen will prompt you with error messages. Please
refer to your NetWare 386 manual for details on these
messages. The LAN driver installation is completed
when you see the following message on-screen :
IPX LAN Protocol bound to ACCTON EtherCoax/Pair-NE(2)
vx.xxRxx (yymmdd).
3. How To Install Shell Driver
ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
1. Make sure that the original NetWare diskettes have been
duplicated for backup purpose. If you have already duplicated
the diskettes, skip this step. Please refer to Novell NetWare
Installation Manuals for detailed description of the backup
process.
2. Insert the Acc-10 Ethernet Driver Disk into drive A:, and
check the contents of the subdirectory \NETWARE\V310. There
should be 3 NetWare 3.10 driver programs in the subdirectory:
NETWO31.LAN ----- Server Driver
NE2SH.LAN ----- Configuration File
NE2SH.OBJ ----- Shell Driver
3. Copy the NE2SH.LAN and NE2SH.OBJ file into the NetWare
diskette labeled SHGEN-1.
4. Insert the NetWare diskette SHGEN-1 into drive A:, then
execute the SHGEN.EXE program. From the menu shown on your screen,
choose 'Select LAN Driver from List' and press <Enter>. Then,
choose the target network adapter by selecting, 'ACCTON EtherCoax
/Pair-NE(2) vx.xxRxx' from the choice list. This will allow
SHGEN program to generate the NetWare workstation execution program
IPX.COM automatically.
ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
³ Novell NetWare 386 Version 3.11 Driver Installation ³
ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ
1. Things You Need
Before you start with the installation process make sure you have
the following :
a. Accton Driver Diskette
b. Novell NetWare 386 Version 3.11 System Diskette
2. How To Install O.S. Driver
a. Insert the Accton Driver Diskette into drive A
and check the contents of subdirectory \NETWARE\V311
It should contain the following file :
NW311.LANÄÄÄ Novell NetWare 386 V3.11 Server Driver
b. Copy the contents of the Novell NetWare 386 Version
3.11 System Diskette into your NetWare 386 server
station hard disk. Please refer to your Novell
NetWare 386 Installation Manual for details.
c. Copy the NW311.LAN file from the Hardware Driver Disk
into the NetWare 386 server station hard disk.
d. Run SERVER.EXE on the server station. Several NetWare
messages will be shown on-screen.
e. At the NetWare 386 prompt (indicated by a colon), run
the driver program, type :
: LOAD [d:]NW311 <Enter>
(Command Syntax : LOAD [d:]<Driver Name>)
Follow the instructions to select the appropriate
adapter configuration, Allowable values for these
parameters will also be shown on-screen. When you
load the driver program, your screen will display the
following messages :
Loading module NW311.LAN
Supported slot value are : 2
Slot:2
f. Bind IPX with Accton LAN driver, at the NetWare server
prompt, type :
:BIND IPX NW311 <Enter>
After pressing <Enter> the computer prompts you for
the Network Number. For details on how to assign this
number, please consult your NetWare 386 Installation
Manual.
If problems occur during the binding process, your
screen will prompt you with error messages. Please
refer to your NetWare 386 manual for details on these
messages. The LAN driver installation is completed
when you see the following message on-screen :
IPX LAN Protocol bound to Accton MPX Driver vx.xxRxx (yymmdd).
3. How To Install Shell Driver
ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
1. Make sure that the original NetWare diskettes have been
duplicated for backup purpose. If you have already duplicated
the diskettes, skip this step. Please refer to Novell NetWare
Installation Manuals for detailed description of the backup
process.
2. Insert the Acc-10 Hardware Driver Disk into drive A:, and
check the contents of the subdirectory \NETWARE\V311. There
should be 3 NetWare 3.11 driver programs in the subdirectory:
NW311.LAN ----- Server Driver
SHELL.LAN ----- Workstation Configuration File
NE2SH.OBJ ----- Workstation Driver
3. Copy the SHELL.LAN and NE2SH.OBJ file into the NetWare
diskette labeled WSGEN.
4. Insert the NetWare diskette WSGEN into drive A:, then
execute the WSGEN.EXE program. From the menu shown on your screen,
choose the target network adapter by selecting, 'ACCTON EtherCoax
/Pair-NE2 vx.xxRxx (yymmdd)' from the choice list. This will allow
SHGEN program to generate the NetWare workstation execution program
IPX.COM automatically.
ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
³ Novell NetWare Version 386 DOS ODI Driver Installation ³
ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ
1. Things You Need
Before you start with the installation process make
sure you have the following :
a) Accton Hardware Driver Disk
b) Novell DOS ODI WORKSTATION SERVICES diskette.
After boot your workstation, type following comments on the console:
LSL <Enter>
NWMLID <Enter>
IPXODI <Enter>
NETx <Enter> ----------- Dos Shell for NewWare
V3.11
or
VLM <Enter> ----------- Dos Requster for NetWare
v4.0 and backward
compatible.
then,you can log in to the file server.
If NIC driver, NWMLID executed successfully, it would inform you
the adapter mode and related configurations. Otherwise you would
see some error messages telling you by what reason the driver did
not reside. You can specify the problem and correct it easily.
Here is the list of error messages the driver may display and correction
method we suggested:
"The board cannot be found."
The adapter does not exist or driver does not recognize the adapter.
Correction: Plug Accton adapter into your PC bus slot.
"Board RAM failed the memory test."
The RAM buffer on the adapter failed.
Correction: Change a new adapter to run driver again.
"The board did not respond to the initialization command."
The driver recognized the adapter but the adapter fail to respond.
Correction: Change a new adapter to run driver again.
"There is no cable connecting to adapter."
There is no cable connecting to adapter or the transceiver within
adapter is failed.
Correction: Connect the cable to adapter and run driver again.
Normally, you will not need a NET.CFG file because the established
defaults should be adequate for your network. Besides, the automatic
configuration property can eliminate the necessity of NET.CFG.
Note: ODI driver is always parsing your NET.CFG file first. If the
related adapter's configuration parameters is found, they
will be recognized as preferred setting, even thought it
conflicts with parameters store in EEPROM of adapter. Thus
it will fail to initialize the adapter.
Bellow is a sample NET.CFG file:
LINK DRIVER NWMLID
INT 2
PORT 2020
SLOT 3
:
:
You can see NetWare 386 Installation appendix E for more information
about NET.CFG.
Novell has already changed the Ethernet default frame type to 802.2
starting with the release of NetWare v4.0. The move has to be made to
enable it to better support future protocol and networking features.
Some of these features are IPX with checksum, security enhancements,
and protocol independence. Following this change, the default frame
type of DOS ODI driver is Ethernet 802.2 when there is no protocol
binding in NET.CFG file. At this situation if your server is not
NetWare v4.0, please make sure the Ethernet 802.2 frame type has been
bound already before logging in it.
ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
³ Novell NetWare OS/2 ODI Driver Installation ³
ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ
1. Things You Need
Before you start with the installation process make
sure you have the following :
a. Accton Driver Diskette
b. Novell NetWare OS/2 WORKSTATION SERVICES REQUESTER diskette.
c. Novell NetWare OS/2 WORKSTATION OS/2 Utility - 1
d. Novell NetWare OS/2 WORKSTATION OS/2 Utility - 2
e. Novell NetWare OS/2 WORKSTATION OS/2 Utility - 3
2. How To Install
You need 1 file to acquire network service after installing OS/2
Requester and Utilities.
a. OS2MLID.SYS ---- supported by Accton
The directory OS2ODI contains only an OS/2 driver,(OS2MLID.SYS). This
driver must be usedwith the OS/2 requester to establish
networking operations. Make sure that the workstation on which you
want to install the Requester is a 286 or 386 machine that
will run OS/2 or Extended Edition OS/2. Please consult 'Novell
NetWare Requester for OS/2' for detailed Requester and Utilities
installation guide. After installation, the only thing you need to do
is to copy OS2MLID.SYS to NETWARE subdirectory and add or replace
OS2MLID.SYS before IPX.SYS in CONFIG.SYS. Such that those commands
sequence following will appear in your config.sys file.
DEVICE=C:\NETWARE\LSL.SYS ; OS/2 Requester supported
DEVICE=C:\NETWARE\DDAEMON.SYS ; OS/2 Requester supported
DEVICE=C:\NETWARE\OS2MLID.SYS ; Accton supported
DEVICE=C:\NETWARE\IPX.SYS ; OS/2 Requester supported
Reboot your system to get service of network.
Note: There is a suggestion provided by Accton Designers of this
driver to guarantee it work properly. We suggest that frame
type which you want to bind to IPX protocol will be specified
by 'FRAME' command in the first line among those supported
frame types. Such a NET.CFG file is as below:
Link Driver OS2MLID
frame Ethernet_802.3
frame Ethernet_802.2
frame Ethernet_II
frame Ethernet_snap
protocol IPX 00 Ethernet_802.3
For more information on NET.CFG parameters, see "NetWare
Workstation for DOS", "ODI for DOS User's Guide" or "NetWare
Requester for OS/2".
ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
³ Novell NetWare V4.0 Server Driver Installation ³
ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ
1. Things You Need
Before you start with the installation process make sure you have
the following :
a. Accton Driver Diskette
b. Novell NetWare Version 4.0 System Diskettes or CD ROM
2. How To Install O.S. Driver
a. Insert the Accton Driver Diskette into drive A
and check the contents of subdirectory \NETWARE\V400
It should contain the following file :
ACC40.LANÄÄÄ Novell NetWare V4.0 Server Driver
b. Copy the contents of the Novell NetWare Version 4.0
from System Diskette or CD ROM into your NetWare
server station hard disk. Please refer to your
Novell NetWare Installation Manual for details.
c. Copy the ACC40.LAN file from the Hardware Driver Disk
into the NetWare server station hard disk.
d. Run SERVER.EXE on the server station. Several NetWare
messages will be shown on-screen.
e. At the NetWare prompt (indicated by the Server name), run
INSTALL.NLM program, type :
server name: LOAD INSTALL <Enter>
Select 'Maintenance/Selective Install' <Enter>
And then select 'LAN Driver Options (Configure/Load/...)' <Enter>
After that you will see ACC40.LAN appear as an item under
'Select a LAN Driver' menu. Select it to start the driver
loading and binding procedure.
Follow the instructions to select the appropriate
adapter configuration, Allowable values for these
parameters will also be shown on-screen. When you
load the driver program, your screen will display the
following messages :
Loading module ACC40.LAN
Supported slot value are : 2
Slot:2
If problems occur during the binding process, your
screen will prompt you with error messages. Please
refer to your NetWare 386 manual for details on these
messages. The LAN driver installation is completed
when you see the following message on-screen :
IPX LAN protocol bound to Accton MPX Driver vx.xxRxx (yymmdd).
Note 1: The architecture of V.40 driver is different
with V3.11. You should load MSM.NLM and
ETHERTSM.NLM modules separately before loading
ACC40.LAN. When loading ACC40.LAN, it will check
whether these two modules have been loaded, if
not, it will load them automatically. So after
ACC40.LAN is loaded, if you type 'MODULES' command
under prompt, you will see two extra modules
MSM.NLM and ETHERTSM.NLM were loaded also.
Note 2: The default frame type ACC40.LAN binding is
Ethernet_802.2 not Ethernet_802.3. This is the
difference between V3.11 and V4.0 driver. ACC40.LAN
will support NetWare V3.11 environment also. But
you must load some patch NLMs before loading it.
Under this circumstance, there are some unpredictable
faults. So we do not suggest this solution.
Novell, NetWare, NE2000, NE1000, Novell Advanced NetWare are
registered trademarks of Novell Incorporated. Ethernet is registered
trademark of Xerox Corporation. EtherPair , EtherCoax are
registered trademark of Accton Technology Corporation. Other
marks mentioned here but unintentionally omitted are trademarks
or registered trademarks of their respective companies.
Download Driver Pack
After your driver has been downloaded, follow these simple steps to install it.
Expand the archive file (if the download file is in zip or rar format).
If the expanded file has an .exe extension, double click it and follow the installation instructions.
Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.
Find the device and model you want to update in the device list.
Double-click on it to open the Properties dialog box.
From the Properties dialog box, select the Driver tab.
Click the Update Driver button, then follow the instructions.
Very important: You must reboot your system to ensure that any driver updates have taken effect.
For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.