LM-SENSORS-MIB.txt Driver File Contents (pre_TPG0590_v7.1.13__VC.zip)

LM-SENSORS-MIB DEFINITIONS ::= BEGIN

--
-- Derived from the original VEST-INTERNETT-MIB. Open issues:
--
-- (a) where to register this MIB?
-- (b) use not-accessible for diskIOIndex?
--


IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE, Integer32, Gauge32
        FROM SNMPv2-SMI
    DisplayString
        FROM SNMPv2-TC
    ucdExperimental
        FROM UCD-SNMP-MIB;

lmSensorsMIB MODULE-IDENTITY
    LAST-UPDATED "200011050000Z"
    ORGANIZATION "AdamsNames Ltd"
    CONTACT-INFO    
        "Primary Contact: M J Oldfield
         email:     m@mail.tc"
    DESCRIPTION
        "This MIB module defines objects for lm_sensor derived data."
    REVISION     "200011050000Z"
    DESCRIPTION
        "Derived from DISKIO-MIB ex UCD."
    ::= { lmSensors 1 }

lmSensors      OBJECT IDENTIFIER ::= { ucdExperimental 16 }

--

lmTempSensorsTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF LMTempSensorsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of temperature sensors and their values."
    ::= { lmSensors 2 }

lmTempSensorsEntry OBJECT-TYPE
    SYNTAX      LMTempSensorsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry containing a device and its statistics."
    INDEX       { lmTempSensorsIndex }
    ::= { lmTempSensorsTable 1 }

LMTempSensorsEntry ::= SEQUENCE {
    lmTempSensorsIndex    Integer32,
    lmTempSensorsDevice   DisplayString,
    lmTempSensorsValue    Gauge32
}

lmTempSensorsIndex OBJECT-TYPE
    SYNTAX      Integer32 (0..65535)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Reference index for each observed device."
    ::= { lmTempSensorsEntry 1 }

lmTempSensorsDevice OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The name of the temperature sensor we are reading."
    ::= { lmTempSensorsEntry 2 }

lmTempSensorsValue OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The temperature of this sensor in mC."
    ::= { lmTempSensorsEntry 3 }
--

lmFanSensorsTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF LMFanSensorsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of fan sensors and their values."
    ::= { lmSensors 3 }

lmFanSensorsEntry OBJECT-TYPE
    SYNTAX      LMFanSensorsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry containing a device and its statistics."
    INDEX       { lmFanSensorsIndex }
    ::= { lmFanSensorsTable 1 }

LMFanSensorsEntry ::= SEQUENCE {
    lmFanSensorsIndex    Integer32,
    lmFanSensorsDevice   DisplayString,
    lmFanSensorsValue    Gauge32
}

lmFanSensorsIndex OBJECT-TYPE
    SYNTAX      Integer32 (0..65535)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Reference index for each observed device."
    ::= { lmFanSensorsEntry 1 }

lmFanSensorsDevice OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The name of the fan sensor we are reading."
    ::= { lmFanSensorsEntry 2 }

lmFanSensorsValue OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The rotation speed of the fan in RPM."
    ::= { lmFanSensorsEntry 3 }

--

lmVoltSensorsTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF LMVoltSensorsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of voltage sensors and their values."
    ::= { lmSensors 4 }

lmVoltSensorsEntry OBJECT-TYPE
    SYNTAX      LMVoltSensorsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry containing a device and its statistics."
    INDEX       { lmVoltSensorsIndex }
    ::= { lmVoltSensorsTable 1 }

LMVoltSensorsEntry ::= SEQUENCE {
    lmVoltSensorsIndex    Integer32,
    lmVoltSensorsDevice   DisplayString,
    lmVoltSensorsValue    Gauge32
}

lmVoltSensorsIndex OBJECT-TYPE
    SYNTAX      Integer32 (0..65535)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Reference index for each observed device."
    ::= { lmVoltSensorsEntry 1 }

lmVoltSensorsDevice OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The name of the device we are reading."
    ::= { lmVoltSensorsEntry 2 }

lmVoltSensorsValue OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The voltage in mV."
    ::= { lmVoltSensorsEntry 3 }

--

lmMiscSensorsTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF LMMiscSensorsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of miscellaneous sensor devices and their values."
    ::= { lmSensors 5 }

lmMiscSensorsEntry OBJECT-TYPE
    SYNTAX      LMMiscSensorsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry containing a device and its statistics."
    INDEX       { lmMiscSensorsIndex }
    ::= { lmMiscSensorsTable 1 }

LMMiscSensorsEntry ::= SEQUENCE {
    lmMiscSensorsIndex    Integer32,
    lmMiscSensorsDevice   DisplayString,
    lmMiscSensorsValue    Gauge32
}

lmMiscSensorsIndex OBJECT-TYPE
    SYNTAX      Integer32 (0..65535)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Reference index for each observed device."
    ::= { lmMiscSensorsEntry 1 }

lmMiscSensorsDevice OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The name of the device we are reading."
    ::= { lmMiscSensorsEntry 2 }

lmMiscSensorsValue OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of this sensor."
    ::= { lmMiscSensorsEntry 3 }


END
Download Driver Pack

How To Update Drivers Manually

After your driver has been downloaded, follow these simple steps to install it.

  • Expand the archive file (if the download file is in zip or rar format).

  • If the expanded file has an .exe extension, double click it and follow the installation instructions.

  • Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.

  • Find the device and model you want to update in the device list.

  • Double-click on it to open the Properties dialog box.

  • From the Properties dialog box, select the Driver tab.

  • Click the Update Driver button, then follow the instructions.

Very important: You must reboot your system to ensure that any driver updates have taken effect.

For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.

server: web2, load: 1.43