IMPORTANT INFORMATION FOR FIRMWARE-UPDATE TO VERSION v5.213/5.502 THE PARAMETER WILL BE ADOPTED DURING THE FIRMWARE UPDATE. NEW PARAMETER WILL BE SET WITH THE DEFAULT VALUES. FOR MORE DETAILED INFORMATION, SEE THE RESPECTIVE SUPPLEMENTARY DESCRIPTION. General: ======== This firmware supports the device SUNNY ISLAND 5048. The update is being done by copying the file "UPDATE.BIN" to a SD/MMC-Card and inserting this card into the SD/MMC-card slot of the SUNNY ISLAND 5048 MASTER UNIT, which is in STAND BY mode. Slave devices which are connected to the Master unit via communication do not have to be updated explicitly. The Master unit is updating the Slave units automatically. If a Slave unit has been updated accidentally while the Master unit still has the older version of the software, this will be detected by the Master unit and the Slave unit will be set to the version of the Master unit automatically. CAUTION: This firmware version is for SUNNY ISLAND 5048 only and not for other devices of the SUNNY ISLAND family. By updating the firmware, no parameter which has been set in advance will be deleted as long as this is not explicitly explained in this text file. For safety reasons the parameter list should be stored on the SD/MMC-Card (please see manual: "Store and load parameters") Important information: ====================== After the update, the generator is requested to initiate a full charge. Duration of the firmware update: ================================ Updating single-phase systems takes 5 - 10 minutes. Depending on the system configuration with more than one Sunny Island, updating the software might take up to 20 minutes. A status bar shows the progress of the update. Leave the SD card in the Sunny Island until the update is finished and the display denotes "STNDBY: To Start INV hold <Enter> for single devices. In systems with several Sunny Island wait until the master displays "Update finished. Press Enter" and the slave displays "Ready wait for Master". During the update process, leave the DC disconnector to the "On" position. Changes to previous versions: ============================= Firmware release V3.015/3.009 (only for SI 5048) ================================================= - Optimized menu structure: e.g. Password setting at #260 instead of #280 - New feature: Grid voltage increase protection - New feature: Integrated voltage peak detection - New feature: The Sunny Boys' output power can now be controlled via the RS485 interface during main power grid operation - Improved Anti-Islanding technique: Bugs from unwanted disconnections have been eliminated - Generator management: Improved connection to AC bus (reverse power protection temporarily suppressed) - Changed Settings: Date and time settings are only possible in "stand by" mode - Battery management: If the maximum permission temperature is exceeded, the Sunny Island switches off. This upper limit is now adjustable. - MMC/SD-Card: Changed data file structure - MMC/SD-Card: Recording time 100 instead of 28 days - Enhanced firmware updates - Optimized short-circuit characteristics - Optimized generator statistics - No shut down after cable break of the battery temperature sensor any longer - New default values: - GnErrStpTm 1h (instead of 6h) - Stop time after the generator is manually started is set to 30 sec Firmware release V4.017/4.007 (only for SI 5048) ============================================================= - New feature: Multi-Cluster functionality - New feature: Adjustable Anti-Islanding sensitivity for grid and generator operation - Improved Quick Configuration Guide - Added failure and event lists - Optimized MMC/SD card features - Bugfix: Generator control (settings: GenMan, Manual) - Bugfix #222.12 AutoEquChrEna - Bugfix: Incorrect grid disconnection during voltage flicker corrected (Warning: W327-330) Firmware release v4.202/4.123 (only for SI 5048) ================================================ - New Feature: Assistance of the SIC-40 - New Feature: Generator will be stopped after a full charge cycle has been completed, not after the preadjusted SOC has been reached - Optimized Multi-Cluster functionality - Adaption: GenSocTm1Stp and GenSocTm2Stp can now be set up to 95% - Optimized BMS: Improved SOH calculation (see the update information for release 4) - Bugfix: Communication to SBC/SBC+ (channel list) - Bugfix: Internal communication improved (incorrect disconnection due to F739 fixed) - Bugfix: Synchronizing to a generator is now possible even if the battery voltage is low and the AC-voltage is high Firmware release v5.155/5.106 (for SI 5048 and SI 5048U) ======================================================== - Includes all features from previous firmware versions - Advanced firmware update with complete parameter transfer from older firmware versions - New feature: Assistance of all types of generators - New feature: Time dependent generator operation - New feature: Load dependent generator start - New feature: Grid as generator - New feature: Awaking from low battery mode 1 and 2 if a valid external voltage source is recognized - New feature: Events and Errors are displayed in number and correspondent short text - New feature: RunMode in case of a fault in 3-phase systems - New feature: Sleep at night - New feature: Compensation of battery lead resistance - New default parameter for the typical US market (e.g. BatTmpStr, BatTmpMax, ...) - New relay function: BatFan - Improved battery management - Improved sleep mode - Improved short circuit detection - Improved battery current calculation - Improved voltage measurement - Improved data logging on MMC/SD card - Improved start-up process to voltage source with fixed voltage - Improved automatic frequency control - Improved analysis of Multi-Cluster box signals - Improved generator management - Improved reverse power protection - Adjustable CAN-Bus-Speed - Manuell start of cluster update via parameter - Automatic reset of the autostart counter after 10 min Firmware release v5.213/5.502 (only for SI 5048) ======================================================== - Includes all features from previous firmware versions - Bug fixing: - Improved time dependent generator operation - Improved load dependent generator operation - Improved SOC (State-Of-Charge) dependent generator operation - BatTmpHigh recognition - Improved error recognition „SlaveLoss“ - Improved error recognition „ExtVtgLo“ - Improved voltage increase protection - Improved Multicluster support - Improved automatic parameter savings - New parameter: TotMccLodPwr (Total Multicluster Load Power)Download Driver Pack
After your driver has been downloaded, follow these simple steps to install it.
Expand the archive file (if the download file is in zip or rar format).
If the expanded file has an .exe extension, double click it and follow the installation instructions.
Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.
Find the device and model you want to update in the device list.
Double-click on it to open the Properties dialog box.
From the Properties dialog box, select the Driver tab.
Click the Update Driver button, then follow the instructions.
Very important: You must reboot your system to ensure that any driver updates have taken effect.
For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.