Chapter 3
Example Programs


3.1 RS-232C Visual Basic Example Programs


Example 1 Using a setting command

*Send the command in the format specified, when the conditions
  for the command to be acceptable are met.

Private Sub Command1_Click()
'*******************************************************************************
' RS232C SAMPLE PROGRAM NO.1
'*******************************************************************************

deli$ = Chr$(13) & Chr$(10)

MSComm1.PortOpen = True

MSComm1.Output = ":CONFIGURE:SAMPLE 100.0E-3" & deli$
MSComm1.Output = ":CONFIGURE:TDIV 1.0E+0" & deli$
MSComm1.Output = ":CONFIGURE:RECTIME 0,0,0,10" & deli$

MSComm1.Output = ":UNIT:STORE CH1,ON" & deli$
MSComm1.Output = ":UNIT:INMODE CH1,VOLTAGE" & deli$

MSComm1.Output = ":TRIGGER:SOURCE OR" & deli$
MSComm1.Output = ":TRIGGER:KIND CH1,LEVEL" & deli$
MSComm1.Output = ":TRIGGER:PRETRIG 0,0,0,5" & deli$
MSComm1.Output = ":TRIGGER:LEVEL CH1,0" & deli$
MSComm1.Output = ":TRIGGER:SLOPE CH1,UP" & deli$

MSComm1.Output = ":START" & deli$

MSComm1.PortOpen = False
End Sub



Example 2 Using a query

*Send the query in the format specified, when the conditions for
  the query to be acceptable are met.
*The response data from the query is returned in the format

Private Sub Command1_Click()
'*******************************************************************************
' RS232C SAMPLE PROGRAM NO.2
'*******************************************************************************

deli$ = Chr$(13) & Chr$(10)

MSComm1.PortOpen = True

MSComm1.Output = ":HEADER OFF" & deli$
MSComm1.Output = ":CONFIGURE:RECTIME?" & deli$
Do
sh$ = sh$ & MSComm1.Input
Loop Until InStr(1, sh$, Chr$(10))

MSComm1.Output = ":SYSTEM:TIME?" & deli$
Do
tm$ = tm$ & MSComm1.Input
Loop Until InStr(1, tm$, Chr$(10))

Text1.Text = "RECTIME = " & sh$
Text1.Text = Text1.Text & "TIME = " & tm$
MSComm1.PortOpen = False
End Sub



Example 3 Outputting stored data

*Using the :MEMORY:MAXPOINT? query, this program checks whether
  data can be output from memory. If this query returns zero,
  no data is stored, and it cannot therefore be output.
*Next, the program specifies the channel and point for output,
  using the :MEMORY:POINT command. As data is input or output,
  the point is incremented automatically. If capturing data
  consecutively, it is sufficient to specify the point once only.
*To capture data in ASCII format use the :MEMORY:ADATA? query,
  and to capture data as voltage values use the :MEMORY:VDATA?
  query.
  The number of data samples which may be output in one set is
  1 to 80 using :ADATA? and 1 to 40 using the :VDATA? query.
*Outputting data in bigger sets reduces the overall processing
  time.
*Read data (100+1 samples) for channel 1 when stored with
  a 100ms interval and 10sec recording time.

Private Sub Command1_Click()
'*******************************************************************************
' RS232C SAMPLE PROGRAM NO.3
'*******************************************************************************

deli$ = Chr$(13) & Chr$(10)
Dim d(100) As Double

MSComm1.PortOpen = True

MSComm1.Output = ":CONFIGURE:SAMPLE 100.0E-3" & deli$
MSComm1.Output = ":CONFIGURE:RECTIME 0,0,0,10" & deli$
MSComm1.Output = ":UNIT:STORE CH1,ON" & deli$
MSComm1.Output = ":TRIGGER:MODE SINGLE" & deli$
MSComm1.Output = ":START;:STOP;*OPC?" & deli$

Do
    o$ = o$ & MSComm1.Input
Loop Until InStr(1, o$, Chr$(10))

MSComm1.Output = ":HEADER OFF" & deli$
MSComm1.Output = ":MEMORY:MAXPOINT?" & deli$
Do
    mx$ = mx$ & MSComm1.Input
Loop Until InStr(1, mx$, Chr$(10))
If (Val(mx$) = 0) Then
    MSComm1.PortOpen = False
    Exit Sub
End If

MSComm1.Output = ":MEMORY:POINT CH1,0" & deli$
For i = 0 To 100
    vd$ = ""
    MSComm1.Output = ":MEMORY:VDATA? 1" & deli$
    Do
        vd$ = vd$ & MSComm1.Input
    Loop Until InStr(1, vd$, Chr$(10))
    d(i) = Val(vd$)
Next

For i = 0 To 100
    Text1.SelText = Format(d(i), "Scientific") & deli$
Next

MSComm1.PortOpen = False
End Sub




Example 4 Inputting storage data.

*This program prepares storage memory, using the :MEMORY:PREPARE
  command. 
*Next, the program specifies the channel and point for input,
  using the :MEMORY:POINT command, and then uses
  the :MEMORY:ADATA command to input data.

Private Sub Command1_Click()
'*******************************************************************************
' RS232C SAMPLE PROGRAM NO.4
'*******************************************************************************

deli$ = Chr$(13) & Chr$(10)

MSComm1.PortOpen = True

MSComm1.Output = ":CONFIGURE:SAMPLE 100.0E-3" & deli$
MSComm1.Output = ":CONFIGURE:RECTIME 0,0,0,10" & deli$
MSComm1.Output = ":UNIT:STORE CH1,ON" & deli$
MSComm1.Output = ":MEMORY:PREPARE;*OPC?" & deli$
Do
o$ = MSComm1.Input
Loop Until InStr(1, o$, Chr$(10))
MSComm1.Output = ":MEMORY:POINT CH1,0" & deli$
For i = 0 To 100
    MSComm1.Output = ":MEMORY:ADATA " & Str$(Int(10000 * Sin(3.14 * i / 50))) & deli$
Next

MSComm1.PortOpen = False
End Sub



Example 5 Checking the presence of input channel, and displaying
          the input ranges on the screen.

Private Sub Command1_Click()
'*******************************************************************************
' RS232C SAMPLE PROGRAM NO.5
'*******************************************************************************

deli$ = Chr$(13) & Chr$(10)

MSComm1.PortOpen = True

MAXCH = 8                                               '8420-51=8,8421-51=16,8422-51=32channels
Dim ch_data$(32 + 1)

MSComm1.Output = ":HEADER OFF" & deli$
MSComm1.Output = ":MEMORY:GETREAL" & deli$
                                                      

For ch = 1 To MAXCH
    MSComm1.Output = ":MEMORY:AREAL? CH" + Str$(ch) & deli$
    ar$ = ""
    Do
    ar$ = ar$ & MSComm1.Input
    Loop Until InStr(1, ar$, Chr$(10))
    ch_data$(ch) = "CH" + Str$(ch) + " = " & ar$
Next ch


For ch = 1 To MAXCH
    Text1.SelText = ch_data$(ch) & deli$
Next ch

MSComm1.PortOpen = False
End Sub


Example 6 Saving stored data onto drive A

Private Sub Command1_Click()
'*******************************************************************************
' RS232C SAMPLE PROGRAM NO.6
'*******************************************************************************

deli$ = Chr$(13) & Chr$(10)
na$ = "a:\sample.dat"

MSComm1.PortOpen = True

MSComm1.Output = ":HEADER OFF" & deli$
MSComm1.Output = ":MEMORY:MAXPOINT?" & deli$
Do
mx$ = mx$ & MSComm1.Input
Loop Until InStr(1, mx$, Chr$(10))
If (Val(mx$) = 0) Then
MSComm1.PortOpen = False
Exit Sub
End If

Open na$ For Output As #1
MSComm1.Output = ":MEMORY:POINT CH1,0" & deli$
Print #1, Val(mx$)
For i = 1 To Val(mx$)
    MSComm1.Output = ":MEMORY:ADATA? 1" & deli$
ad$ = ""
Do
ad$ = ad$ & MSComm1.Input
Loop Until InStr(1, ad$, Chr$(10))
Print #1, Val(ad$)
Next

Close #1
MSComm1.PortOpen = False
End Sub




Example 7 Reading the data saved in Example 6, and loading it into the unit.

Private Sub Command1_Click()
'*******************************************************************************
' RS232C SAMPLE PROGRAM NO.7
'*******************************************************************************

deli$ = Chr$(13) & Chr$(10)
na$ = "a:\sample.dat"

MSComm1.PortOpen = True

MSComm1.Output = ":HEADER OFF" & deli$
MSComm1.Output = ":MEMORY:PREPARE;*OPC?" & deli$
Do
o$ = MSComm1.Input
Loop Until InStr(1, o$, Chr$(10))

Open na$ For Input As #1
MSComm1.Output = ":MEMORY:POINT CH1,0" & deli$
Line Input #1, mx
For i = 1 To mx
    Line Input #1, dt
    MSComm1.Output = ":MEMORY:ADATA " & Str$(dt) & deli$
Next

Close #1
MSComm1.PortOpen = False
End Sub





3.2 10BASE-T Visual Basic Example Programs


Example 1 Using a setting command

*Send the command in the format specified, when the conditions
  for the command to be acceptable are met.



Dim MsgFlg As Integer
Dim MsgBuf As String

Private Sub Command1_Click()
'*******************************************************************************
' 10BASE-T(LAN) SAMPLE PROGRAM NO.1
'*******************************************************************************

deli$ = Chr$(13) & Chr$(10)

SendMsg ":CONFIGURE:SAMPLE 100.0E-3" & deli$
SendMsg ":CONFIGURE:TDIV 1.0E+0" & deli$
SendMsg ":CONFIGURE:RECTIME 0,0,0,10" & deli$

SendMsg ":UNIT:STORE CH1,ON" & deli$
SendMsg ":UNIT:INMODE CH1,VOLTAGE" & deli$

SendMsg ":TRIGGER:SOURCE OR" & deli$
SendMsg ":TRIGGER:KIND CH1,LEVEL" & deli$
SendMsg ":TRIGGER:PRETRIG 0,0,0,5" & deli$
SendMsg ":TRIGGER:LEVEL CH1,0" & deli$
SendMsg ":TRIGGER:SLOPE CH1,UP" & deli$

SendMsg ":START" & deli$

End Sub

Private Sub Command2_Click()

Winsock1.Protocol = sckTCPProtocol
Winsock1.RemoteHost = txtIP.Text
Winsock1.RemotePort = Val(txtPort.Text)

Winsock1.Connect

Do While (Winsock1.State <> sckConnected)
    If Winsock1.State = sckConnecting Then Text2.Text = "connecting"
    DoEvents
Loop
    If Winsock1.State = sckConnected Then Text2.Text = "finish"

End Sub

Private Sub Command3_Click()

Winsock1.Close

Do While (Winsock1.State <> sckClosed)
    If Winsock1.State = sckConnected Then Text2.Text = "disconecting"
    DoEvents
Loop
    If Winsock1.State = sckClosed Then Text2.Text = "finish"

End Sub

Private Sub SendMsg(strMsg As String)

Winsock1.SendData strMsg

End Sub

Private Sub GetMsg(strMsg As String)

MsgFlg = 0
    
Winsock1.SendData strMsg
    
Do While (MsgFlg = 0)
    DoEvents
Loop
    
End Sub

Private Sub Winsock1_DataArrival(ByVal bytesTotal As Long)

Winsock1.GetData MsgBuf, vbString
        
MsgFlg = 1

End Sub





Example 2 Using a query

*Send the query in the format specified, when the conditions for
  the query to be acceptable are met.
*The response data from the query is returned in the format



Dim MsgFlg As Integer
Dim MsgBuf As String

Private Sub Command1_Click()
'*******************************************************************************
' 10BASE-T(LAN) SAMPLE PROGRAM NO.2
'*******************************************************************************

deli$ = Chr$(13) & Chr$(10)

SendMsg ":HEADER OFF" & deli$
GetMsg ":CONFIGURE:RECTIME?" & deli$
sh$ = MsgBuf

GetMsg ":SYSTEM:TIME?" & deli$
tm$ = MsgBuf

Text1.Text = "RECTIME = " & sh$
Text1.Text = Text1.Text & "TIME = " & tm$

End Sub

Private Sub Command2_Click()

Winsock1.Protocol = sckTCPProtocol
Winsock1.RemoteHost = txtIP.Text
Winsock1.RemotePort = Val(txtPort.Text)

Winsock1.Connect

Do While (Winsock1.State <> sckConnected)
    If Winsock1.State = sckConnecting Then Text2.Text = "connecting"
    DoEvents
Loop
    If Winsock1.State = sckConnected Then Text2.Text = "finish"

End Sub

Private Sub Command3_Click()

Winsock1.Close

Do While (Winsock1.State <> sckClosed)
    If Winsock1.State = sckConnected Then Text2.Text = "disconecting"
    DoEvents
Loop
    If Winsock1.State = sckClosed Then Text2.Text = "finish"

End Sub

Private Sub SendMsg(strMsg As String)

Winsock1.SendData strMsg

End Sub

Private Sub GetMsg(strMsg As String)

MsgFlg = 0
    
Winsock1.SendData strMsg
    
Do While (MsgFlg = 0)
    DoEvents
Loop
    
End Sub

Private Sub Winsock1_DataArrival(ByVal bytesTotal As Long)

Winsock1.GetData MsgBuf, vbString
        
MsgFlg = 1

End Sub





Example 3 Outputting stored data

*Using the :MEMORY:MAXPOINT? query, this program checks whether
  data can be output from memory. If this query returns zero,
  no data is stored, and it cannot therefore be output.
*Next, the program specifies the channel and point for output,
  using the :MEMORY:POINT command. As data is input or output,
  the point is incremented automatically. If capturing data
  consecutively, it is sufficient to specify the point once only.
*To capture data in ASCII format use the :MEMORY:ADATA? query,
  and to capture data as voltage values use the :MEMORY:VDATA?
  query.
  The number of data samples which may be output in one set is
  1 to 80 using :ADATA? and 1 to 40 using the :VDATA? query.
*Outputting data in bigger sets reduces the overall processing
  time.
*Read data (100+1 samples) for channel 1 when stored with
  a 100ms interval and 10sec recording time.



Dim MsgFlg As Integer
Dim MsgBuf As String

Private Sub Command1_Click()
'*******************************************************************************
' 10BASE-T(LAN) SAMPLE PROGRAM NO.3
'*******************************************************************************

deli$ = Chr$(13) & Chr$(10)
Dim d(100) As Double

SendMsg ":CONFIGURE:SAMPLE 100.0E-3" & deli$
SendMsg ":CONFIGURE:RECTIME 0,0,0,10" & deli$
SendMsg ":UNIT:STORE CH1,ON" & deli$
SendMsg ":TRIGGER:MODE SINGLE" & deli$
GetMsg ":START;:STOP;*OPC?" & deli$
o$ = MsgBuf

SendMsg ":HEADER OFF" & deli$
GetMsg ":MEMORY:MAXPOINT?" & deli$
mx$ = MsgBuf
If (Val(mx$) = 0) Then
    Exit Sub
End If

SendMsg ":MEMORY:POINT CH1,0" & deli$
For i = 0 To 100
    vd$ = ""
    GetMsg ":MEMORY:VDATA? 1" & deli$
    vd$ = MsgBuf
    d(i) = Val(vd$)
Next

For i = 0 To 100
    Text1.SelText = Format(d(i), "Scientific") & deli$
Next

End Sub

Private Sub Command2_Click()

Winsock1.Protocol = sckTCPProtocol
Winsock1.RemoteHost = txtIP.Text
Winsock1.RemotePort = Val(txtPort.Text)

Winsock1.Connect

Do While (Winsock1.State <> sckConnected)
    If Winsock1.State = sckConnecting Then Text2.Text = "connecting"
    DoEvents
Loop
    If Winsock1.State = sckConnected Then Text2.Text = "finish"

End Sub

Private Sub Command3_Click()

Winsock1.Close

Do While (Winsock1.State <> sckClosed)
    If Winsock1.State = sckConnected Then Text2.Text = "disconecting"
    DoEvents
Loop
    If Winsock1.State = sckClosed Then Text2.Text = "finish"

End Sub

Private Sub SendMsg(strMsg As String)

Winsock1.SendData strMsg

End Sub

Private Sub GetMsg(strMsg As String)

MsgFlg = 0
    
Winsock1.SendData strMsg
    
Do While (MsgFlg = 0)
    DoEvents
Loop
    
End Sub

Private Sub Winsock1_DataArrival(ByVal bytesTotal As Long)

Winsock1.GetData MsgBuf, vbString
        
MsgFlg = 1

End Sub





Example 4 Inputting storage data.

*This program prepares storage memory, using the :MEMORY:PREPARE
  command. 
*Next, the program specifies the channel and point for input,
  using the :MEMORY:POINT command, and then uses
  the :MEMORY:ADATA command to input data.



Dim MsgFlg As Integer
Dim MsgBuf As String

Private Sub Command1_Click()
'*******************************************************************************
' 10BASE-T(LAN) SAMPLE PROGRAM NO.4
'*******************************************************************************

deli$ = Chr$(13) & Chr$(10)


SendMsg ":CONFIGURE:SAMPLE 100.0E-3" & deli$
SendMsg ":CONFIGURE:RECTIME 0,0,0,10" & deli$
SendMsg ":UNIT:STORE CH1,ON" & deli$
GetMsg ":MEMORY:PREPARE;*OPC?" & deli$
o$ = MsgBuf

SendMsg ":MEMORY:POINT CH1,0" & deli$
For i = 0 To 100
    SendMsg ":MEMORY:ADATA " & Str$(Int(10000 * Sin(3.14 * i / 50))) & deli$
Next


End Sub

Private Sub Command2_Click()

Winsock1.Protocol = sckTCPProtocol
Winsock1.RemoteHost = txtIP.Text
Winsock1.RemotePort = Val(txtPort.Text)

Winsock1.Connect

Do While (Winsock1.State <> sckConnected)
    If Winsock1.State = sckConnecting Then Text2.Text = "connecting"
    DoEvents
Loop
    If Winsock1.State = sckConnected Then Text2.Text = "finish"

End Sub

Private Sub Command3_Click()

Winsock1.Close

Do While (Winsock1.State <> sckClosed)
    If Winsock1.State = sckConnected Then Text2.Text = "disconecting"
    DoEvents
Loop
    If Winsock1.State = sckClosed Then Text2.Text = "finish"

End Sub

Private Sub SendMsg(strMsg As String)

Winsock1.SendData strMsg

End Sub

Private Sub GetMsg(strMsg As String)

MsgFlg = 0
    
Winsock1.SendData strMsg
    
Do While (MsgFlg = 0)
    DoEvents
Loop
    
End Sub

Private Sub Winsock1_DataArrival(ByVal bytesTotal As Long)

Winsock1.GetData MsgBuf, vbString
        
MsgFlg = 1

End Sub





Example 5 Checking the presence of input channel, and displaying
          the input ranges on the screen.



Dim MsgFlg As Integer
Dim MsgBuf As String

Private Sub Command1_Click()
'*******************************************************************************
' 10BASE-T(LAN) SAMPLE PROGRAM NO.5
'*******************************************************************************

deli$ = Chr$(13) & Chr$(10)

MAXCH = 8                                            '8420-51=8,8421-51=16,8422-51=32
Dim ch_data$(32 + 1)

SendMsg ":HEADER OFF" & deli$
SendMsg ":MEMORY:GETREAL" & deli$
                                                      
For ch = 1 To MAXCH
    GetMsg ":MEMORY:AREAL? CH" + Str$(ch) & deli$
    ar$ = MsgBuf
    ch_data$(ch) = "CH" + Str$(ch) + " = " & ar$
Next ch

For ch = 1 To MAXCH
    Text1.SelText = ch_data$(ch) & deli$
Next ch

End Sub

Private Sub Command2_Click()

Winsock1.Protocol = sckTCPProtocol
Winsock1.RemoteHost = txtIP.Text
Winsock1.RemotePort = Val(txtPort.Text)

Winsock1.Connect

Do While (Winsock1.State <> sckConnected)
    If Winsock1.State = sckConnecting Then Text2.Text = "connecting"
    DoEvents
Loop
    If Winsock1.State = sckConnected Then Text2.Text = "finish"

End Sub

Private Sub Command3_Click()

Winsock1.Close

Do While (Winsock1.State <> sckClosed)
    If Winsock1.State = sckConnected Then Text2.Text = "disconecting"
    DoEvents
Loop
    If Winsock1.State = sckClosed Then Text2.Text = "finish"

End Sub

Private Sub SendMsg(strMsg As String)

Winsock1.SendData strMsg

End Sub

Private Sub GetMsg(strMsg As String)

MsgFlg = 0
    
Winsock1.SendData strMsg
    
Do While (MsgFlg = 0)
    DoEvents
Loop
    
End Sub

Private Sub Winsock1_DataArrival(ByVal bytesTotal As Long)

Winsock1.GetData MsgBuf, vbString
        
MsgFlg = 1

End Sub





Example 6 Saving stored data onto drive A



Dim MsgFlg As Integer
Dim MsgBuf As String

Private Sub Command1_Click()
'*******************************************************************************
' 10BASE-T(LAN) SAMPLE PROGRAM NO.6
'*******************************************************************************

deli$ = Chr$(13) & Chr$(10)


na$ = "a:\sample.dat"

SendMsg ":HEADER OFF" & deli$
GetMsg ":MEMORY:MAXPOINT?" & deli$
mx$ = MsgBuf

If (Val(mx$) = 0) Then
Exit Sub
End If

Open na$ For Output As #1
SendMsg ":MEMORY:POINT CH1,0" & deli$
Print #1, Val(mx$)
For i = 1 To Val(mx$)
    GetMsg ":MEMORY:ADATA? 1" & deli$
    ad$ = MsgBuf
Print #1, Val(ad$)
Next

Close #1


End Sub

Private Sub Command2_Click()

Winsock1.Protocol = sckTCPProtocol
Winsock1.RemoteHost = txtIP.Text
Winsock1.RemotePort = Val(txtPort.Text)

Winsock1.Connect

Do While (Winsock1.State <> sckConnected)
    If Winsock1.State = sckConnecting Then Text2.Text = "connecting"
    DoEvents
Loop
    If Winsock1.State = sckConnected Then Text2.Text = "finish"

End Sub

Private Sub Command3_Click()

Winsock1.Close

Do While (Winsock1.State <> sckClosed)
    If Winsock1.State = sckConnected Then Text2.Text = "disconecting"
    DoEvents
Loop
    If Winsock1.State = sckClosed Then Text2.Text = "finish"

End Sub

Private Sub SendMsg(strMsg As String)

Winsock1.SendData strMsg

End Sub

Private Sub GetMsg(strMsg As String)

MsgFlg = 0
    
Winsock1.SendData strMsg
    
Do While (MsgFlg = 0)
    DoEvents
Loop
    
End Sub

Private Sub Winsock1_DataArrival(ByVal bytesTotal As Long)

Winsock1.GetData MsgBuf, vbString
        
MsgFlg = 1

End Sub





Example 7 Reading the data saved in Example 6, and loading it into the unit.



Dim MsgFlg As Integer
Dim MsgBuf As String

Private Sub Command1_Click()
'*******************************************************************************
' 10BASE-T(LAN) SAMPLE PROGRAM NO.7
'*******************************************************************************

deli$ = Chr$(13) & Chr$(10)


na$ = "a:\sample.dat"

SendMsg ":HEADER OFF" & deli$
GetMsg ":MEMORY:PREPARE;*OPC?" & deli$
o$ = MsgBuf

Open na$ For Input As #1
SendMsg ":MEMORY:POINT CH1,0" & deli$
Line Input #1, mx
For i = 1 To mx
    Line Input #1, dt
    SendMsg ":MEMORY:ADATA " & Str$(dt) & deli$
Next

Close #1


End Sub

Private Sub Command2_Click()

Winsock1.Protocol = sckTCPProtocol
Winsock1.RemoteHost = txtIP.Text
Winsock1.RemotePort = Val(txtPort.Text)

Winsock1.Connect

Do While (Winsock1.State <> sckConnected)
    If Winsock1.State = sckConnecting Then Text2.Text = "connecting"
    DoEvents
Loop
    If Winsock1.State = sckConnected Then Text2.Text = "finish"

End Sub

Private Sub Command3_Click()

Winsock1.Close

Do While (Winsock1.State <> sckClosed)
    If Winsock1.State = sckConnected Then Text2.Text = "disconecting"
    DoEvents
Loop
    If Winsock1.State = sckClosed Then Text2.Text = "finish"

End Sub

Private Sub SendMsg(strMsg As String)

Winsock1.SendData strMsg

End Sub

Private Sub GetMsg(strMsg As String)

MsgFlg = 0
    
Winsock1.SendData strMsg
    
Do While (MsgFlg = 0)
    DoEvents
Loop
    
End Sub

Private Sub Winsock1_DataArrival(ByVal bytesTotal As Long)

Winsock1.GetData MsgBuf, vbString
        
MsgFlg = 1

End Sub


Download Driver Pack

How To Update Drivers Manually

After your driver has been downloaded, follow these simple steps to install it.

  • Expand the archive file (if the download file is in zip or rar format).

  • If the expanded file has an .exe extension, double click it and follow the installation instructions.

  • Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.

  • Find the device and model you want to update in the device list.

  • Double-click on it to open the Properties dialog box.

  • From the Properties dialog box, select the Driver tab.

  • Click the Update Driver button, then follow the instructions.

Very important: You must reboot your system to ensure that any driver updates have taken effect.

For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.

server: web4, load: 0.90