Released Note.txt Driver File Contents (KR_M1_Win.zip)

Centragate USB 1.03E Annex A Engineering Package Release 008 for Windows
-----------------------------------------------------------------------------


Centragate USB Annex-A Engineering driver release for Windows
-----------------------------------------------------------------------------
Product				: Centragate USB
OS				: Windows (98/98SE/ME/2K/XP)
Package release version		: CGU 1.03E AnnexA - Package 008
Windows Driver version		: 1.03.0008E-A
Installer Version		: 2.6.11
Control Panel Version		: 4.1.0
Firmware Version		: Y1.9.21 (Annex A)
8051 Runtime Version		: 1.01.0003
Recommended Bootcode version:	: 1.00.0007

REASON FOR RELEASE:
- This release addresses defect VTAen36900.
- Included is an early engineering release ** FOR EVALUATION ONLY ** (no 
  significant stress/WHQL testing has been done with it yet) of the ATM 
  driver. Details on its configuration for use with different protocols
  is included below.

NEW FEATURES:
- Though included since 1.03.0005, since this is the first official DoxBox 
  release since it was implemented, we describe the new "OamDisable" registry 
  string behavior (VTAen36431):
	0x00 = Enable ALL OAM features
	0xFF = Disable ALL OAM features
	0x01 = Disable OAM F4/F5 Reply of CO initiated loopback cells
	0x02 = Disable OAM AIS/RDI Reply of CO initiated loopback cells
	
MRs CORRECTED:
- VTAen36900 - Latest Centragate USB driver for WHQL 
- VTAen36431 - Centragate OAM function request

KNOWN ISSUES:
- ATM driver link speed as reported in "GlobespanVirata Dial-up PPP Connection" 
  status window displays incorrect value: 28.8K on WinXP, 10 Mbps in Win2K 
  (VTAen26570). Rely on speed displayed by "ATM Connection Status" in the 
  "Network Connections" folder instead.

PACKAGE TEST RESULTS:
- Installed/Uninstalled/PPP/Ping/FTP of WAN driver on WinXP.

COMMENTS:

---------------------------------------------
CONFIGURATION FOR ATM DRIVER UNDER WINDOWS XP
---------------------------------------------
Since the Installer does not yet handle all ATM driver's posibilities, manual 
configuration information for operation with all possible protocols under 
Windows XP is included in this section.

I) Installing the Driver:
	1. Plug in the USB device to the PC with the USb cable.
	2. At the Welcome screen click Next. At the License Agreement click Accept.
	3. Select "Choose my settings form a list of choices" and click Next.
	4. Click on "Customize".
	5. Select "ATM Driver" and click Next.
	6. Enter/Select the desired VPI, VCI, Encapsulation information (all this 
	   settings should be provided by your ISP). Select the modulation (leave
	   the "Multimode" default if unsure).
	7. Confirm your choices at the Summary screen by clicking Next (or "Back" 
	   and correct any mistake)
	8. Drivers are installed and you are prompted for reboot. Upon system 
	   restart the drivers should be ready to use.

II) Configuring the System Protocols.

Make sure the device is plugged in and in Data mode (DSL Status application shows
"Data" or network icon in the system tray shows the link is up), then proceed.

A) RFC2364 (also known as "PPPoA" or "PPP Over ATM")

The Installer application creates a PPPoA (RFC2364) dial-up connection over the ATM 
driver programatically during the installation process. Nothing else needs to be 
done to use it. You can access access it by the name "GlobespanVirata Dial-Up PPP 
Connection" icon present in the "Network Connections" panel (or via the shortcut 
in your desktop) and you will only need to enter your username and password (VPI 
and VCI will be already filled up).

As said, this is not needed, but if you want to create the dial-up adapter 
manually, these are the steps:

	1. Open the "Network Connections" Panel and select "Create a New 
	   Connection" From the "Network Tasks" menu on the left side.
	2. Click Next at the Welcome screen.
	3. Select "Connect to the Internet" and click Next.
	4. Select "Setup Manually" and click Next.
	5. Select "Connect using a dialup modem" and click Next.
	6. Select "GlobespanVirata USB ADSL ATM Modem" and click Next.
	7. Enter the ISP name (i.e.: "GlobespanVirata PPPoA")
	8. Enter the phone number in the following format p<vpi>,<vci>
	   Vpi and Vci are values provided by your ISP.
	   For example for Vpi=0, Vci =88 enter the string "p0,88" (without the 
	   quotes). Click Next.
	9. Enter username and password information. Click Next.
	10.Click "Add shortcut to your desktop" (if desired) and click Next.
	11.All done, open the dialer and click "Dial" to connect.

B) RFC2684 (also known as "Ethernet over ATM").

	1. Open the "Network Connections" Panel.
	2. Right Click on the device named "ATM Connection" with a Device Name of
	   "GlobespanVirata USB ADSL ATM Modem" and select Properties.
	3. In the "ATM Connection Properties" window, click Install. 
	4. In the "Select Network Component Type" window select "Protocol" and
	   click Add.
	5. Select "Microsoft Ethernet PVC - RFC 2364" and click OK. The selected 
	   protocol gets added to the items in "ATM Connection Properties". Click 
	   Close.
	6. At the "Network Connections" Panel a new device with the name 
	   "Local Area Connection <n>" (n is a number and depends on how many 
	   Ethernet devices are present in your system) and Device Name "ATM 
	   Emulated LAN" or "Ethernet ATM Miniport" will appear. Right click 
	   it and select Properties.
	7. On the "Local Area Connection <n>" Properties window click "Configure"
	   below the "Ethernet ATM Miniport" adapter.
	8. On the "Ethernet ATM Miniport" Properties window select the Advanced Tab
	9. Select/Enter the desired encapsulation, VPI and VCI (all are provided by
	   your ISP). Click OK.
	10.If you want to configure the device for RFC2516 continue in section C) 
	   below.
	11.DSL device Setup is complete. There is no dial-up for RFC2684, your 
	   connection should be established automatically within a few seconds. 
	   If a DHCP server is present in the network you will be assigned an IP 
	   address automatically, if not your ISP has provided you with an IP 
	   address that you should enter in the "Internet Protocol TCP/IP"  
	   properties pane of the Ethernet ATM Miniport. 

C) RFC2516 (also known as "PPPoE" or "PPP Over Ethernet").
	
	1. Perform steps 1 - 10 from section B) (RFC2684).
	2. Open the "Network Connections" Panel and select "Create a New 
	   Connection" From the "Network Tasks" menu on the left side.
	3. Click Next at the Welcome screen.
	4. Select "Connect to the Internet" and click Next.
	5. Select Setup Manually and click Next.
	6. Select "Connect using a broadband connection that requires a user name 
	   and password". Click Next.
	7. Enter the ISP name (i.e.: GlobespanVirata PPPoE)
	8. Enter username and password information. Click Next.
	9. Click "Add shortcut to your desktop" (if desired) and click Next.
	10.All done, open the dialer and click "Connect".


NOTES:
- It is highly unlikely that you will be operating in a network that accepts several 
  different protocols over different VCs. However, we have tested the following 
  simultaneous connections successfully:
	a. RFC 2684 (VPI=0, VCI=35) and RFC 2364 (VPI = 0, VCI = 88).
	b. RFC 2516 (VPI=0, VCI=36) and RFC 2364 (VPI = 0, VCI = 88).
- As said above, this is a preview "engineering release" of our ATM driver solution. 
  This ATM DRIVER NOT READY FOR PRODUCTION at this time No stress or WHQL testing has 
  been performed on it yet.

Download Driver Pack

How To Update Drivers Manually

After your driver has been downloaded, follow these simple steps to install it.

  • Expand the archive file (if the download file is in zip or rar format).

  • If the expanded file has an .exe extension, double click it and follow the installation instructions.

  • Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.

  • Find the device and model you want to update in the device list.

  • Double-click on it to open the Properties dialog box.

  • From the Properties dialog box, select the Driver tab.

  • Click the Update Driver button, then follow the instructions.

Very important: You must reboot your system to ensure that any driver updates have taken effect.

For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.

server: web5, load: 1.69