TRIPPLITE-MIB DEFINITIONS ::= BEGIN IMPORTS DisplayString, TruthValue, TimeStamp, TimeInterval, DateAndTime, AutonomousType, VariablePointer, RowStatus FROM SNMPv2-TC OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Gauge32, Integer32, enterprises, IpAddress FROM SNMPv2-SMI PositiveInteger, NonNegativeInteger FROM UPS-MIB; tripplite MODULE-IDENTITY LAST-UPDATED "200904270000Z" ORGANIZATION "Tripplite Inc" CONTACT-INFO "Mike Delgroso Tripplite, Inc. 1111 W. 35th St. Chicago, IL 60609" DESCRIPTION "This MIB module defines MIB objects which provide mechanisms for remote management capabilities of Tripplite PowerAlert and related software." REVISION "200904270000Z" DESCRIPTION "Added tlUpsAlarmOutputCurrentChanged well known alarm trap" REVISION "200810140000Z" DESCRIPTION "Added tlUpsOutletCurrentTable and tlUpsOutletPowerTable to publish load-specific variables" REVISION "200809250000Z" DESCRIPTION "Added tlUpsOutletGroupTable." REVISION "200802010000Z" DESCRIPTION "V1 trap decode support." REVISION "200711300000Z" DESCRIPTION "Changed tlUpsAlarmTime to int to match implementation, same for tlUpsAlarmDescr to string" REVISION "200711290000Z" DESCRIPTION "Changed tlUpsConfigBattReplDate and tlUpsTestDate from integer back to string." REVISION "200708260000Z" DESCRIPTION "Migrated changes from 12.04.0034, which included Load -> Outlet." REVISION "200702280000Z" DESCRIPTION "Renamed Load to Outlet. Cleaned up MIB compilation errors." REVISION "200612120000Z" DESCRIPTION "Changed tlUpsConfigBattReplDate and tlUpsTestDate from string to integer." REVISION "200612060000Z" DESCRIPTION "Implement tlUpsOutletTable." REVISION "200606200000Z" DESCRIPTION "Implemented tlUpsAlarmTable to coincide with upsAlarmTable, but all for additional variables." REVISION "200507130000Z" DESCRIPTION "Modifications to bring MIB into compliance. Changed OID name from upsLoadNumLoads to tlUpsLoadNumLoads." REVISION "200305160000Z" DESCRIPTION "Initial release, for PowerAlert Version 12." ::= { enterprises 850 } -------------------------------------------------------------------------- -- Enumerations -------------------------------------------------------------------------- tlEnumerations OBJECT IDENTIFIER ::= { tripplite 2 } tlOperatingSystems OBJECT IDENTIFIER ::= { tlEnumerations 1 } hpux9 OBJECT IDENTIFIER ::= { tlOperatingSystems 1 } sunos4 OBJECT IDENTIFIER ::= { tlOperatingSystems 2 } solaris OBJECT IDENTIFIER ::= { tlOperatingSystems 3 } osf OBJECT IDENTIFIER ::= { tlOperatingSystems 4 } ultrix OBJECT IDENTIFIER ::= { tlOperatingSystems 5 } hpux10 OBJECT IDENTIFIER ::= { tlOperatingSystems 6 } netbsd1 OBJECT IDENTIFIER ::= { tlOperatingSystems 7 } freebsd OBJECT IDENTIFIER ::= { tlOperatingSystems 8 } irix OBJECT IDENTIFIER ::= { tlOperatingSystems 9 } linux OBJECT IDENTIFIER ::= { tlOperatingSystems 10 } bsdi OBJECT IDENTIFIER ::= { tlOperatingSystems 11 } openbsd OBJECT IDENTIFIER ::= { tlOperatingSystems 12 } win32 OBJECT IDENTIFIER ::= { tlOperatingSystems 13 } hpux11 OBJECT IDENTIFIER ::= { tlOperatingSystems 14 } win9x OBJECT IDENTIFIER ::= { tlOperatingSystems 50 } winnt OBJECT IDENTIFIER ::= { tlOperatingSystems 51 } solspark OBJECT IDENTIFIER ::= { tlOperatingSystems 52 } solintel OBJECT IDENTIFIER ::= { tlOperatingSystems 53 } aix OBJECT IDENTIFIER ::= { tlOperatingSystems 54 } sco OBJECT IDENTIFIER ::= { tlOperatingSystems 55 } osx OBJECT IDENTIFIER ::= { tlOperatingSystems 56 } unknown OBJECT IDENTIFIER ::= { tlOperatingSystems 255 } -------------------------------------------------------------------------- -- UPS Device -------------------------------------------------------------------------- tlUPS OBJECT IDENTIFIER ::= { tripplite 100 } tlUpsObjects OBJECT IDENTIFIER ::= { tlUPS 1 } tlUpsIdent OBJECT IDENTIFIER ::= { tlUpsObjects 1 } tlUpsIdentUpsSoftwareChecksum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A checksum for the UPS fostware." ::= { tlUpsIdent 1 } tlUpsIdentSerialNum OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Serial number for the UPS." ::= { tlUpsIdent 2 } tlUpsIdentID OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "A user-supplied ID for the UPS." ::= { tlUpsIdent 3 } tlUpsSnmpCardSerialNum OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Serial number for the UPS." ::= { tlUpsIdent 4 } tlUpsBattery OBJECT IDENTIFIER ::= { tlUpsObjects 2 } tlUpsBatteryAge OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The age of the battery, in the format YYYYMMDD. This is equal to the current date minus tlConfigBattReplDate." ::= { tlUpsBattery 1 } tlUpsTemperatureF OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The temperature of the battery, in Farenheight degrees. This is calculated from upsBatteryTemperature, which is in Celsius degrees." ::= { tlUpsBattery 2 } tlUpsInput OBJECT IDENTIFIER ::= { tlUpsObjects 3 } tlUpsOutput OBJECT IDENTIFIER ::= { tlUpsObjects 4 } tlUpsBypass OBJECT IDENTIFIER ::= { tlUpsObjects 5 } tlUpsAlarm OBJECT IDENTIFIER ::= { tlUpsObjects 6 } tlUpsAlarmsPresent OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The present number of active alarm conditions." ::= { tlUpsAlarm 1 } tlUpsAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF TlUpsAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of alarm table entries." ::= { tlUpsAlarm 2 } tlUpsAlarmEntry OBJECT-TYPE SYNTAX TlUpsAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing information applicable to a particular alarm." INDEX { tlUpsAlarmId } ::= { tlUpsAlarmTable 1 } TlUpsAlarmEntry ::= SEQUENCE { tlUpsAlarmId PositiveInteger, tlUpsAlarmDescr AutonomousType, tlUpsAlarmTime TimeStamp, tlUpsAlarmDetail DisplayString, tlUpsAlarmDeviceId PositiveInteger, tlUpsAlarmDeviceName DisplayString, tlUpsAlarmLocation DisplayString, tlUpsAlarmGroup INTEGER, tlUpsAlarmIp IpAddress, tlUpsAlarmMac DisplayString } tlUpsAlarmId OBJECT-TYPE SYNTAX PositiveInteger MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier for an alarm condition." ::= { tlUpsAlarmEntry 1 } tlUpsAlarmDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A description of the alarm condition." ::= { tlUpsAlarmEntry 2 } tlUpsAlarmTime OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime when the alarm condition was detected." ::= { tlUpsAlarmEntry 3 } tlUpsAlarmDetail OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A textual description of the alarm condition." ::= { tlUpsAlarmEntry 4 } tlUpsAlarmDeviceId OBJECT-TYPE SYNTAX PositiveInteger MAX-ACCESS read-only STATUS current DESCRIPTION "A numeric identifier for the device on which the alarm is active." ::= { tlUpsAlarmEntry 5 } tlUpsAlarmDeviceName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A string identifier for the device on which the alarm is active." ::= { tlUpsAlarmEntry 6 } tlUpsAlarmLocation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The location of the device on which the alarm is active." ::= { tlUpsAlarmEntry 7 } tlUpsAlarmGroup OBJECT-TYPE SYNTAX INTEGER { critical(1), warning(2), info(3), status(4), offline(5), custom(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The category/group of this alarm." ::= { tlUpsAlarmEntry 8 } tlUpsAlarmIp OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The originating IP address associated with this alarm." ::= { tlUpsAlarmEntry 9 } tlUpsAlarmMac OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The originating mac address associated with this alarm." ::= { tlUpsAlarmEntry 10 } tlUpsWellKnownAlarms OBJECT IDENTIFIER ::= { tlUpsAlarm 3 } tlUpsAlarmPrimaryPowerOutage OBJECT-IDENTITY STATUS current DESCRIPTION "The primary power source is not present." ::= { tlUpsWellKnownAlarms 1 } tlUpsAlarmSecondaryPowerOutage OBJECT-IDENTITY STATUS current DESCRIPTION "The secondary power source is not present." ::= { tlUpsWellKnownAlarms 2 } tlUpsAlarmLoadLevelAboveThreshold OBJECT-IDENTITY STATUS current DESCRIPTION "The load level is above the designated threshold." ::= { tlUpsWellKnownAlarms 3 } tlUpsAlarmOutputCurrentChanged OBJECT-IDENTITY STATUS current DESCRIPTION "The output current changed from its last known value." ::= { tlUpsWellKnownAlarms 4 } tlUpsAlarmDevName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The name of the device, tlDevName, corresponding to the device that is associated with this alarm." ::= { tlUpsAlarm 7 } tlUpsAlarmDevLocation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The location of the device, tlDevLocation, corresponding to the device that is associated with this alarm." ::= { tlUpsAlarm 8 } tlUpsAlarmCategory OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The category, tlDevEvtCategory, of this alarm." ::= { tlUpsAlarm 9 } tlUpsTest OBJECT IDENTIFIER ::= { tlUpsObjects 7 } tlUpsTestDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The date of the last self-test run on the ups, in the format YYYYMMDD." ::= { tlUpsTest 1 } tlUpsTestResultsDetail OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Result of the last self-test run on the ups." ::= { tlUpsTest 2 } tlUpsControl OBJECT IDENTIFIER ::= { tlUpsObjects 8 } tlUpsWatchdogSupported OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether or not this UPS supports a watchdog reboot." ::= { tlUpsControl 1 } tlUpsWatchdogSecsBeforeReboot OBJECT-TYPE SYNTAX NonNegativeInteger MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum number of seconds that can expire between polls that the engine makes to the UPS for data. If this time runs out, then the UPS will cycle its outputs. Set this to zero to turns disable this feature." ::= { tlUpsControl 2 } tlUpsWellKnownControls OBJECT IDENTIFIER ::= { tlUpsControl 3 } tlUpsControlSelfTest OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Set to TRUE to initiate Self Test" ::= { tlUpsWellKnownControls 1 } tlUpsControlRamp OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Set to TRUE to initiate Ramp" ::= { tlUpsWellKnownControls 2 } tlUpsControlShed OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Set to TRUE to initiate Shed" ::= { tlUpsWellKnownControls 3 } tlUpsControlUpsOn OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Set to TRUE to turn UPS on" ::= { tlUpsWellKnownControls 4 } tlUpsControlUpsOff OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Set to TRUE to turn UPS off" ::= { tlUpsWellKnownControls 5 } tlUpsConfig OBJECT IDENTIFIER ::= { tlUpsObjects 9 } tlUpsConfigBattReplDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The date on which the battery was last replaced, in the format YYYYMMDD." ::= { tlUpsConfig 1 } tlUpsConfigTftpGetAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address of the TFTP server you wish to acquire a config ini file from, non persistent, 0.0.0.0 when empty" ::= { tlUpsConfig 2 } tlUpsConfigTftpGetAcction OBJECT-TYPE SYNTAX INTEGER { get(1), getting(2), idle(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "setting this entry to get(1) will start a down load from the specified address, during the download this entry will read getting(2), when finished, the card will reboot to the new ini supplied parms. At all other times this entry will read idle(3)" ::= { tlUpsConfig 3 } tlUpsOutlet OBJECT IDENTIFIER ::= { tlUpsObjects 10 } tlUpsOutletNumOutlets OBJECT-TYPE SYNTAX NonNegativeInteger MAX-ACCESS read-only STATUS current DESCRIPTION "The number of available Outlets in this device." ::= { tlUpsOutlet 1 } tlUpsOutletTable OBJECT-TYPE SYNTAX SEQUENCE OF TlUpsOutletEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of all device Outlets for all devices." ::= { tlUpsOutlet 2 } tlUpsOutletEntry OBJECT-TYPE SYNTAX TlUpsOutletEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing Outlet information applicable to a particular device managed by this agent." INDEX { tlUpsOutletIndex } ::= { tlUpsOutletTable 1 } TlUpsOutletEntry ::= SEQUENCE { tlUpsOutletIndex PositiveInteger, tlUpsOutletState INTEGER, tlUpsOutletType Integer32, tlUpsOutletControl INTEGER, tlUpsOutletName DisplayString, tlUpsOutletRampAction INTEGER, tlUpsOutletRampDataType INTEGER, tlUpsOutletRampData Integer32, tlUpsOutletShedAction INTEGER, tlUpsOutletShedDataType INTEGER, tlUpsOutletShedData Integer32, tlUpsOutletGroupNdx Integer32 } tlUpsOutletIndex OBJECT-TYPE SYNTAX PositiveInteger MAX-ACCESS read-only STATUS current DESCRIPTION "This is the index number of this Outlet for the device indicated by tlDeviceIndex." ::= { tlUpsOutletEntry 1 } tlUpsOutletState OBJECT-TYPE SYNTAX INTEGER { unknown(0), off(1), on(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of the Outlet." ::= { tlUpsOutletEntry 2 } tlUpsOutletType OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a bit field that indicates the type of this Outlet. Bit Display 0 Battery Protected 1 Controllable 2 3 4 5 6 7 8 9 10 11 12 13 14 15 " ::= { tlUpsOutletEntry 3 } tlUpsOutletControl OBJECT-TYPE SYNTAX INTEGER { turnOff(1), turnOn(2), cycle(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the state of the Outlet." ::= { tlUpsOutletEntry 4 } tlUpsOutletName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "A string identifying the devices attached to the output(s) of the device." ::= { tlUpsOutletEntry 5 } tlUpsOutletRampAction OBJECT-TYPE SYNTAX INTEGER { remainOff(0), turnOnAfterDelay(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The ramp action to take on the Outlet." ::= { tlUpsOutletEntry 6 } tlUpsOutletRampDataType OBJECT-TYPE SYNTAX INTEGER { delayInSeconds(0) } MAX-ACCESS read-write STATUS current DESCRIPTION "The type of data associated with ramp action." ::= { tlUpsOutletEntry 7 } tlUpsOutletRampData OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The data value associated with type of ramp data." ::= { tlUpsOutletEntry 8 } tlUpsOutletShedAction OBJECT-TYPE SYNTAX INTEGER { remainOn(0), turnOffAfterDelay(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The shed action to take on the Outlet." ::= { tlUpsOutletEntry 9 } tlUpsOutletShedDataType OBJECT-TYPE SYNTAX INTEGER { delayInSeconds(0) } MAX-ACCESS read-write STATUS current DESCRIPTION "The type of data associated with shed action." ::= { tlUpsOutletEntry 10 } tlUpsOutletShedData OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The data value associated with type of shed data." ::= { tlUpsOutletEntry 11 } tlUpsOutletGroupNdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "tlUpsOutletGroupIndex of corresponding outlet group, or 0 if ungrouped." ::= { tlUpsOutletEntry 12 } tlUpsOutletCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF TlUpsOutletCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of load currents." ::= { tlUpsOutlet 3 } tlUpsOutletCurrentEntry OBJECT-TYPE SYNTAX TlUpsOutletCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing Outlet current information applicable to a particular device managed by this agent." INDEX { tlUpsOutletCurrentIndex } ::= { tlUpsOutletCurrentTable 1 } TlUpsOutletCurrentEntry ::= SEQUENCE { tlUpsOutletCurrentIndex PositiveInteger, tlUpsOutletCurrentValue PositiveInteger } tlUpsOutletCurrentIndex OBJECT-TYPE SYNTAX PositiveInteger MAX-ACCESS read-only STATUS current DESCRIPTION "This is the index number of this Outlet." ::= { tlUpsOutletCurrentEntry 1 } tlUpsOutletCurrentValue OBJECT-TYPE SYNTAX PositiveInteger MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this outlet's current, represented as 0.1A" ::= { tlUpsOutletCurrentEntry 2 } tlUpsOutletPowerTable OBJECT-TYPE SYNTAX SEQUENCE OF TlUpsOutletPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of load power." ::= { tlUpsOutlet 4 } tlUpsOutletPowerEntry OBJECT-TYPE SYNTAX TlUpsOutletPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing Outlet power information applicable to a particular device managed by this agent." INDEX { tlUpsOutletPowerIndex } ::= { tlUpsOutletPowerTable 1 } TlUpsOutletPowerEntry ::= SEQUENCE { tlUpsOutletPowerIndex PositiveInteger, tlUpsOutletPowerValue PositiveInteger } tlUpsOutletPowerIndex OBJECT-TYPE SYNTAX PositiveInteger MAX-ACCESS read-only STATUS current DESCRIPTION "This is the index number of this Outlet." ::= { tlUpsOutletPowerEntry 1 } tlUpsOutletPowerValue OBJECT-TYPE SYNTAX PositiveInteger MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this outlet's power in watts." ::= { tlUpsOutletPowerEntry 2 } tlUpsOutletGroup OBJECT IDENTIFIER ::= { tlUpsObjects 11 } tlUpsOutletNumOutletGroups OBJECT-TYPE SYNTAX NonNegativeInteger MAX-ACCESS read-only STATUS current DESCRIPTION "The number of available Outlet Groups in this device." ::= { tlUpsOutletGroup 1 } tlUpsOutletGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF TlUpsOutletGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of device outlet group entries. The number of entries is given by the value of tlUpsOutletNumOutletGroups." ::= { tlUpsOutletGroup 2 } tlUpsOutletGroupEntry OBJECT-TYPE SYNTAX TlUpsOutletGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing outlet group information applicable to a particular device managed by this agent" INDEX { tlUpsOutletGroupIndex } ::= { tlUpsOutletGroupTable 1 } TlUpsOutletGroupEntry ::= SEQUENCE { tlUpsOutletGroupIndex PositiveInteger, tlUpsOutletGroupUnused Integer32, tlUpsOutletGroupName DisplayString, tlUpsOutletGroupDesc DisplayString, tlUpsOutletGroupState INTEGER, tlUpsOutletGroupControl INTEGER } tlUpsOutletGroupIndex OBJECT-TYPE SYNTAX PositiveInteger MAX-ACCESS read-only STATUS current DESCRIPTION "This is the index number of this load group for the device." ::= { tlUpsOutletGroupEntry 1 } tlUpsOutletGroupUnused OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Unused placeholder" ::= { tlUpsOutletGroupEntry 2 } tlUpsOutletGroupName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The name of this outlet group." ::= { tlUpsOutletGroupEntry 3 } tlUpsOutletGroupDesc OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "A description for this outlet group." ::= { tlUpsOutletGroupEntry 4 } tlUpsOutletGroupState OBJECT-TYPE SYNTAX INTEGER { unknown(0), off(1), on(2), mixed(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of the outlet group." ::= { tlUpsOutletGroupEntry 5 } tlUpsOutletGroupControl OBJECT-TYPE SYNTAX INTEGER { turnOff(1), turnOn(2), cycle(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the state of every outlet associated with the group." ::= { tlUpsOutletGroupEntry 6 } tlUpsTraps OBJECT IDENTIFIER ::= { tlUPS 2 } tlUpsTrapAlarmEntryAddedV1 TRAP-TYPE ENTERPRISE tlUpsTraps VARIABLES { tlUpsAlarmId, tlUpsAlarmDescr, tlUpsAlarmDetail, tlUpsAlarmDeviceId, tlUpsAlarmDeviceName, tlUpsAlarmLocation, tlUpsAlarmGroup } DESCRIPTION "This trap is sent each time an alarm is inserted into to the alarm table." --#SUMMARY "UPS Alarm: %s - %s." --#ARGUMENTS {6, 2} --#SEVERITY WARNING ::= 3 tlUpsTrapAlarmEntryAdded NOTIFICATION-TYPE OBJECTS { tlUpsAlarmId, tlUpsAlarmDescr, tlUpsAlarmDetail, tlUpsAlarmDeviceId, tlUpsAlarmDeviceName, tlUpsAlarmLocation, tlUpsAlarmGroup } STATUS current DESCRIPTION "This trap is sent each time an alarm is inserted into to the alarm table." --#SUMMARY "UPS Alarm: %s - %s." --#ARGUMENTS {6, 2} --#SEVERITY WARNING ::= { tlUpsTraps 3 } tlUpsTrapAlarmEntryRemovedV1 TRAP-TYPE ENTERPRISE tlUpsTraps VARIABLES { tlUpsAlarmId, tlUpsAlarmDescr, tlUpsAlarmDetail, tlUpsAlarmDeviceId, tlUpsAlarmDeviceName, tlUpsAlarmLocation, tlUpsAlarmGroup } DESCRIPTION "This trap is sent each time an alarm is removed from the alarm table." --#SUMMARY "UPS Alarm: %s - %s." --#ARGUMENTS {6, 2} --#SEVERITY WARNING ::= 4 tlUpsTrapAlarmEntryRemoved NOTIFICATION-TYPE OBJECTS { tlUpsAlarmId, tlUpsAlarmDescr, tlUpsAlarmDetail, tlUpsAlarmDeviceId, tlUpsAlarmDeviceName, tlUpsAlarmLocation, tlUpsAlarmGroup } STATUS current DESCRIPTION "This trap is sent each time an alarm is removed from the alarm table." --#SUMMARY "UPS Alarm: %s - %s." --#ARGUMENTS {6, 2} --#SEVERITY WARNING ::= { tlUpsTraps 4 } -------------------------------------------------------------------------- -- EnviroSense Device -------------------------------------------------------------------------- tlEnviroSense OBJECT IDENTIFIER ::= { tripplite 101 } tlEnvEnvironment OBJECT IDENTIFIER ::= { tlEnviroSense 1 } tlEnvTemperatureData OBJECT IDENTIFIER ::= { tlEnvEnvironment 1 } tlEnvTemperatureC OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The ambient temperature (C)." ::= { tlEnvTemperatureData 1 } tlEnvTemperatureF OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The ambient temperature (F)." ::= { tlEnvTemperatureData 2 } tlEnvTemperatureLowLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The lower alarm limit for ambient temperature (F)." ::= { tlEnvTemperatureData 3 } tlEnvTemperatureHighLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The upper alarm limit for ambient temperature (F)." ::= { tlEnvTemperatureData 4 } tlEnvTemperatureInAlarm OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether or not temperature is in alarm." ::= { tlEnvTemperatureData 5 } tlEnvHumidityData OBJECT IDENTIFIER ::= { tlEnvEnvironment 2 } tlEnvHumidity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The ambient humidity (%)." ::= { tlEnvHumidityData 1 } tlEnvHumidityLowLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The lower alarm limit for ambient humidity (%)." ::= { tlEnvHumidityData 2 } tlEnvHumidityHighLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The upper alarm limit for ambient humidity (%)." ::= { tlEnvHumidityData 3 } tlEnvHumidityInAlarm OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether or not humidity is in alarm." ::= { tlEnvHumidityData 4 } tlEnvContacts OBJECT IDENTIFIER ::= { tlEnviroSense 2 } tlEnvContactTable OBJECT-TYPE SYNTAX SEQUENCE OF TlEnvContactEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of contacts." ::= { tlEnvContacts 1 } tlEnvContactEntry OBJECT-TYPE SYNTAX TlEnvContactEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing information applicable to a particular contact." INDEX { tlEnvContactIndex } ::= { tlEnvContactTable 1 } TlEnvContactEntry ::= SEQUENCE { tlEnvContactIndex PositiveInteger, tlEnvContactName DisplayString, tlEnvContactStatus INTEGER, tlEnvContactConfig INTEGER } tlEnvContactIndex OBJECT-TYPE SYNTAX PositiveInteger MAX-ACCESS read-only STATUS current DESCRIPTION "The table row index for the contact." ::= { tlEnvContactEntry 1 } tlEnvContactName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The name or description of the contact." ::= { tlEnvContactEntry 2 } tlEnvContactStatus OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current status of the contact." ::= { tlEnvContactEntry 3 } tlEnvContactConfig OBJECT-TYPE SYNTAX INTEGER { normallyOpen(0), normallyClosed(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The configuration of the contact." ::= { tlEnvContactEntry 4 } -------------------------------------------------------------------------- -- KVM over IP Device -------------------------------------------------------------------------- -- this is a 3rd party MIB structure located at { tripplite 102 } -------------------------------------------------------------------------- -- Conformance definitions -------------------------------------------------------------------------- tlConformance OBJECT IDENTIFIER ::= { tripplite 20 } tlCompliances OBJECT IDENTIFIER ::= { tlConformance 1 } tlGroups OBJECT IDENTIFIER ::= { tlConformance 2 } tlSubsetGroups OBJECT IDENTIFIER ::= { tlGroups 1 } tlBasicGroups OBJECT IDENTIFIER ::= { tlGroups 2 } tlFullGroups OBJECT IDENTIFIER ::= { tlGroups 3 } tlV11Groups OBJECT IDENTIFIER ::= { tlGroups 4 } tlDeprecatedV11Group OBJECT-GROUP OBJECTS { upsTrapCode, upsTrapDescription } STATUS obsolete DESCRIPTION "The tlDeprecatedV11Group defines objects which were used by Sinetica SNMP cards on Tripplite UPSs and PowerAlert version 11. These objects are currently only used when tlEngineLegacySNMPSupport == true." ::= { tlV11Groups 1 } tlDeprecatedV11NotificationsGroup NOTIFICATION-GROUP NOTIFICATIONS { tlV11upsCritical, tlV11upsWarning, tlV11upsInformation, tlV11upsAlarmCleared, tlV11upsAgentStarted, tlV11upsAgentStopped } STATUS obsolete DESCRIPTION "The tlDeprecatedV11NotificationsGroup defines PowerAlert version 11 notifications. These notifications are being deprecated, but may still be used when tlEngineLegacySNMPSupport = true." ::= { tlV11Groups 2 } tlObsoleteV11Group OBJECT-GROUP OBJECTS { upsReceptaclesNumReceptacles, upsReceptacleIndex, upsReceptacleType, upsReceptacleStatus, upsReceptacleControl, upsEnvTemperature, upsEnvHumidity, upsContactIndex, upsContactName, upsContactStatus, upsContactConfig } STATUS obsolete DESCRIPTION "The tlObsoleteV11Group defines objects which were used by Sinetica SNMP cards on Tripplite UPSs. Most of these objects are obsolete." ::= { tlV11Groups 3 } -- tlUpsCompliances OBJECT IDENTIFIER ::= { tlCompliances 1 } -- -- tlUpsSubsetCompliance MODULE-COMPLIANCE -- STATUS current -- DESCRIPTION -- "Description" -- MODULE == this module -- MANDATORY-GROUPS { -- groups} -- -- OBJECT tlUpsOBJECT1 -- SYNTAX INTEGER { -- enum1(1), -- enum2(2) -- } -- DESCRIPTION -- "Description" -- -- OBJECT tlUpsOBJECT2 -- DESCRIPTION -- "Description" -- -- OBJECT tlUpsOBJECT3 -- MIN-ACCESS read-only -- DESCRIPTION -- "Description" -- ::= { tlUpsCompliances 1 } -- -- tlUpsBasicCompliance MODULE-COMPLIANCE -- ... -- ::= { tlUpsCompliances 2 } -- -- tlUpsFullCompliance MODULE-COMPLIANCE -- ... -- ::= { tlUpsCompliances 3 } -- -- units of conformance -- -- summary at a glance: -- subset basic full --tlUpsIdentUPSSoftwareChecksum x --tlUpsIdentSerialNum x --tlUpsIdentID x -- --tlUpsBatteryAge x --tlUpsBatteryTemperatureF x -- --tlUpsAlarm -- --tlUpsTestDate x -- --tlUpsWatchdogSupported x --tlUpsWatchdogSecsBeforeReboot x -- --tlUpsConfigBattReplDate x -- --tlUpsLoadNumLoads x -- --tlUpsNotificationCode x --tlUpsNotificationDescription x -- --tlUpsCritical x --tlUpsWarning x --tlUpsInformation x --tlUpsAlarmCleared x --tlUpsAgentStarted x --tlUpsAgentStopped x -- --tlUpsSubsetGroups OBJECT IDENTIFIER ::= { tlSubsetGroups 100 } -- --tlUpsBasicGroups OBJECT IDENTIFIER ::= { tlBasicGroups 100 } tlUpsFullGroups OBJECT IDENTIFIER ::= { tlFullGroups 100 } tlUpsFullIdentGroup OBJECT-GROUP OBJECTS { tlUpsIdentUpsSoftwareChecksum, tlUpsIdentSerialNum, tlUpsIdentID } STATUS current DESCRIPTION "The tlUpsFullIdentGroup defines objects which are common to the Ident group of fully compliant Tripplite UPS's" ::= { tlUpsFullGroups 1 } tlUpsFullBatteryGroup OBJECT-GROUP OBJECTS { tlUpsBatteryAge, tlUpsTemperatureF } STATUS current DESCRIPTION "The tlUpsFullBatteryGroup defines objects which are common to the Battery group of fully compliant Tripplite UPS's" ::= { tlUpsFullGroups 2 } tlUpsFullAlarmGroup OBJECT IDENTIFIER ::= { tlUpsFullGroups 6 } tlUpsFullAlarmObjsGroup OBJECT-GROUP OBJECTS { tlUpsAlarmDevName, tlUpsAlarmDevLocation, tlUpsAlarmCategory } STATUS current DESCRIPTION "The tlUpsFullAlarmObjsGroup defines objects which are common to the Alarm group of fully compliant Tripplite UPS's" ::= { tlUpsFullAlarmGroup 1 } --tlUpsFullAlarmsGroup NOTIFICATION-GROUP -- NOTIFICATIONS { } -- STATUS current -- DESCRIPTION -- "The tlUpsFullAlarmGroup defines notifications which are -- common to the Alarm group of fully compliant Tripplite UPS's" -- ::= { tlUpsFullAlarmGroup 2 } tlUpsFullTestGroup OBJECT-GROUP OBJECTS { tlUpsTestDate, tlUpsTestResultsDetail } STATUS current DESCRIPTION "The tlUpsFullTestGroup defines objects which are common to the Test group of fully compliant Tripplite UPS's" ::= { tlUpsFullGroups 7 } tlUpsFullControlGroup OBJECT-GROUP OBJECTS { tlUpsWatchdogSupported, tlUpsWatchdogSecsBeforeReboot } STATUS current DESCRIPTION "The tlUpsFullControlGroup defines objects which are common to the Control group of fully compliant Tripplite UPS's" ::= { tlUpsFullGroups 8 } tlUpsFullConfigGroup OBJECT-GROUP OBJECTS { tlUpsConfigBattReplDate } STATUS current DESCRIPTION "The tlUpsFullConfigGroup defines objects which are common to the Config group of fully compliant Tripplite UPS's" ::= { tlUpsFullGroups 9 } tlUpsFullOutletGroup OBJECT-GROUP OBJECTS { tlUpsOutletNumOutlets } STATUS current DESCRIPTION "The tlUpsFullOutletGroup defines objects which are common to the Outlet group of fully compliant Tripplite UPS's" ::= { tlUpsFullGroups 10 } -------------------------------------------------------------------------- -- Legacy (PowerAlert version 11) objects -- -- These objects have been published in previous Tripplite MIBs and are -- no longer supported, except where otherwise indicated. -------------------------------------------------------------------------- trippUPS OBJECT IDENTIFIER ::= { tripplite 1 } trippUpsReceptacles OBJECT IDENTIFIER ::= { trippUPS 1 } upsReceptaclesNumReceptacles OBJECT-TYPE SYNTAX NonNegativeInteger MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The number of available receptacles in this device. This variable indicates the number of rows in the receptacle table." ::= { trippUpsReceptacles 1 } upsReceptacleTable OBJECT-TYPE SYNTAX SEQUENCE OF UpsReceptacleEntry MAX-ACCESS not-accessible STATUS obsolete DESCRIPTION "A list of receptacle table entries. The number of entries is given by the value of upsReceptaclesNumReceptacles." ::= { trippUpsReceptacles 2 } upsReceptacleEntry OBJECT-TYPE SYNTAX UpsReceptacleEntry MAX-ACCESS not-accessible STATUS obsolete DESCRIPTION "An entry containing information applicable to a particular receptacle." INDEX { upsReceptacleIndex } ::= { upsReceptacleTable 1 } UpsReceptacleEntry ::= SEQUENCE { upsReceptacleIndex PositiveInteger, upsReceptacleType INTEGER, upsReceptacleStatus INTEGER, upsReceptacleControl INTEGER } upsReceptacleIndex OBJECT-TYPE SYNTAX PositiveInteger MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The receptacle identifier." ::= { upsReceptacleEntry 1 } upsReceptacleType OBJECT-TYPE SYNTAX INTEGER { surgeOnly(1), batteryProtected(2), controllableBatteryProtected(3) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The type of receptacle." ::= { upsReceptacleEntry 2 } upsReceptacleStatus OBJECT-TYPE SYNTAX INTEGER { on(1), off(2), unknown(3) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of receptacle." ::= { upsReceptacleEntry 3 } upsReceptacleControl OBJECT-TYPE SYNTAX INTEGER { on(1), off(2), cycle(3) } MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Setting this object to 'on' will turn on the receptacle. Setting this object to 'off' will turn off the receptacle. Setting this object to 'cycle' will turn off and then turn on the receptacle. This action will only take place if the receptacle is controllable (upsReceptacleType = controllableBatteryProtected(3))." ::= { upsReceptacleEntry 4 } trippUpsTrapInfo OBJECT IDENTIFIER ::= { trippUPS 2 } upsTrapCode OBJECT-TYPE SYNTAX INTEGER (0..2147483647) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "A numeric code identifiying the condition that caused the trap to be sent. If the trap number is 104 (upsAgentStarted) or 105 (upsAgentStopped), this code will indicate whether the SNMP agent is software (1) or hardware (2)." ::= { trippUpsTrapInfo 1 } upsTrapDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The description of the trap." ::= { trippUpsTrapInfo 2 } trippUpsEnvironment OBJECT IDENTIFIER ::= { trippUPS 3 } upsEnvTemperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The ambient temperature of the EnviroSense unit (1/10 Deg C)." ::= { trippUpsEnvironment 1 } upsEnvHumidity OBJECT-TYPE SYNTAX INTEGER (0..100) MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The ambient humidity of the EnviroSense unit (% Humidity)." ::= { trippUpsEnvironment 2 } trippUpsContacts OBJECT IDENTIFIER ::= { trippUPS 4 } upsContactTable OBJECT-TYPE SYNTAX SEQUENCE OF UpsContactEntry MAX-ACCESS not-accessible STATUS obsolete DESCRIPTION "A table of contacts attached to the EnviroSense unit." ::= { trippUpsContacts 1 } upsContactEntry OBJECT-TYPE SYNTAX UpsContactEntry MAX-ACCESS not-accessible STATUS obsolete DESCRIPTION "An entry containing information applicable to a particular contact." INDEX { upsContactIndex } ::= { upsContactTable 1 } UpsContactEntry ::= SEQUENCE { upsContactIndex PositiveInteger, upsContactName DisplayString, upsContactStatus INTEGER, upsContactConfig INTEGER } upsContactIndex OBJECT-TYPE SYNTAX PositiveInteger MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The contact identifier." ::= { upsContactEntry 1 } upsContactName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) MAX-ACCESS read-write STATUS obsolete DESCRIPTION "The contact name." ::= { upsContactEntry 2 } upsContactStatus OBJECT-TYPE SYNTAX INTEGER { unknown(0), normal(1), alarm(2) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The current status of the contact." ::= { upsContactEntry 3 } upsContactConfig OBJECT-TYPE SYNTAX INTEGER { normallyClosed(0), normallyOpen(1) } MAX-ACCESS read-write STATUS obsolete DESCRIPTION "The default configuration of the contact." ::= { upsContactEntry 4 } -------------------------------------------------------------------------- -- Legacy (PowerAlert version 11) traps, redefined as notifications. -- -- These notifications define the traps used in previous Tripplite MIBs and -- are only supported when legacy support is enabled, as indicated by -- tlEngineLegacySNMPSupport -------------------------------------------------------------------------- tlV11TrapsPrefix OBJECT IDENTIFIER ::= { trippUPS 0 } tlV11upsCritical NOTIFICATION-TYPE OBJECTS { upsTrapCode, upsTrapDescription } STATUS obsolete DESCRIPTION "UPS Critical Alarm." ::= { tlV11TrapsPrefix 100 } tlV11upsWarning NOTIFICATION-TYPE OBJECTS { upsTrapCode, upsTrapDescription} STATUS obsolete DESCRIPTION "UPS Warning." ::= { tlV11TrapsPrefix 101 } tlV11upsInformation NOTIFICATION-TYPE OBJECTS { upsTrapCode, upsTrapDescription} STATUS obsolete DESCRIPTION "UPS Information." ::= { tlV11TrapsPrefix 102 } tlV11upsAlarmCleared NOTIFICATION-TYPE OBJECTS { upsTrapCode, upsTrapDescription} STATUS obsolete DESCRIPTION "UPS Alarm Cleared." ::= { tlV11TrapsPrefix 103 } tlV11upsAgentStarted NOTIFICATION-TYPE OBJECTS { upsTrapCode, upsTrapDescription} STATUS obsolete DESCRIPTION "Agent started." ::= { tlV11TrapsPrefix 104 } tlV11upsAgentStopped NOTIFICATION-TYPE OBJECTS { upsTrapCode, upsTrapDescription} STATUS obsolete DESCRIPTION "Agent stopped." ::= { tlV11TrapsPrefix 105 } -------------------------------------------------------------------------- -- This is an excerpt from the TRIPPUPS-MIB used for Delta SNMP cards in -- Tripplite UPSs. It has major fundamental problems with OID collisions -- and naming collosions, so it's commented out in its entirety. It's -- only included for historical documentation purposes. -------------------------------------------------------------------------- -------------------------------------------------------------------------- -- BEGIN Delta SNMP MIB -------------------------------------------------------------------------- -- ups OBJECT IDENTIFIER ::= { trippUPS 1 } -- -- upsIdent OBJECT IDENTIFIER ::= { ups 1 } -- -- upsBattery OBJECT IDENTIFIER ::= { ups 2 } -- -- upsInput OBJECT IDENTIFIER ::= { ups 3 } -- -- upsOutput OBJECT IDENTIFIER ::= { ups 4 } -- -- upsAlarm OBJECT IDENTIFIER ::= { ups 6 } -- -- upsWellKnownAlarms OBJECT IDENTIFIER ::= { ups 7 } -- -- upsTest OBJECT IDENTIFIER ::= { ups 8 } -- -- upsControl OBJECT IDENTIFIER ::= { ups 9 } -- -- upsConfig OBJECT IDENTIFIER ::= { ups 10 } -- -- The Device Identification group. -- All objects in this group are set at device initialization and remain static. -- -- upsIdentManufacturer OBJECT-TYPE -- SYNTAX DisplayString (SIZE (0..31)) -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "The name of the UPS manufacturer." -- ::= { upsIdent 1 } -- -- -- upsIdentModel OBJECT-TYPE -- SYNTAX DisplayString (SIZE (0..63)) -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "The UPS Model designation." -- ::= { upsIdent 2 } -- -- -- upsIdentUPSSoftwareVersion OBJECT-TYPE -- SYNTAX DisplayString (SIZE (0..63)) -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "The UPS Firmware software version(s). This variable -- may or may not have the same value as -- upsIdentAgentSoftwareVersion in some implementations." -- ::= { upsIdent 3 } -- -- -- upsIdentAgentSoftwareVersion OBJECT-TYPE -- SYNTAX DisplayString (SIZE (0..63)) -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "The UPS agent software version. This variable may or -- may not have the same value as -- upsIdentUPSSoftwareVersion in some implementations." -- ::= { upsIdent 4 } -- -- -- upsIdentName OBJECT-TYPE -- SYNTAX DisplayString (SIZE (0..63)) -- ACCESS read-write -- STATUS obsolete -- DESCRIPTION -- "A string identifying the UPS. This object should be -- set by the administrator." -- ::= { upsIdent 5 } -- -- -- upsIdentAttachedDevices OBJECT-TYPE -- SYNTAX DisplayString (SIZE (0..63)) -- ACCESS read-write -- STATUS obsolete -- DESCRIPTION -- "A string identifying the devices attached to the -- output(s) of the UPS. This object should be set by -- the administrator." -- ::= { upsIdent 6 } -- -- -- The Battery group. -- Implementation of this group is mandatory for all systems. -- -- upsBatteryStatus OBJECT-TYPE -- SYNTAX INTEGER { -- unknown(1), -- batteryNormal(2), -- batteryLow(3), -- batteryDepleted(4) } -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "The indication of the capacity remaining in the UPS -- system's batteries. A value of batteryNormal -- indicates that the batteries are fully charged. A -- value of batteryLow indicates that the remaining battery -- run-time is less than or equal to -- upsConfigMinutesRemaining. A value of batteryDepleted -- indicates that the UPS will be unable to sustain the -- present load when and if the utility power is lost." -- ::= { upsBattery 1 } -- -- -- upsSecondsOnBattery OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "If the unit is on battery power, the elapsed time -- since the UPS last switched to battery power, or the -- time since the network management subsystem was last -- restarted, whichever is less. Zero shall be returned -- if the unit is not on battery power. UNITS - seconds" -- ::= { upsBattery 2 } -- -- -- upsEstimatedMinutesRemaining OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "An estimate of the time to battery charge depletion -- under the present load conditions if the utility power -- were to be lost and remain off. UNITS - minutes" -- ::= { upsBattery 3 } -- -- -- upsBatteryChargeRemaining OBJECT-TYPE -- SYNTAX INTEGER (0..100) -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "The estimate of the battery charge remaining expressed -- as a percent of full charge." -- ::= { upsBattery 4 } -- -- -- upsBatteryVoltage OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "The magnitude of the present battery voltage. UNITS 0.1 Volt DC." -- ::= { upsBattery 5 } -- -- -------------------------------------------------------------------------- -- Note : upsBatteryCurrent MIB variable removed by Dave Cole (SEC) on 4/24/95 -- To conform with older versions of this MIB, {upsBattery 6 } is reserved. -------------------------------------------------------------------------- -- -- upsBatteryTemperature OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "The ambient temperature at or near the UPS Battery. -- UNITS degrees Centigrade" -- ::= { upsBattery 7 } -- -- -- the table group has one attribute of its own - the number of rows in the -- contained table. It also contains the table of names. -- The Input group. -- Implementation of this group is mandatory for all systems. -- -- upsInputFrequency OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "The present input frequency. UNITS 0.1 Hertz" -- ::= { upsInput 1 } -- -- -- upsInputLineBads OBJECT-TYPE -- SYNTAX Counter -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "A count of the number of times the input entered an -- out-of-tolerance condition as defined by the manufacturer." -- ::= { upsInput 2 } -- -- -- upsInputNumLines OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "The number of input lines utilized in this device. -- This variable indicates the number of rows in the input table." -- ::= { upsInput 3 } -- -- -- upsInputVolt OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "The magnitude of the present input voltage. -- UNITS RMS Volts" -- ::= { upsInput 4 } -- -- -- upsInputTable OBJECT-TYPE -- SYNTAX SEQUENCE OF UpsInputEntry -- ACCESS not-accessible -- STATUS obsolete -- DESCRIPTION -- "A list of input table entries. The number of entries -- is given by the value of upsInputNumLines." -- ::= { upsInput 5 } -- -- -- upsInputEntry OBJECT-TYPE -- SYNTAX UpsInputEntry -- ACCESS not-accessible -- STATUS obsolete -- DESCRIPTION -- "An entry containing information applicable to a -- particular input line." -- INDEX { -- upsInputLineIndex } -- ::= { upsInputTable 1 } -- -- -- UpsInputEntry ::= SEQUENCE { -- upsInputLineIndex INTEGER, -- upsInputVoltage INTEGER } -- -- -- upsInputLineIndex OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "The input line identifier." -- ::= { upsInputEntry 1 } -- -- -- upsInputVoltage OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "The magnitude of the present input voltage. -- UNITS RMS Volts" -- ::= { upsInputEntry 2 } -- -- -- The Output group. -- Implementation of this group is mandatory for all systems. -- -- upsOutputSource OBJECT-TYPE -- SYNTAX INTEGER { -- other(1), -- none(2), -- normal(3), -- bypass(4), -- battery(5), -- booster(6), -- reducer(7) } -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "The present source of output power." -- ::= { upsOutput 1 } -- -- -- upsOutputFrequency OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "The present output frequency. -- UNITS 0.1 Hertz" -- ::= { upsOutput 2 } -- -- -- upsOutputNumLines OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "The number of output lines utilized in this device. -- This variable indicates the number of rows in the output table." -- ::= { upsOutput 3 } -- -- -- upsOutputPercLoad OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "The percentage of true power capacity presently being used. -- UNITS percent" -- ::= { upsOutput 4 } -- -- -- upsOutputTable OBJECT-TYPE -- SYNTAX SEQUENCE OF UpsOutputEntry -- ACCESS not-accessible -- STATUS obsolete -- DESCRIPTION -- "A list of output table entries. The number of -- entries is given by the value of upsOutputNumLines." -- ::= { upsOutput 5 } -- -- -- upsOutputEntry OBJECT-TYPE -- SYNTAX UpsOutputEntry -- ACCESS not-accessible -- STATUS obsolete -- DESCRIPTION -- "An entry containing information applicable to a -- particular output line." -- INDEX { -- upsOutputLineIndex } -- ::= { upsOutputTable 1 } -- -- -- UpsOutputEntry ::= SEQUENCE { -- upsOutputLineIndex INTEGER, -- upsOutputVoltage INTEGER, -- upsOutputCurrent INTEGER, -- upsOutputPower INTEGER, -- upsOutputPercentLoad INTEGER } -- -- -- upsOutputLineIndex OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "The output line identifier." -- ::= { upsOutputEntry 1 } -- -- -- upsOutputVoltage OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "The present output voltage. -- UNITS RMS Volts" -- ::= { upsOutputEntry 2 } -- -- -- upsOutputCurrent OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "The present output mandatory. -- UNITS 0.1 Amp" -- ::= { upsOutputEntry 3 } -- -- -- upsOutputPower OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "The present output true power. -- UNITS Watts" -- ::= { upsOutputEntry 4 } -- -- -- upsOutputPercentLoad OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "The percentage of true power capacity presently being used. -- UNITS percent" -- ::= { upsOutputEntry 5 } -- -- -- Alarm Group -- -- upsAlarmsPresent OBJECT-TYPE -- SYNTAX Gauge -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "The present number of active alarm conditions." -- ::= { upsAlarm 1 } -- -- -- upsAlarmID OBJECT-TYPE -- SYNTAX INTEGER { -- upsAlarmBatteryBad(1), -- upsAlarmOnBattery(2), -- upsAlarmLowBattery(3), -- upsAlarmDepletedBattery(4), -- upsAlarmTempBad(5), -- upsAlarmOutputOverload(6), -- upsAlarmOutputOffAsRequested(7), -- upsAlarmOutputOff(8), -- upsAlarmDiagnosticTestFailed(9), -- upsAlarmCommunicationsLost(10), -- upsAlarmShutdownPending(11), -- upsAlarmShutdownImminent(12), -- upsAlarmTestInProgress(13) } -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "A unique identifier for an alarm condition. This -- value must remain constant." -- ::= { upsAlarm 2 } -- -- -- upsAlarmDESCR OBJECT-TYPE -- SYNTAX DisplayString (SIZE (0..31)) -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "A reference to an alarm description object. The -- object references should not be accessible, but rather -- be used to provide a unique description of the alarm -- condition." -- ::= { upsAlarm 3 } -- -- -- upsAlarmTable OBJECT-TYPE -- SYNTAX SEQUENCE OF UpsAlarmEntry -- ACCESS not-accessible -- STATUS obsolete -- DESCRIPTION -- "A list of alarm table entries. The table consists of -- zero, one, or may rows at any moment, depending upon -- the number of alarm conditions in effect. The table -- is initially empty at agent startup. The agent -- creates a row in the table each time a condition is -- detected and deletes that row when that condition no -- longer pertains. The agent creates the first row with -- upsAlarmId equal to 1, and increments the value fo -- upsAlarmId each time a new row is created, wrapping to -- the first free value greater than or equal to 1 when -- the maximum value of upsAlarmId would otherwise be -- exceeded. Consequently, after multiple operations, -- the table may become sparse, e.g., containing entries -- for rows 95, 100, 101, and 203 and the entries are in -- chronological order until upsAlarmId wraps. -- -- Alarms are named by and OBJECT IDENTIFIER, -- upsAlarmDescr, to allow a single table to reflect well -- known alarms plus alarms defined by a particular -- implementation, i.e., as documented in the private -- enterprise MIB definition for the device. No two rows -- will have the same value of upsAlarmDescr, since -- alarms define conditions. In order to meet this -- requirement, care should be take in the definition of -- the number of active rows in the table at any given -- time is reflected by the value fo upsAlarms." -- ::= { upsAlarm 4 } -- -- -- upsAlarmEntry OBJECT-TYPE -- SYNTAX UpsAlarmEntry -- ACCESS not-accessible -- STATUS obsolete -- DESCRIPTION -- "An entry containing information applicable to a -- particular alarm." -- INDEX { -- upsAlarmId } -- ::= { upsAlarmTable 1 } -- -- -- UpsAlarmEntry ::= SEQUENCE { -- upsAlarmId INTEGER, -- upsAlarmDescr DisplayString, -- upsAlarmTime TimeTicks } -- -- -- upsAlarmId OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "A unique identifier for an alarm condition. This -- value must remain constant." -- ::= { upsAlarmEntry 1 } -- -- -- upsAlarmDescr OBJECT-TYPE -- SYNTAX DisplayString (SIZE (0..31)) -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "A reference to an alarm description object. The -- object references should not be accessible, but rather -- be used to provide a unique description of the alarm -- condition." -- ::= { upsAlarmEntry 2 } -- -- -- upsAlarmTime OBJECT-TYPE -- SYNTAX TimeTicks -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "The value of sysUpTime when the alarm condition was -- detected. If the alarm condition was detected at the -- time of agent startup and presumable existed before -- agent startup, the value of upsAlarmTime shall equal -- 0." -- ::= { upsAlarmEntry 3 } -- -- -- upsAlarmBatteryBad OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "One or more batteries have been determined to require -- replacement." -- ::= { upsWellKnownAlarms 1 } -- -- -- upsAlarmOnBattery OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "The UPS is drawing power from the batteries." -- ::= { upsWellKnownAlarms 2 } -- -- -- upsAlarmLowBattery OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "The remaining battery run-time is less than or equal -- to upsConfigMinutesRemaining." -- ::= { upsWellKnownAlarms 3 } -- -- -- upsAlarmDepletedBattery OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "The UPS will be unable to sustain the present load -- when and if the utility power is lost." -- ::= { upsWellKnownAlarms 4 } -- -- -- upsAlarmTempBad OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "A temperature is out of tolerance." -- ::= { upsWellKnownAlarms 5 } -- -- -- upsAlarmOutputOverload OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "The output load exceeds the UPS output capacity." -- ::= { upsWellKnownAlarms 6 } -- -- -- upsAlarmOutputOffAsRequested OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "The UPS has shutdown as commanded, i.e., the output is off." -- ::= { upsWellKnownAlarms 7 } -- -- -- upsAlarmUpsOutputOff OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "The UPS is in the off state." -- ::= { upsWellKnownAlarms 8 } -- -- -- upsAlarmDiagnosticTestFailed OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "The result of the last diagnostic test indicates a -- failure." -- ::= { upsWellKnownAlarms 9 } -- -- -- upsAlarmCommunicationsLost OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "A problem has been encountered in the -- communications between the agent and the UPS." -- ::= { upsWellKnownAlarms 10 } -- -- -- upsAlarmShutdownPending OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "A upsShutdownAfterDelay countdown is underway." -- ::= { upsWellKnownAlarms 11 } -- -- -- upsAlarmShutdownImminent OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "A upsShutdownAfterDelay countdown is underway." -- ::= { upsWellKnownAlarms 12 } -- -- -- upsAlarmTestInProgress OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "A upsShutdownAfterDelay countdown is underway." -- ::= { upsWellKnownAlarms 13 } -- -- Test Group -- -- upsTestId OBJECT-TYPE -- SYNTAX INTEGER { -- noTestsInitiated(1), -- abortTestInProgress(2), -- generalSystemsTest(3), -- checkBatteryTest(4), -- deepBatteryCalibration(5) } -- ACCESS read-write -- STATUS obsolete -- DESCRIPTION -- "The test named by an OBJECT IDENTIFIER which -- allows a standard mechanism for the initiation of -- test, including the well known tests identified in -- this document as well as those introduced by a -- particular implementation, i.e., as -- documented in the private enterprise MIB definition -- for the device. -- -- Setting this variable initiates the named test. Sets -- to this variable require the presence of -- upsTestSpinLock in the same SNMP message. -- -- The set request will be rejected with an appropriate -- error message if the requested test cannot be -- performed, including attempts to start a test when -- another test is already in progress. Tests in -- progress may be aborted by setting this variable to -- upsTestAbortTestInProgress. -- -- Read operations return the value of the name of the -- test in progress if a test is in progress or the name -- of the last test performed if no test is in progress, -- unless no test has bee run, in which case the well -- known value upsTestNoTestsInitiated is returned." -- ::= { upsTest 1 } -- -- -- upsTestResultsSummary OBJECT-TYPE -- SYNTAX INTEGER { -- donePass(1), -- doneWarning(2), -- doneError(3), -- aborted(4), -- inProgress(5), -- noTestsInitiated(6) } -- ACCESS read-only -- STATUS obsolete -- DESCRIPTION -- "The results of the mandatory or last UPS diagnostics -- test performed. The values for donePass(1), -- doneWarning(2), and doneError(3) are self-documenting. -- The value aborted(4) is returned for tests which are -- aborted by setting the value of upsTestId to -- upsTestAbortTestInProgress. Tests which have not yet -- concluded are indicated by inProgress(5). The value -- noTestsInitiated(4) indicates that no previous test -- results are available, such as in the case when no -- tests have been run since the last reinitialization of -- the network management subsystem and the system has no -- provision for non-volatile storage of test results." -- ::= { upsTest 2 } -- -- -------------------------------------------------------------------------- -- Note : upsTestResultsDetail MIB variable removed by Dave Cole (SEC) on 4/24/95 -- To conform with older versions of this MIB, {upsTest 3 } is reserved. -------------------------------------------------------------------------- -------------------------------------------------------------------------- -- Note : upsTestStartTime MIB variable removed by Dave Cole (SEC) on 4/24/95 -- To conform with older versions of this MIB, {upsTest 4 } is reserved. -------------------------------------------------------------------------- -- Control Group -- -- upsShutdownType OBJECT-TYPE -- SYNTAX INTEGER { -- output(1), -- system(2) } -- ACCESS read-write -- STATUS obsolete -- DESCRIPTION -- "Setting this object will start the output after the -- indicated number of seconds. Setting this object to 0 -- will cause the UPS to start the output immediately. -- If the output is already on at the time the delay has -- counted down, nothing will happen." -- ::= { upsControl 1 } -- -- -- upsShutdownAfterDelay OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-write -- STATUS obsolete -- DESCRIPTION -- "Setting this object will shutdown (i.e., turn off) -- either the UPS output or the UPS system (as determined -- by the value of upsShhutdownType at the time of -- shutdown) after the indicated number of seconds, or -- less if the UPS batteries become depleted. Setting -- this object to 0 will cause the shutdown to occur -- immediately. Setting this object to -1 will abort the -- countdown. If the system is already in the desired -- state at the time the countdown reaches 0, then -- nothing will happen. That is, there is no additional -- action at that time if upsShutdownType = system and -- the system is already off. Similarly, there is no -- additional action at that time if upsShutdownType = -- output and the output is already off. When read, -- upsShutdownAfterDelay will return the number of -- seconds remaining until shutdown, or -1 if no shutdown -- countdown is in effect. On some systems, if the agent -- is restarted while a shutdown countdown is in effect, -- the countdown may be aborted. Sets to this object -- override any upsShutdownAfterDelay already in effect. -- UNITS seconds" -- ::= { upsControl 2 } -- -- -- upsStartupAfterDelay OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-write -- STATUS obsolete -- DESCRIPTION -- "Setting this object will start the output after the -- indicated number of seconds, includeing starting the -- UPS, if necessary. Setting this object to 0 will -- cause the start to occur immediately. Setting this -- object to -1 will abort the countdown. If the output -- is already on at the time the countdown reaches 0, -- nothing will happen. Sets to this object -- override the effect of any upsStartupAfterDelay -- countdown or upsRebootDuration countdown in progress. -- When read, upsStartupAfterDelay will return the number -- of seconds until start, or -1 if no startup -- countdown is in effect. If the countdown expires -- during a utility failure, the startup shall depend -- upon the value of upsAutoRestart at that time. On -- some systems, if the agent is restarted while a -- startup countdown is in effect, the countdown is -- aborted. -- UNITS seconds" -- ::= { upsControl 3 } -- -- -- upsRebootDuration OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-write -- STATUS obsolete -- DESCRIPTION -- "Setting this object will immediately shutdown (i.e., -- turn off) either the UPS output or the UPS system (as -- determined by the value of the upsShutdownType at the time -- of shutdown) for a period equal to the indicated -- number of seconds, after which time the output will be -- started, including starting the UPS, if necessary. If -- the number of seconds required to perform the request -- is greater than the requested duration, then the -- requested shutdown and startup cycle shall be -- performed in the minimum time possible, but in no case -- shall this require more than the requested duration -- plus 60 seconds. When read, upsRebootDuration shall -- return the number of seconds remaining in the -- countdown, or -1 if no countdown is in progress. If -- the startup should occur during a utility failure, the -- startup shall depend on the value of upsAutoRestart -- at that time. -- UNITS seconds" -- ::= { upsControl 4 } -- -- -- upsAutoRestart OBJECT-TYPE -- SYNTAX INTEGER { -- on(1), -- off(2) } -- ACCESS read-write -- STATUS obsolete -- DESCRIPTION -- "Setting this object to 'on' will cause the UPS system -- to restart after a shutdown if/when utility power is present." -- ::= { upsControl 5 } -- -- -- upsConfig group -------------------------------------------------------------------------- -- Note : upsConfigInputVoltage MIB variable removed by Dave Cole (SEC) on 4/24/95 -- To conform with older versions of this MIB, {upsConfig 1 } is reserved. -------------------------------------------------------------------------- -------------------------------------------------------------------------- -- Note : upsInputFreq MIB variable removed by Dave Cole (SEC) on 4/24/95 -- To conform with older versions of this MIB, {upsConfig 2 } is reserved. -------------------------------------------------------------------------- -------------------------------------------------------------------------- -- Note : upsConfigOutputVoltage MIB variable removed by Dave Cole (SEC) on 4/24/95 -- To conform with older versions of this MIB, {upsConfig 3 } is reserved. -------------------------------------------------------------------------- -------------------------------------------------------------------------- -- Note : upsConfigOutputFreq MIB variable removed by Dave Cole (SEC) on 4/24/95 -- To conform with older versions of this MIB, {upsConfig 4 } is reserved. -------------------------------------------------------------------------- -------------------------------------------------------------------------- -- Note : upsConfigOutputVA MIB variable removed by Dave Cole (SEC) on 4/24/95 -- To conform with older versions of this MIB, {upsConfig 5 } is reserved. -------------------------------------------------------------------------- -------------------------------------------------------------------------- -- Note : upsConfigOutputPower MIB variable removed by Dave Cole (SEC) on 4/24/95 -- To conform with older versions of this MIB, {upsConfig 6 } is reserved. -------------------------------------------------------------------------- -------------------------------------------------------------------------- -- Note : upsConfigLowBattTime MIB variable removed by Dave Cole (SEC) on 4/24/95 -- To conform with older versions of this MIB, {upsConfig 7 } is reserved. -------------------------------------------------------------------------- -------------------------------------------------------------------------- -- Note : upsConfigAudibleStatus MIB variable removed by Dave Cole (SEC) on 4/24/95 -- To conform with older versions of this MIB, {upsConfig 8 } is reserved. -------------------------------------------------------------------------- -------------------------------------------------------------------------- -- Note : upsConfigLowVoltageTransferPoint MIB variable removed by Dave Cole (SEC) on -- 4/24/95. To conform with older versions of this MIB, {upsConfig 9 } is reserved. -------------------------------------------------------------------------- -------------------------------------------------------------------------- -- Note : upsConfigHighVoltageTransferPoint MIB variable removed by Dave Cole (SEC) on -- 4/24/95. To conform with older versions of this MIB, {upsConfig 10 } is reserved. -------------------------------------------------------------------------- -- upsConfigInputVoltageHigh OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-write -- STATUS obsolete -- DESCRIPTION -- "If the value of the input voltage (in Volts) exceeds this value, a -- utilityVoltageHigh trap will be triggered." -- ::= { upsConfig 11 } -- -- -- upsConfigInputVoltageLow OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-write -- STATUS obsolete -- DESCRIPTION -- "If the value of the input voltage (in Volts) falls below this value, a -- utilityVoltageLow trap will be triggered." -- ::= { upsConfig 12 } -- -- -- upsConfigOutputPercLoadHigh OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-write -- STATUS obsolete -- DESCRIPTION -- "If the value of the output percent load exceeds this value, a upsOverload trap -- will be triggered." -- ::= { upsConfig 13 } -- -- -- upsConfigBatteryPercLow OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-write -- STATUS obsolete -- DESCRIPTION -- "If the value of the battery percent capacity falls below this value, a lowBattery -- trap will be triggered." -- ::= { upsConfig 14 } -- -- -- upsConfigBatteryTemperatureHigh OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS read-write -- STATUS obsolete -- DESCRIPTION -- "If the value of the battery temperature exceeds this value, a -- batteryTemperatureHigh trap will be triggered." -- ::= { upsConfig 15 } -- -- -- -- Traps -------------------------------------------------------------------------- -- Note : upsOnBattery trap modified by Dave Cole (SEC) on 4/24/95 -- To conform with older versions of this MIB, trap 1 is reserved. -------------------------------------------------------------------------- -------------------------------------------------------------------------- -- Note : upsTestCompleted trap removed by Dave Cole (SEC) on 4/24/95 -- To conform with older versions of this MIB, trap 2 is reserved. -------------------------------------------------------------------------- -------------------------------------------------------------------------- -- Note : upsAlarmEntryAdded trap removed by Dave Cole (SEC) on 4/24/95 -- To conform with older versions of this MIB, trap 3 is reserved. -------------------------------------------------------------------------- -------------------------------------------------------------------------- -- Note : upsAlarmEntryDeleted trap removed by Dave Cole (SEC) on 4/24/95 -- To conform with older versions of this MIB, trap 4 is reserved. -------------------------------------------------------------------------- -- -- upsOnBattery TRAP-TYPE -- ENTERPRISE tripplite -- VARIABLES { -- upsIdentAttachedDevices, -- upsEstimatedMinutesRemaining} -- DESCRIPTION -- "The UPS is on battery." -- ::= 5 -- -- -- powerRestored TRAP-TYPE -- ENTERPRISE tripplite -- DESCRIPTION -- "Utility power has been restored." -- ::= 6 -- -- -- lowBattery TRAP-TYPE -- ENTERPRISE tripplite -- DESCRIPTION -- "The UPS batteries are low and will soon be exhausted." -- ::= 7 -- -- -- returnFromLowBattery TRAP-TYPE -- ENTERPRISE tripplite -- DESCRIPTION -- "The UPS has returned from a low battery condition." -- ::= 8 -- -- -- communicationEstablished TRAP-TYPE -- ENTERPRISE tripplite -- DESCRIPTION -- "Communication with the UPS has been established. This trap will be sent -- each time there is a transition from a power off condition to a power on condition." -- ::= 9 -- -- -- communicationLost TRAP-TYPE -- ENTERPRISE tripplite -- DESCRIPTION -- "Communication with the UPS has been lost." -- ::= 10 -- -- -- upsOverload TRAP-TYPE -- ENTERPRISE tripplite -- DESCRIPTION -- "The UPS has sensed a load greater than the value of the -- upsConfigOutputPercLoadHigh MIB variable." -- ::= 11 -- -- -- upsDiagnosticsFailed TRAP-TYPE -- ENTERPRISE tripplite -- DESCRIPTION -- "The UPS failed its self-test." -- ::= 12 -- -- -- upsDiagnosticsPassed TRAP-TYPE -- ENTERPRISE tripplite -- DESCRIPTION -- "The UPS passed its internal self-test." -- ::= 13 -- -- -- utilityVoltageHigh TRAP-TYPE -- ENTERPRISE tripplite -- DESCRIPTION -- "The UPS input voltage greater than or equal to the value of -- the upsConfigInputVoltageHigh MIB variable." -- ::= 14 -- -- -- utilityVoltageLow TRAP-TYPE -- ENTERPRISE tripplite -- DESCRIPTION -- "The UPS input voltage is less than or equal to the value of -- the upsConfigInputVoltageLow MIB variable." -- ::= 15 -- -- -- utilityVoltageReturnToNormal TRAP-TYPE -- ENTERPRISE tripplite -- DESCRIPTION -- "The UPS has returned from a utility voltage high or low condition." -- ::= 16 -- -- -- batteryTemperatureHigh TRAP-TYPE -- ENTERPRISE tripplite -- DESCRIPTION -- "The UPS battery temperature has exceeded the value of the -- upsConfigBatteryTemperatureHigh MIB variable." -- ::= 17 -- -- -- shutdownPending TRAP-TYPE -- ENTERPRISE tripplite -- DESCRIPTION -- "A UPS shutdown countdown is underway." -- ::= 18 -- -- -- upsSleeping TRAP-TYPE -- ENTERPRISE tripplite -- DESCRIPTION -- "The output of the UPS has been turned off." -- ::= 19 -- -- -- upsWokeup TRAP-TYPE -- ENTERPRISE tripplite -- DESCRIPTION -- "The output of the UPS has been turned on." -- ::= 20 -- -- -- upsBatteryNeedsReplacement TRAP-TYPE -- ENTERPRISE tripplite -- DESCRIPTION -- "The UPS battery needs to be replaced." -- ::= 21 -------------------------------------------------------------------------- -- END Delta SNMP MIB -------------------------------------------------------------------------- ENDDownload Driver Pack
After your driver has been downloaded, follow these simple steps to install it.
Expand the archive file (if the download file is in zip or rar format).
If the expanded file has an .exe extension, double click it and follow the installation instructions.
Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.
Find the device and model you want to update in the device list.
Double-click on it to open the Properties dialog box.
From the Properties dialog box, select the Driver tab.
Click the Update Driver button, then follow the instructions.
Very important: You must reboot your system to ensure that any driver updates have taken effect.
For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.