#################################################################### # Resource File Version 1.0 # # TEXT LABEL NAMES # #################################################################### MSG_PDMISSING_CONFIRM=Warning: This will mark the Physical Drive as Missing! Are you sure? RAID_LEVEL_1_DISPLAY_STRING=RAID 1 MSG_MEMFREE_FAILED=Failed to free memory PROPERTY_ISUARTPRESENT_TEXT=UART Present MANUAL_MODE_ARRAY=Array Selection AUTHENTICATE_DIALOG_TITLE=Enter User Name & Password RECONWIZARD_TEXT=Reconstruction Wizard IOPOLICY_CACHED=Cached IO LEGEND_UNUSED_TEXT=Available CONFIGWIZARD_TEXT=Configuration Wizard PROPERTY_DEVID_TEXT=Device ID PROPERTY_PSUPPLYNUMBER_TEXT=Number of Supplies MENU_LOGVIEW_TEXT=View Saved Log LEGEND_USED_TEXT=Configured LABEL_BGIRATE_TEXT=BGI Rate WRITEPOLICY_WRITE_BACK=Write Back BBU_MFG_DATE=Mfg Date OPERATION_INSTRUCTION_TEXT=<html>Select an operation from the left and press go to<br>invoke the selected Operation!</html> LABEL_EXISTINGARRAY_ONLY=Use Existing Arrays Only LDRIVE_STATE_OFFLINE=Offline PROPERTY_VENDORINFO_TEXT=Vendor ID MSG_SET_CONTROLLER_PROP=Warning: This will set controller properties. MSG_ASSISTEDCONF_FAILED=Assisted Configuration Failed! PDTYPE_FC=Fibre Channel BBU_MAX_ERROR=Maximum Error Margin MSG_FAILED_FOREIGNCFG=Cannot read Foreign Config! PROPERTY_FWSTATE_TEXT=Firmware State RECON_DRIVE_SEL=Drive Selection ENCL_ELEMSTATUS_UNRECOVERABLE=Unrecoverable ENCL_ELEMSTATUS_NOT_INSTALLED=Not Installed PROPERTY_SUBVENDORID_TEXT=SubVendor ID MSG_NO_FOREIGN_CONFIG=NO Foreign Configuration is found! MSG_RECON_INPROGRESS=Operation cannot be started while reconstruction is in progress! MSG_STATUS_GUIDEDFINISH=Change the number, size and other parameters for Virtual Disks and press Next BBU_TYPE=Battery Type GUIDED_MSG_TEXT=The capacity mentioned will be used as an approximation while creating the virtual disks. MENU_LOG_TEXT=Log MSG_DELPDFROMARRAY_LDEXISTS=Cannot delete Physical Drive from the array because one or more Virtual Disk is defined on this array! PROPERTY_CACHEFLUSHINTERVAL_TEXT=Cache Flush Interval BUTTON_GUIDEDCONF_TEXT=Guided Configuration MSG_IGNORE_FOREIGN_CONFIG=Do you want to ignore the foreign configuration? MSG_NOARRAY_SELECTED=Please specify an array! BUTTON_IMPORT_CONFIG=Import Configuration LABEL_UNUSEDARRAYS_TEXT=Unused Arrays BUTTON_RECLAIM_TEXT=Reclaim RAID_LEVEL_5_DISPLAY_STRING=RAID 5 MSG_CLEAR_FOREIGN_CONFIG=This will clear the selected Foreign Configuration! Are you sure? MSG_CONFIG_FAILED=Cannot write configuration: Unknown Exception! PROPERTY_RAWSIZE_TEXT=Raw Size PD_STATE_OFFLINE=Offline MSG_DISBL_ALARM=Warning: This will start Patrol Read operation. MSG_INVALID_CTRL=Incorrect controller number specified MSG_CONF_EXISTS=Configuration exists. You must clear the existing configuration before adding a new one. MSG_SCSINAME_FAILED=Failed to get SCSI device name PD_STATE_FAILED=Failed LEGEND_HIGHLIGHTED_TEXT=Selected VD BBU_MFG_NAME=Mfg Name ADAPTER_OPERATION_8_DESC=User configurable task rate priorities for controller FAILED_SERVER=Failed MSG_GUIDEDCONFIG_FAILED=Guided Configuration failed! MANUAL_DRIVE_SELECTION_JTABLE_PORT_COLUMN_HEADING=Port MANUAL_MODE_FINISH=Finish MSG_NOLD_SELECTED=Please specify a virtual disk! LABEL_CAPACITY_TEXT=Total Capacity: MSG_VERSION_MISMATCH=Mismatch in versions. BBU_OPERATION_REFRESH_DESC=Rescans and updates the BBU information RAID_LEVEL_3_DISPLAY_STRING=RAID 3 BBU_OPERATION_SLEEP=Sleep MSG_NOLD_TEXT=Please create at least one virtual disk and then proceed to next step! MSG_CONFIRM_ARRAYDELETE=This will delete the Array. Are you sure? MSG_STATUS_ARRAYSEL=Select one or more physical drive(s) and use the right arrow to move them to the right panel to create arrays MSG_FW_REBOOT=You must reboot the system to bring the firmware in effect ABOUT_OSVERSION_TEXT=Operating System Version DISK_CACHE_UNCHANGED=Unchanged PDTYPE_SATA=SATA PROPERTY_PDSTATE_TEXT=Physical Drive State MSG_INAVLID_PARAM=The input parameter to the command was invalid LOGICAL_TAB_TEXT=Logical BUTTON_UPDATE_TEXT=Update MAXPD_COUNT_TEXT=Maximum PD Count for patrolling: COER_MODE_128MB=128 MB PROPERTY_ISBBUPRESENT_TEXT=BBU Present MSG_STATUS_GUIDED=Select the choices given above and then proceed to next step for guided configuration LOG_DETAILS_DIALOG=Event Details PHDRIVE_OPERATION_1_DESC=Changes a drive from OFFLINE state to ONLINE state PROPERTY_YES_TEXT=Yes PROPERTY_DEFWRITEPOLICY_TEXT=Default Write Policy MSG_RECON_CHGRL=This operation cannot be aborted. Do you want to continue? LABEL_LDNUM_HINT=<html>Desired Number of Virtual Disks : <br> MSG_LINUX_LIBSYSFS_MISSING=libsysfs is not present in the system RECON_INSERT_BUTTON_TEXT=Add Drive LABEL_MB_TEXT=MB LABEL_REDUNDANCY_ONLY=Redundancy Only DEV_DIRECT_TEXT=Disk DIRECT_IO=Direct IO BBU_AVGTIMEFULL_CAPACITY=Average Time to Full MSG_INIT_FAILED=Storelib Initialization failed MSG_OP_TIMEDOUT=Command to driver timed out PRPOERTY_HOSTINTERFACE_TEXT=Host Interface PROPERTY_DEVICEPORTCOUNT_TEXT=Device Port Count PD_CACHE_ENABLE=Enable PROPERTY_RECONRATE_TEXT=Reconstruction Rate MSG_SELECT_ARRAY=Please select one or more arrays! MAX_DRIVE_SELECTION_EXCEEDED_TEXT=RECONSTRUCTION_CARD_TITLE LABEL_REDUNDANCY_NO=No Redundancy MSG_LOGIN_EXFAILURE=Login failed: Exception while login! LEGEND_LDRIVELOCATION_TEXT=Virtual Disk Location MSG_NOSTOARGEAPI=No Storage Controller Found! PROPERTY_TEMPERATURE_TEXT=Temperature LABEL_ELAPSED_TEXT=Elapsed time: PD_STATE_REBUILD=Rebuild READ_AHEAD_NONE=No Read Ahead LABEL_EXISTINGARRAYS_GROUP=Existing Arrays RECON_FINISH_SEL=Finish MSG_SETLDPARAM_FAILED=Cannot set virtual disk parameters! LABEL_USE_ALLARRAYS=Use Existing and New Arrays LABEL_ADD_HSP=-- Add Hotspare To -- MSG_ABORT_NOT_POSSIBLE=Abort not possible LABEL_VOLUMEPROP_TEXT=Virtual Disk Parameters SECOND_TEXT=second MENU_LOGSAVE_TEXT=Save Log BUTTON_BROWSE_TEXT=Browse PHDRIVE_OPERATION_10_DESC=Aborts Locate Physical Drive operation on a physical disk MSG_DEDICATEDHSP_FAILED=Cannot make dedicated hotspare: Error Code: LABEL_DEFWRITEPOLICY_TEXT=Default Write Policy: LABEL_EVENT_TYPE=Event Type: MSG_SETLDPROP_CONFIRM=Warning: This will set Virtual Disk properties! Are you sure? MENU_CONFIG_TEXT=Configuration ADAPTER_TEXT=Controller ABOUT_OSNAME_TEXT=Operating System Name LABEL_HOSTNAME_TEXT=Host MSG_CONFIRM_LOGOVERWRITE=File already exists. Do you want to overwrite? MSG_INVALID_FILETYPE=This is not a valid FW File! LABEL_ACCESSPOLICY_TEXT=Access Policy: MSG_CLEARCONFIG_FAILED=Clear Configuration failed: Unknown Exception PHDRIVE_OPERATION_2_DESC=Changes a drive from ONLINE state to OFFLINE state PDTYPE_UNKNOWN=Unknown GRP_SHOWPROGRESS_TITLE=Group Show Progress ENCL_ELEMSTATUS_NONCRITICAL=Non Critical MSG_PROTOCOL_ERROR=Fatal Error: Network protocol error! WRITEPOLICY_WRITE_THROUGH=Write Through PROPERTY_SLOTNUMBER_TEXT=Number of Slots PRODUCT_INFO=MegaRAID Storage Manager GRAPHICALVIEW_TAB_TEXT=Graphical View LABEL_TIME_STAMP=Time of Event: MSG_FLASHFW_CONFIRM=Warning: This will flash the controller firmware! Current firmware version is MSG_INITTYPE_TEXT=Initialization Type: PROPERTY_HOSTNAME_TEXT=Host Name PROPERTY_CLUSTERENABLE_TEXT=Cluster Enable SORTBYCOMBO_NAME_TEXT=Name MSG_LDPROGRESS_TEXT=Ongoing Operations on Virtual Disks NEWLDCREATED_TEXT=New Virtual Disk MENU_GRINITIALIZE_TEXT=Initialize BBU_TEMP_STATUS=Temperature ENCL_ELEMSTATUS_UNKNOWN=Unknown CACHED_IO=Cached IO LDRIVE_OPERATION_8=Set Virtual Disk Properties LDRIVE_OPERATION_7=Abort Initialization PD_STATE_HOTSPARE=Hot Spare LDRIVE_OPERATION_6=Start Initialization MSG_REDUNDANCY_TEXT=Redundancy Type: LDRIVE_OPERATION_5=Cancel Check Consistency NEXT_LEARNTIME_TEXT=Next Learn Time (sec): LDRIVE_OPERATION_4=Check Consistency BBU_AVGTIMEEMPTY_CAPACITY=Average Time to Empty MENU_CONFIGWIZARD_TEXT=Configuration Wizard VOLUME_CANDIDATE_PANEL_ADD=Add BUTTON_CONNECT_TEXT=Connect BUTTON_FINISH_TEXT=Finish LABEL_FWVERSION_TEXT=Framework Version: LD_ACCESS_RDONLY=Read Only PHDRIVE_OPERATION_11_DESC=Assigns the UNCONFIGURED GOOD drive as a global hotspare BBU_GAS_GAUGE=Gas Gauge Status LABEL_POWER_TEXT=Power Supply MSG_LOGIN_FAILURE=Login failed: Invalid username or password! MSG_STATUS_IR_MANUALVDCREATE=<html>Select one Array from the top left panel, change the various properties and press accept DISK_CACHE_DISABLED=Disabled MSG_CONFIRM=Are you sure? MSG_STATUS_FINISH=View the summary and finally press Finish to write the configuration NOBBU_TEXT=No Battery BBU_OPERATION_SETPROP_DESC=Defines various Battery Operation Parameters BBU_OPERATION_LEARN_DESC=Starts a battery calibration cycle LABEL_STRIPESIZE_TEXT=Stripe Size: PDTYPE_SAS=SAS RECON_REMOVE_BUTTON_TEXT=REMOVE LDRIVE_OPERATION_1_DESC=Deletes the specified virtual disk MSG_INIT_NOT_COMPLETED=Initialization was not yet completed. TEXT_CLIENT_TIME=Client time MSG_GET_PARTITION_FAILED=Failed to get partition. Partition may not exist PD_STATE_UNCONFGOOD=Unconfigured & Good FOREIGN_CONFIG_WIZARD=Foreign Configuration Wizard MSG_LDOS_MAP_INCOMPLETE=The LD to OS drive mapping is not complete. This will happen when fw reports SELECTED_DRIVES_TEXT=Selected Drives PROPERTY_ACCESSPOLICY_TEXT=Access Policy PROPERTY_FLASHSIZE_TEXT=Flash Size PROPERTY_ISNVRAMPRESENT_TEXT=NVRAM Present BBU_FW_STATUS=Firmware Status LABEL_POWERS_TEXT=Power Supplies PROPERTY_PREDFAILCOUNT_TEXT=Pred Fail Count PROPERTY_LDCOUNT_TEXT=Virtual Disk Count ADAPTER_TYPE_PCIX=PCIX AUTO_MODE_FINISH=Finish MSG_PDREBUILD_CONFIRM=Warning: This will rebuild the Physical Drive! Are you sure? PROPERTY_LDDEGRADEDCOUNT_TEXT=Degraded Virtual Disk Count BBU_ABSCHARGE_STATE=Absolute State of Charge PROPERTY_LDRIVESIZE_TEXT=Size ADAPTER_TYPE_PCIE=PCIE MSG_INVALID_ARRAYSIZE=Please Create arrays with at least 2 physical drives then go to next step! LABEL_READPOLICY_TEXT=Read Policy: GUIDED_CONFIG_STEP3=Finish GUIDED_CONFIG_STEP2=Virtual Disk Parameters BUTTON_ABORT_TEXT=Abort GUIDED_CONFIG_STEP1=Guided Config MSG_AUTOCONFIG_FAILED=Auto Configuration failed! RECON_DELETE_BUTTON_TEXT=Remove Drive MSG_ABORTPROG_CONFIRM=Do you want to abort this operation? BBU_OPERATION_REFRESH=Refresh PROPERTY_FWBUILDTIME_TEXT=Firmware Build Time BBU_DESIGN_CAPACITY=Design Capacity READ_AHEAD_ALWAYS=Always Read Ahead LABEL_FANS_TEXT=Fans SORTBYCOMBO_TYPE_TEXT=Type MSG_CANNOT_ABORT_OP=The operation cannot be aborted! PHDRIVE_OPERATION_12_DESC=Designates a ready or UNCONFIGURED GOOD drive as a dedicated hotspare to the specified array(s) LABEL_NOREDUNDANCY_TEXT=No Redundancy MSG_PDOFFLINE_CONFIRM=Warning: This will make the Physical Drive Offline! Are you sure? RECON_NOCHANGE_BUTTON_TEXT=Change RAID Level GRP_INITDLG_TITLE=Group Initialization BBU_TEXT=Battery Backup Unit LABEL_LDNAME_TEXT=Name: STATUS_LOG_SERVER=Displaying log from server LDRIVE_OPERATION_2_DESC=Identifies virtual disk members by blinking the associated physical disk(s) activity LED PROPERTY_CURWRITEPOLICY_TEXT=Current Write Policy MSG_DELARRAY_ILLEGAL=Cannot delete new Array: Illegal Configuration Exception! LABEL_DOMAIN_ADDR=Connect to remote Framework at: MSG_INVALID_LDOPTION=cannot create Virtual Disk: Invalid input parameters for creating Virtual Disk! NEWLD_PROPERTY_INPUT=Virtual Disk Properties PROPERTY_ISCLUSTERACTIVE_TEXT=Cluster Active LOGGERHEADER_DESCRIPTION_TEXT=Description LABEL_OSNAME_TEXT=OS MENU_FILE_TEXT=File FULL_INIT_TEXT=Full Initialization TEXT_SEC_FRM_REBOOT=seconds from reboot PROPERTY_No_TEXT=No PROPERTY_HOSTPORTCOUNT_TEXT=Host Port Count BBU_TYPE_BBU=BBU WRITEPOLICY_WRITE_ADAPTIVE=Write Adaptive ABOUT_SERVERINFO_TEXT=Server Info LABEL_SELECTLD_TEXT=Select Excluded Virtual Disks: NO_FIRMWARE_FILE=Please specify a valid firmware file! PROPERTY_LDRIVERL_TEXT=Current RAID Level MSG_CONFIRM_ADDCFG=<html>This operation will try to configure the controller based on a saved configuration.<br>Unstable conditions might arise due to difference in physical devices in the two configurations.<br>Are you sure ?</html> ABOUT_HOSTNAME_TEXT=HostName MENU_LOGCLEAR_TEXT=Clear Log HEALTHY_SERVER=Healthy ACCESS_READ_WRITE=Read Write PHDRIVE_OPERATION_13_DESC=Removes the hotspare assignment and changes the drive state to UNCONFIGURED GOOD ADAPTER_OPERATION_1_DESC=Sets controller alarm to on to alert user when the controller MENU_HELP_TEXT=Help PROPERTY_REVLEVEL_TEXT=Revision Level PD_CACHE_DISABLE=Disable BUTTON_AUTOCONF_TEXT=Auto Configuration SERVERINFO_LABEL_TEXT=Server Information LABEL_REDUNDANCY_GROUP=Redundancy PROPERTY_HOSTOSARCH_TEXT=OS Architecture LDRIVE_STATE_PARTDERGRADED=Partially Degraded MSG_GETRDLEVELSIZE_FAILED=Cannot get possible RAID level and size: Unknown Exception! MINUTE_TEXT=minute LABEL_LDSUMMARY_TEXT=Virtual Disk Summary MENU_OPERATION_TEXT=Operations ACCEPT_ARRAY=Accept MSG_DELETELD_CONFIRM=Warning: This will delete the Virtual Disk! Are you sure? LABLE_KERNELVERSION_TEXT=Kernel Version: PD_STATE_UNCONFBAD=Unconfigured & Bad LDRIVE_OPERATION_3_DESC=Aborts the Locate Virtual Disk operation PROPERTY_COERCEDSIZE_TEXT=Coerced Size PHDRIVE_OPERATION_5_DESC=Replaces a drive of a degraded array that is marked missing with an UNCONFIGURED GOOD drive PROPERTY_REBUILDRATE_TEXT=Rebuild Rate PROPERTY_HOSTOSVER_TEXT=OS Version MSG_FATAL_RESCAN_ERROR=Fatal error: rescan failed! Exiting... PROPERTY_DEVICEPORTADDRESS_TEXT=Device Port Address DEGRADED_SERVER=Degraded ENCLOSURE_TEXT=Enclosure PROPERTY_FWVERSION_TEXT=Firmware Version LABEL_NUMVIRTUALDISK_TEXT=Virtual Disk Count: MSG_CONFIRM_LOGSAVE_BEFORE_DELETE=Do you want to save the existing log? OPERATION_RECON_TEXT=Reconstruction FREQUENCY_TEXT=Execution Frequency: LABEL_ESTIMATED_TEXT=Estimated time left: LABEL_ARRAY_FREE=Arrays with Available Space MSG_NOCONFIG_POSSIBLE=No new Virtual Disk can be added to the configuration! LABEL_WITHREDUNDANCY_TEXT=With Redundancy PROPERTY_MEMUNCORRECTABLEERRORCOUNT_TEXT=UnCorrectable Error Count MSG_INVALID_DATA=Invalid data sent to driver MSG_INVALID_OPSTATE=The drive is not in a state to perform LD_ACCESS_BLOCKED=Blocked GUIDED_CONFIG_STEP=Finish MSG_INVALID_IPADDR=Invalid IP Address! AUTOLEARN_PERIOD_TEXT=Auto Learn Period (sec): MENU_RECONWIZARD_TEXT=Reconstruction Wizard COER_MODE_1GB=1 GB MSG_FULLACCESS_DENIED=<html>Full Access denied because another user is logged in<br> with full access from IP Address: MSG_UNKNOWN_ERROR=Operation Failed OPMODE_MANUAL=Manual PROPERTY_ALARMENABLE_TEXT=Alarm Enabled BBU_NEXTLEARN_TIME=Next Learn Time PHDRIVE_TEXT=Physical Drive MSG_DATA_BAKUP=It is advisable to backup data before this operation. Are you ready? ABOUT_OKBUTTON_TEXT=OK PROPERTY_SASADDR_TEXT=Backend SAS Address PROPERTY_ISALARMPRESENT_TEXT=Alarm Present LOGINMODE_TEXT=Login Mode: PHDRIVE_OPERATION_14_DESC=Spins down the selected drive to ready it for removal ADAPTER_OPERATION_2_DESC=Sets the audible controller alarm option to off PROPERTY_BIOSVERSION_TEXT=BIOS Version MSG_CONFIRM_LOGDELETE=This will delete the log. Are you sure? BUTTON_ADDHSP_TEXT=Add HotSpare CHECKBOX_WITHFIX_TEXT=Automatically Fix errors LABEL_UNCONF_PDLIST=Unconfigured Physical Drive List LABEL_NO_EXISTINGARRAY=Do not use Existing Arrays PROPERTY_WRITEPOLICY_TEXT=Write Policy MSG_REMOVEHSP_FAILED=Cannot remove hotspare! BUTTON_CANCEL_FOREIGN_CONFIG=Cancel MSG_LD_ZERO=Total Number of Virtual Disks must be greater than 0! PROPERTY_TAB_TEXT=Properties MENU_ADVANCED_OP=Advanced Operations MSG_CONN_LOST=Connection to the server has been lost. Do you want to re-login? LDRIVE_OPERATION_4_DESC=Starts a check consistency operation on the selected virtual disk PHDRIVE_OPERATION_6_DESC=Marks an offline/failed drive of a degraded array as missing in order to prepare for drive replacement OPERATION_MODE_TEXT=Operation Mode: MSG_DELPDFROMARRAY_FAILED=Cannot delete Physical Drive from the array! MSG_RAID0_NOTPOSSIBLE=RAID 0 is not possible as there is dedicated hotspare for the specified arrays RAID_LEVEL_0_DISPLAY_STRING=RAID 0 MSG_ABORTALL_CONFIRM=This will abort all the operations shown above! Are you sure? MENU_EXIT_TEXT=Exit STATUS_LOG_LOCAL=Displaying log from file PROPERTY_MEMCORRECTABLEERRORCOUNT_TEXT=Correctable ErrorCount LABEL_CCRATE_TEXT=Check Consistency Rate PROPERTY_DEVICEID_TEXT=Device ID PROPERTY_SLOT_NUMBER=Slot Number OPERATION_BGI_TEXT=Background Initialize MANUAL_DRIVE_SELECTION_JTABLE_CAPACITY_COLUMN=Drive Capacity (in MB) PROPERTY_PRODUCTINFO_TEXT=Product Info MENU_GRCHKCONSISTENCY_TEXT=Check Consistency BGINIT_DISABLE=Disabled BUTTON_SELECTALL_TEXT=Select All MSG_FAIL_SAVE_CONFIG=Save configuration failed BUTTON_START=Start LABEL_INITSTATE_TEXT=Init State: SERVER_TEXT=Server MSG_THREAD_CREATE_FAILED=Thread creation failed PROPERTY_HOSTSTATUS_TEXT=Status MSG_CMDFAILED_OS=Command failed by Operating System MENU_LOADPLUGINS_TEXT=Load Plugins MAX_DRIVE_SELECTION_TEXT=Select Physical Drives LOGGERHEADER_DATETIME_TEXT=Date / Time LABEL_RAIDLEVEL_TEXT=RAID Level: OPERATION_PATROLREAD_TEXT=Patrol Read MSG_SELECTHOST=Please selected a host from the list! MSG_LINUX_SYSFS_ERROR=An error occurred while accessing sysfs PROPERTY_DEVICETYPE_TEXT=Device Type PROPERTY_NO_TEXT=No PROPERTY_PRODUCTID_TEXT=Product ID SORTBYCOMBO_IPADDRESS_TEXT=IP Address PROPERTY_STRIPESIZE_TEXT=Stripe Size PHDRIVE_OPERATION_15_DESC=Cancels Prepare For Removal operation on a physical disk BBU_SERIALNO=Serial No ADAPTER_OPERATION_3_DESC=Temporarily quiets the controller alarm for the current event LABEL_SENSORS_TEXT=Sensors: MSG_ABOUT_LINE2=Copyright \u00a9 2006 LSI Logic Corporation. All Rights Reserved. RECON_MODE_SEL=Reconstruction Mode MSG_ABOUT_LINE1=Client Build: LOGINMODE_FULLACCESS=Full Access PROP_PDSASADDR_TEXT=SAS Address LEGEND_UNUSABLE_TEXT=Reserved PD_CACHE_UNCHANGED=Unchanged VALUE_NOT_AVAILABLE=Not Available PHDRIVE_OPERATION_15=Undo Prepare For Removal PHDRIVE_OPERATION_14=Prepare For Removal PHDRIVE_OPERATION_13=Remove Hotspare PHDRIVE_OPERATION_12=Make Dedicated Hotspare MSG_INIT_NOT_DONE=Storelib Initialization not completed PHDRIVE_OPERATION_11=Make Global Hotspare MSG_INVALID_CMD=Invalid Operation PHDRIVE_OPERATION_10=Stop Locating Physical Drive MSG_INVALID_FLASH_IMAGE=The firmware flash image is invalid MSG_RECON_NOTALLOWED=Reconstruction on this Volume is not allowed! BBU_FULL_CAPACITY=Full Capacity MSG_NO_CONNECTION=Fatal Error: Cannot connect to Framework! LDRIVE_OPERATION_5_DESC=Cancels the current check consistency operation on the selected virtual disk OPMODE_DISABLED=Disabled MSG_CONFIG_CORRUPTED=Configuration Corrupted! PHDRIVE_OPERATION_7_DESC=This option will start rebuild on selected offline/failed drive BUTTON_CLEAR_CONFIG=Clear Configuration LOGGERHEADER_ERRORLEVEL_TEXT=Error Level PROPERTY_MEMORYSIZE_TEXT=Memory Size VOLUME_CANDIDATE_PANEL_REMOVE=Remove ACCESS_READ_ONLY=Read Only ADAPTER_TYPE_SAS_3G=SAS_3G PROPERTY_IOPOLICY_TEXT=IO Policy PROPERTY_READPOLICY_TEXT=Read Policy MANUAL_DRIVE_SELECTION_JTABLE__DEVID_COLUMN=Device ID MSG_CLEAR_FOREIGN_FAILED=Clear Foreign Config failed! PROPERTY_DISKCACHEPOLICY_TEXT=Disk Cache Policy PROP_SCSIDEVTYPE_TEXT=SCSI Device Type WRITE_BACK=Write Back RAID_LEVEL_TEXT=RAID PROPERTY_RAIDLEVEL_TEXT=RAID Level LABEL_STATE_TEXT=State: BBU_OPERATION_LEARN=Learn PROPERTY_COERCIONMODE_TEXT=Coercion Mode BBU_DESIGN_VOLTAGE=Design Voltage LDRIVE_STATE_DEGRADED=Degraded SORTBYCOMBO_OS_TEXT=OS RECON_ADD_BUTTON_TEXT=ADD NEWLD_TEXT=New Virtual Disks MSG_LINUX_SYSFS_NOTMOUNTED=sysfs is not mounted in the system COER_MODE_NONE=None LD_ACCESS_RDWRITE=Read Write ACCESS_BLOCKED=Blocked LABEL_FAN_TEXT=Fan MSG_NO_MORE_VD=No more virtual disk can be added MSG_IMPORT_FOREIGNCFG_SUCCESS=Foreign Configuration was imported successfully! MSG_NOLD_POSSIBLE=Please Create at least one array then go to next step! PROPERTY_HOSTOS_TEXT=Operating System MSG_NOSERVER_FOUND=No Servers found! MENU_LOGREMOTE_TEXT=Revert to Current Log PROPERTY_PATROLREADRATE_TEXT=Patrol Read Rate ADAPTER_OPERATION_4_DESC=Updates controller firmware with a specified firmware image BUTTON_ACCEPT_TEXT=Accept MSG_NOASSISTED_POSSIBLE=No configuration possible for the given parameters! PROPERTY_CCRATE_TEXT=Consistency Check Rate LDRIVE_TEXT=Virtual Disk IOPOLICY_DIRECT=Direct IO RAID_TEXT=RAID TEXT_GUID=GUID MSG_SAVELOG_INVALIDFILE=Cannot save to the file specified! Device not ready! BUTTON_NEXT_TEXT=Next OPERATION_FGI_TEXT=Foreground Initialize OPMODE_AUTO=Auto BUTTON_DESELECTALL_TEXT=Deselect All STATUS_LOG_FILE_ERROR=No Valid Log found in LDRIVE_OPERATION_6_DESC=Starts an initialization operation on the selected virtual disk MSG_ILLEGAL_CONFIG=Cannot create new Array: Illegal Configuration Exception! PHDRIVE_OPERATION_8_DESC=Cancels the current rebuild operation on a physical drive PROPERTY_PDTYPE_TEXT=Physical Drive Type MSG_MAXLDNUM_EXCEEDED=Total number of Virtual Disks must not exceed MSG_SELCCLDRIVE_TEXT=Select Virtual Disks: OPERATION_REBUILD_TEXT=Rebuild NEW_ARRAY_TEXT=New Array OPERATIONS_TAB_TEXT=Operations PROPERTY_VENDORID_TEXT=Vendor ID MSG_CONFIG_NOTALLOWED=Configuration on this adapter is not allowed! ABOUT_OSARCHI_TEXT=Operating System Architecture MSG_UNKNOWN=Unknown Exception! GRP_CONCHECK_TITLE=Group Consistency Check LABEL_RAID_TEXT=RAID BBU_RUNTIMEEMPTY_CAPACITY=Run time to Empty MSG_STATUS_MANUALVDCREATE=<html>Check one or more Array holes from the top left panel, change the various properties and press accept MSG_INVALID_INPUT=Invalid input specified! BUTTON_MODIFY_TEXT=Modify PASSWORD_TEXT=Password: SERVERS_BUTTON_TEXT=Servers LABEL_PATROLREADRATE_TEXT=Patrol Rate ABOUT_IPADDRESS_TEXT=IP Address READ_AHEAD_ADAPTIVE=Adaptive Read Ahead BBU_OPERATION_SLEEP_DESC=Sets the BBU to low power storage mode BBU_REM_CAPACITY=Remaining Capacity ARRAY_WITH_HOLES=Arrays with Free Space PROPERTY_BIOSBUILDTIME_TEXT=BIOS Build Time MODE_SEL_STEP=Mode Selection MSG_IMPORT_FOREIGNCFG_FAILED=Import foreign configuration failed! LABEL_REDUNDANCY_TRY=Redundancy when possible ADAPTER_OPERATION_5_DESC=Sets patrol read options for configured physical drives BBU_VOLTAGE_STATUS=Voltage BUTTON_OPERATION_GO=Go MSG_NOT_RESPONDING=Framework not responding! MENU_GRPROGRESS_TEXT=Show Progress MENU_FOREIGN_CONFIG=Scan For Foreign Config MSG_CANNOT_ABORT=Cannot be aborted! MSG_MEMALOC_FAILED=Failed to allocate memory WRITE_THROUGH=Write Through DISK_CACHE_ENABLED=Enabled LABEL_TEMPERATURE_TEXT=Temperature MSG_MAXEVENT_EXCEEDED=The maximum number of events that can be retrieved has exceeded BBU_OPERATION_SETPROP=Set BBU Properties LDRIVE_OPERATION_7_DESC=Cancels the current initialization operation on the selected virtual disk PHDRIVE_OPERATION_9_DESC=Identifies a physical disk by blinking the associated physical disk activity LED BUTTON_CANCEL_TEXT=Cancel MSG_MAXCONFIG_EXCEEDED=Max Configuration limit exceeded! ADAPTER_TYPE_ISCSI=Unknown MENU_RESCAN_TEXT=Rescan BUTTON_MANUALCONF_TEXT=Manual Configuration LABEL_SENSOR_TEXT=Sensor TEXT_ARRAY_ROW=Row Index MENU_PLUGINS_TEXT=Plugins BUTTON_ABORTALL_TEXT=Abort All[A] ENCL_ELEMSTATUS_OK=OK BUTTON_LOGIN_TEXT=Login USERNAME_TEXT=User Name: HOLE_TEXT=Hole MSG_BIG_LDNAME=Virtual Disk Name is too big! MENU_GROUPOPERATION_TEXT=Group Operations BUTTON_CLOSE_TEXT=Close[C] PROPERTY_SERIALNO_TEXT=Serial No LOGINMODE_VIEWONLY=View Only PROPERTY_LDSTATE_TEXT=Virtual Disk State PROPERTY_MEDIACOUNT_TEXT=Media Error Count PROPERTY_DISKWRITECACHEDISABLE_TEXT=Disk Write Cache Disable LDRIVE_STATE_OPTIMAL=Optimal MSG_LDDELETE_DATA_LOST=Data contained in the virtual drive will be lost. Do you want to continue? DEV_TAPE_TEXT=TAPE PDTYPE_SCSI=SCSI MSG_ADDHOTSPARE_FAILURE=Cannot add Hotspare to the array! LABEL_BACKGROUNDINIT_TEXT=Background Initialization: CHECKBOX_FASTINIT_TEXT=Fast Initialization PROPERTY_BGIRATE_TEXT=BGI Rate MSG_CONFIRM_CFGOVERWRITE=This will overwrite the existing configuration. Are you sure? MANUAL_MODE_LOGICALDRIVE=Virtual Disk Creation BUTTON_REMOVEHSP_TEXT=Remove HotSpare PROPERTY_HOSTPORTADDRESS_TEXT=Host Port Address MENU_HELPME_TEXT=Help UNUSED_ARRAYS_TEXT=Unused Arrays LABEL_PATROL_CONTINUOUS=Continuous Patrolling BBU_CURRENT_STATUS=Current SELECT_RAID_LEVEL_TEXT=New RAID Level BBU_RELCHARGE_STATE=Relative State of Charge PROPERTY_LDFAILEDCOUNT_TEXT=Failed Virtual Disk Count MSG_NO_OP_SELCTED=Please select an operation ! ADAPTER_OPERATION_6_DESC=Starts patrol read operation on the selected physical drives LABEL_VOLUMENAME_TEXT=Volume Name : ARRAY_TEXT=Array MSG_LDINIT_DATA_LOST=Initialization will result in data loss on the selected Virtual Disk(s). Proceed ? PROPERTY_LDRIVENAME_TEXT=Name MSG_FAIL_ADD_CONFIG=Add configuration failed MENU_ABOUT_TEXT=About MSG_NOMORE_ARRAY=No more array can be created : Maximum Number is : OPERATION_CLEAR_TEXT=Clear ENCL_ELEMSTATUS_NOT_AVAILABLE=Not Available OPERATION_CC_TEXT=Check Consistency LDRIVE_OPERATION_8_DESC=Defines virtual disk operation parameters PROPERTY_FANNUMBER_TEXT=Number of Fans ADAPTER_OPERATION_8=Set Adjustable Task Rates PROPERTY_HOSTIP_TEXT=IP Address ADAPTER_OPERATION_7=Stop Patrol Read PORT_TEXT=Port ADAPTER_OPERATION_6=Start Patrol Read MSG_DELARRAY_FAILED=Cannot delete new Array: Unknown Exception! ADAPTER_OPERATION_5=Set Patrol Read Properties ADAPTER_OPERATION_4=Flash Firmware ADAPTER_OPERATION_3=Silence Alarm VERSIONINFO_LABEL_TEXT=Version Information ADAPTER_OPERATION_2=Disable Alarm MSG_STATUS_MODESEL=Select one of the modes of configuration ADAPTER_OPERATION_1=Enable Alarm ENCL_ELEMSTATUS_CRITICAL=Critical MSG_PDPROGRESS_TEXT=Ongoing Operations on Physical Drives PHYSICAL_TAB_TEXT=Physical MSG_ARRAYCREATIONIR_FAILED=Cannot create new Array: At least 2 physical drives needed! PROPERTY_NVRAMSIZE_TEXT=NVRAM Size MSG_MAXPDINARRAY_EXCEEDED=No more Physical Drive can be added to this array: Maximum Number is: LABEL_DISKCACHEPOLICY_TEXT=Disk Cache Policy: PROPERTY_PRODUCTNAME_TEXT=Product Name HOUR_TEXT=hour LABEL_SORTBY_TEXT=Sort By LABEL_IPADDRESS_TEXT=IP Address LABEL_SIZE_TEXT=Size (in MB): SELARRAY_DEDICATEDHSP_TEXT=Select arrays LABEL_RECONRATE_TEXT=Reconstruction Rate BBU_CYCLE_COUNT=Cycle Count BUTTON_BACK_TEXT=Back IBBU_TEXT=IBBU DEV_CDROM_TEXT=CDROM MSG_DEVNOT_RESPONDING=Device not responding! HOTSPARE_TEXT=HotSpare Physical Drive MSG_STATUS_AUTOCONFIG=Select modify to make desired changes to auto configuration parameters or Select Finish to complete Auto Configuration Wizard. MSG_LINUX_SCSIMAP_FAILED=The SCSI device to SCSI address mapping failed BBU_AUTOLEARN_PERIOD=Auto Learn Period MSG_DELETLD_FAILED=Cannot delete newly created Virtual Disk: Unknown Exception! MSG_PDREMOVEHSP_CONFIRM=Warning: This will remove the hotspare drive! Are you sure? MSG_MUTEX_CREATE_FAILED=Mutex creation failed MSG_NOADMIN_RIGHT=This user does not have Administrator right for this system! PD_STATE_ONLINE=Online LABEL_VOLUMEID_TEXT=Volume ID: LABEL_REBUILDRATE_TEXT=Rebuild Rate PROPERTY_LDONLINECOUNT_TEXT=Online Virtual Disk Count PHDRIVE_OPERATION_9=Locate Physical Drive PHDRIVE_OPERATION_8=Abort Rebuild PHDRIVE_OPERATION_7=Rebuild PHDRIVE_OPERATION_6=Mark Physical Drive as Missing COMBO_SELECTLDRIVE_TEXT=-- Select Virtual Disk (VD) -- PHDRIVE_OPERATION_5=Replace Missing Physical Drive PHDRIVE_OPERATION_4=Stop Patrol Read PHDRIVE_OPERATION_3=Start Patrol Read PHDRIVE_OPERATION_2=Make Drive Offline PHDRIVE_OPERATION_1=Make Drive Online ADAPTER_OPERATION_7_DESC=Stops the current patrol read operation MSG_NOMORE_ARRAY_INONESHOT=No more array can be created in one shot LABEL_FILETYPE_ROM=ROM Files (*.rom) POSTPONELEARN_DELAY_TEXT=Postpone Learn Delay Interval (hours): MSG_CONFIG_OS_DRIVE_PRESENT=This configuration contains at least one OS drive. Configuration cannot be cleared. MSG_OS_LD=This is an OS drive. This virtual drive cannot be deleted. PROPERTY_ENCLOSURE_TYPE_TEXT=Enclosure Type PROPERTY_ENCLOSURE_TYPE_VIRTUAL=Virtual MSG_NEW_VERSION=and the new version is MENU_ADD_CONFIG=Add Configuration from file MENU_SAVE_CONFIG=Save Configuration MENU_CLEAR_CONFIG=Clear Configuration OPERATION_SELECTION_TEXT=Selected Operation : OPERATION_DESC_TEXT=Description : LDRIVE_OPERATION_1=Delete Virtual Disk LDRIVE_OPERATION_2=Locate Virtual Disk LDRIVE_OPERATION_3=Stop Locating Virtual Disk MSG_RECONS_ERR_UNKNOWN=Reconstruction failed : Unknown error MSG_PD_TYPE_WRONG=Configuration is not possible with SAS/SATA mixed drives MSG_SAS_SATA_MIX_NOT_ALLOWED=Configuration is not possible with SAS/SATA mixed drives. Please select same types of drive to add into this array. TXT_DAYS= Days RECON_DRIVE_ADD_MESSAGE=<HTML>Select drive(s) that you want to add to the volume.<BR>You may select a maximum of {0,number} drives</HTML> RECON_DRIVE_REMOVE_MESSAGE=<HTML>Select drive that you want to remove to the volume.<BR>You may select a maximum of {0,number} drive</HTML> MSG_CLEARCONFIG_CONFIRM=Clearing the configuration will destroy virtual disks and result in data loss on the selected controller. Proceed ? QUICK_INIT_TEXT=Fast Initialization NO_INIT_TEXT=No Initialization MSG_CONFIRM_LDRECLAIM=This will delete the newly created Virtual Disk! Are you sure? AUTOLEARN_MODE_TEXT=Auto Learn Mode: AUTO_LEARN_WARN=Warn AUTO_LEARN_MODE=Auto Learn Mode TXT_PROGRESS_HRS= Hrs TXT_PROGRESS_MIN= Min TXT_PROGRESS_SEC= Sec ZCR_LEGACY_TEXT=ZCR Legacy MSG_WRITE_BACK_WARN=Write-through is recommended for maximum data integrity when no battery is present ! MSG_COMPONENT_NOT_RUNNING_ERROR=Error : One or more target component is not running. MSG_CONFIGURATOR_NOT_RESPONDING_ERROR=Error : Configurator not responding. MSG_CONFIGURATOR_INVALID_OPERATION_ERROR=Error : Invalid operation. MSG_CONFIGURATOR_OPERATION_FAILED_ERROR=Error : Operation failed. MSG_CONFIGURATOR_EXCEPTION_ERROR=Error : Unknown exception. MSG_OS_LD_INIT=This is an OS drive. This virtual drive cannot be initialized. VD_WR_POLICY_BAD_BBU=Use Write Through for failed or missing battery ENCLOSURE_ID_TEXT=ID BADBBU_PRE=Yes BADBBU_ABS=No PROPERTY_BADBBUPOLICY_TEXT=Write Through for failed/missing battery MSG_EXTERNAL_LUNCH_TIMEOUT=Login failed : Due to timeout! MSG_CLEAR_FOREIGN_CONFIG_SUCCESS=Foreign Configuration Cleared Successfully ! PHDRIVE_TEXT_DRIVE=Drive PHDRIVE_TEXT_DRIVE_UNCONFIGURED= - Unconfigured PHDRIVE_TEXT_DRIVE_CONFIGURED= - Configured MSG_LDINIT_REFRSH_VD=VD list is not updated! Do you want to update? #################################################################### # IMAGE FILE NAMES # #################################################################### LABEL_TEMPERATURE_ICON=temperature.jpg LABEL_FAN_ICON=fan.jpg LABEL_POWER_ICON=powersupply.jpg ENCLOSURE_BOX_IMAGE=enclosurebox.jpg UNCONF_ENCLPD_IMAGE=enclosurepd.jpg ONLINE_ENCLPD_IMAGE=onlinepd_in_enclosure.jpg OFFLINE_ENCLPD_IMAGE=offlinepd_in_enclosure.jpg EMPTYSLOT_ENCL_IMAGE=emptyslot_in_enclosure.jpg HOTSPARE_ENCLPD_IMAGE=hotsparepd_in_enclosure.jpg REBUILD_ENCLPD_IMAGE=rebuildpd_in_enclosure.gif DEFAULT_HOST_IMAGE=host.jpg DEGRADED_HOST_IMAGE=degraded.jpg FAILED_HOST_IMAGE=failed.jpg LSI_LOGO_IMAGE=lsi_logo.jpg SELECTED_HOST_IMAGE=selected_host.jpg RIGHT_ARROW=rightarrow.jpg LEFT_ARROW=leftarrow.jpg ARRAY_IMAGE=array.jpg PHDRIVE_IMAGE=phdrive.jpg ADAPTER_IMAGE=controller_standard.jpg PORT_IMAGE=port.jpg HOTSPARE_IMAGE=hotspare.jpg UNCONFIG_IMAGE=unconfig.jpg ENCLOSURE_IMAGE=enclosure.jpg VOLUME_IMAGE=volume.jpg AUTO_CONF=wrench.jpg MANUAL_CONF=hammer.jpg GUIDED_CONF=guided.jpg RECON_INSERT_IMG=plus.jpg RECON_DELETE_IMG=Scissor.jpg RECON_CHANGE_IMG=thread_chaser.jpg RECON_DOWN_IMG=arrowdown.jpg RECON_UP_IMG=arrowup.jpg UNCONFIGURED_IMAGE=unconfig.jpg PHDRIVE_SCSI_IMAGE=scsidrive.jpg NEEDS_ATTENTION_IMAGE=needatn.jpg PHDRIVE_FC_IMAGE=phdrive.jpg PHDRIVE_SAS_IMAGE=sasdrive.jpg BANNER_SMALL_IMAGE=small_banner.jpg PHDRIVE_SATA_IMAGE=satadrive.jpg DEGRADED_IMAGE=degraded.jpg LDRIVE_IMAGE=volume.jpg SERVER_IMAGE=server.jpg BBU_IMAGE=battery.jpg BANNER_IMAGE=banner.jpg REBUILD_IMAGE=pdrebuild.jpg FAILED_IMAGE=failed.jpg PARTIAL_DEGRADED_IMAGE=partialdegraded.png TAPE_IMAGE=tape.jpg CDROM_IMAGE=cdrom.jpg PHDRIVE_SAS_IMAGE_UNCFG=sasdrive_uncfg.jpg PHDRIVE_SATA_IMAGE_UNCFG=satadrive_uncfg.jpg PHDRIVE_SCSI_IMAGE_UNCFG=scsidrive_uncfg.jpg UNCONFIGURED_IMAGE_UNCFG=unconfig_uncfg.jpgDownload Driver Pack
After your driver has been downloaded, follow these simple steps to install it.
Expand the archive file (if the download file is in zip or rar format).
If the expanded file has an .exe extension, double click it and follow the installation instructions.
Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.
Find the device and model you want to update in the device list.
Double-click on it to open the Properties dialog box.
From the Properties dialog box, select the Driver tab.
Click the Update Driver button, then follow the instructions.
Very important: You must reboot your system to ensure that any driver updates have taken effect.
For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.