PROCESS: 1)Please verify in which channel you installed the HDD. This program can only change the HDD mode parameters on channel zero. If you use the multi-channel card (Ex.2ch-RAID card), please move the target HDD to channel zero. 2)Insert "Mode parameter tool" into the floppy drive. 3)Turn on system and boot-up the program. 4)After starting the program the following menu will appear, please select the number that matches your drive type. IBM DCAS-34330 : 1 [Enter] (IBM 4GB for Spruce1) IBM DDRS-34560 (Single End) : 2 [Enter] (IBM 4GB for Sprucr2) IBM DDRS-34560 (LVD) : 3 [Enter] (Not use) IBM DDRS-39130 (Single End) : 4 [Enter] (IBM 9GB for Spruce2) IBM DDRS-39130 (LVD) : 5 [Enter] (IBM 9GB for ALL MAGNIA) IBM DNES-318350 : 6 [Enter] (IBM 18GB for Spruce3 and Maple1A) FUJITSU M2954 : 7 [Enter] (Not use) FUJITSU MAB3045 : 8 [Enter] (Fujitsu 4GB for Maple and Cypress) FUJITSU MAB3091 : 9 [Enter] (Fujitsu 9GB for Maple and Cypress) SEAGATE ST39102 : 10 [Enter] (Seagate 9GB for Maple and Cypress and Spruce3) For example, if you use the DCAS-34330 drive, please select "1" to start the program. Example:(DCAS-34330) Serching... 00:00:00 IBM DCAS-34330W S65A Detect!! 00:01:00 IBM DDRS-34560W S97B Missmatch!! 00:03:00 IBM DDRS-39130W S97B Missmatch!! 00:05:00 FUJITSU M2954E-512 2755 Missmatch!! 00:06:00 FUJITSU MAB3045SC 2703 Missmatch!! 00:07:00 FUJITSU MAB3091SC 2703 Missmatch!! 00:08:00 Seagate ST39102LC 0004 Missmatch!! MODE SELECT execute Are you ready? (y/n): 5)if the program finds the correct drive, enter "y" 6)Please check the status Target 00:00:00 IBM DCAS-34330W S65A OK!! MODE SELECT exeucute completed. This program gets the current parameters from target drive. 7)If the screen appears with the following massage, press any key. Press any key to continue... 8)Once you press a key, the following message will appear on screen again: Example:(DCAS-34330) Serching... 00:00:00 IBM DCAS-34330W S65A Detect!! 00:01:00 IBM DDRS-34560W S97B Missmatch!! 00:03:00 IBM DDRS-39130W S97B Missmatch!! 00:05:00 FUJITSU M2954E-512 2755 Missmatch!! 00:06:00 FUJITSU MAB3045SC 2703 Missmatch!! 00:07:00 FUJITSU MAB3091SC 2703 Missmatch!! 00:08:00 Seagate ST39102LC 0004 Missmatch!! MODE SELECT execute Are you ready? (y/n): 9)If the program found the correct drive, enter "y" Please check the status: Target 00:00:00 IBM DCAS-34330W S65A OK!! MODE SELECT execute completed. This program modifies the target parameters of the target drive.Download Driver Pack
After your driver has been downloaded, follow these simple steps to install it.
Expand the archive file (if the download file is in zip or rar format).
If the expanded file has an .exe extension, double click it and follow the installation instructions.
Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.
Find the device and model you want to update in the device list.
Double-click on it to open the Properties dialog box.
From the Properties dialog box, select the Driver tab.
Click the Update Driver button, then follow the instructions.
Very important: You must reboot your system to ensure that any driver updates have taken effect.
For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.