** ** VIA Rhine Family Fast Ethernet Adapter ** ** PXERPL BOOTROM ** ** v2.40 Feb ,2005 ** Introduction: ============= PXERPL combines PXE with RPL and users can choose one they want from bootstrap menu. In general, RPL needs Netware or Windows NT server 3.5/3.51/4.0 to do its boot server, and PXE usually use in Windows NT/2000/XP/2005 and Linux. The PXE of this PXERPL is built by PXE SDK 2.0 build 082, so it full supports PXE Specification 2.1. Contents of the Subdirectory: ============================= PXERPL.TXT This file. PXERPL.LOM The bootrom binary file for Lan On Motherboard. PXERPL.NIC The bootrom binary file for Network Interface Card. FETND.DOS The NDIS2 driver require for remote boot. FETND.CNF The configuration file require for remote boot. PROTOCOL.INI The configuration file require for remote boot. Installation: ============= Before starting the installation process, make sure that the adapter is properly installed and configured. You can use the diagnostic program (A:\DIAG.EXE) to make sure your connection with the network is correct. PXERPL EEPROM Options ------------------- After POST of BIOS, BootROM will waiting a short time to change boot method. If user strike <Shift-Tab> key, PXERPL will show some advenced menu and you have 2 options in it: Boot Protocol Boot Option And if no <Shift-Tab> key, PXERPL will boot according EERPOM value. please refer EEPROM.doc to get more informatin about their configuration. 1. Boot Protocol There are 2 options, PXE and RPL. You can specify which will be booted. 2. Boot Option There are 4 options: Network First, Then Local Local First, Then Network Local Only According BIOS A. Network First, Then Local This option is chosen to boot network by hooking INT 19. Since INT 19 is booting vector, our device is always chosen to boot regardless of IPL priority. B. Local First, Then Network This option is chosen to boot from network by hooking INT 18h. Since INT 18h is boot recovery vector, so only after other local devices with higher IPL prioirty failed to boot successfully then we may boot. C. Local Only This option is chosen to boot from local devices, not to boot from network. D. According BIOS This option is chosen to boot network by PnP/BEV. Whether to boot or not according IPL priority. The proiority for IPL devices is configurable by the user by editing the IPL Priority in BIOS Setup. If user enter any option and press <F4> to save, PXERPL will write back into EEPROM. Pressing <ESC> will ignore any modification and booting according EEPROM setting. RPL Setup Procedure: -------------------- 1. The BOOTROM installation procedures are identical in Windows NT Server 3.5, 3.51, 4.0. First, install the Remoteboot Service on the NT Server: Choose "Control Panel\Network\Add Software" and select "Remoteboot Service", follow the screen instruction to install. 2. Use "File Manager" in NT Server 3.5, 3.51 or "Windows Explorer" in NT Server 4.0 to share the following directory: \windows\rpl\rpl\rplfiles, suppose \windows is your Windows NT directory. 3. Copy all the MS-DOS 6.22 files as follow: attrib -s -h -r c:\io.sys attrib -s -h -r c:\msdos.sys copy c:\io.sys c:\windows\rpl\rplfiles\binfiles\dos622 copy c:\msdos.sys c:\windows\rpl\rplfiles\binfiles\dos622 copy c:\dos622\*.* c:\windows\rpl\rplfiles\binfiles\dos622 attrib +s +h +r c:\io.sys attrib +s +h +r c:\msdos.sys 4. Copy the NDIS2 driver for "PCI Fast Ethernet Adapter" as follow: copy a:\bootrom\fetnd.dos c:\windows\rpl\bblock\ndis md c:\windows\rpl\bblock\netbeui\fetnd copy a:\bootrom\fetnd.cnf c:\windows\rpl\bblock\netbeui\fetnd copy a:\bootrom\protocol.ini c:\windows\rpl\bblock\netbeui\fetnd 5. Run RPLCMD to add a bblock record for the adapter as follow: net start remoteboot ;run in MSDOS prompt rplcmd ;Follow the example below to enter data Adapter Boot Config Profile Service Vendor Wksta [Quit] V Add Del Enum: A VendorName=xxxxxx ;upper 6 digits of your adapter's ethernet ID VendorComment=xx...x ;type your vendor string. optional. Adapter Boot Config Profile Service Vendor Wksta [Quit] B Add Del Enum:A BootName=DOSV1 VendorName=xxxxxx ;upper 6 digits of your adapter's ethernet ID BbcFile=BBLOCK\NETBEUI\FETND\FETND.CNF BootCommet=xx...x ;optional string WindowsSize=0 Adapter Boot Config Profile Service Vendor Wksta [Quit] C Add Del Enum:A ConfigName=DOS622V1 BootName=DOSV1 DirName=DOS DirName2=DOS622 FitShared=FITS\DOS622.FIT FitPersonal=FITS\DOS622P.FIT ConfigComment=DOS 6.22 FETND DirName3= ;press "Enter" DirName4= ;press "Enter" Adapter Boot Config Profile Service Vendor Wksta [Quit] Q 6. Run "Control Panel\Services", select "Remoteboot Service" and change the "Startup" option to "Automatic". Now reboot NT Server, remoteboot service will be started automatically. 7. Run "Remoteboot Manager" from "Administrative Tools" a. Choose "Remoteboot\New Profile.." to create a Profile Name according to the DOS 6.22 FETND configuration. b. Choose "Remoteboot\New Workstation.." to create a Workstation Name according to the profile name and your Adapter Ethernet ID. 8. Now the remoteboot server is ready, boot your workstation with "BOOTROM plug in PCI Fast Ethernet Adapter", then you can access the NT Server from your workstation.Download Driver Pack
After your driver has been downloaded, follow these simple steps to install it.
Expand the archive file (if the download file is in zip or rar format).
If the expanded file has an .exe extension, double click it and follow the installation instructions.
Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.
Find the device and model you want to update in the device list.
Double-click on it to open the Properties dialog box.
From the Properties dialog box, select the Driver tab.
Click the Update Driver button, then follow the instructions.
Very important: You must reboot your system to ensure that any driver updates have taken effect.
For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.