OEMSETUP.INF Driver File Contents (dr_xp_6.45_3.zip)

;  -- This file contains descriptions of the MegaRAID family 
;             of RAID Controllers
;
; Copyright © 2001, LSI Logic Corp.,
[version]
Signature="$Windows NT$"
Class=SCSIAdapter
ClassGUID={4D36E97B-E325-11CE-BFC1-08002BE10318}
Provider=%LSI%
CatalogFile=MRAID32.cat
DriverVer= 08/02/2004,6.45.32


     
[DestinationDirs]
DefaultDestDir = 12 ; DIRID_DRIVERS


[ControlFlags]
;
; Exclude the following PnP devices from Select Device list.
;
ExcludeFromSelect = PCI\VEN_101E&DEV_9010 
ExcludeFromSelect = PCI\VEN_8086&DEV_1960&SUBSYS_0431101E 
ExcludeFromSelect = PCI\VEN_101E&DEV_9060 
ExcludeFromSelect = PCI\VEN_8086&DEV_1960&SUBSYS_0438101E 
ExcludeFromSelect = PCI\VEN_8086&DEV_1960&SUBSYS_0466101E 
ExcludeFromSelect = PCI\VEN_8086&DEV_1960&SUBSYS_0467101E
ExcludeFromSelect = PCI\VEN_8086&DEV_1960&SUBSYS_0490101E 

ExcludeFromSelect = PCI\VEN_101E&DEV_1960&SUBSYS_0471101E
ExcludeFromSelect = PCI\VEN_101E&DEV_1960&SUBSYS_0493101E
ExcludeFromSelect = PCI\VEN_101E&DEV_1960&SUBSYS_0475101E

ExcludeFromSelect = PCI\VEN_8086&DEV_1960&SUBSYS_0762101E 

ExcludeFromSelect = PCI\VEN_1011&DEV_0046&SUBSYS_0489101E 
ExcludeFromSelect = PCI\VEN_8086&DEV_B555&SUBSYS_0489101E 

ExcludeFromSelect = PCI\VEN_101E&DEV_1960&SUBSYS_0494101E 
ExcludeFromSelect = PCI\VEN_8086&DEV_1960&SUBSYS_0494101E 

ExcludeFromSelect = PCI\VEN_101E&DEV_1960&SUBSYS_0503101E 
ExcludeFromSelect = PCI\VEN_8086&DEV_1960&SUBSYS_0503101E 
ExcludeFromSelect = PCI\VEN_101E&DEV_1960&SUBSYS_0511101E

ExcludeFromSelect = PCI\VEN_1000&DEV_1960&SUBSYS_05181000 
ExcludeFromSelect = PCI\VEN_1000&DEV_1960&SUBSYS_05201000 
ExcludeFromSelect = PCI\VEN_1000&DEV_1960&SUBSYS_A5201000
ExcludeFromSelect = PCI\VEN_101E&DEV_1960&SUBSYS_0522101E 
ExcludeFromSelect = PCI\VEN_1000&DEV_1960&SUBSYS_05221000 
ExcludeFromSelect = PCI\VEN_1000&DEV_0407&SUBSYS_05311000
ExcludeFromSelect = PCI\VEN_1000&DEV_0407&SUBSYS_05321000

ExcludeFromSelect = PCI\VEN_1000&DEV_0408&SUBSYS_00011000
ExcludeFromSelect = PCI\VEN_1000&DEV_0408&SUBSYS_00021000
ExcludeFromSelect = PCI\VEN_1000&DEV_0408&SUBSYS_10651734
ExcludeFromSelect = PCI\VEN_1000&DEV_0408&SUBSYS_004D1025

ExcludeFromSelect = PCI\VEN_8086&DEV_1960&SUBSYS_10C6103C
ExcludeFromSelect = PCI\VEN_8086&DEV_1960&SUBSYS_10C7103C
ExcludeFromSelect = PCI\VEN_8086&DEV_1960&SUBSYS_10CC103C
ExcludeFromSelect = PCI\VEN_8086&DEV_1960&SUBSYS_10CD103C
ExcludeFromSelect = PCI\VEN_101E&DEV_1960&SUBSYS_60E7103C
ExcludeFromSelect = PCI\VEN_101E&DEV_1960&SUBSYS_60E8103C


ExcludeFromSelect = PCI\VEN_1000&DEV_1960&SUBSYS_05231000
ExcludeFromSelect = PCI\VEN_1000&DEV_1960&SUBSYS_45231000
ExcludeFromSelect = PCI\VEN_1000&DEV_0407&SUBSYS_05301000

ExcludeFromSelect = PCI\VEN_1000&DEV_0409&SUBSYS_30041000
ExcludeFromSelect = PCI\VEN_1000&DEV_0409&SUBSYS_30081000

ExcludeFromSelect = PCI\VEN_1000&DEV_0407&SUBSYS_05328086
ExcludeFromSelect = PCI\VEN_1000&DEV_0407&SUBSYS_34328086
ExcludeFromSelect = PCI\VEN_1000&DEV_0407&SUBSYS_05308086

ExcludeFromSelect = PCI\VEN_1000&DEV_0408&SUBSYS_34318086
ExcludeFromSelect = PCI\VEN_1000&DEV_0408&SUBSYS_344C8086
ExcludeFromSelect = PCI\VEN_1000&DEV_0408&SUBSYS_344D8086
ExcludeFromSelect = PCI\VEN_1000&DEV_0408&SUBSYS_34498086
ExcludeFromSelect = PCI\VEN_1000&DEV_0408&SUBSYS_00028086

ExcludeFromSelect = PCI\VEN_1000&DEV_1960&SUBSYS_05238086
ExcludeFromSelect = PCI\VEN_1000&DEV_1960&SUBSYS_05208086

ExcludeFromSelect = PCI\VEN_1000&DEV_0409&SUBSYS_30088086

     
[Manufacturer]
%LSI%=LSI
%HP%=HP
%INTEL%=INTEL

     
[LSI]
;MegaRAID Enterprise 1200 (428)
%mraid428.DeviceDesc% = Mraid35x_Inst, PCI\VEN_101E&DEV_9010 

;MegaRAID 431 
%megaraid.DeviceDesc% = Mraid35x_Inst, PCI\VEN_8086&DEV_1960&SUBSYS_0431101E 

;MegaRAID Enterprise 1300 (434)
%mraid434.DeviceDesc% = Mraid35x_Inst, PCI\VEN_101E&DEV_9060 

;MegaRAID Enterprise 1400 (438) 
%mraid438.DeviceDesc% = Mraid35x_Inst, PCI\VEN_8086&DEV_1960&SUBSYS_0438101E 

;MegaRAID Express 200 (466) 
%mraid466.DeviceDesc% = Mraid35x_Inst, PCI\VEN_8086&DEV_1960&SUBSYS_0466101E 

;MegaRAID Enterprise 1500 (467) 
%mraid467.DeviceDesc% = Mraid35x_Inst, PCI\VEN_8086&DEV_1960&SUBSYS_0467101E

;MegaRAID Enterprise 1600 (471) 
%mraid471.DeviceDesc% = Mraid35x_Inst, PCI\VEN_8086&DEV_1960&SUBSYS_0471101E
%mraid471.DeviceDesc% = Mraid35x_Inst, PCI\VEN_101E&DEV_1960&SUBSYS_0471101E

;MegaRAID Express 300 (490)
%mraid490.DeviceDesc% = Mraid35x_Inst, PCI\VEN_8086&DEV_1960&SUBSYS_0490101E 

;MegaRAID Elite 1600 (493)
%mraid493.DeviceDesc% = Mraid35x_Inst, PCI\VEN_8086&DEV_1960&SUBSYS_0493101E
%mraid493.DeviceDesc% = Mraid35x_Inst, PCI\VEN_101E&DEV_1960&SUBSYS_0493101E

;MegaRAID SCSI 320-0X (530)
%mraid530.DeviceDesc% = mraid35x_Inst, PCI\VEN_1000&DEV_0407&SUBSYS_05301000 

;MegaRAID SCSI 320-1E
%mraid320-1.DeviceDesc% = mraid35x_Inst, PCI\VEN_1000&DEV_0408&SUBSYS_00011000 

;MegaRAID SCSI 320-2E
%mraid320-2.DeviceDesc% = mraid35x_Inst, PCI\VEN_1000&DEV_0408&SUBSYS_00021000 

;MegaRAID Express 000 (762)
%mraid762.DeviceDesc% = Mraid35x_Inst, PCI\VEN_8086&DEV_1960&SUBSYS_0762101E 

;MegaRAID Express 500/500LC (475)
%mraid475.DeviceDesc% = Mraid35x_Inst, PCI\VEN_8086&DEV_1960&SUBSYS_0475101E
%mraid475.DeviceDesc% = Mraid35x_Inst, PCI\VEN_101E&DEV_1960&SUBSYS_0475101E

;MegaRAID Enterprise 3000 (489)
%mraid489.DeviceDesc% = Mraid35x_Inst, PCI\VEN_1011&DEV_0046&SUBSYS_0489101E 
%mraid489.DeviceDesc% = Mraid35x_Inst, PCI\VEN_8086&DEV_B555&SUBSYS_0489101E 

;MegaRAID Elite 1650/1700 (494)
%mraid494.DeviceDesc% = Mraid35x_Inst, PCI\VEN_101E&DEV_1960&SUBSYS_0494101E 
%mraid494.DeviceDesc% = Mraid35x_Inst, PCI\VEN_8086&DEV_1960&SUBSYS_0494101E 

;MegaRAID Enterprise 1700 (503)
%mraid503.DeviceDesc% = Mraid35x_Inst, PCI\VEN_101E&DEV_1960&SUBSYS_0503101E 
%mraid503.DeviceDesc% = Mraid35x_Inst, PCI\VEN_8086&DEV_1960&SUBSYS_0503101E 

;MegaRAID i4 IDE RAID Controller (LSI Logic)
%mraid511.DeviceDesc% = mraid35x_Inst, PCI\VEN_101E&DEV_1960&SUBSYS_0511101E 

;MegaRAID 320-0
%mraidZCR.DeviceDesc% = mraid35x_Inst, PCI\VEN_1000&DEV_1960&SUBSYS_A5201000 

;MegaRAID 320-2
%mraid518.DeviceDesc% = mraid35x_Inst, PCI\VEN_1000&DEV_1960&SUBSYS_05181000 

;MegaRAID 320-1
%mraid520.DeviceDesc% = mraid35x_Inst, PCI\VEN_1000&DEV_1960&SUBSYS_05201000 

;MegaRAID SCSI 320-4X (531)
%mraid531.DeviceDesc% = mraid35x_Inst, PCI\VEN_1000&DEV_0407&SUBSYS_05311000 

;MegaRAID SCSI 320-2X (532)
%mraid532.DeviceDesc% = mraid35x_Inst, PCI\VEN_1000&DEV_0407&SUBSYS_05321000 

;MegaRAID i4133 (522)
%mraid522.DeviceDesc% = mraid35x_Inst, PCI\VEN_101E&DEV_1960&SUBSYS_0522101E 
%mraid522.DeviceDesc% = mraid35x_Inst, PCI\VEN_1000&DEV_1960&SUBSYS_05221000 

;MegaRAID SATA 6
%mraid523.DeviceDesc% = mraid35x_Inst, PCI\VEN_1000&DEV_1960&SUBSYS_05231000 

;MegaRAID SATA 4
%mraid4523.DeviceDesc% = mraid35x_Inst, PCI\VEN_1000&DEV_1960&SUBSYS_45231000

;MegaRAID SATA 300-4X
%mraidSATA300-4X.DeviceDesc% = mraid35x_Inst, PCI\VEN_1000&DEV_0409&SUBSYS_30041000

;MegaRAID SATA 300-8X
%mraidSATA300-8X.DeviceDesc% = mraid35x_Inst, PCI\VEN_1000&DEV_0409&SUBSYS_30081000

;MegaRAID PCI Express(TM) ROMB
%mraidPCIEROMB.DeviceDesc% = mraid35x_Inst, PCI\VEN_1000&DEV_0408&SUBSYS_10651734
%mraidPCIEROMB.DeviceDesc% = mraid35x_Inst, PCI\VEN_1000&DEV_0408&SUBSYS_004D1025

[HP]
%netraid3si.DeviceDesc% = Mraid35x_Inst, PCI\VEN_8086&DEV_1960&SUBSYS_10C6103C
%netRaid.DeviceDesc%    = Mraid35x_Inst, PCI\VEN_8086&DEV_1960&SUBSYS_10C7103C
%netRaid.DeviceDesc%    = Mraid35x_Inst, PCI\VEN_8086&DEV_1960&SUBSYS_10CC103C
%netraid1si.DeviceDesc% = Mraid35x_Inst, PCI\VEN_8086&DEV_1960&SUBSYS_10CD103C
;HP 475
%netraid1M.DeviceDesc%  = Mraid35x_Inst, PCI\VEN_101E&DEV_1960&SUBSYS_60E7103C
;HP 493
%netraid2M.DeviceDesc%  = Mraid35x_Inst, PCI\VEN_101E&DEV_1960&SUBSYS_60E8103C


[INTEL]
;Intel's Chilito-2 (u320-2X)
%Intelu3202X.DeviceDesc% = Mraid35x_Inst, PCI\VEN_1000&DEV_0407&SUBSYS_05328086
%Intelu3202X.DeviceDesc% = Mraid35x_Inst, PCI\VEN_1000&DEV_0407&SUBSYS_34328086

;Intelu3202EX
%Intelu3202EX.DeviceDesc% = Mraid35x_Inst, PCI\VEN_1000&DEV_0408&SUBSYS_00028086

;Intel Sawtell (SATA-6)
%IntelSata6.DeviceDesc% = Mraid35x_Inst, PCI\VEN_1000&DEV_1960&SUBSYS_05238086 

;Intel® RAID Controller SRCU41L
%IntelSRCU41L.DeviceDesc% = Mraid35x_Inst, PCI\VEN_1000&DEV_1960&SUBSYS_05208086 

;Intel® RAID Controller SRCZCRX
%IntelSRCZCRX.DeviceDesc% = Mraid35x_Inst, PCI\VEN_1000&DEV_0407&SUBSYS_05308086

;Intel® RAID Controller SRCS28X
%IntelSRCS28X.DeviceDesc% = Mraid35x_Inst, PCI\VEN_1000&DEV_0409&SUBSYS_30088086

;Intel® RAID Controller SROMBU42E
%IntelSROMBU42E.DeviceDesc% = Mraid35x_Inst, PCI\VEN_1000&DEV_0408&SUBSYS_34318086
%IntelSROMBU42E.DeviceDesc% = Mraid35x_Inst, PCI\VEN_1000&DEV_0408&SUBSYS_34498086
%IntelSROMBU42E.DeviceDesc% = Mraid35x_Inst, PCI\VEN_1000&DEV_0408&SUBSYS_344C8086
%IntelSROMBU42E.DeviceDesc% = Mraid35x_Inst, PCI\VEN_1000&DEV_0408&SUBSYS_344D8086



[Mraid35x_Inst]
CopyFiles = @Mraid35x.sys
     
[Mraid35x_Inst.Services]
AddService = Mraid35x, %SPSVCINST_ASSOCSERVICE%, Mraid35x_Service_Inst,Miniport_EventLog_Inst

[Mraid35x_Service_Inst]
ServiceType    = %SERVICE_KERNEL_DRIVER% 
StartType      = %SERVICE_BOOT_START% 
ErrorControl   = %SERVICE_ERROR_NORMAL% 
ServiceBinary  = %12%\Mraid35x.sys
LoadOrderGroup = SCSI Miniport
AddReg         = pnpsafe_pci_addreg
     
;************************************************************* 
;The EventLog entries are the same for all SCSI miniports. 
[Miniport_EventLog_Inst]
AddReg = Miniport_EventLog_AddReg
     
[pnpsafe_pci_addreg]
HKR, "Parameters\PnpInterface", "5", 0x00010001, 0x00000001
HKR, "Parameters\Device", "NumberOfRequests", 0x00010001, 0x000000BD
HKR, "Parameters\Device", "CreateInitiatorLU", 0x00010001, 0x00000001
HKLM,"System\CurrentControlSet\Services\Disk","TimeOutValue",0x00010001,0x0000003C

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_1960&subsys_10C6103C,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_1960&subsys_10C6103C,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_1960&subsys_10C7103C,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_1960&subsys_10C7103C,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_1960&subsys_10CC103C,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_1960&subsys_10CC103C,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_1960&subsys_10CD103C,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_1960&subsys_10CD103C,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_101E&dev_1960&subsys_60E7103C,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_101E&dev_1960&subsys_60E7103C,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_1960&subsys_0762101E,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_1960&subsys_0762101E,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_101E&dev_1960&subsys_60E8103C,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_101E&dev_1960&subsys_60E8103C,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1011&dev_0046&subsys_0489101E,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1011&dev_0046&subsys_0489101E,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_B555&subsys_0489101E,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_B555&subsys_0489101E,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_1960&subsys_0503101E,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_1960&subsys_0503101E,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_1960&subsys_0438101E,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_1960&subsys_0438101E,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_1960&subsys_0466101E,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_1960&subsys_0466101E,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_1960&subsys_0467101E,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_1960&subsys_0467101E,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_1960&subsys_0490101E,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_1960&subsys_0490101E,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_101E&dev_1960&subsys_0493101E,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_101E&dev_1960&subsys_0493101E,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_101E&dev_1960&subsys_0511101E,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_101E&dev_1960&subsys_0511101E,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_101E&dev_1960&subsys_0471101E,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_101E&dev_1960&subsys_0471101E,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_101E&dev_1960&subsys_0475101E,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_101E&dev_1960&subsys_0475101E,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_101E&dev_1960&subsys_0477101E,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_101E&dev_1960&subsys_0477101E,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_101E&dev_1960&subsys_0494101E,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_101E&dev_1960&subsys_0494101E,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_1960&subsys_0494101E,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_8086&dev_1960&subsys_0494101E,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_101E&dev_1960&subsys_0503101E,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_101E&dev_1960&subsys_0503101E,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_1960&subsys_05181000,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_1960&subsys_05181000,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_1960&subsys_05201000,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_1960&subsys_05201000,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_101E&dev_1960&subsys_0522101E,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_101E&dev_1960&subsys_0522101E,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_1960&subsys_05221000,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_1960&subsys_05221000,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0407&subsys_05311000,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0407&subsys_05311000,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0407&subsys_05321000,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0407&subsys_05321000,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_1960&subsys_A5201000,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_1960&subsys_A5201000,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_1960&subsys_05231000,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_1960&subsys_05231000,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_1960&subsys_45231000,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_1960&subsys_45231000,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0407&subsys_05301000,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0407&subsys_05301000,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0408&subsys_00011000,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0408&subsys_00011000,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0408&subsys_00021000,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0408&subsys_00021000,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0409&subsys_30041000,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0409&subsys_30041000,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0409&subsys_30081000,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0409&subsys_30081000,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0408&subsys_10651734,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0408&subsys_10651734,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0408&subsys_004D1025,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0408&subsys_004D1025,Service,,%Service%


HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0407&subsys_05328086,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0407&subsys_05328086,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0408&subsys_00028086,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0408&subsys_00028086,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_1960&subsys_05238086,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_1960&subsys_05238086,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_1960&subsys_05208086,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_1960&subsys_05208086,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0407&subsys_05308086,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0407&subsys_05308086,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0407&subsys_34328086,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0407&subsys_34328086,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0409&subsys_30088086,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0409&subsys_30088086,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0408&subsys_34318086,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0408&subsys_34318086,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0408&subsys_344C8086,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0408&subsys_344C8086,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0408&subsys_34498086,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0408&subsys_34498086,Service,,%Service%

HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0408&subsys_344D8086,ClassGUID,,%ClassGUID%
HKLM,SYSTEM\CurrentControlSet\Control\CriticalDeviceDataBase\pci#ven_1000&dev_0408&subsys_344D8086,Service,,%Service%


[Miniport_EventLog_AddReg]
HKR,,EventMessageFile,%REG_EXPAND_SZ%,%%SystemRoot%%\System32\IoLogMsg.dll 
HKR,,TypesSupported,%REG_DWORD%,7

[SourceDisksNames]
1 = %SOURCE_DISK%,\Mraid35x.sys,,

[SourceDisksFiles]
Mraid35x.SYS = 1,,11136,,,,,,

[Strings]
;------------------MegaRAID----------------------------
LSI = "LSI Logic Corp.,"
megaraid.DeviceDesc = "MegaRAID RAID Controller RAID Controller"
mraid466.DeviceDesc = "MegaRAID Express 200 RAID Controller"
mraid490.DeviceDesc = "MegaRAID Express 300 RAID Controller"
mraid762.DeviceDesc = "MegaRAID Express 000 RAID Controller"
mraid475.DeviceDesc = "MegaRAID Express 500/500LC RAID Controller"
mraid493.DeviceDesc = "MegaRAID Elite 1600 RAID Controller"
mraid494.DeviceDesc = "MegaRAID Elite 1650/1700 RAID Controller"
mraid428.DeviceDesc = "MegaRAID Enterprise 1200 RAID Controller"
mraid434.DeviceDesc = "MegaRAID Enterprise 1300 RAID Controller"
mraid438.DeviceDesc = "MegaRAID Enterprise 1400 RAID Controller"
mraid467.DeviceDesc = "MegaRAID Enterprise 1500 RAID Controller"
mraid471.DeviceDesc = "MegaRAID Enterprise 1600 RAID Controller"
mraid503.DeviceDesc = "MegaRAID Enterprise 1700 RAID Controller"
mraid489.DeviceDesc = "MegaRAID Enterprise 3000 RAID Controller"
mraidZCR.DeviceDesc = "MegaRAID SCSI 320-0 RAID Controller"
mraid520.DeviceDesc = "MegaRAID SCSI 320-1 RAID Controller"
mraid518.DeviceDesc = "MegaRAID SCSI 320-2 RAID Controller"
mraid532.DeviceDesc = "MegaRAID SCSI 320-2X RAID Controller"
mraid531.DeviceDesc = "MegaRAID SCSI 320-4X RAID Controller"
mraid530.DeviceDesc = "MegaRAID SCSI 320-0X RAID Controller"
mraid320-1.DeviceDesc = "MegaRAID SCSI 320-1E RAID Controller"
mraid320-2.DeviceDesc = "MegaRAID SCSI 320-2E RAID Controller"
mraid511.DeviceDesc = "MegaRAID i4 IDE RAID Controller" 
mraid522.DeviceDesc = "MegaRAID i4133 RAID Controller"
mraid523.DeviceDesc = "MegaRAID SATA 150-6 RAID Controller"
mraid4523.DeviceDesc = "MegaRAID SATA 150-4 RAID Controller"
mraidSATA300-4X.DeviceDesc = "MegaRAID SATA 300-4X RAID Controller"
mraidSATA300-8X.DeviceDesc = "MegaRAID SATA 300-8X RAID Controller"
mraidPCIEROMB.DeviceDesc = "MegaRAID PCI Express(TM) ROMB"

Service = "Mraid35x"
ClassGUID = "{4D36E97B-E325-11CE-BFC1-08002BE10318}"


;------------------HP----------------------------------
HP="Hewlett Packard"
netraid3si.DeviceDesc = "HP NetRAID-3Si"
NetRaid.DeviceDesc    = "Integrated HP NetRAID"
netraid1si.DeviceDesc = "HP NetRAID-1Si"
netraid1M.DeviceDesc  = "HP NetRAID-1M RAID Controller"
netraid2M.DeviceDesc  = "HP NetRAID-2M RAID Controller"

;------------------MegaRAID----------------------------
INTEL = "Intel(R) Corporation"
Intelu3202X.DeviceDesc  = "Intel(R) RAID Controller SRCU42X"
Intelu3202EX.DeviceDesc = "Intel(R) RAID Controller SRCU42E"
IntelSata6.DeviceDesc = "Intel (R) RAID Controller SRCS16" 
IntelSRCZCRX.DeviceDesc = "Intel(R) RAID Controller SRCZCRX"
IntelSRCS28X.DeviceDesc = "Intel(R) RAID Controller SRCS28X"
IntelSROMBU42E.DeviceDesc = "Intel(R) RAID Controller SROMBU42E"
IntelSRCU41L.DeviceDesc	= "Intel(R) RAID Controller SRCU41L"

SOURCE_DISK         = "MegaRAID 2001 RAID Driver"     
;******************************************* 
;Handy macro substitutions (non-localizable) 
SPSVCINST_ASSOCSERVICE = 0x00000002
SERVICE_KERNEL_DRIVER  = 1
SERVICE_BOOT_START     = 0
SERVICE_ERROR_NORMAL   = 1
REG_EXPAND_SZ          = 0x00020000
REG_DWORD              = 0x00010001
Download Driver Pack

How To Update Drivers Manually

After your driver has been downloaded, follow these simple steps to install it.

  • Expand the archive file (if the download file is in zip or rar format).

  • If the expanded file has an .exe extension, double click it and follow the installation instructions.

  • Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.

  • Find the device and model you want to update in the device list.

  • Double-click on it to open the Properties dialog box.

  • From the Properties dialog box, select the Driver tab.

  • Click the Update Driver button, then follow the instructions.

Very important: You must reboot your system to ensure that any driver updates have taken effect.

For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.

server: web1, load: 1.04