FTSATA2.INF Driver File Contents (Promise_FastTrak_TX2200_TX4200_579_TX2300_TX4300_779_Series_Driver.zip)

;  Copyright (C) 1998-2003 Promise Technology,Inc

[Version]
Signature="$Chicago$"
Class=SCSIAdapter
ClassGuid={4D36E97B-E325-11CE-BFC1-08002BE10318}
Provider=%PROMISE%
CatalogFile=ftsata2.cat
DriverVer=10/07/2004, 1.00.0.31

[SourceDisksNames]
1 = %DISKNAME1%,,,,
2 = %DISKNAME2%,,,,

[SourceDisksFiles]
ftsata2.sys = 1
bb-run.sys = 1
dontgo.sys = 1
ftutil2.dll = 1

[DestinationDirs]
DefaultDestDir	= 12
CacheDll = 11;

;[DriverFiles_9X]

[DriverFiles_NT_2K]
ftsata2.sys,,,0x20

[DriverFiles_XP]
ftsata2.sys,,,0x20

[FilterDriverFiles]
bb-run.sys,,,0x20
dontgo.sys,,,0x20

[CacheDll]
ftutil2.dll,,,0x20

[Manufacturer]
%Promise%=Promise,NTx86.5.1

[Promise]
%PCI\VEN_105A&DEV_3571.DeviceDesc% = FasttrakPCI_571 , PCI\VEN_105A&DEV_3571
%PCI\VEN_105A&DEV_3519.DeviceDesc% = FasttrakPCI_571 , PCI\VEN_105A&DEV_3519
%PCI\VEN_105A&DEV_3574.DeviceDesc% = FasttrakPCI_571 , PCI\VEN_105A&DEV_3574
%PCI\VEN_105A&DEV_3570.DeviceDesc% = FasttrakPCI_571 , PCI\VEN_105A&DEV_3570
%PCI\VEN_105A&DEV_3515.DeviceDesc% = FasttrakPCI_571 , PCI\VEN_105A&DEV_3515
%PCI\VEN_105A&DEV_3577.DeviceDesc% = FasttrakPCI_571 , PCI\VEN_105A&DEV_3577&SUBSYS_B0031458
%Promise_Raid_ControllerDesc%=NODRV,SCSI\ProcessorPromise_RAID_Console____

[Promise.NTx86.5.1]
%PCI\VEN_105A&DEV_3571.DeviceDesc% = FasttrakPCI_571_XP , PCI\VEN_105A&DEV_3571
%PCI\VEN_105A&DEV_3519.DeviceDesc% = FasttrakPCI_571_XP , PCI\VEN_105A&DEV_3519
%PCI\VEN_105A&DEV_3574.DeviceDesc% = FasttrakPCI_571_XP , PCI\VEN_105A&DEV_3574
%PCI\VEN_105A&DEV_3570.DeviceDesc% = FasttrakPCI_571_XP , PCI\VEN_105A&DEV_3570
%PCI\VEN_105A&DEV_3515.DeviceDesc% = FasttrakPCI_571_XP , PCI\VEN_105A&DEV_3515
%PCI\VEN_105A&DEV_3577.DeviceDesc% = FasttrakPCI_571_XP , PCI\VEN_105A&DEV_3577&SUBSYS_B0031458
%Promise_Raid_ControllerDesc%=NODRV,SCSI\ProcessorPromise_RAID_Console____
 
[NODRV]
AddReg=NODRV_AddReg
;

[NODRV.Services]
;
; this is blank to just allow the install to succeed
;
AddService = , %SPSVCINST_ASSOCSERVICE%   ; null service install

;; Win9x install sections
;;
;[FasttrakPCI_571]

;; Windows NT4.0 and Windows 2000 install sections
;;
[FasttrakPCI_571.NTx86]
Copyfiles=DriverFiles_NT_2K, FilterDriverFiles, CacheDll
AddReg   = DontGo.AddReg 
Reboot

[FasttrakPCI_571.NTx86.Services]
AddService = ftsata2, 2, FasttrakPCI_Service_Inst, Miniport_EventLog_Inst
AddService = bb-run,,FilterService_Install
AddService = dontgo,,DontGo.Service.Install

;; Windows XP install sections
;;
[FasttrakPCI_571_XP]
Copyfiles=DriverFiles_XP, FilterDriverFiles, CacheDll
AddReg   = DontGo.AddReg 
Reboot

[FasttrakPCI_571_XP.Services]
AddService = ftsata2, 2, FasttrakPCI_Service_Inst, Miniport_EventLog_Inst
AddService = bb-run,,FilterService_Install
AddService = dontgo,,DontGo.Service.Install

[FasttrakPCI_Service_Inst]
ServiceType    = 1      ; SERVICE_KERNEL_DRIVER
StartType      = 0      ; SERVICE_BOOT_START
ErrorControl   = 1      ; SERVICE_ERROR_NORMAL
ServiceBinary  = %12%\ftsata2.sys
LoadOrderGroup = "SCSI Miniport"
AddReg         = pnpsafe_pci_addreg, ftsata_cache_addreg, ftsata_Device_addreg 

[FilterService_Install]
DisplayName	= Promise driver accelerator
ServiceType	= 1
StartType	= 0
ErrorControl	= 0
ServiceBinary	= %12%\bb-run.sys
LoadOrderGroup  = "Filter"

[DontGo.Service.Install]
DisplayName    = %DontGo_Service_Desc%
ServiceType    = 1
StartType      = 0
ErrorControl   = 1
ServiceBinary  = %12%\DontGo.sys
LoadOrderGroup = "PnP Filter"

; supporting P&P on the PCI(5) bus.
[pnpsafe_pci_addreg]
HKR, "Parameters\PnpInterface", "5", 0x00010001, 0x00000001

;*************************************************************
[ftsata_cache_addreg]
HKR, "Parameters\Cache", "DefSize", 0x00010001, 0x01000000
HKR, "Parameters\Cache", "Flag",0x00010001, 0x00000001
HKR, "Parameters\Cache", "WriteMode",0x00010001, 0x00000000
HKR, "Parameters\Cache", "ThreadNum",0x00010001, 0x00000010
HKR, "Parameters\Cache", "HotSpareDisable",0x00010001, 0x00000000
HKR, "Parameters\Cache", "LongBurstDisable",0x00010001, 0x00000001
HKR, "Parameters\Cache", "NCQTCQEnable",0x00010001, 0x00000000
HKLM,"SOFTWARE\Microsoft\Windows\CurrentVersion\Run","ftutil2",,"rundll32.exe ftutil2.dll,SetWriteCacheMode"

[ftsata_Device_addreg]
HKR, "Parameters\Device", "NumberOfRequests",0x00010001, 0x0000003f
HKLM,System\CurrentControlSet\Services\Disk,TimeOutValue,%REG_DWORD%,0x0000003c

[DontGo.AddReg]
HKLM, System\CurrentControlSet\Control\Class\{4d36e967-e325-11ce-bfc1-08002be10318}, UpperFilters, 0x00010008, DontGo

[DontGo.DelReg]
HKLM, System\CurrentControlSet\Control\Class\{4d36e967-e325-11ce-bfc1-08002be10318}, UpperFilters, 0x00018002, DontGo

[NODRV_AddReg]

;*************************************************************
;The NT EventLog entries are the same for all SCSI miniports.
[Miniport_EventLog_Inst]
AddReg = Miniport_EventLog_AddReg

[Miniport_EventLog_AddReg]
HKR,,EventMessageFile,%REG_EXPAND_SZ%,"%%SystemRoot%%\System32\IoLogMsg.dll;%%SystemRoot%%\System32\Drivers\ftsata2.sys"
HKR,,TypesSupported,%REG_DWORD%,7

;[IOS]
;HKR,,DevLoader,,*IOS
;HKR,,DontLoadIfConflict,,"Y"

;[WIN98.REG]
;HKR,,PortDriver,,98DriverName.mpd

[strings]
DISKNAME1="Promise FastTrak 571/519/579 Driver Diskette"
DISKNAME2="Windows system"
Promise="Promise Technology"

PCI\VEN_105A&DEV_3571.DeviceDesc="Windows Promise FastTrak TX2200 (tm) Controller"
PCI\VEN_105A&DEV_3519.DeviceDesc="Windows Promise FastTrak TX4200 (tm) Controller"
PCI\VEN_105A&DEV_3574.DeviceDesc="Windows Promise FastTrak 579 (tm) Controller"
PCI\VEN_105A&DEV_3570.DeviceDesc="Windows Promise FastTrak TX2300 (tm) Controller"
PCI\VEN_105A&DEV_3515.DeviceDesc="Windows Promise FastTrak TX4300 (tm) Controller"
PCI\VEN_105A&DEV_3577.DeviceDesc="Windows Promise FastTrak 779 (tm) Controller"
Promise_Raid_ControllerDesc= "Windows Promise RAID Console SCSI Processor Device" 

DontGo_Service_Desc = "Promise Removable Disk Control Driver"

REG_EXPAND_SZ=0x00020000
REG_DWORD=0x00010001

SPSVCINST_ASSOCSERVICE = 0x00000002
Download Driver Pack

How To Update Drivers Manually

After your driver has been downloaded, follow these simple steps to install it.

  • Expand the archive file (if the download file is in zip or rar format).

  • If the expanded file has an .exe extension, double click it and follow the installation instructions.

  • Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.

  • Find the device and model you want to update in the device list.

  • Double-click on it to open the Properties dialog box.

  • From the Properties dialog box, select the Driver tab.

  • Click the Update Driver button, then follow the instructions.

Very important: You must reboot your system to ensure that any driver updates have taken effect.

For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.

server: web2, load: 1.80