README.TXT Driver File Contents (655_All_Drivers.zip)

    Release Notes for TranXit(TM)  Version 2.1
    Copyright (C) Puma Technology, 1994 - 1995
  
    This document contains information that supplements the 
    user's guide, on-line help, and accompanying software.
  
    CONTENTS
  
      I.  The TranXit Install Program
                1.  Modifications to Your SYSTEM.INI File
     II.  Installing TranXit with Remote Install
    III.  Trouble Shooting
                1.  Parallel Cable Connection
                2.  Serial Cable Connection
                3.  Infrared Connection
                4.  Windows For Workgroups/16550 UART
     IV.  Print Redirector
                1.  Settings for Printers Under Windows 3.1/3.11
                2.  Setting Up Direct IR Printing in Windows 95
      V.  Other Issues
                1.  Clipboard Transfer
                2.  Synchronization
                3.  Direct Infrared Printing
                4.  Problems with TranXit2 and other programs
                    doing modem transfers
                5.  Problems with TranXit and the Microsoft Windows 95 IrDA Driver
                6.  Long Filename Support
                7.  Polled Parallel Mode

       _________________________________________________________________
  
    I. The TranXit Install Program
  
    1. Modifications to .INI Files

    The following changes will be made to your .INI files if you install
    TranXit using all the default conditions during the install program.

      a. Additions to SYSTEM.INI 
      
               [386Enh] section:  device=C:\TRANXIT\PCOMM2.386
                                              device=C:\TRANXIT\PUMAIR.386
                                              device=C:\TRANXIT\pumairtp.386 (IBM Think Pads only)

               [boot] section:    drivers=printpro

               [drivers] section: printpro=c:\tranxit\printpro.drv

      b. Addition to PROGMAN.INI
      
               [Groups] section:  Groupn=C:\WINDOWSDIR\TRANXIT.GRP

      c. Additions to WIN.INI 
      
               [ports] section:   TRANXIT2.PRN=
    

    Note: If you install TranXit on your computer more than once, previous
                instances of PCOMM2.386 will be commented out of SYSTEM.INI.  
                Only the most recent installation directory will be reflected in 
                SYSTEM.INI.

    _________________________________________________________________


    II.  Installing TranXit with Remote Install

    To install TranXit on a remote computer that does not have
    a floppy drive, you can use the Remote Install option from
    the Options menu.  (The Remote Install menu item may be greyed
    if there is already a version of TranXit on the remote computer,
    and it is running.)

    When using the Remote Install feature, the remote computer must
    NOT be running SHARE.EXE or any power management utilities.  This 
    may cause transmission failure during the install process.  The 
    remote computer must also be operating from the DOS prompt.  
    If you are running Windows(TM), you must exit Windows.  A Windows 
    DOS box cannot be used.

    If you experience transmission problems during remote install, the 
    transfer baud rate may be adjusted in TRANXIT2.INI. In the [Advanced]
    section modify the following line:

              RemoteInstallBaud=57600

    Valid baud rates are: 2400, 4800, 9600, 19200, 38400, 57600, 115200. Try
    using a slower baud rate when you encounter transmission errors.
    
    _________________________________________________________________


    III.  Trouble Shooting

    1.  Parallel Cable Connection

    If you have configured TranXit to communicate over a parallel cable, 
    and you do not get a New Window button (this is enabled when a 
    connection is established), check the following:

              a.  Make sure the that both the local and remote computers have 
                  selected a parallel cable connection in Connection/Setup.

              b.  If the connection is intermittent, make sure the cable is securely
                  fastened to the parallel port.

              c.  Verify that there are no conflicts with other hardware devices such
                  as sound cards or network adapters.  The default IRQ setting for many 
                  sound cards is IRQ 7.  This is also the IRQ that is used for 
                  communication over LPT1.  Consult your adapter documentation for 
                  changing the default IRQ on these boards.

              d.  If you have selected LPT2, the default IRQ on the I/O communication
                  adapter may not be set to IRQ 5.  Try selecting IRQ 7 from the
                  Change Connection Settings in the Connection Setup dialog box, or
                  consult the I/O adapter documentation for changing the IRQ for
                  LPT2 to IRQ 5.  If you have a bus mouse, it may be set to IRQ 5.
                  If the mouse freezes after configuring TranXit for LPT2, there is
                  an IRQ conflict. Consult your mouse hardware documentation for 
                  changing the default IRQ.

              e.  If your computer has more than one parallel port, make sure the 
                  cable is attached to the correct port.  Don't laugh, this is 
                  a common oversight.

              f.  When connecting to a slower computer, Pentium to 386, you may need
                  to start TranXit on the slower computer first.

              g.  The parallel cable must be LapLink(R) compatible and have male 
                  DB-25 connectors at both ends. If you are not using a LapLink 
                  parallel cable, make sure the cable is configured with the 
                  following pin connections:
  
                            25 Pin             25 Pin 
                            -------            -------
                            Pin 2     (---)    Pin 15 
                            Pin 3     (---)    Pin 13 
                            Pin 4     (---)    Pin 12 
                            Pin 5     (---)    Pin 10 
                            Pin 6     (---)    Pin 11 
                            Pin 15    (---)    Pin 2 
                            Pin 13    (---)    Pin 3 
                            Pin 12    (---)    Pin 4 
                            Pin 10    (---)    Pin 5 
                            Pin 11    (---)    Pin 6 
                            Pin 25    (---)    Pin 25 (Ground-Ground) 
  

    2.  Serial Cable Connection

    If you have configured TranXit to communicate over a serial cable, and 
    you do not get a New Window button (this is enabled when a connection 
    is established), check the following:

              a.  Make sure the that both the local and remote computers have selected
                  the proper serial cable connection in Connection/Setup. The baud 
                  rate setting must be the same on both systems.

              b.  If the connection is intermittent, make sure the cable is securely
                  fastened to the serial port.

              c.  Verify that there are no conflicts with other serial devices.  
                  Conflicts will occur when serial devices are sharing interrupts 
                  (IRQ's).  In a standard configuration (if you computer is 
                  equipped with 4 serial ports), COM1 and COM3 will share IRQ 4, 
                  and COM2 and COM4 share IRQ 3. If your mouse is on COM1 and you're 
                  trying to connect TranXit over COM3, there will be an IRQ conflict.  
                  In this case, your mouse may freeze and you will not make a 
                  connection with the remote computer.

              d.  If your computer has more than one serial port, make sure the cable
                  is attached to the correct port.  

              e.  When connecting to a slower computer, Pentium to 386, you may need
                  to start TranXit on the slower computer first.

              f.  The serial cable must be LapLink compatible, and can be either a 
                  9-pin or a 25-pin female connector on both ends. If you are not 
                  using a LapLink serial cable, make sure the cable is configured 
                  with the following pin connections:
  
                            9 Pin           25 Pin              25 Pin          9 Pin 
                            ------          -------             -------         ------
                            Pin 5           Pin 7     (---)     Pin 7           Pin 5 
                            (Ground-Ground) 
                            Pin 3           Pin 2     (---)     Pin 3           Pin 2 
                            (Transmit-Receive) 
                            Pin 7           Pin 4     (---)     Pin 5           Pin 8 
                            (RTS - CTS) 
                            Pin 6           Pin 6     (---)     Pin 20          Pin 4 
                            (DSR - DTR) 
                            Pin 2           Pin 3     (---)     Pin 2           Pin 3 
                            (Receive-Transmit) 
                            Pin 8           Pin 5     (---)     Pin 4           Pin 7 
                            (CTS - RTS) 
                            Pin 4           Pin 20    (---)     Pin 6           Pin 6 
                            (DTR - DSR) 

              g.  Some notebook computers use the Windows loadable device driver 
                  POWER.DRV for power conservation. If you are experiencing trouble
                  connecting to a remote computer, and you have tried all of the 
                  above steps, set the Power Management list box setting in the 
                  Power Control Panel Applet to "Standard" or "Off."


    3.  Infrared Connection

    If you have configured TranXit to communicate with an infrared 
    connection, and you do not get a New Window button (this is enabled when 
    a connection is established), check the following:

              a.  Make sure the that both the local and remote computers have selected 
                  the proper infrared connection in Setup/Connection.

              b.  There must be no obstacles blocking the line of sight between
                  the infrared adapters.
    
              c.  The adapters should be placed away from any light or 
                  electromagnetic source. These can include such items
                  as wireless headphones, halogen desk lamps, and even
                  computer monitors.

              d.  When connecting to a slower computer, Pentium to 386, you may need
                  to start TranXit on the slower computer first.

              e.  Some notebook computers use the Windows loadable device driver 
                  POWER.DRV for power conservation. If you are experiencing trouble
                  connecting to a remote computer, and you have tried all of the 
                  above steps, set the Power Management list box setting in the 
                  Power Control Panel Applet to "Standard" or "Off."

              f.  If the message "Error establishing connection. Please verify 
                  the port settings in connection setup." appears, it is possible
                  that the infrared device could not be initialized properly. Restart
                  TranXit after checking the following:

                            -   Make sure the correct infrared model has been selected
                                in connection setup.
                            -   If using an infrared dongle connected to the serial port, 
                                make sure the cable is securely fastened to the serial port. 
                                If the dongle requires an external power source, insure 
                                the power source is properly attached.
                  

    4.  Windows For Workgroups/16550 UART

    Some computers equipped with the 16550/16550a UART chip may experience hangs when
    loading TranXit or running setup/connection within TranXit.  If you are using
    Windows For Workgroups, you must get an updated version of SERIAL.386.  This VxD
    will reside in the Windows SYSTEM directory ( i.e., C:\WINDOWS\SYSTEM\SERIAL.386).
    The update is available on CompuServe or from Microsoft's technical support.


   _________________________________________________________________

   IV.  Print Redirector

   1. Settings for Printers Under Windows 3.1/3.11

   To use Print Redirection you must turn off "Print Manager" and
   "Fast Printing Direct to Port" in Windows 3.1 or 3.11.

   These steps must be done on both the host and the remote computer:
   
              a.  Open the Control Panel in the Main Group
              b.  Open the Printers icon
              c.  Your default printer should be highlighted.  If it is not, click
                  on its name once.
              d.  At the bottom of this dialog box, look at the check box marked
                  "Use Print Manager".  If this is checked, click in the box to
                  uncheck it.
              e.  Now click on the Connect Button.
              f.  At the bottom of this dialog box, look at the check box marked
                  "Fast Printing Direct to Port". If this is checked, click in the 
                  box to uncheck it.
              g.  Click Close on this dialog box and on the main Printers dialog box.
              h.  Close the Control Panel.
     
    2.  Setting Up Direct IR Printing in Windows 95

              a.  Start TranXit2
              b.  Click the Print Redirector tab or choose PrintRedirector from the 
                  Tab menu
              c.  From the PrintPro menu, select "Printer Connection".  The 
                  Windows 95 Printers system folder will open.
              d.  The Printers folder contains a printer icon for each printer
                  you have configured.  Select the icon matching your infrared
                  printer by clicking on it ONCE.
              e.  Click on the right mouse button, and select "Properties" from
                  the pop-up menu, or select "File" from the Printers folder menu
                  and then select "Properties".
              f.  You will now see a set of tabbed property sheets.  
                  Click on the Details tab.
              g.  In the middle of this sheet, click on "Add Port".
              h.  You will now see a dialog box.  Click on the "Other"
                  radio button, and select "Local Port".
              i.  In the Port Name box, type "TRANXIT2.PRN". Click OK.
              j.  If you receive an error message saying that "TRANXIT2.PRN already
                  exists", ignore it.  Instead, click on the down arrow next to the
                  box under "Print to the following port" and select the listing
                  for "TRANXIT2.PRN (unknown local port)".
              k.  Make sure that "TRANXIT2.PRN (unknown local port)" appears in
                  the middle of the property sheet. Then click on the "OK" button 
                  at the bottom of the tabbed sheets.
              l.  With this printer still selected, select File from the Printers
                  folder menu, and then verify that "Set As Default" is selected
                  for this printer.  This can also be done by using the right
                  mouse button to bring up the popup menu.
              m.  Close the Printers folder.
    
    _________________________________________________________________


    V.  Other Issues

    1.  Clipboard Transfer

    When transferring graphics images from one computer's clipboard to 
    another, keep in mind that one of the clipboard formats 
    used is the DDB (Device Dependent Bitmap).  As the name implies this 
    format is dependent on the type of video display being used. 
    Problems may develop when images are transferred from a 16-color 
    display to a 256-color display or vice-versa.  A warning message 
    will appear when the format may not transfer correctly from one 
    computer's clipboard to another.

    If you are running TranXit 2.0, connected with a remote computer running
    TranXit 1.x, clipboard functions will be disabled.

    2.  Synchronization

    When synchronizing files between two computers, and selecting to copy 
    only files that are newer, for instance, TranXit compares the time stamps
    on the files on both computers and copies the files with the latest time 
    stamp.  This may cause the wrong files to be transferred if the internal 
    clock in the computers are not in sync.

    If you have selected synchronize options to copy only files that are newer,
    or older, be aware of time differences between the two computers. The following
    scenario may cause unwanted results when the file C:\BIN\FRED.BIN exists
    on both computers:

              -   Local Computer -- Date 1/1/91, Time 1:00:00.
              -   Remote Computer -- Date 1/1/91, Time 2:00:00.
              -   Modify FRED.BIN on the local computer (time stamp 1:05:00).  
                  This is now the newer file of the two files, although, the time
                  stamp on the file is older than the one on the remote computer.
              -   Synchronize  C:\BIN [Local]  ((  C:\BIN [Remote].
              -   Select options, copy only newer files.
              -   Begin synchronization.

              FRED.BIN, from the remote computer, will overwrite FRED.BIN on the 
              local computer because the time is newer (2:00:00). If the times
              on the two systems were the same, there would be no overwrite of
              the file.  

              TranXit will display a warning message when the first new remote
              window is opened if the time difference between the computers
              is greater than 1 hour.

    3.  Direct Infrared Printing

    In order for direct infrared printing to operate correctly, the following
    must be true:

              a. The item "Use Print Manager" in Control Panel / Printers, must
                 be turned off.

              b. The item "Fast Printing Direct to Port" in Control Panel / Printers
                 / Connect, must be turned off.

              c. The mode, in TranXit2 / Setup / Connection... / Setup 
                 Connection..., must be set to "variable".

    4.  Problems with TranXit2 and other programs doing modem transfers
    
    When TranXit enables a link (e.g. parallel, serial, or infrared) to 
    establish a connection to a remote system, it is possible on some 
    systems to encounter difficulties when downloading data with another 
    program via a modem. This can happen even without the TranXit user 
    interface loaded if the PrintPro print redirection feature is 
    enabled. If you experience problems with modem downloads disable all 
    connections in Connection Setup in the TranXit user interface for the 
    duration of the download.

    5.  Problems with TranXit and the Microsoft Windows 95 IrDA Driver
    
    When the Microsoft Windows 95 IrDA Driver loads, it uses the COM port
    hardware to which the infrared adapter hardware is attached. As long 
    as the Microsoft Windows 95 IrDA Driver is loaded, TranXit can not 
    use the infrared adapter. To enable TranXit to use the infrared 
    hardware, disable the Microsoft Windows 95 IrDA Driver as follows:

    a. Start the Microsoft "Infrared Monitor" application. This 
       application can be started by double-clicking on the Infrared icon 
       in the Windows 95 Control Panel or by clicking on the Infrared 
       icon on the right side of the Windows 95 Task Bar near the clock.

    b. In the "Options" property sheet, make sure the checkbox titled
       "Enable infrared communication" is not checked and that the "Status"
       property sheet shows "Infrared communication has been disabled".

    c. Click OK to close the Infrared Monitor.
   
    To re-enable the Microsoft Windows 95 IrDA Driver after using 
    TranXit, ensure that the "Enable infrared communication" checkbox is 
    checked in the "Options" property sheet and that the "Status" property 
    sheet shows the infrared bitmap is active in the "Infrared Monitor" 
    application. 

    6.  Long Filename Support

    Windows 95 long filenames are not visible from TranXit PowerPro's
    file window.

    If both computers are running TranXit PowerPro and Windows 95, when
    copying files locally or between two computers, the Windows 95 long
    file names are preserved. When copying files from a computer running
    Windows 3.1 to a computer running Windows 95, you are prompted to select
    the target computers file name if the existing file has a long file name.
    You are given the option of retaining the Windows 95 long file name or
    use the standard Windows 3.1 (DOS 8.3 naming convention) file name. If
    you select the standard Windows 3.1 file name, the long file name is
    destroyed. If File Replace confirmations are disabled, the long file name
    will be used, and you will not be prompted to select the target file
    name.
              
    7.  Polled Parallel Mode

    Use Polled mode when the IRQ is in use or not known. Polled mode does
    not use an IRQ. Polled mode can be used on one or both computers. Polled
    mode transfers may be slower.

    _________________________________________________________________


    TranXit and TranXit2 are trademarks of Puma Technology, Inc.
    All other product names are trademarks or registered trademarks of 
    their respective holders.

Download Driver Pack

How To Update Drivers Manually

After your driver has been downloaded, follow these simple steps to install it.

  • Expand the archive file (if the download file is in zip or rar format).

  • If the expanded file has an .exe extension, double click it and follow the installation instructions.

  • Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.

  • Find the device and model you want to update in the device list.

  • Double-click on it to open the Properties dialog box.

  • From the Properties dialog box, select the Driver tab.

  • Click the Update Driver button, then follow the instructions.

Very important: You must reboot your system to ensure that any driver updates have taken effect.

For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.

server: web5, load: 2.00