QLA40XX iSCSI HBA STOR Miniport Driver for Windows
Release Notes
June 20, 2007
This software license applies only to QLogic customers.
QLogic Corporation.
All rights reserved.
Table of Contents
1. Version
2. Changes
3. Bug Fixes
4. Known Issues
5. Additional Information
6. History
7. Trademarks
8. Notices
9. Contacting Support
1. Version
These release notes describe the changes, fixes, known issues, and
release details that apply to iSCSI HBA STOR miniport driver, version
2.1.4.18.
2. Changes
The following changes have been made to the iSCSI HBA STOR
miniport driver between versions 2.1.4.12 and 2.1.4.13.
Hardware Support
* Adhered to Subsystem Id document v2.2r
(NOTE: Microsoft requires all HBAs be supported in both x86 and x64).
Software/Driver
None
Industry Standards Compliance
N/A
3. Bug Fixes
The following fixes have been made to the iSCSI HBA STOR
miniport driver between versions 2.1.4.12 and 2.1.4.13.
2.1.4.13 QL - 06/20/07
* Closed ER55027/issue 373076: SHM 5.0.0.32: Using IPv6 static link
local address iSNS fails to enable.
4. Known Issues
2.1.4.13 QL - 06/20/07
* iSNS registration's portal address will be same version as iSNS server's
portal address version.
* Windows Vista hibernation may hang if user enables /debug option due to
an unhandled assert, 2003 OK
5. Additional Information
None
6. History
2.1.4.12 QL - 04/17/07
* Adhered to Subsystem Id document v2.2r
(NOTE: Microsoft requires all HBAs be supported in both x86 and x64).
* Added support for the following devices (supported platforms):
PCI\VEN_1077&DEV_4032&SUBSYS_01071077 (x64, x86)
PCI\VEN_1077&DEV_4032&SUBSYS_014f1077 (x64, x86)
PCI\VEN_1077&DEV_4032&SUBSYS_01581077 (x64, x86)
PCI\VEN_1077&DEV_4032&SUBSYS_036C1014 (x64, x86)
PCI\VEN_1077&DEV_4032&SUBSYS_036E1014 (x64, x86)
PCI\VEN_1077&DEV_4032&SUBSYS_03721014 (x64, x86)
* Flashing firmware may fail while also doing session reestablishment.
* Reregister with iSNS server before session times out.
* Register with iSNS after DHCP completes.
* Fixed NVRAM access error on some PCI-X 133MHz by inserting delays.
* Bug check running perfmon on adapter with > 16 sessions.
* Fixed watchdog timeout of DDB_CHANGE_AEN that results in bad HBA reset.
* Added FW debug support
* Queue depth based on number of LU's in session.
* Qlogic performance counters.
* Always allow initiator name change.
* iSCSI Async Msg with Sense (06/3F/0E) will trigger SCSI Bus rescan.
* Support iSNS IPv6 based server.
* Support IPv6 iSDMAPI.
2.1.3.4 QL - 06/29/06
* Performance increase against LUN mapped targets.
* Fixed bug check due to shared buffer data corruption.
2.1.3.3 QL - 03/02/06
* Fixed driver failure to start after MS port driver hotfix was installed.
2.1.3.2 QL - 02/14/06
* Added wait time during initialization while link is down if SAN booting.
2.1.3.1 QL - 02/09/06
* Fixed performance issue caused by removing cap on MaximumTransferLength.
2.1.3.0 QL - 12/21/05
* Removed support for the following devices:
PCI\VEN_1077&DEV_4022&SUBSYS_01261077
* Added support for the following devices:
PCI\VEN_1077&DEV_4032&SUBSYS_014C1077
PCI\VEN_1077&DEV_4032&SUBSYS_014F1077
PCI\VEN_1077&DEV_4032&SUBSYS_01521077
PCI\VEN_1077&DEV_4032&SUBSYS_01561077
PCI\VEN_1077&DEV_4032&SUBSYS_01581077
* Add support for multiple session between I-T.
* Add support for ISP4032.
* Fixed pause after adapter reset when SAN booting.
* Fixed resource locking issue when SAN booting and running with ql40xnet NDIS.
* Add reboot retry logic to account for reboot failures when SAN booting and running with ql40xnet NDIS.
* Fixed reporting of HBA IP address with MPIO.
2.1.2.0 QL - 10/04/05
* Added support for the following devices:
PCI\VEN_1077&DEV_4022&SUBSYS_02E21014
PCI\VEN_1077&DEV_4022&SUBSYS_03221014
PCI\VEN_1077&DEV_4022&SUBSYS_02CF1014
PCI\VEN_1077&DEV_4022&SUBSYS_02D01014
* Added single driver support for ISP4010 and ISP4022
* Added support for IPSEC offload on ISP4010
* Added BusChange after reestablishment due to async logout
* Added Restore Factory Defaults IOCTL
* Added new interrupt coalescing IOCB type
* Added new performance wmi class
* Added support for targets that report first level logical unit addressing method
* Updated event log to match FC
* Fixed timer bug for non DPC operation
* Fixed issue where ZIO could not be disabled via GUI.
* Fixed issue where if iSNS is enabled when no local IP address exists, initialization fails.
* Fixed issue where iSNS could not be enabled/disabled on a per port basis.
* Fixed bug where reapply nonpersistent DDB after HBA reset was changing entry state
* Fixed chip reset sequencing bug with NDIS driver seen when user changes Ethernet frame size on NDIS
* Fixed chip reset sequencing bug with NDIS driver seen when user disables both NDIS ports quickly on a two port adapter
* Fixed case where driver takes too long to fail over in MPIO configuration due to local link down
7. Trademarks
QLogic, the QLogic logo, QLA, SANbox, SANsurfer, and SANblade are
registered trademarks of QLogic Corporation.
SANtrack and SAN Express are trademarks of QLogic Corporation.
All other brand and product names are trademarks or registered
trademarks of their respective owners.
8. Notices
Information furnished in this document is believed to be accurate and
reliable. However, QLogic Corporation assumes no responsibility for
its use, nor for any infringements of patents or other rights of
third parties which may result from its use. QLogic Corporation
reserves the right to change product specifications at any time
without notice. Applications described in this document for any of
these products are only for illustrative purposes. QLogic Corporation
makes no representation nor warranty that such applications are
suitable for the specified use without further testing or
modification. QLogic Corporation assumes no responsibility for any
errors that may appear in this document.
9. Contacting Support
Please feel free to contact your QLogic approved reseller or QLogic
Technical Support at any phase of integration for assistance. QLogic
Technical Support can be reached by the following methods:
Web: http://support.qlogic.com
North America Contact Information
Email: support@qlogic.com
Phone: (952) 932-4040
Support contact information for other regions of the world is
available at the QLogic website: http://support.qlogic.com
© Copyright 2007. All rights reserved worldwide. QLogic, the QLogic
logo, and the Powered by QLogic logo are registered trademarks of
QLogic Corporation. All other brand and product names are trademarks
or registered trademarks of their respective owners.
Download Driver Pack
After your driver has been downloaded, follow these simple steps to install it.
Expand the archive file (if the download file is in zip or rar format).
If the expanded file has an .exe extension, double click it and follow the installation instructions.
Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.
Find the device and model you want to update in the device list.
Double-click on it to open the Properties dialog box.
From the Properties dialog box, select the Driver tab.
Click the Update Driver button, then follow the instructions.
Very important: You must reboot your system to ensure that any driver updates have taken effect.
For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.