This README file contains the latest information about the
IBM TotalStorage™ FAStT Storage Server controller firmware
version 05.40.15.00 for FAStT700/FAStT900/FAStT600 .
Refer to the IBM TotalStorage™ Support Web Site or CD for the
IBM FAStT Storage Manager version 8.4x (Intel or Unix Operating
Systems) Installation and Support Guides for firmware and NVSRAM
download instructions.
For other related publications (refer to Related Publications in the
installation and support guide) and the latest information and
updated readme file.
Last Update: 07/30/2004
Products Supported:
---------------------------------------------------
| | Machine Type | Model |
|-----------|--------------|------------------------|
| FAStT 900 | 1742 | 90X , 90U |
|-----------|--------------|------------------------|
| FAStT 700 | 1742 | 1RX, 1RU |
|-----------|--------------|------------------------|
| FAStT 600 | 1722 | 60U , 60X |
---------------------------------------------------
Note:
The controller firmware and NVSRAM files that are part of this
IBM TotalStorage™ FAStT release should not be loaded into FAStT
storage servers connected to FAStT EXP100 drive expansion
enclosures. For FAStT storage servers connected to FAStT EXP100
drive expansion enclosures, the controller firmware and NVSRAM
files that are part of the IBM TotalStorage™ FAStT Storage Server
controller firmware version 05.41.xx.x release must be used instead.
=======================================================================
CONTENTS
--------
1.0 Overview
2.0 Change History
3.0 Installation and Setup Instructions
4.0 Configuration Information
5.0 Unattended Mode
6.0 Web Sites and Support Phone Number
7.0 Trademarks and Notices
8.0 Disclaimer
=======================================================================
1.0 Overview
--------------
The IBM TotalStorage™ FAStT Storage Server controller firmware version
05.40.15.00 release includes the FAStT Storage Server controller
firmware and NVSRAM files for upgrading the following IBM machine
types - 1722 (models 60X and 60U), 1742 (all models).
The IBM TotalStorage FAStT Storage Manager version 8.4x Installation
and Support Guide for Intel-based Operating System Environments or
the IBM TotalStorage FAStT Storage Manager version 8.4x Installation
and Support Guide for AIX, HP-UX and Solaris are available on IBM's
Support Web Site as a downloadable Portable Document Format (PDF) file.
In addition, IBM FAStT Copy Services premium features - FlashCopy,
VolumeCopy and Remote Mirror - are options purchased separately. The
Copy Services premium features require a minimum FAStT storage server
controller firmware installed.
------------------------------------------------------------------
| Premium Feature | Required controller firmware version |
|--------------------------|---------------------------------------|
| FlashCopy | 05.00.04.xx or higher |
|--------------------------|---------------------------------------|
| VolumeCopy | 05.40.xx.xx or higher |
|--------------------------|---------------------------------------|
| Remote Mirror | 05.20.0x.xx or higher |
------------------------------------------------------------------
The FAStT storage partitioning premium feature is standard on all
IBM FAStT storage subsystems with the exception of the IBM FAStT600
(machine type 1722 with Standard option) storage subsystem. Please
contact IBM Marketing representatives or IBM resellers if you want
to purchase the IBM FAStT storage partitioning premium feature option
for it. The Turbo option of the IBM FAStT600 is shipped with the IBM
FAStT storage partitioning premium feature enabled (8 partitions).
The IBM FAStT Storage Manager controller firmware version 05.40.xx.xx is
a purchase upgrade for IBM machine types 1722 and 1742 with controller
firmware version 05.3x.xx.xx and earlier installed. Please contact your
IBM service representatives or IBM resellers for purchasing info. This
version 8.4 upgrade of IBM FAStT Storage Manager software has controller
firmware for IBM machine types 1722-60X/60U (with Turbo or Standard
option), 1742-1RX/1RU and 1742-90X/90U only. The FAStT Storage Controller
firmware 05.40.xx.xx for this release is not available for IBM machine
types 3542, 3552, or 1722 6LU (single controller). However, the host
software of IBM FAStT Storage Manager 8.4x will manage all FAStT storage
server with the controller firmware 04.00.02.xx or newer.
But, any new features and updates that are introduced in this FAStT
Storage Manager version 8.4x will not be available for any FAStT storage
server controllers without the controller firmware version 05.40.xx.xx installed.
Refer to the IBM Support Web Site for the latest Firmware and
NVSRAM files for the IBM FAStT Storage Subsystems.
http://www.ibm.com/storage/support/fastt
=======================================================================
1.1 Limitations
---------------------
1. Storage Manager prompts you for a password if all hard disk
drives are removed from the storage subsystem.
After removing all drives from a storage subsystem (or not powering
on drives and only the controller), the IBM FAStT Storage Manager
software will prompt you for a password when trying to start the
software or trying to perform protected operations. Any password
entered will fail.
Password information is stored on a reserved area of each hard disk
drive on the storage subsystem. Each drive stores a mirrored copy of
the password data. When there are no drives in the storage
subsystem, the storage management software does not find the password
data when you attempt password protected operations. Add one drive to
the storage subsystem and retry the operation.
Since the RAID controller unit should not be powered on until the
expansion units are attached and powered on, this should be done by
powering off the RAID controller unit, properly attaching all
expansion units (with drives installed), to the RAID controller unit
and powering them on, and then powering the RAID controller unit back
on. At this point the storage subsystems can be re-discovered and
managed using the IBM FAStT Storage Manager 8.2 software.
2. Auto LUN/Array Transfer is not enable for,IBM AIX and SUN Solaris OS's.
If a controller fails over arrays to the alternate
controller and the failed controller is replaced and brought back online,
the arrays do not automatically transfer to the preferred controller.
This must be done manually by selecting the redistributing arrays menu
option in the storage subsystem window of the IBM FAStT storage manager
client program.
3. Display issues when using 256 color settings. A brownish hash
pattern is displayed on the windows and in online help when running
in 256 color mode. Run the Storage Manager 8 application in a higher
display mode.
4. The FAStT Storage Management dialog windows may be displayed
cropped without the vertical and horizontal scroll bars. Just move
the mouse pointer over the edge of the window until the mouse pointer
change to window resize pointer, left click and hold to grip the
window edge to resize it.
5. If you get "Error 21 - The Operation cannot complete because a
... is in progress" error when you issue a Subsystem Management
command from the IBM FAStT Storage Manager Client, the command may be
cached. If the command is cached, the IBM FAStT Storage Manager
Client will run the command as soon as the controller resources are
available. Wait for at least ten minutes and check to see whether the
command has been run. If not, re-attempt the command.
6. If the controller in the IBM FAStT Storage Server with firmware
05.3x.xx.xx is connected to a SAN with more than 64 host connections
per controller port that can log into the controllers, one must
either use the switch zoning function or rearrange the SAN
connections so that only the maximum number of host connections can
be seen and log into the controller. The FAStT Storage Subsystem
FAStT900, FAStT700 (IBM machine type 1742) have two ports per controller -
one per minihub slot. The FAStT Storage FAStT600 (IBM machine type 1722)
has two ports per controller.
7. The IBM FAStT Storage Server hardware and software is designed to
have redundant paths from the host system to ensure the availability
of storage. However, it is possible to connect a single host adapter
from the host system to one of the controller minihubs and then
connect this minihub to the minihub of the other controller. This
configuration will create a FC-AL loop between the host adapter and
the two IBM FAStT Storage Server controllers and no redundant path to
the host system. When you connect the two minihubs together, always
connect the "IN" port of one minihub to the "OUT" port of the other
minihub or vice versa. Do not connect the "IN" port of one to the
"IN" port of the other minihub or the "OUT" port of one minihub to
the "OUT" port of the other minihub.
8. When creating a Remote Mirror of a base volume the following
restriction applies. First, you have created a snapshot of a base
volume and the base volume is receiving I/O. Second, you decide to
create a mirror relationship, using the base volume as the primary
volume in the mirrored pair. As you create the mirror relationship,
the snapshot volume is failed. The work around is to stop I/O to
the base volume while you are creating the mirror relationship.
Alternatively, if the mirror relationship is created before creating
the snapshot volume, this will not happen.
9. Only logical drives that are configured as "Basic Disks" in the
Windows Disk Management folder can have Flashcopy made. The
Flashcopy of a logical drive configured as "Dynamic Disk" type
will always failed by the FAStT storage server when it is
added to the host server.
10. The FAStT Storage Manager version 8.4x does not support Veritas DMP
in Windows operating system environment. Please contact IBM
representatives or resellers for the availability of support.
=======================================================================
1.2 Enhancements
-----------------
N/A
=======================================================================
1.3 Prerequisites
------------------
N/A
=======================================================================
1.4 Dependencies
-----------------
IBM FAStT Storage Manager version 08.4x.xx.xx provides full management
support for IBM machine types 3552 and 3542 storage controllers that
have at least firmware version 04.00.02.xx, IBM Machine type 1742-900
and 1742 storage controllers that have at least firmware version
05.00.04.xx or IBM Machine type 1722 storage controllers that have at
least firmware version 05.3x.xx.xx.
The only IBM FAStT Storage Manager version 08.4x.xx.xx supported
management function on controllers with firmware version 04.xx.xx.xx
to 04.xx.01.xx is controller firmware and NVSRAM download.
=======================================================================
2.0 Change History
-----------------------------
======================================================================
2.1 Version History
-----------------------------
FAStT 700,900
-----------------
05.40.11.03 4/31/2004 Fixed a problem with cache mirroring that caused the controller
to disable the cache. The result was severe performance degradation.
05.40.11.01 4/09/2004 Second Maintenance Release of the
FAStT Storage Server controller firmware and NVSRAM.
The fix list is as follows:
75567 (CL #75479) Memory leak beginning in 5.40.xx.xx.
69629 Downloading controller firmware with offline volumes causes
unfinished download pr
69872 (CL #69467) TD_PT1086 RLS baseline date after new device
insertion is incorrect.
70891 (CL #70586) TD_PT1277 Drive size reported incorrectly for
a closed drive
71206 tray number reported incorrectly during discovery
70561 (CL #68445) C219318 CMVC 217537: Data miscompare while
doing online controller firmware downloads
70772 (CL #68894) Analysis of a MEL log shows Dacstore Scrub
is repeating on a volume group
71782 (RW #68268) (CL #67670) Can't create volume if drive sizes
are similar
72339 CMVC-hlpct_42401 Error importing a 7.3 Gig FlashCopy LUN
72676 (CL #70100) SMclient GUI reports array needs attention, but
guru reports
72712 (CL #72672) TD_PT1461 Ancient I/O during sysReboots
72768 (CL #72449) controllers repeatedly panic during M1 -> S3
FW upgrade
69052 Drives not assigned to proper loop on 2882
69204 (CL #68807) Profile not reporting correct unconfigured
capacity on volume group
- Modify the NVSRAM file to disable Cache Sync in the W2K het
host region.
05.40.06.01 12/19/2003 First Maintenance Release
05.40.03.05 9/21/2003 Initial Release
FAStT 600
-----------------
05.40.11.04 4/31/2004 Fixed a problem with cache mirroring that caused the controller
to disable the cache. The result was severe performance degradation.
05.40.11.01 4/09/2004 Second Maintenance Release of the
FAStT Storage Server controller firmware and NVSRAM.
The fix list is as follows:
75567 (CL #75479) Memory leak beginning in 5.40.xx.xx.
69629 Downloading controller firmware with offline volumes causes
unfinished download pr
69872 (CL #69467) TD_PT1086 RLS baseline date after new device
insertion is incorrect.
70105 (CL #70048) TD_PT1195 Diagnostic path to controller report
down falsely
70891 (CL #70586) TD_PT1277 Drive size reported incorrectly for
a closed drive
71206 tray number reported incorrectly during discovery
70561 (CL #68445) C219318 CMVC 217537: Data miscompare while
doing online controller firmware downloads
70772 (CL #68894) Analysis of a MEL log shows Dacstore Scrub
is repeating on a volume group
71782 (RW #68268) (CL #67670) Can't create volume if drive sizes
are similar
72339 CMVC-hlpct_42401 Error importing a 7.3 Gig FlashCopy LUN
72676 (CL #70100) SMclient GUI reports array needs attention, but
guru reports
72712 (CL #72672) TD_PT1461 Ancient I/O during sysReboots
72768 (CL #72449) controllers repeatedly panic during M1 -> S3
FW upgrade
69052 Drives not assigned to proper loop on 2882
69204 (CL #68807) Profile not reporting correct unconfigured
capacity on volume group
- Modify the NVSRAM file to disable Cache Sync in the W2K het
host region.
05.40.07.01 12/19/2003 First Maintenance Release
05.40.03.05 9/21/2003 Initial Release
======================================================================
2.2 Version 05.40.15.00 for the FAStT 700,900(All Models) 07/29/2004
A maintenance release of the FAStT Storage Server controller firmware.
The fix list is as follows:
76687 Memory fault while running sysReboot with Cluster
74957 Error encountered after Heavy Mirror Xor Traffic Phase, and RV
75268 Ancient I/0 aborted while running switch port fail (volume copy, snapshot
75682 Controller returns reservation conflict while running switch port fail test.
78203 (CL #78004) 242386 - RAID1 remained degraded after a drive pull/replac
78339 (CL #69661) Assigned drives of RAID1 VG came back as "offline"
78347 (CL #77338) Fatal vproc after replacing drive
78354 (CL #76490) C238953 - Host IO Read Errors in multiple configurations
78606 (CL #78357) disk array became unmanageable in benchmark
74117 (CL #70794) One volume never finishes reconstruction when co
74700 (CL #74488) (CL #74483) Continuous resets on Tachyon chip - 5884 contr
75324 (CL #74431) C224711 Timeout occurs on the client during a request to
75598 Panic: Assertion failed : registration = 0, file presReservableVolume.
76017 (CL #75805) Incomplete transfer of host information during v
76104 (CL #75661) Controller reboot due to ancient IO during sysRe
76109 (CL #75755) CMVC: 237648 Configuration loss of RAID 0 volume (SATA)
76181 (CL #75746) Ancient I/O (mode select I/O) during 2 second po
76269 (CL #75283) C236739 I/O error during controller offline testing with S
76727 (CL #75055) DCE operation on RAID 1 volume invalidates tray loss prote
76951 (CL #76881) IAF process hangs if multiple IAFs in progess on same volu
76965 (CL #76936) Unable to re-initiate volume group initialization after th
77501 (CL #77464) Controllers did not agree on the state of a spindown drive
77510 (CL #71143) Defragmentation fails
77555 (CL #75895) Request for ctlr resets to be blocked by ctlr du
77632 (CL #76702) Volume state not consistent between the controllers after
78048 (CL #74681) Mapping exceeds 32-lun limit for default host ty
2.3 Version 05.40.15.00 for the FAStT 600(Turbo Model) 07/29/2004
A maintenance release of the FAStT Storage Server controller firmware.
The fix list is as follows:
78203 (CL #78004) 242386 - RAID1 remained degraded after a drive pull/replac
78339 (CL #69661) Assigned drives of RAID1 VG came back as "offline"
78347 (CL #77338) Fatal vproc after replacing drive
78354 (CL #76490) C238953 - Host IO Read Errors in multiple configurations
78606 (CL #78357) disk array became unmanageable in benchmark
74117 (CL #70794) One volume never finishes reconstruction when co
74700 (CL #74488) (CL #74483) Continuous resets on Tachyon chip - 5884 contr
75324 (CL #74431) C224711 Timeout occurs on the client during a request to
76017 (CL #75805) Incomplete transfer of host information during v
76104 (CL #75661) Controller reboot due to ancient IO during sysRe
76109 (CL #75755) CMVC: 237648 Configuration loss of RAID 0 volume (SATA)
76181 (CL #75746) Ancient I/O (mode select I/O) during 2 second po
76251 (CL #76148) Controller assertion when validateCmdInfo routine calls cf
76269 (CL #75283) C236739 I/O error during controller offline testing with S
76727 (CL #75055) DCE operation on RAID 1 volume invalidates tray loss prote
76951 (CL #76881) IAF process hangs if multiple IAFs in progess on same volu
76965 (CL #76936) Unable to re-initiate volume group initialization after th
77501 (CL #77464) Controllers did not agree on the state of a spindown drive
77510 (CL #71143) Defragmentation fails
77537 (CL #75629) MEMORY FAULT in "symPrepareAltControllerInfo"
77555 (CL #75895) Request for ctlr resets to be blocked by ctlr du
77632 (CL #76702) Volume state not consistent between the controllers after
78048 (CL #74681) Mapping exceeds 32-lun limit for default host ty
=======================================================================
2.4 Code levels at time of release are as follows
-------------------------------------------------
1. Storage Controller Firmware versions:
a. FAStT 900: FW_05401500_05400500
b. FAStT 700: FW_05401500_05400500
c. FAStT 600: SNAP_05401500
2. Storage Controller NVSRAM versions:
a. FAStT 900: N1742F900R840V03
b. FAStT 700: N1742F700R840V04
d. FAStT 600: N1722F600R840V05
Refer to the following IBM TotalStorage™ Disk Storage Systems
Technical Support web site for the latest released code levels.
http://www.ibm.com/storage/support/fastt
=======================================================================
3.0 Installation and Setup Instructions
-----------------------------------------
3.1 Important: You must install the firmware update prior to downloading
the NVSRAM update.
To download firmware, do the following:
a. Open the Subsystem Management window.
b. Click Storage Subsystem => Download => Firmware.
Follow the online instructions.
To download NVSRAM, do the following:
a. Open the Subsystem Management window.
b. Click Storage Subsystem => Download => NVSRAM.
Follow the online instructions.
3.2 After the controller firmware and NVSRAM is updated, consider
checking the IBM TotalStorage™ Disk Storage Systems Technical Support
web site for the latest released drive expansion enclosure ESM
firmware and the Fibre Channel hard drive firmware.
To download drive expansion ESM firmware, do the following:
a. Open the Subsystem Management window.
b. Click Advanced => Download => Environmental(ESM) Card Firmware.
Follow the online instructions.
To download hard disk drive firmware, do the following:
a. Open the Subsystem Management window.
b. Click Advanced => Download => Drive Firmware.
Follow the online instructions.
=======================================================================
3.2 Helpful Hints
------------------
1. If you are unable to see the maximum number of drives during
Automatic Configuration, you should be able to use Manual
Configuration to select individual drives and select the maximum
number of drives allowed.
2. Depending on the storage subsystem that you have purchased, you
may have to purchase the FAST storage partitioning premium feature
option or an option to upgrade the number of supported partitions
in a storage subsystem. Please see IBM Marketing representatives
or IBM resellers for more information.
- IBM FAStT600 storage subsystem (machine type 1722): The standard
configuration does not have the FAST storage partitioning premium
enabled. Four partition, eight partition and an upgrade from four
to eight partition storage partitioning premium feature options
can be purchased.
- IBM FAStT700 storage subsystems (machine type 1742 - models 1RU and 1RX):
The standard configuration has 64 partitions storage partitioning premium
option installed. No additional storage partitioning premium feature
options can be purchased for these storage subsystems.
- IBM FAStT900 storage subsystem (machine type 1742 - models 90X and
90U): The standard configuration has 16 partition storage partitioning
premium option installed. An upgrade from 16 to 64 partition storage
partitioning premium feature option can be purchased.
=======================================================================
4.0 Configuration Information
-----------------------------
4.1 Configuration Settings
--------------------------
1. By default the IBM FAStT Storage Manager 8.4 firmware does not
automatically map logical drives if storage partitioning feature is
enabled. This means that the logical drives are not automatically
presented to host systems.
For a new installation, after creating new arrays and logical drives;
a. If your host type is not Windows NT, create a partition with your
host type and map the logical drives to this partition.
b. If your host type is Windows NT, you can map your logical drives to the
"Default Host Group" or create a partition with a NT host type.
When upgrading from previous versions of IBM FAStT Storage
Manager to version 8.4.
a. If upgrading with no partitions created and you have an operating
system other than Windows NT, you will need to create a partition with
your host type and map the logical drives from the "Default
Host Group" to this partition.
b. If upgrading with Storage Partitions and an operating system other
than Windows NT is accessing the default host group, you will need
to change the default host type. After upgrading, the default host
type is reset to Windows NT.
Refer to the IBM FAStT Storage Manager online help to learn
more about creating storage partitions and changing host types.
2. When you are configuring IBM machine type 1722, 1742, 3542 or 3552
storage subsystems as boot devices, contact IBM support for supported
configurations and instructions for configuring LUNs in the IBM
storage subsystems as boot devices.
3. Running script files for specific configurations. Apply the
appropriate scripts to your subsystem based on the instructions you
have read in the publications or any instructions in the operating
system readme file. A description of each script is shown below.
- SameWWN.scr: Setup RAID controllers to have the same World Wide
Names. The World Wide Names (node) will be the same for each
controller pair. The NVSRAM default sets the RAID controllers to have
the same World Wide Names.
- DifferentWWN.scr: Setup RAID controllers to have different World
Wide Names. The World Wide Names (node) will be different for each
controller pair. The NVSRAM default sets the RAID controllers to have
the same World Wide Names.
- EnableDriveMigration.scr: The Enable drive migration script scans
the drives for configurations when they are added to a storage system
and will also attempt to use configurations found on the newly added
drives. The NVSRAM default will enable drive migration.
- DisableDriveMigration.scr: The disable drive migration script
allows the addition of disk drives while the system is running. in
addition, it identifies the drives as unused capacity regardless of
past drive configuration. The NVSRAM default will enable drive
migration.
4. When you are configuring IBM machine type 1742 or 3552 storage
controllers in host cluster Remote Mirror configurations, contact
IBM support for supported host cluster configurations and instructions
for configuring IBM storage controllers in clustered Remote Mirror
configurations.
=======================================================================
4.2 Unsupported configurations
------------------------------
The following lists configurations that are currently not being
supported with IBM FAStT Storage Manager 8.4.
1. Fibre Channel loop environments with the IBM Fibre Channel Hub,
machine type 3523 and 3534, in conjunction with the IBM Fibre Channel
Switch, machine types 2109-S16, 2109-F16 or 2109-S8. In this
configuration, the hub is connected between the switch and the IBM
Fibre Channel RAID Controllers.
2. The IBM Fibre Channel Hub, machine type 3523, connected to IBM
machine type 1722, 1742, 3542 and 3552.
=======================================================================
5.0 Unattended Mode
---------------------
N/A
=======================================================================
6.0 WEB Sites and Support Phone Number
----------------------------------------
6.1 IBM TotalStorage™ Disk Storage Systems Technical Support web site:
http://www.ibm.com/storage/support/fastt
6.2 IBM TotalStorage™ Marketing Web Site:
http://www.storage.ibm.com/hardsoft/disk/fastt/index.html
6.3 If you have any questions about this update, or problem
applying the update go to the following HelpCenter World
Telephone Numbers URL:
http://www.ibm.com/planetwide
=======================================================================
7.0 Trademarks and Notices
----------------------------
7.1 The following terms are trademarks of the IBM Corporation
in the United States or other countries or both:
IBM
FAStT
ToTalStorage™
the e-business logo
xSeries
pSeries
HelpCenter
Microsoft, Windows, and Windows NT are trademarks of Microsoft
Corporation in the United States, other countries, or both.
Java and all Java-based trademarks and logos are trademarks or
registered trademarks of Sun Microsystems, Inc. in the United
states, other countries, or both.
UNIX is a registered trademark of The Open Group in the United
States and other countries.
Linux is a registered trademark of Linus Torvalds.
Other company, product, and service names may be
trademarks or service marks of others.
=======================================================================
8.0 Disclaimer
----------------
8.1 THIS DOCUMENT IS PROVIDED "AS IS" WITHOUT WARRANTY OF
ANY KIND. IBM DISCLAIMS ALL WARRANTIES, WHETHER EXPRESS
OR IMPLIED, INCLUDING WITHOUT LIMITATION, THE IMPLIED
WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND
MERCHANTABILITY WITH RESPECT TO THE INFORMATION IN THIS
DOCUMENT. BY FURNISHING THIS DOCUMENT, IBM GRANTS NO
LICENSES TO ANY PATENTS OR COPYRIGHTS.
8.2 Note to U.S. Government Users -- Documentation related to
restricted rights -- Use, duplication or disclosure is
subject to restrictions set forth in GSA ADP Schedule
Contract with IBM Corporation.
Download Driver Pack
After your driver has been downloaded, follow these simple steps to install it.
Expand the archive file (if the download file is in zip or rar format).
If the expanded file has an .exe extension, double click it and follow the installation instructions.
Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.
Find the device and model you want to update in the device list.
Double-click on it to open the Properties dialog box.
From the Properties dialog box, select the Driver tab.
Click the Update Driver button, then follow the instructions.
Very important: You must reboot your system to ensure that any driver updates have taken effect.
For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.