Centaur Serial Product
Manufactory Test Program
~~~~~~~~~~~~~~~~~~~~~~~~
Copyright (C) 1999 ADMtek Incorporated.
All rights reserved. Jun. 28, 2001
****************************************************************************
%% Caution %%
This program only apply to that the device is usage 64*16bits(93C46).
Test Item
1.EEPROM read/write test
2.EEPROM auto load test
3.100 full duplex test
4.10 half duplex test
5.magic packet test
1. Environmrnt
==============
1.Hardware
X86 PC(Notebook) X 1
10/100 Switch(crossover cable) X 1
Server Card(Centaur PCI adapter)X 1
Client Card X 1
can use one switch or crossover cable to connect server and client.
2.Software
MS-DOS environment
Server Card's packet driver
Client Card's packet driver
While test program is running, it will load packet drivers of both
server and client.
2. Procedure
============
1.Make a server Card;
We use Centaur PCI adapter to be the server card with device ID 1216 and
vendor ID 1113.
a.Server card resident in the PC(Notebook).
b.Power on PC(Notebook) to MS-DOS Mode.
c.Modify "ADDR.NOW" and "ADDR.MAX" in 'SrvEprom' directory.
d.Depend on the server card to run "SROMB46.EXE" or "SROMB66" in
'SrvEprom' directory.
2.Put Server card and Client card into the X86 PC(Notebook).
3.Power on PC(Notebook) to MS-DOS Mode.
4.Copy all manufactory files in 'MF' directory to a same directory.
5.Modify "CLIENT.CFG", "ADDR.NOW" and "ADDR.MAX" for client card.
The CLIENT.CFG records the EEPROM content that will be writen on EEROM of
client card. ADDR.NOW records the Ethernet address(MAC ID) that will be
writen on EEPROM of client card. ADDR.MAX records the maximum limit of
Ethernet address(MAC ID).
6.Run "TESTER46.EXE" program for test.
PS.1.The "SROMB46.EXE" only use 93C46 EEPROM adapter, the "SROMB66.EXE"
only use 93c66 EEPROM adapter.
2.Regarding for the "Client.CFG", please refer to following list:
Model Interface Device-ID Vendor-ID SubSystem SubVendor
-------------------------------------------------------------------
ADM9510 PCI 0985 1317 9510 1317
3.The TESTER46.EXE parameter:
ADMtek Factory EEPROM Program and Test Program Version 2.04
USAGE : TESTER46.EXE -[parameter]
PARAMTER :
? : Display help screen.
e : Enable EEPROM test.
p : Enable pingpong test.
no parameter : Enable all test functions.
3. TEST Criteria
================
According to test items, if EEPROM read/write fail, test progarm will
determine "EEPROM read/write test" fail; if test program can't read
update data from PCI configuration space, it will determine autoload test
fail; if some packets are lost in pingpong test of different media modes,
it will respectively determine "AutoNegotiation test" fail or
"10 half duplex test" fail; if client card can't react to the magic packet
from server, test progarm will determine "magic packet test" fail.
4. Program Return Value for Test Result
=======================================
1 : Read PCI fail
2 : Fail to open file
3 : just only one card exists
4 : No packet driver found
5 : test result fail
6 : Packet driver loading fail
7 : No server card found
8 : EEPROM read/write test failure
9 : EEPROM auto load test failure
10 : 100 full duplex test failure
11 : 10 half duplex test failure
12 : Magic packet test failure
5. Files List
=============
Files Version Description
----------------------------------------------------------------------------
ADDR.NOW N/A Burn-in MAC address.
ADDR.MAX N/A Maximum value of MAC address.
CLIENT.CFG N/A Could be modified value of EEPROM for Client.
PKTDRV.COM 1.10 Packet driver of Client card.
PKTSRV.COM 1.10 Packet driver of Server card.
TESTER46.EXE 2.03 It can let you burn the EEPROM on board.
(DOS version)
----------------------------------------------------------------------------
6. Release History
==================
Release Number/Date Changes
----------------------------------------------------------------------------
V.2.02
02/28/2001 New Release
----------------------------------------------------------------------------
V.2.03
03/14/2001 1.Update packet driver for server and client.
2.Fix server CFID.
----------------------------------------------------------------------------
V.2.04
06/28/2001 1.Update the srombXX program for server.
2.Re-difind the default volue of EEPROM.
----------------------------------------------------------------------------
7. Support
==========
For technical support, please refer to the Installation Guide or
contact your authorized ADMtek distributors. You may also visit our WEB
site:
http://www.admtek.com.tw
*** All trademarks or brand names mentioned are trademarks or registered
*** trademarks of their respective companies.
Download Driver Pack
After your driver has been downloaded, follow these simple steps to install it.
Expand the archive file (if the download file is in zip or rar format).
If the expanded file has an .exe extension, double click it and follow the installation instructions.
Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.
Find the device and model you want to update in the device list.
Double-click on it to open the Properties dialog box.
From the Properties dialog box, select the Driver tab.
Click the Update Driver button, then follow the instructions.
Very important: You must reboot your system to ensure that any driver updates have taken effect.
For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.