; Maxim Smart Battery System Device Definition ; For use with SMBK GUI ;--------------------------------------------------------------------------- ; [address] section defines the SMBus device address ; and the display name that appears in the tab. ; ; For a smart battery, the SMBus device address must be 0x16. ; [address] 0x16=Generic Smart Battery ;--------------------------------------------------------------------------- ; [system] section defines the large bitmapped image with key parameters ; bitmap = filename of image to display ; <element> = <x> , <y> , <width> , <height> ; [system] bitmap=battery.bmp ; ; Dimensions of the standard sbs parameters 0x08Temperature=288,424,129,24 0x09Voltage=536,88,57,24 0x0ACurrent=440,522,57,24 0x0DRelativeStateOfCharge=592,48,97,24 0x0FRemainingCapacity=592,16,97,24 RemainingCapacityLabel=448,16,137,24 RelativeStateOfChargeLabel=448,48,137,24 ; ; Dimensions of the thermometer mercury Thermometer=349,456,5,30 ; ; Dimensions of the fuel gauge FuelGage=616,80,33,506 ; ReadCountText=112,456,129,24 UsePECsCheckBox=104,490,97,17 BatchReadCheckBox=104,506,97,17 ReadStatusButton=104,528,75,25 ; ; Dimensions of the optional manufacturer data displays ;cellVoltage1=544,452,57,24 ;cellVoltage2=544,368,57,24 ;cellVoltage3=544,286,57,24 ;cellVoltage4=544,204,57,24 ;--------------------------------------------------------------------------- ; Manufacturer data block ; ; <MfrDataVariable> = <byte offset> , <format> ; ; <byte offset> is a decimal number from 0 to 31 ; ; <format> must be one of the following formats. ; Suffix _MsbLsb means offset+0 is high byte, offset+1 is low byte ; Suffix _LsbMsb means offset+0 is low byte, offset+1 is high byte ; uint8 8 bit integer 0..255 ; int8 8 bit integer -128..+127 ; hex8 8 bit hexadecimal value 0x00..0xFF ; uint16_MsbLsb 16 bit integer 0..65535 ; uint16_LsbMsb 16 bit integer 0..65535 ; int16_MsbLsb 16 bit integer -32768..+32767 ; int16_LsbMsb 16 bit integer -32768..+32767 ; hex16_MsbLsb 16 bit hexadecimal value 0x0000..0xFFFF ; hex16_LsbMsb 16 bit hexadecimal value 0x0000..0xFFFF ; ; <MfrDataVariable> must be one of the following variable names: ; cellVoltage1 ; cellVoltage2 ; cellVoltage3 ; cellVoltage4 ; firmwareVersion ; diagnostic1 ; diagnostic2 ; diagnostic3 ; diagnostic4 ; diagnostic5 ; diagnostic6 ; diagnostic7 ; [0x22mfgrdata] ;diagnostic1=0,hex8Download Driver Pack
After your driver has been downloaded, follow these simple steps to install it.
Expand the archive file (if the download file is in zip or rar format).
If the expanded file has an .exe extension, double click it and follow the installation instructions.
Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.
Find the device and model you want to update in the device list.
Double-click on it to open the Properties dialog box.
From the Properties dialog box, select the Driver tab.
Click the Update Driver button, then follow the instructions.
Very important: You must reboot your system to ensure that any driver updates have taken effect.
For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.