FC HBA SCSI Miniport Driver for Windows
Release Notes
January 11, 2007
This software license applies only to QLogic customers.
QLogic Corporation.
All rights reserved.
Table of Contents
1. Version
2. Changes
3. Bug Fixes
4. Known Issues
5. Additional Information
6. History
7. Trademarks
8. Notices
9. Contacting Support
1. Version
These release notes describe the changes, fixes, known issues, and
release details that apply to FC HBA SCSI miniport driver, version
9.1.4.10.
This driver package includes firmware versions 3.03.21 (2Gb HBAs) and
4.00.26 (4Gb HBAs), as well as API versions 1.28.0.37 (QLSDM) and
2.0.0.14 (QL2XHAI2).
2. Changes
The following changes and fixes have been made to the FC HBA SCSI
miniport driver between versions 9.1.3.11 and 9.1.4.10.
Hardware Support
* Adhered to Subsystem Id document v2.2m+
NOTE: Microsoft requires all HBAs be supported in both x86 and
x64).
- Added support for the following devices (supported platforms):
PCI\VEN_1077&DEV_2322&SUBSYS_01151077 (x86, ia64, x64)
PCI\VEN_1077&DEV_2322&SUBSYS_01161077 (x86, ia64, x64)
PCI\VEN_1077&DEV_2422&SUBSYS_1336103C (x86, ia64, x64)
PCI\VEN_1077&DEV_2432&SUBSYS_015B1077 (x86, ia64, x64)
PCI\VEN_1077&DEV_5432&SUBSYS_01551077 (x86, x64)
PCI\VEN_1077&DEV_5432&SUBSYS_01561077 (x86, x64)
PCI\VEN_1077&DEV_2422&SUBSYS_014A1077 (ia64)
PCI\VEN_1077&DEV_2432&SUBSYS_014B1077 (ia64)
- Removed support for the following devices:
PCI\VEN_1077&DEV_6312&SUBSYS_01301077 (x86, x64)
PCI\VEN_1077&DEV_2422&SUBSYS_01471077 (ia64)
PCI\VEN_1077&DEV_2432&SUBSYS_01451077 (ia64)
OS Support
* Added support for the following operating systems:
- Windows Vista, 32-bit Intel x86
- Windows Vista x64
Software/Driver
* Updated "Get/Set" target link speed to new API interface in QLSDM
and driver.
* Increased loop back test buffer size to 2048 bytes in QLSDM.
Industry Standards Compliance
N/A
3. Bug Fixes
The following fixes have been made to the FC HBA SCSI miniport driver
between versions 9.1.3.11 and 9.1.4.10.
* Closed ER49768. Fixed a problem where the Loopback test always
failed when the NVRAM frame size is set to 512 or 1024 (Windows).
* Closes ER69282. Fixed a problem with IBM windows 2003 Cluster -
Event ID 11. On a 2-node cluster running Windows 2003 SP1 with
IBM configuration and QLogic ScsiMiniport, occasionally some Event
ID 11 with QLogic Event Code and Event Data (mailbox command
timeout) errors appeared in the event log.
* Closed ER48374. Fixed a driver problem with SANsurfer 5.0.0 build 4.
When configured with driver version 9.1.3.10b2 on a Windows IA64 SP1
platform, the HBA model numbers did not show up on the Information
Tab.
* Closed ER48117. Fixed an error with Long Erase (0x019) issues with
DLT S4 and QLE2462. Error occurred (most likely a bus reset) when
running a long erase that takes longer than 110 minutes on the
Quantum DLT-S4 drive, which exceeds the built-in 24xx firmware
timeout limit.
4. Known Issues
None
5. Additional Information
None
6. History
9.1.3.11 QL 3.03.21 4.00.23 - 10/05/06
* This version replaces the invalid release 9.1.3.10.
* FW versions: 3.03.21 (23xx), 4.00.23 (24xx).
* API versions: 1.28.0.35 (QLSDM), 2.0.0.14 (QL2XHAI2).
9.1.3.10 QL 3.03.21 4.00.23 - 09/20/06
* FW versions: 3.03.21 (23xx), 4.00.23 (24xx).
* API versions: 1.28.0.35 (QLSDM), 2.0.0.14 (QL2XHAI2).
* Added OEM specific support for assigning a Virtual World Wide
Port Name via the registry key.
* Added multiple BIOS support in QLSDM.
* Initialize debug file name variable during DLL load (QL2XHAI2).
* Closed EMC OPT23605: x64 Server hangs during boot at the
'Applying Computer Settings.'
* Cleanup code related to get Object text for OS Device Name
(QL2XHAI2).
* Closed ER47338: Attached target devices not visible to OS
after server reboot (QLE220).
* Closed ER47436: Driver not Login into Target Devices (QLE220).
* Closed ER47530: Topology diagram is not displaying properly
when LIP issued on QLA2462 port.
9.1.2.14 QL 3.03.19 4.00.23 - 06/30/06
* FW versions: 3.03.19 (23xx), 4.00.23 (24xx).
Closed ER46891: Bus Resets Under Heavy I/O Load.
* API Versions: 1.28.0.33 (QLSDM), 2.0.0.12 (QL2XHAI2).
* Closed OPT 235681: port failure after disconnecting and
reconnecting ISL port used by Mirrorview.
* Closed ER47235: SanSurfer pro does not display the topology
view correctly when the HBA's are set to loop only until
the system is rebooted.
9.1.2.13 QL 3.03.19 4.00.22 - 06/16/06
* FW versions: 3.03.19 (23xx), 4.00.22 (24xx).
* API Versions: 1.28.0.33 (QLSDM), 2.0.0.12 (QL2XHAI2).
* Added vpd update support for 2432 4-port adapter in 1.28.0.33
(QLSDM).
* Recognized Asynchronous Event 8048h as a valid AEN.
* Modified timer task to handle the case when HBA is in a stopped
state.
* Applies to 24XX only: Added support for NVRAM Nodename option
bit.
* Applies to 24xx only: Added support for reading data from
SFP (Small Form Factor Pluggable) optical transceivers via QLSDM.
* Adhered to Subsystem Id document v2.2g
- Added support for the following devices (supported platforms):
PCI\VEN_1077&DEV_2422&SUBSYS_014D1077 (x86, ia64, x64)
PCI\VEN_1077&DEV_2432&SUBSYS_014C1077 (x86, ia64, x64)
PCI\VEN_1077&DEV_2432&SUBSYS_01521077 (x86, ia64, x64)
PCI\VEN_1077&DEV_2432&SUBSYS_01531077 (x86, ia64, x64)
PCI\VEN_1077&DEV_2432&SUBSYS_01541077 (x86, ia64, x64)
PCI\VEN_1077&DEV_5432&SUBSYS_014E1077 (x86, x64)
* Adhered to firmware dump procedure per 2400 Series Firmware
Interface Specification version C.
* Closed ER47100: When you add 2nd FC NIC you get a bang in Device
Manager.
* Closed ER47113: RX2600 fails to boot Windows after 1MB bin
flash - SANsurfer 2.0.30b84_windows.
* Closed ER46811: Could not load Windows 2000 driver.
* Closed ER46586: "Bind By Port ID + Present Targets that are
persistently bound only" is not working (in loop environment).
* Changed to perform the full firmware dump when FW error occurs.
* Closed ER46141: JBOD disks turn offline in sansurfer GUI & scli
when settings are Present targets that are persistantly bound +
Bind by Port id (in loop environment).
* Corrected firwmare region size in option rom layout, i.e. firmware
size in flash.
* Closed ER45035: GPN_ID has wrong payload length after
unplug/replug.
* When the QLSDM is used to retrieve the transceiver data, you may
get SDMGT_CANNOT_GET_SFP_DATA error on system platforms using
certain models of Supermicro Motherboard such as P3TDL3 and P3TDLE.
This is because the underlying 24xx firmware (v4.00.21) used by
the QLSDM to retrieve the transceiver data is reporting an error
code of 4005 for this operation. The firmware group is currently
investigating this issue.
* Verified support for Atmel flash chip AT26DF081A.
9.1.2.11 QL 3.03.19 4.00.18 - 03/16/06
* FW versions: 3.03.19 (23xx), 4.00.18 (24xx).
* Adhered to Subsystem Id document v2.2f
- Added support for the following devices (supported platforms):
PCI\VEN_1077&DEV_6312&SUBSYS_01191077 (x86, x64)
PCI\VEN_1077&DEV_6312&SUBSYS_011C1077 (x86, x64)
PCI\VEN_1077&DEV_6312&SUBSYS_01301077 (x86, x64)
PCI\VEN_1077&DEV_6322&SUBSYS_012F1077 (x86, x64)
* Closed OPT226506: Hba does not relogin to target after target sends
LOGO to HBA.
* Closed ER44735: The link status behave differently between QLE-2460
and QLA2342.
* Closed ER45228: Incorrect HwVersion string is reported by QLogic
IHV HBA_GetAdapterAttributes call.
* Closed ER45232: Use memory map mechanism in the driver.
9.1.2.10 QL 3.03.19 4.00.17 - 02/13/06
* FW versions: 3.03.19 (23xx), 4.00.17 (24xx).
* Adhered to Subsystem Id document v2.2e
- Added support for the following devices (supported platforms):
PCI\VEN_1077&DEV_5432&SUBSYS_013E1077 (x86, x64)
PCI\VEN_1077&DEV_5432&SUBSYS_013F1077 (x86, x64)
PCI\VEN_1077&DEV_2422&SUBSYS_014A1077 (x86, x64)
PCI\VEN_1077&DEV_2432&SUBSYS_014B1077 (x86, x64)
* Added support to use combined 23xxipx firmware.
* Added support for SST25VF080B flash part.
* Added option not to dump code section for 24XX firmware dump.
* Closed ER44270: Serial number for the 4 G hba should be obtained
from the VPD.
* Closed ER38787: W2K/qla2340/veritas tape backup long cable pull
failed error mesage ERROR_DEVICE_NOT_CONNECTED.
9.1.1.10 QL 3.03.18 4.00.12 - 10/12/05
* Closed PTR 90818: Qlogic 4 GB driver returns selection timeout
immediateley after cable pull in an OEM special dual loop
configuration.
* Closed PTR 90652: Qlogic Driver returns a selection timeout when
rebooting a controller in an OEM special dual loop configuration.
9.1.0.13 QL 3.03.18 4.00.12 - 10/11/05
* Adhered to Subsystem Id document v2.2d
- Added support for the following devices (supported platforms):
PCI\VEN_1077&DEV_2422&SUBSYS_12D7103C (x86, ia64, x64)
PCI\VEN_1077&DEV_2312&SUBSYS_01491077 (x86, ia64, x64)
9.1.0.12 QL 3.03.18 4.00.12 - 09/21/05
* FW versions: 3.03.18 (23xx), 4.00.12 (24xx).
9.1.0.11 QL 3.03.16 4.00.12 - 08/29/05
* FW versions: 3.03.16 (23xx), 4.00.12 (24xx).
* Embedded 24XX FW in the driver.
* Closed ER43175: New driver could not detect any device to install
as BOOT from SAN on one specific setup.
9.1.0.10 QL 3.03.16 - 08/10/05
* FW versions: 3.03.16 (23xx), (Use onboard 24xx FW).
* Added 24XX support.
* Closed ER42601: Need to change bit used to control LED mode.
9.0.2.12 QL 3.03.13 - 04/07/05
* FW versions: 3.03.16 (23xx).
7. Trademarks
QLogic, the QLogic logo, QLA, SANbox, SANsurfer, and SANblade are
registered trademarks of QLogic Corporation.
SANtrack and SAN Express are trademarks of QLogic Corporation.
All other brand and product names are trademarks or registered
trademarks of their respective owners.
8. Notices
Information furnished in this document is believed to be accurate and
reliable. However, QLogic Corporation assumes no responsibility for
its use, nor for any infringements of patents or other rights of
third parties which may result from its use. QLogic Corporation
reserves the right to change product specifications at any time
without notice. Applications described in this document for any of
these products are only for illustrative purposes. QLogic Corporation
makes no representation nor warranty that such applications are
suitable for the specified use without further testing or
modification. QLogic Corporation assumes no responsibility for any
errors that may appear in this document.
9. Contacting Support
Please feel free to contact your QLogic approved reseller or QLogic
Technical Support at any phase of integration for assistance. QLogic
Technical Support can be reached by the following methods:
Web: http://support.qlogic.com
North America Contact Information
Email: support@qlogic.com
Phone: (952) 932-4040
Support contact information for other regions of the world is
available at the QLogic website: http://support.qlogic.com
© Copyright 2007. All rights reserved worldwide. QLogic, the QLogic
logo, and the Powered by QLogic logo are registered trademarks of
QLogic Corporation. All other brand and product names are trademarks
or registered trademarks of their respective owners.
Download Driver Pack
After your driver has been downloaded, follow these simple steps to install it.
Expand the archive file (if the download file is in zip or rar format).
If the expanded file has an .exe extension, double click it and follow the installation instructions.
Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.
Find the device and model you want to update in the device list.
Double-click on it to open the Properties dialog box.
From the Properties dialog box, select the Driver tab.
Click the Update Driver button, then follow the instructions.
Very important: You must reboot your system to ensure that any driver updates have taken effect.
For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.