¦b Linux 2.2.x ©M 2.4.x ®Ö¤ß¦w¸Ë©M³]©w Intel(R) Advanced Networking Services(ANS)¡]¶È Intel 32 ¦ì¤¸°ò¦¬[ºc¡^ =================================================================== 2001 ¦~ 8 ¤ë 10 ¤é ¤º®e ==== - ·§z©MÀô¹Ò - ¦w¸Ë Advanced Networking Services - ¤â°Ê¦w¸Ë©M³]©w - «ü¥OÀÉ°õ¦æªº¦w¸Ë©M³]©w - ¦b«·s¶}¾÷¸Ë¸m¶¡Àx¦s³]©w - ²¾°£ Advanced Networking Services - קï Advanced Networking Services ³]©w - ¥i¥Îªº«ü¥O - ³]©w AFT ¤p²Õªº½d¨Ò - ºÃÃø±Æ¸Ñ¡]¤]¥]¬AÀÉ®×»¼°e©M conf.modules ½d¨Ò¡^ - ±ÂÅv®Ñ ·§z©MÀô¹Ò ========== ¥»ÀÉ®×»¡©ú Intel(R) Advanced Network Services (ANS) ®M¸Ë³nÅé¡ALinux ªº 1.4x ª©¡C¥»®M¸Ë³nÅé¤w¸g¦b UP ©M SMP Intel ³B²z¾¹¬°°ò¦ªº PC ¤W¡A´ú¸Õ¹L 2.4.0 ª©ªº Red Hat* Linux* ¤F¡C ¦w¸Ëµ{¦¡°²³]©Ò¦³¥²»Ýªº«Ø¥ß¤u¨ã¡B®Ö¤ß¨Ó·½¥H¤Î¼ÐÃD³£¦b¾A·íªº¦ì¸m¨Ã¸g¹L¥¿ ½T³]©w¡C¨Ã¥B¡A±z¨Ï¥Îªº¬O±q http://support.intel.com ¤U¸üªº³Ì·s Intel °ò¦ÅX°Êµ{¦¡¡C¬Y¨Çµo§Gª©¥»¤¤´£¨Ñªº°ò¦ÅX°Êµ{¦¡¤£¥]§t ANS »Ýnªº¤ÄÂI¡C ª`·N¡G°ò¦ÅX°Êµ{¦¡¬°¤@¨Ç´ú¸Õª©¥\¯à´£¨Ñ¤ä´©¡C¦ý¬O¡A³o¨Ç¥\¯à¥Ø«e¤£¨ü¨ì ANS¡A¥]¬A Compaq Hotplug ©M Intel(R) Itanium(TM) °ò¦¬[ºcªº¤ä´©¡C ³o¨Ç Advanced Networking Services ¶È¥i¥H¨Ï¥Î©ó Intel(R) PRO/100 ©M PRO/1000 ¦øªA¾¹©M®à¤W«¬¤¶±¥d¡A¨Ã¥B¨CÓ¤p²Õ¦Ü¤Ö»Ýn¤@Ó¦øªA¾¹¤¶±¥d¡C ª`·N¡GLinux ¤£¨ü¨ì Intel(R) PRO/100 Intelligent ServerAdapter ¤ä´©¡C ANS ¤£¨ü¨ì Intel(R) PRO/100 VE Adapter ¤ä´©¡C ¥»®M¸Ë³nÅé¤ä´© IEEE VLAN ©M¥H¤Uªº¦¨²Õ¼Ò¦¡¡G * AFT ( 10/100 ©M 1000) Adapter Fault Tolerance * ALB ( 10/100 ©Î 1000) Adaptive Load Balancing (¥]¬A AFT) * FEC (10/100) ©Î GEC (1000) Link Aggregation/FEC/GEC ¦¨²Õ¼Ò¦¡ªº»¡©ú¥H¤Î¥¦Ìªº¯S©w»Ý¨D¬O¡G - AFT¡]Adapter Fault Tolerance¡^¡C¹w³]¼Ò¦¡¡C¥ô¦ó¥Dn³s½u¡]Æl½u¡B¤¶±¥d ©Î³s±µ°ð¡^¥¢±Ñ®É¡A¤p²Õ¤¤ªº¦¸n¤¶±¥d·|±µ¤â§@·~¡C¤@¦¸¶È¦³¤@Óºô¸ô¤¶± ¥d¦b§@¥Î¤¤¡C¿ù»~²¾Âà«á¡A¦pªG¥Dn¤¶±¥dªº³s½u´_ì¡A±±¨î·|¦Û°Ê¶Ç¦^¸Ó¥D n¤¶±¥d¡C±z¥i¥H²V¦X³t«×©MÂù¤u¥\¯à¤Î³]©w¡C¤]¥i¥H¨Ï¥Î¶°½u¾¹©Î¶}Ãö¡C - ALB¡]Adaptive Load Balancing ©Î«D¹ïºÙ³sµ²¶°¦X¡^¡C¥Dn¤¶±¥d¶i¦æ±µ¦¬©M ¶Ç¿é®É¡A·|¦³¤@²Õ 2-8 Ó¤¶±¥d¦@¥Î¶Ç¿é¸ü¤J¡C¨ä¤¤¥]¬A®e¿ù¡C¥Ø«e¡A³o¶µ¥\ ¯à¤£¤ä´©¤p²Õ¦¨û¤§¶¡²V¦X³t«×¢AÂù¤u³]©w¡C - FEC¡]Cisco* ªº Fast EtherChannel* Technology (FEC) ©Î Intel Link Aggregation¡^¡C¤@²Õ 2-8 Ó 10/100 ¤¶±¥d¦P®É±µ¦¬©M¶Ç¿é¸ê®Æ¡C¨ä¤¤¥]¬A®e ¿ù©M¸ü¤J¥¿Å¡C©Ò¦³¤p²Õ¦¨ûªº³t«×¢AÂù¤u³]©w¥²¶·¬Û²Å¡C¹F¨ì³o¨Çn¨D¥²¶·n ¦³¤@Ӥ䴩 Intel Link Aggregation ©Î Cisco FEC ªº¶}Ãö¡CSpanning Tree Protocol ¤@©wnÃö³¬¡C¥²¶·²Å¦X¶}Ãö¶°¦Xªº»Ý¨D¡C - GEC¡]Gigabit µ¥©ó FEC¡^»Ýn»P GEC ¬Û®eªº¶}Ãö©M PRO/1000 Adapter¡C»P¤Wz ªº FEC/LA »Ý¨DÃþ¦ü¡C ª`·N¡G¦pªG¬O AFT ©M ALB¡A±z¥i¥H«ü©wn±N¤p²Õ¤¤ªºþÓ¤¶±¥d·í¦¨¡§¥Dn¡¨©M ¡§¦¸n¡¨¤¶±¥d¡C¡§¥Dn¡¨¤¶±¥d¬O¤p²Õ¤¤¨Ï¥Îªº¥Dn¤¶±¥d¡C¦pªG¬O AFT¡A ¡§¥Dn¡¨¤¶±¥d¬O°ß¤@³Q¨Ï¥Îªº¤¶±¥d¡Aª½¨ìµo¥Í¿ù»~¬°¤î¡C¦pªG¬O ALB¡A ¡§¥Dn¡¨¤¶±¥d¬O¦P®É¶i¦æ¶Ç¿é©M±µ¦¬ªº¤¶±¥d¡C¡§¦¸n¡¨¤¶±¥d¬O¡§¥Dn¡¨ ¤¶±¥d¥¢±Ñ®É¡AÄ~©Ó¨ä¦ì¸mªº¦X¾A¤¶±¥d¡]¦pªG¤p²Õ¬O¥Ñ¨âÓ¥H¤Wªº¤¶±¥d©Ò ²Õ¦¨ªº¡^¡C¦pªG¨S¦³«ü©w¡§Àu¥ý¶¶§Ç¡¨¡A±N¨Ï¥Î³sµ²¤Wªº²Ä¤@Ó¥i¥Î¤¶±¥d¡C IEEE 802 Virtual LAN¡]VLAN¡^ ¬O¥H«Ê¥]¼ÐÃDªº·s¼W¼ÐÅÒ¬°°ò¦ªº¡Cºô¸ô¤W©Ò¦³³q¹L¦¹¬y ¶qªº³]³Æ¤@©wn¯à°÷³B²zÃB¥~ªºªø«×¡C¤¶±¥d¤Wªº³]©w¤@©wn»P¶}Ãö¤Wªº VLAN ³]©w¬Û²Å¡C VLAN ¤]·|·s¼W¨ì¸ü¤J®É¶¡¨Ãn¨DÃB¥~ªº°O¾ÐÅé¸ê·½¡C¨CÓ¤p²Õªº¦³ 64 Ó VLAN ªº¨î¡F ¦ý¬O¡AVLAN ¥i¥H§Q¥Î 1 ¨ì 4096 ¤§¶¡ªº¸¹½X½s¸¹¡C ¦w¸Ë ADVANCED NETWORKING SERVICES ®M¸Ë³nÅé ========================================== n¦w¸Ë©M½sĶ°ò¦ÅX°Êµ{¦¡®M¸Ë³nÅé¡A½Ð°Ñ¾\ÀHªþ¦b¨º¨Ç®M¸Ë³nÅ餤ªºÅª§ÚÀɮסC½Ð¨Ï¥Î Intel ¤ä´©ºô¯¸´£¨Ñªº³Ì·sÅX°Êµ{¦¡¡C *¤£¥i¥H¨Ï¥Î©ó eepro100¡]¥i¯à»Ýn²¾°£¼Ò²Õ¡^¡C ½Ð½T»{©Ò¦³ªº¤¶±³£¥i¥H§@·~¡A¨Ã¥B¦b¥H¤Uªº¦ì¸m¦³°ò¦ÅX°Êµ{¦¡ÀÉ®× e100.o ©M e1000.o¡G Y¬O 2.2.x ®Ö¤ß¡G/lib/modules/<kernelversion>/net/ Y¬O 2.4.x ®Ö¤ß¡G/lib/modules/<kernelversion>/kernel/drivers/net/ 1. ¥H root µn¤J¡C 2. ±N iANS-x.x.x.tar.gz ®M¸Ë³nÅéÀɮ׽ƻs¨ì±z¿ï¾Üªº¥Ø¿ý¤¤¡C 3. §Q¥Î°õ¦æ¡§tar xzf iANS-x.x.x.tar.gz¡¨¨Ó¶}±Ò®M¸Ë³nÅéÀɮסC ³o¼Ë·|¦b¥Ø«eªº¥Ø¿ý¤U«Ø¥ß iANS-x.x.x ªº¤l¥Ø¿ý¡C 4. ¿é¤J iANS-x.x.x ¥Ø¿ý¡C¿ï¾Ü¨ä¤¤¤@Ó¦w¸Ë¤èªk¡G 1. ¤â°Ê¡]«Øij¦³¸gÅ窺¨Ï¥ÎªÌ¨Ï¥Î¡^ 2. «ü¥OÀÉ°õ¦æ¡]¶È«Øij Red Hat* 6.x¡B7.0¡B7.1¡B SuSE* 6.4¡BCaldera* 2.2¡B©M TurboLinux* Server 6.0 ªº¨Ï¥ÎªÌ¨Ï¥Î¡^ ¤â°Ê¦w¸Ë©M³]©w -------------- 1. ±q¥Ø¿ý iANS-x.x.x °õ¦æ¡§make¡¨¨Ó½sĶ¼Ò²Õ¡C ª`·N¡GSMP/UP ©M MODVERSIONS ³£¬O¥Ñ¡§make¡¨¨M©wªº¡C¦pªG®Ö¤ß¨Ó·½ ¾ðª¬¥Ø¿ý©M°õ¦æ®Ö¤ß¤§¶¡ªº³]©w¤£¬Û²Åªº¸Ü¡A´N·|¥X²{ĵ§i°T®§¡C ½Ð°õ¦æ¡§make options¡¨¨Ó¦C¥X¸m´«¨Ó·½¾ðª¬¥Ø¿ý³]©wªº¥i¥Î¿ï ¶µ¡C¿ï¶µ¥]¬A SMP¡BMODVERSIONS¡B©M NODEBUG¡]¤£¦b²M³æ¤¤¡^¡C NODEBUG ȬO 0¡]¶}±Ò°£¿ù¡^©M 1¡]Ãö³¬°£¿ù¡^¡C¹w³]¬O 0¡C 2. °õ¦æ¡§make install¡¨¡C ª`·N¡G¹w³]Àɮצì¸m¥Ñ¡§make¡¨¨M©w¡C¦pªG®Ö¤ß¨Ó·½¾ðª¬¥Ø¿ý©M°õ¦æ®Ö¤ß ¤§¶¡ªº³]©w¤£¬Û²Åªº¸Ü¡A´N·|¥X²{ĵ§i°T®§¡C±z¥i¥H«·s¶}¾÷¨ì ²Å¦X®Ö¤ß¨Ó·½¾ðª¬¥Ø¿ýªº®Ö¤ß¡A©Î³]©w²Å¸¹³sµ² usr/src/linux¡A ¨Ï¨ä«ü¦V²Å¦X°õ¦æ®Ö¤ßªº®Ö¤ß¨Ó·½¾ðª¬¥Ø¿ý¡C Y¶·ÀɮײM³æ©M¥¦Ìªº¹w³]¦ì¸m¡A½Ð°Ñ¾\¥»«ü«n¤¤ªº¡§ºÃÃø±Æ¸Ñ¡¨³æ¤¸¡C 3. ¦pªG¬O ANS ¤ä´©¡A±z¥²¶·¨Ï¥Î PRO/100 ªº Base Driver 1.5.5¡]©Î§ó ·sªºª©¥»¡^©Î PRO/1000 ªº Base Driver 2.6.6¡]©Î§ó·sªºª©¥»¡^¡C ª`·N¡G½Ð½T©w¨S¦³¨ä¥¦°ò¦ÅX°Êµ{¦¡¸ü¤J©Î½sĶ¨ì¥ô¦ó Intel ¤¶±¥dªº ®Ö¤ß¡]¨Ò¦p¡Aeepro¡Beepro100¡Beexpress¡Be100¡Be1000¡^¡C½Ð ½T©w³]©wÀɪº½s¿è¥i¬°·sÅX°Êµ{¦¡´£¨Ñ§O¦W¡A¦Ó¤£¬O¥ô¦ó¥H«eªº ÅX°Êµ{¦¡¡C½Ð°Ñ¾\¡§ºÃÃø±Æ¸Ñ¡¨³æ¤¸¥HÀò¨ú½d¨ÒÀɮסC 4. »Ýnªº°ò¦ÅX°Êµ{¦¡¸ü¤J«á¡A½ÐÃö³¬¥ô¦ó¤w¸g·s¼W¨ì¤p²Õ¤¤ªº Intel ¤¶ ±¥d¡C¦pªG¥¦Ì¤w¸g¦³ IP ¦ì§}¡A½Ð°õ¦æ¡§ifconfig ethx 0.0.0.0¡¨¨Ó ²¾°£ IP ¸¹½X¡C ifconfig - a - ¦C¥X¥Ø«e©Ò¦³ªººô¸ô¸Ë¸m ifconfig ethx down - Ãö³¬¤¶±¥d¤~¯à¸ü¤J ANS ª`·N¡G±zÀ³¸ÓÅý¨ä¥¦¼t°Óªº Ethernet ¤¶±¥d¥H¤Î©Ò¦³¨S¦³·s¼W¨ì¤p²Õ¤¤ ªº Intel ¤¶±¥d«O¯d¦b³]©wª¬ºA¡C³o¼Ë¥i¥H½T«O«·s¶}¾÷«á¡Aºô¸ô ¸Ë¸m¦WºÙªº«ü©w¥i¥Hºû«ù¤@P¡C 5. °õ¦æ¡§insmod ians¡¨¨Ó¸ü¤J Advanced Networking Services¡C¦b¥H¤Uªº «ü¥O¦æ¤¤¡A¿ï¾Ü©Êªº¶µ¥Ø·|©ñ¤J [ ]¡C©Ò¦³ªº VLAN ³]©w³£·|¿ï¾Ü©ÊªºÅã¥Ü¡C 6. «Ø¥ß¤p²Õ¡G ianscfg -a -t<team_name> [-M<mode >] [-V] ¨Ï¥Î -M ºX¼Ð¨Ó«ü©w¦¨²Õ¼Ò¦¡¡]¹w³]¬° AFT¡A¨ä¥¦¬° NONE | ALB | FEC | GEC¡^¡C ¨Ï¥Î -V ºX¼Ð¨Ó«ü©w VLAN¡C ¦pªG±zn VLAN ¦b³æ¤@¤¶±¥d¤W¡A¤£n³sµ²¶°¦X¡A½Ð¨Ï¥Î -M NONE¡C ¨ä¥¦¼Ò¦¡¥i¥H³Q«ü©w¦P®É¨Ï¥Î VLAN ©M³sµ²¶°¦X¡C 7. ¨M©w¨CÓ¤p²Õªº¦¨²Õ¼Ò¦¡¡]AFT¡BALB¡BFEC¡BGEC¡^¡G ianscfg -C -t<team_name> -M<mode> ª`·N¡G±z¥i¥H¦b¨BÆJ 6 ©Î 7 «ü©w¤p²Õ¼Ò¦¡ 8. ±N Intel ¤¶±¥d·s¼W¨ì¤p²Õ¤¤¨Ã«ü©w¥¦Ìªº¨¤¦â¡]Àu¥ý¶¶§Ç¡^¡G ianscfg -a -t<team_name> -m<ethNN> [-p <priority role>] Àu¥ý¶¶§Ç¥i¥H¬OµL¡B¥Dn¡B©Î¦¸n 9. «Ø¥ßµêÀÀ¤¶±¥d¡G ianscfg -a -t<team_name> -v<vadapter_name> [-i<vlan_id>] °£¤F¡§ethx¡¨¥~¡Avadapter_name ¥i¥H¬O¥ô¦óªF¦è¡A¥un¨äµ²§À¬O¹ê¨Ò ¦r§À¡A¨Ã¥Bªø«×¨S¦³¶W¹L 15 Ó¦r¤¸´N¥i¥H¤F¡C¶È¦b¥H VLAN ¬°°ò¦ªº ¤p²Õ©Î¤¶±¥d«ü©w -i ¿ï¶µ¡]vlan_id¡^¡C 10. ±Ò°Ê¤p²Õ¡G ianscfg -c<team_name> 11. ±Ò°ÊµêÀÀ¤¶±¥d¡G ifconfig <vad_name> <ip#> netmask <mask#> [broadcast <broadcast>] ª`·N¡G³o¼Ë°µ·|±N³q°T¨ó©w³sµ²¨ì VIRTUAL ¤¶±¥d¡C 12. Àˬd¤p²Õª¬ºA¡G ianscfg -s ³oÓ®ÉÔ¡A¤p²Õ¤w¸g³Q±Ò°Ê¡A±zÀ³¸Ó¥i¥H³z¹LµêÀÀ¤¶±¥d¶Ç°e©M±µ¦¬«Ê¥]¡C «ü¥OÀÉ°õ¦æªº¦w¸Ë©M³]©w ---------------------- ¬°¤F¤è«K³]©w¡AIntel ¬°±z´£¨Ñ¶È¨ü¨ì¥H¤U¶µ¥Ø¤ä´©ªº¤¬°Ê¦¡«ü¥OÀÉ¡G Red Hat* (6.x, 7.0, 7.1) SuSE* (6.4) Caldera* (2.2) TurboLinux* (6.0 ¦øªA¾¹) ANS ³]©w¥|ӥؿý¡A¦WºÙ¤À§O¬° Red Hat¡BSuSE¡BCaldera¡B©M Turbo¡A¨Ó¹ïÀ³ ¡§iANS-x.x.x/install/¡¨¤Uªº³o¨Ç»¼°e¶µ¥Ø¡C n¨Ï¥Î¦w¸Ë«ü¥OÀÉ¡A½Ð¿é¤J¡§iANS-x.x.x/install/[dist_name]¡¨¡AµM«áÁä¤J ¡§./INSTALL¡¨¡C ª`·N¡GSMP/UP ©M MODVERSIONS ³£¬O¥Ñ¡§INSTALL¡¨¨M©wªº¡C¦pªG®Ö¤ß¨Ó·½ ¾ðª¬¥Ø¿ý©M°õ¦æ®Ö¤ß¤§¶¡ªº³]©w¤£¬Û²Åªº¸Ü¡A´N·|¥X²{ĵ§i°T®§¡C ½Ð°õ¦æ¡§INSTALL options¡¨¨Ó°Ñ¾\¤¹³\¸m´«®Ö¤ß¨Ó·½¾ðª¬¥Ø¿ý³]©wªº ÃB¥~½sĶ¶}Ãö¡C µM«á¡A¿í·Ó¥D±±¥x¤WÅã¥Üªº»¡©ú°õ¦æ¡C¦b¦¹¹Lµ{¤¤¡A±z¥²¶·¦^µª´XÓ°ÝÃD¡G 1. ¡§±zn³]©w¤½¥Îµ{¦¡¦Û°Ê²¾°£©Ò¦³ªººô¸ô¤¶±¶Ü¡H¡¨¦w¸Ëµ{§Ç¤@©wn±N »P Intel ¤¶±¥d¬ÛÃöªººô¸ô¤¶±¥dÃö³¬¤~¯à¸Ñ°£¸ü¤Jªº Intel ÅX°Ê µ{¦¡¡A¨Ã¥Î·sªºÅX°Êµ{¦¡¨ú¥N¡C ¿ï¨ú¡§Yes¡¨¡]¬O¡^¡]¹w³]È¡^¨Ó²¾°£©Ò¦³ªººô¸ô¤¶±¡A¥]¬A¨ä¥¦ªº«~µP¡C ¿ï¨ú¡§No¡¨¡]§_¡^¨Ó¿ï¾Ü¨CÓ¤¶±¡C 2. ¡§¿é¤J¤p²Õ¦WºÙ¡]«ö Enter Áä¡^¨Óµ²§ô¡C¡¨±z¥²¶·¿é¤J¤p²Õ¦WºÙ¡]¤£¥i¥H ¶W¹L 15 Ó¦r¤¸¡A³q±`¥H¹ê¨Ò¦WºÙµ²§ô¡^©Î«ö Enter¡]CR¡^Áä¨Óµ²§ô·s¼W ¤p²Õ¡C¦pªG±z¿ï¾Üµ²§ô¡A½Ð¸õ¨ì¨BÆJ 6¡C ¡§±zn¦b¤p²Õ¡]¦WºÙ¡^¤¤©ñ¸m VLAN ¶Ü¡H¡¨¿ï»P¡§Yes¡¨¨Ó«Ø¥ß¥H VLAN ¬°°ò¦ªº¤p²Õ¡C ¡§¿ï¨ú¤p²Õ¡]¦WºÙ¡^¦¨û¡¨·|¦C¥X©Ò¦³¾A¥Îªº¤¶±¡CÁä¤J¤¶±¥dªº¸¹½X ¨Ó±N¨ä·s¼W¨ì¤p²Õ¤¤¡C¿ï¨ú¨¤¦â¡]µL¡B¥Dn©Î¦¸n¡^¡C¬°¨CÓ¤¶±¥d «½Æ¦¹¨BÆJ¡C§¹¦¨®É¡A½Ð¿é¤J 0¡C 3. ¡§¿é¤J¤p²Õ¡]¦WºÙ¡^ªºµêÀÀ¤¶±¥d¦WºÙ¡C¡¨°£¤F¡§ethx¡¨¥~¡AµêÀÀ¤¶±¥d ¦WºÙ¥i¥H¬O¥ô¦óªF¦è¡A¥un¨äµ²§À¬O¹ê¨Ò¦r§À¡A¨Ã¥Bªø«×¤£¶W¹L 15 Ó ¦r¤¸¡C ¡§¿é¤JµêÀÀ¤¶±¥d¡]¦WºÙ¡^ªº VLAN id¡C¡¨VLAN id ¶È VLAN ¬°°ò¦ªº ¤p²Õ¨Ï¥Î¡C¿é¤J 1 ¨ì 4095 ¤§¶¡ªº¼Æ¦r¨Ó«ü©w¡§µêÀÀ LAN¡¨¡C ¡§¿é¤J¶}¾÷³q°T¨ó©w¡]none¡Bbootp¡Bdhcp¡B©Î other¡^¡C¡¨¿ï¾Ü¡§none¡¨¨Ó¤â °Ê¿é¤J IP ¦ì§}©Mºô¸ô¾B¸n¡C¿ï¾Ü¡§bootp¡¨©Î¡§DHCP¡¨¨Ó±q¥t¥~¤@³¡¹q¸£¿é¤J IP ¦ì§}©Mºô¸ô¾B¸n¡C©ÎªÌ¡A¿ï¾Ü¡§other¡¨¨Ó¿é¤J³q°T¨ó©w¦WºÙ¡]¨Ò¦p IP¡^¡C ª`·N¡G³o¨Ç¸ê°T·|¦b±z§¹¥þ³]©w¤p²Õ¨Ã½T»{¿ï¾Ü«á¤~·|Àx¦s¡C 4. ¡§¿ï¨ú¤p²Õ¡]¦WºÙ¡^ªº¦¨²Õ¼Ò¦¡ - None\AFT\ALB\FEC\GEC¡C¡¨Y¶· »¡©ú¡A½Ð°Ñ¾\¥»Åª§ÚÀɮתº Overview¡]·§z¡^©M Environment¡]Àô¹Ò¡^³¡¥÷¡C ¦pªG¬O Intel Link Aggregation¡A½Ð¨Ï¥Î FEC ©Î GEC¡C ĵ§i¡G¿ï¾Ü¡§none¡¨ÁÙ¬O·|«Ø¥ß¤p²Õ¡I 5. ¡§±z½T©w¶Ü¡H¡¨¿ï¾Ü¡§Yes¡¨¨Ó½T»{¿ï¾Ü¤p²Õ¡C¿ï¾Ü¡§No¡¨¨Óªð¦^¨BÆJ 3¡C ½T»{¤p²Õ«á¡A¥i¥H¦A°µ¥t¥~¤@Ó¤p²Õ©Î«ö¡§Enter¡¨¨ÓÄ~Äò¶i¦æ¡C 6. ¡§±znÀx¦s³oÓ³]©w¨Ã¦b¶}¾÷®É¸ü¤J¶Ü¡H¡¨¿ï¾Ü¡§Yes¡¨¡]¹w³]È¡^¨Ó±N ans ªì©l¤Æ«ü¥OÀɦX¨Ö¨ì¶}¾÷®É¶¡¶¶§Ç¤¤¡C¿ï¾ÜÀ³¸Ó¥ß¨è¸ü¤J ANS ¼Ò²Õªº°õ¦æ ¶¥¼h¡C«Ø¥ß¿ï¨ú©Mºô¸ô¶}¾÷¬Û¦Pªº¶¥¼h¡A³q±`¬O 2¡B3¡B4¡B©Î 5¡C¦pªG±z¤£n Àx¦s¶}¾÷ªº³]©w¡A½Ð¿ï¨ú¡§No¡¨¡C 7. ¡§±zn²{¦b±Ò°Êºô¸ô¶Ü¡H¡¨¿ï¨ú¡§Yes¡¨¨Ó±Ò°Ê¤p²Õ¡C¿ï¾Ü¡§No¡¨À³¸ÓÁÙ¬O ·|Åã¥Ü¦w¸Ë©M³]©w¦¨¥\§¹¦¨¡C¦pªG³]©w¦b¨BÆJ 6 Àx¦sªº¸Ü¡AANS ·|¦b«·s ¶}¾÷®É±Ò°Ê¡C ¦b«·s¶}¾÷¸Ë¸m¶¡Àx¦s ADVANCED NETWORKING SERVICES ³]©w ====================================================== ª`·N¡G¦pªG±z¨Ï¥Î«ü¥OÀÉ°õ¦æªº³]©w¤èªk¡A½Ð¤£n§¹¦¨³o¨Ç¨BÆJ¡C½d¨Ò¦æ ¬O±M¬° Red Hat 6.x ³]pªº¡C±z¥²¶·¬°±zªº»¼°eª©¥»×§ï½d¨Ò¡C ½Ðª`·N¡AEthernet ©M ANS ÅX°Êµ{¦¡¤w¸g³]©w¡A½Ð¿í·Ó¤U±ªº»¡©ú³]©w¨t²Î ¡AÅý¥¦¥H¬Û¦Pªº¶}¾÷¤è¦¡±Ò°Ê ANS¡C 1. °õ¦æ¥H¤U«ü¥O¨Ó±N ANS ³]©wÀx¦s¨ìÀɮפ¤¡G ianscfg -w [-f<file_name>] ¹w³]¬O '/etc/ians/ians.conf'¡C 2. ½Ð½T©w³Q¿ï¨ú¬°¤p²Õ¦¨û¤§¤@ªº¤¶±¥d¡§¨S¦³¡¨¦b±Ò°Ê®É³]©w¡C ¦pªGn³o¼Ë°µ¡A½Ð¦b¨CӲŦXªº¡§/etc/sysconfig/network-scripts/ ifcfg-ethX¡¨ÀÉ®×±N¡§ONBOOT=yes¡¨Åܧ󬰡§ONBOOT=no¡¨¡C 3. §Q¥Î«Ø¥ßÀɮס§/etc/sysconfig/network-scripts/ifcfg-<vadapter_name>¡¨ ¡A³]©wÅý¨CÓµêÀÀ¤¶±¥d¦b¶}¾÷®É³]©w¡CÀɮ׬ݰ_¨Ó¤@©wnÃþ¦ü³o¼Ë¡G DEVICE=<vadapter_name> BOOTPROTO="none" ONBOOT="yes" IPADDR="192.168.1.1" (½d¨Ò) NETMASK="255.255.255.0" (½d¨Ò) 4. «Ø¥ß¸ü¤J e100.o¡Be1000.o¡]¦pªG»Ýnªº¸Ü¡^©M ians.o ¼Ò²Õ¥H¤Î³]©w ANS ©Ý¾ëªºªì©l¤Æ«ü¥OÀÉ¡C±z¥i¥H±N¡§iANS-x.x.x/install/Red Hat/ans¡¨½Æ»s¨ì ¡§/etc/rc.d/init.d/ans¡¨¨Ó¨Ï¥Î½d¨Ò«ü¥OÀÉ¡C¨Ì·Ó¹w³]¡A³]©w·|±q¡§/etc/ians/ ians.conf¡¨³QŪ¨ú¡C¦pªG±z·Q¨Ï¥Î¨ä¥¦Àɮתº¸Ü¡A½Ðקï«ü¥OÀÉ¡C 5. ¬°¾A·íªº°õ¦æ¶¥¼h±N ANS «ü©wÀÉ·s¼W¨ìªì©l¤Æµ{§Ç¡C°õ¦æ¡§chkconfig --level <run levels> ans on¡¨¡A¦¹³Bªº <run levels> ¬O ANS ±Ò°Êªº°õ¦æ¶¥¼h¶°¡C ¨Ò¦p¡A345¡C ª`·N¡G¨t²Î±Ò°Êºô¸ôªA°È¡§¤§«e¡¨¡A¤@©wn¥ý©I¥s¥X³oÓ«ü¥OÀÉ¡CÁ|¨Ò¨Ó»¡¡A¦p ªG°õ¦æ¶¥¼h 3 ªººô¸ôªì©l¤Æ«ü¥OÀɬO¡§/etc/rc.d/rc3.d/S10network¡¨ ¡A½Ð«Ø¥ß¤@Ó«ü¦V¡§/etc/rc.d/init.d/ans¡¨ªº²Å¸¹³sµ² ¡§/etc/rc.d/rc3.d/S09ans¡¨¡Cºô¸ôªA°È°±¤î®É¡AANS ªA°È¤]·|¦Û°Ê°±¤î¡C ²¾°£ ADVANCED NETWORKING SERVICES ================================= ²¾°£ Advanced Networking Services ¦³¼ÆÓ¶¥¬q¡G * Ãö³¬©Ò¦³ªº vadapter ¤¶± * ±q¥¼¨Óªº«·s¶}¾÷¸Ë¸m²¾°£ ANS ³]©w * ²¾°£ ANS ¼Ò²Õ * ±q¨t²Î²¾°£ÀÉ®× ²¾°£ ANS ªº¤èªk¦³¨âºØ¡G¤â°Ê©M«ü¥OÀÉ°õ¦æ¡C ²¾°£ ANS ªº¤â°Ê¤èªk ------------------- 1. ¥H root µn¤J¡C 2. °õ¦æ¡§ifconfig -a¡¨¨Ó°Ñ¾\¨CÓ¨t²Î¤¤³]©wªºµêÀÀ¤¶±¥d¡C 3. ¬°¨CÓµêÀÀ¤¶±¥d°õ¦æ¡§ifconfig <vadapter_name> down¡¨¡C 4. §Q¥Î°õ¦æ¡§rmmod ians¡¨¨Ó²¾°£ ians ¼Ò²Õ¡C 5. ¦b¨CÓµêÀÀ¤¶±¥dÀɮפ¤¡AקïÀÉ®×¥H¥]§t¡§ONBOOT="no"¡¨¦æ¡A¦Ó¤£¥]§t ¡§ONBOOT="yes"¡¨¦æ©Î§¹¥þ²¾°£ÀɮסC 6. Y¬O¿W¥ß¦¡¤¶±¥dªº³]©wÀÉ¡A½Ð¦b /etc/sysconfig/network-scripts/ ¤U ¡AקïÀÉ®× ifcfg-ethX ¥H¥]§t¡§ONBOOT="yes"¡¨¦æ¡A¦Ó¤£¥]§t ¡§ONBOOT="no"¡¨¦æ¡C 7. ±z¥i¥H«O¯d Intel °ò¦ÅX°Êµ{¦¡¡A©ÎªÌ½s¿è¼Ò²Õ³]©wÀɮס]³q±`¬O ¡§/etc/conf.modules' or '/etc/modules.conf¡¨¡^¡A¨Ã¥B¥i¥H§Q¥Î²¾°£¥]§t e100 ©Î e1000¡]·s¼WªºÅX°Êµ{¦¡¡^ªº¦æ©M´_ì¨CÓ³Q¨ú®øªº¦æ¨Ó´_ìì©l®æ¦¡¡C 8. ²¾°£ ANS ªì©l¤Æ«ü¥OÀÉ¥H¤Î¥¦©Ò¦³ªº³sµ²¡]¨Ò¦p¡A¡§/etc/rc.d/init.d/ans¡¨©M ¡§/etc/rc.d/rc.3/S09ans¡¨¡^¡C 9. ±q iANS-x.x.x ¥Ø¿ý¡A°õ¦æ¡§make uninstall¡¨¨Ó²¾°£©Ò¦³ªºÀɮסC «ü¥OÀÉ°õ¦æªº¤èªk¡]¶È¨º¨Ç²[»\©ó«ü¥OÀɦw¸Ë¤¤ªº»¼°eª©¥»¡~ ------------------------------------------------------- 1. ¥H root µn¤J¡C 2. ¿é¤J iANS-x.x.x/install/[distribution_name] ¥Ø¿ý¡C 3. °õ¦æ¡§UNINSTALL¡¨¡C 4. ¨ä¥¦ªºµ{§Ç³£¬O¤¬°Ê©Êªº¡C½Ð¿í·Ó¥D±±¥x¤WÅã¥Üªº»¡©ú°õ¦æ¡C ´£¥Ü¡G ¡§´_즨û¤¶±¥d¦¨ì©l¨¤¦â¡]¿W¥ß¦¡¡^¡C¡¨ ¬°¨CÓ±znÄ~Äò¨Ï¥Î¿W¥ß¼Ò¦¡ªº¤¶±¥dµªÂС§Yes¡¨¡C³o¶µ³]©w¬O§Q¥Î Intel ªº e100(0).o ÅX°Êµ{¦¡§¹¦¨ªº¡F¦ý¬O¡A±zÁÙ¬O¥i¥H´_ì¨ä¥¦ªºÅX°Êµ{¦¡¡C ±q°O¾ÐÅé±N ANS ¼Ò²Õ²¾°£¨Ã¤£·|±N¥H¿W¥ß¼Ò¦¡°õ¦æªº¤¶±¥dÃö³¬¡C°£¤F¡§ /etc/ians/ians.conf¡¨¥~¡A³oÓ«ü¥OÀÉ·|±N©Ò¦³«Ø¥ßªºÀɮסB«ü¥OÀÉ©M³sµ²²¾°£¡C ¥Î¡§ì©l³]©w¡¨«·s±Ò°Êºô¸ô¡G Yn¨Ï·s³]©w¥Í®Ä¡A±z¥²¶·«·s±Ò°Ê¨t²Î©Î¥H«·s±Ò°Ê°Ñ¼Æ°õ¦æºô¸ôªì©l¤Æ«ü¥OÀÉ¨Ó «·s±Ò°Êºô¸ôªA°È¡G /etc/rc.d/init.d/network restart ª`·N¡G¦pªG±z¨Ï¥Î¦Û°Ê INSTALL ¤èªk¨Ó³]©w ANS¡A½Ðª`·N¨º¨Ç¦æ¬O³Q·s¼W¨ì ¡§/etc/conf.modules¡¨ÀɮסC³o¨Ç¦æ¤£¬O§Q¥Î UNINSTALL «ü¥OÀɲ¾°£ ªº¡C¦pªG±zn±N¥¦Ì²¾°£¡A¤@©wn¥H¤â°Ê¤è¦¡§¹¦¨¡C קï ADVANCED NETWORKING SERVICES ³]©w ====================================== ANS ³]©w©M©Ý¾ë¥i¥HÅܧó¡A¦ý¬O¦³¤@¨Ç¨î±ø¥ó¡C ½T»{«á¡A±z¥i¥HÅܧó¦¨ûÀu¥ý¶¶§Ç¡B·s¼W©Î²¾°£¤p²Õ¦¨û¡B·s¼W©Î²¾°£µêÀÀ ¤¶±¥d¡B©Î²¾°£¾ãÓ¤p²Õ¡C±z¤£¥i¥H¡G -Åܧó¤p²Õ¼Ò¦¡¡C -²¾°£¤p²Õ©ÎµêÀÀ¤¶±¥d¡C -²¾°£§@¥Î¤¤¤p²Õªº³Ì«á¤@Ó¦¨û¡C ¦pªG¤p²Õ¨S¦³¥ô¦ó¦øªA¾¹¤¶±¥d©Î¨S¦³¥ô¦ó¦¨û¡A¥¦·|¶i¤J¶¢¸mª¬ºAª½¨ì·s¼W ¦¨û¬°¤î¡C¦b³oºØ¶¢¸m´Á¶¡¡A¤p²Õ¨Ï¥Îªº¸ê·½¤£·|³QÄÀ©ñ¡C ¤p²Õ¡B¦¨û¤¶±¥d©MµêÀÀ¤¶±¥d¥i¥H¦bªA°È³z¹L§Ö³t·s¼W©M§Ö³t²¾°£¥\¯à°õ¦æ´Á¶¡¡A ¥H¦P¤@²Õªº«ü¥O¦b¶i¦æ´Á¶¡·s¼W¡C¤£n±N¦¹¥\¯à»P PCI Hot Plug Add/Remove¡]ÀH ´¡§Y¥Î·s¼W¢A²¾°£¡^²V²c¡C «·s³]©wªº¤èªk¦³¨âºØ¡G - ¥b¦Û°Ê¡G¾A¥Î©óÅܧó¼Ò¦¡©Î¦b¤p²Õ¶¡²¾°Ê¦¨û¡C·sªº¤p²Õ¤£¥i¥H¥Î³oÓ¥\¯à «Ø¥ß¡A¨Ã¥B©Ò¦³ªº¤¶±¥d³£¥²¶·ºû«ù¦b¤p²Õ¤¤¡C - ¤â°Ê«·s³]©w¡]½Ð°Ñ¾\¤U¤å¡^ ¥b¦Û°Ê«·s³]©w -------------- 1. ¤â°Êקï ANS ©Ý¾ë»¡©úÀÉ¡G /etc/ians/ians.conf 2. ¥Î«·s±Ò°Ê°Ñ¼Æ¨Ó©I¥s ANS ªì©l¤Æ«ü¥OÀÉ¡G /etc/rc.d/init.d/ans restart 3. n«·s±Ò°Ê¡A½Ð¥Î«·s±Ò°Ê°Ñ¼Æ¨Ó°õ¦æºô¸ôªA°Èªì©l¤Æ«ü¥OÀÉ¡G /etc/rc.d/init.d/network restart ¤â°Ê«·s³]©w ------------ 1. Ãö³¬µêÀÀ¤¶±¥d¡G ifconfig <vadapter_name> down 2. ²¾°£ ians ¼Ò²Õ¡G rmmod ians 3. «Ø¥ß©Îקï ians ©Ý¾ëÀɮרϨä»P³ß·Rªº©Ý¾ë¬Û²Å¡G ¹w³]¦ì¸m¡G/etc/ians/ians.conf ©Î«Ø¥ß¥]§t ianscfg¡]·|²£¥Í³ß·Rªº©Ý¾ë¡^¤§©I¥s¶°ªº«ü¥OÀÉ¡C 4. ¸ü¤J ians ¼Ò²Õ¡G insmod ians 5. °õ¦æ¦b¨BÆJ 3 «Ø¥ßªº«ü¥OÀÉ¡A©Î°õ¦æ«ü¥O¡G ianscfg -r [-f<filename>] ¦¹³Bªº <filename> ¬O·sªº©Ý¾ëÀɮסC 6. «³]¨CӫإߪºµêÀÀ¤¶±¥d¡G ifconfig <vadapter_name> <IPaddr> [netmask <NETMASK>] [broadcast <BROADCAST>] 7. Àx¦s·s³]©w¡G ianscfg -w [-f<filename>] ¬°¨CÓ·sªºµêÀÀ¤¶±¥d«Ø¥ß¤¶±³]©wÀÉ¡G * Àɮ׳q±`·|±`¾n©ó¡§/etc/sysconfig/network-scripts/¡¨ * ¦WºÙ®æ¦¡À³¸Ó¬O¡§ifcfg-<vadapter_name>¡¨ * ½d¨ÒÀɮפº®e¡G DEVICE=<vadapter_name> BOOTPROTO="none" ONBOOT="yes" IPADDR="192.168.1.1" NETMASK="255.255.255.0" 8. ¦pªG¦³³Ñ¤U¥ô¦ó¤£¥²nªºµêÀÀ¤¶±¥d³]©w¡A½Ð±N¨ä²¾°£©Îקï¡C 9. ¹ï©ó¨º¨Çn·í§@¿W¥ß³s½u¥Îªº¤¶±¥d¡A±z¥i¥HÄ~Äò¨Ï¥Î Intel °ò¦ÅX°Êµ{¦¡¡C ¥i¥Î«ü¥Oªº²M³æ¡G =============== «Ø¥ß¤p²Õ¡G «Ø¥ß¤p²Õ¡G ianscfg -a -t<team_name> [-M<mode>] [-V] ¨Ï¥Î -M ºX¼Ð¨Ó«ü©w¦¨²Õ¼Ò¦¡¡C¹w³]¬O¡§AFT¡¨¡C ¨ä¥¦¿ï¶µ¥]¬A¡§NONE¡¨¡B¡§ALB¡¨¡B¡§FEC¡¨©Î¡§GEC¡¨¡C ¨Ï¥Î -V ºX¼Ð¨Ó«ü©w VLAN¡C ³]©w¢AÅܧó¤p²Õ¼Ò¦¡¡]¶È½T»{«e¡^¡G ianscfg -C -t<team_name> -M <mode> ·s¼W¤p²Õ¦¨û¡G ianscfg -a -t<team_name> -m<ethNN> [-p Y] ¦¹³Bªº Y ¥i¥H¬O none¡]µL¡^¡Bprimary¡]¥Dn¡^©Î secondary ¡]¦¸n¡^©Î optional¡]¿ï¾Ü©Ê¡^¡C ¶È¦³²{¦sªº Intel Ethernet ¸Ë¸m¤~¥i¥H·s¼W¨ì¤p²Õ¤¤¡C ·s¼WµêÀÀ¤¶±¥d¡G ianscfg -a -t<team_name> -v<vadapter_name> [-i<vlan_id>] ª`·N¡G¦b«D VLAN ¤p²Õ¤W¡A¡§¶È¡¨¬°¨CÓ¤p²Õ©w¸q¤@ÓµêÀÀ¤¶±¥d¡C ¦b VLAN ¤p²Õ¤W¡A¤@©wn«ü©w -i ¿ï¶µ¡]vlan_id¡^¡C°£¤F ¡§ethx¡¨¥~¡AµêÀÀ¤¶±¥dªº¦WºÙ¥i¥H¬O¥ô¦óªF¦è¡A¦ý¬O¤@©wn ¥]¬A¹ê¨Ò¸¹½X¦r§À¡C ±Ò°Ê¡]½T»{¡^¤p²Õ¡G ianscfg -c<team_name> ¤p²Õ±Ò°Ê«á¡AÁÙ¬O¥i¥H·s¼W©Î²¾°£¦¨û¡C ª`·N¡G¦b³oÓ®ÉÔ¡AµêÀÀ¤¶±¥d·|¥X²{¡]ifconfig -a¡^¦b¤¶±¥d ²M³æ¤¤¡A¦ý¬O·|³B¦bÃö³¬ª¬ºA¡C ±Ò°ÊµêÀÀ¤¶±¥d¡G ifconfig <vadap_name> <ip#> netmask <mask#> broadcast <broadcast> ¨ú±oª¬ºA¡G ianscfg -s ¨ú±o ianscfg ¤½¥Îµ{¦¡ªº»¡©ú¡G ianscfg n²¾°£¦¨û¡G ianscfg -d -m<ethX> ª`·N¡G¤£n¦b¦¹«ü©w¤p²Õ¡C n°±¥ÎµêÀÀ¤¶±¥d¡G ifconfig <vadapter_name> down n²¾°£µêÀÀ¤¶±¥d¡]³Ì«á¤@Ó¤¶±¥d°£¥~¡^¡G ianscfg -d -v <vadapter_name> n²¾°£¤p²Õ¡]¦Ó¤£²¾°£¦¨û¢Avadapter¡^¡G ianscfg -d -t <team_name> n²¾°£¤p²Õ¡]»¼°j¦¡¦a°õ¦æ©Ò¦³ªº¬ÛÃö¦¨û©M vadapter¡^¡G ianscfg -d -t <team_name> -r n²¾°£ ANS ¼Ò²Õ¡]¥ýÃö³¬©Ò¦³ªº vadapters first¡^¡G rmmod ians n±q±zªº¨t²Î²¾°£ ANS Àɮס]Ãö³¬ vadapter ©M«³]³]©w«á¡^¡A½Ð±q iANS-x.x.x ¥Ø¿ý¡G make uninstall n¦bÀɮפ¤Àx¦s¥Ø«eªº³]©w¡]¶È½T»{«á¡^¡G ianscfg -w [-f <filename>] ¹w³]¬O¥i½s¿è¤å¦rÀɮסA¦W¬°¡§/etc/ians/ians.conf¡¨¡C n±qÀɮצ۰ʵ{¦¡¤Æ©Ý¾ë³]©w¡G ianscfg -r [-f <filename>] ¹w³]Àɮ׬O¡§/etc/ians/ians.conf)¡¨¡C Ãö³¬±´´ú¡G ianscfg -P -t<team_name> -d ¥Î VLAN ³]©w AFT ¼Ò¦¡ªº½d¨ÒÀɮסG¡]¨âÓ PRO/100 ¤¶±¥d¡^ ======================================================= insmod e100 insmod ians ianscfg -a -t team1 -M AFT -V ianscfg -at team1 -m eth0 -p primary ianscfg -at team1 -m eth1 -p secondary ianscfg -at team1 -v vadapt1 -i 10 ianscfg -at team1 -v vadapt2 -i 15 ianscfg -c team1 ianscfg -s ifconfig vadapt1 143.185.254.10 netmask 255.255.255.0 ifconfig vadapt2 143.185.254.10 netmask 255.255.255.0 ºÃÃø±Æ¸Ñ ======== 1. ¦pªG¤¶±¥d¤w¸g¥Î«ü¬£ªº IP ¦ì§}°õ¦æ¿W¥ß¦¡¼Ò¦¡¡A¤@©wn¦b±N¨ä·s ¼W¨ì¤p²Õ¤§«e¡A±N¨ä IP ¦ì§}³]©w¬° 0.0.0.0¡G ifconfig ethx {0.0.0.0}¡C 2. ±N³q°T¨ó©wµ²¦X¨ìµêÀÀ¤¶±¥d¡A¡§¤£n¡¨µ²¦X¨ì¤p²Õ¤¤ªº¤¶±¥d¤§ ¹êÅ餶±¥d¡C³oÂI¦P®É¤]®M¥Î©ó¿W¥ß¦¡¤¶±¥d¡C 3. ¦pªG±z¨S¦³±N³]©w¤¤¨ä¥¦¥i¯à°ò¦ÅX°Êµ{¦¡ªº°Ñ¦Ò²¾°£¡A±z§Æ±æ¦b ¤p²Õ¤¤¨Ï¥Î¤§¤¶±¥d·|±Á{¼ÆºØ¤¶±©M·N¥~µ²ªGªº·ÀI¡C 4. ¦pªG±z¦b¤p²Õ³]©w´Á¶¡±o¨ì¿ù»~°T®§¡A¡§module not loaded¡¨¡]¼Ò²Õ ¨S¦³¸ü¤J¡¨¡A½Ð±qÀY¶}©l¡C¦pªGn³o¼Ë°µªº¸Ü¡A½ÐÁä¤J¡G ./INSTALL veryclean all SMP=[0|1] MODVERSIONS=[0|1] ¬° SMP ¿ï¾Ü 0 ©Î 1¡A¨Ã¿ï¨ú MODVERSIONS ¨Ó²Å¦X¥Ø«e®Ö¤ß¾ðª¬¥Ø¿ý ªº³]©w¡C ª`·N¡G·í¥Ø¼Ð¼Ò²Õ»P®Ö¤ßª©¥»¤£²Å¡A¥H¤Î·í¦w¸Ë¦b¨S¦³°Ñ¼Æªº±¡ªp¤U §¹¦¨®É¡A´N·|µo¥Í³o¶µ¿ù»~¡]¨Ï¥Î¡§./INSTALL¡¨¿ï¶µ®Éµo²{ªº¡^¡C 5. ·s¼W ANS «ü¥OÀɨìªì©l¤Æµ{§Ç®É¡A¦pªG±z¦¬¨ì¿ù»~°T®§¡§service ans does not support chkconfig¡¨¡]ªA°È ans ¤£¤ä´© chkconfig¡^¡A ½Ð¿é¤J¤U¦æ¡A¥H¨ü°Ê¤è¦¡¬°¨Cӳ߷Rªº°õ¦æ¶¥¼h«Ø¥ß¨ì ans Àɮתº²Å¸¹ ³sµ²¡G ln -s /etc/rc.d/init.d/ans /etc/rc.d/rcX.d/S09ans ¦¹³Bªº X ¬O³ß·R°õ¦æ¶¥¼hªº¸¹½X¡C 6. ¦pªG±z¨Ï¥Î Jumbo Frames ±N¤¶±¥d²¾¶i©Î²¾¥X¤p²Õªº¸Ü¡A½ÐÀˬd Jumbo Frames ªº MTU ³]©w¡C ANS ª©¥»¾ðª¬¥Ø¿ýªºµ²ºc¡G * ®Ö¤ß¨Ì¦s¨Ó·½Àɮס]src/*.[ch], src/lib/*.[ch]¡^ * ®Ö¤ß¨Ì¦s¹w¥ý½sĶª«¥óÀɮס]bin/iANS_core.o¡^ * Makefiles * Advanced Networking Services ³]©w¤½¥Îµ{¦¡¡]bin/ianscfg¡^ * Advanced Networking Services ²£¥Í¤½¥Îµ{¦¡¨ó§Uµ{¦¡¡]bin/iansd¡^ * ¦w¸Ë¡B¸Ñ°£¦w¸Ë©M³]©w«ü¥OÀÉ ÀÉ®×»¼°e¡G ¨Ì·Ó¹w³]¡A»¼°eªº¤¸¥ó¦p¤U¡G -2.2.x ª©®Ö¤ß¡G /lib/modules/[KERNEL_VERSION]/net/ians.o -2.4.x ª©®Ö¤ß¡G /lib/modules/[KERNEL_VERSION]/kernel/drivers/net/ians.o - /usr/sbin/ianscfg - /usr/sbin/iansd - RedHat 6.x ª©¡G /usr/man/man1/ianscfg.1 - RedHat 7.x ª©¡G /usr/share/man/man1/ianscfg.1 conf.modules ÀÉ®×½d¨Ò¡G #alias eth0 eepro100 #alias eth1 eepro100 #alias eth2 eepro100 alias eth0 e100 alias eth1 e100 alias eth2 e100 alias parport_lowlevel parport_pc alias scsi_hostadapter aic7xxx ±ÂÅv®Ñ ======= Intel Corporation ª©Åv©Ò¦³ (c) 1999- 2001 ¦~¡C«O¯d¤@¤ÁÅv§Q¡C ¦pªG²Å¦X¥H¤U±ø¥ón¨D¡A¤¹³\¦A»¼°e©M¨Ï¥Îקï©Î¥¼×§ïªºµ{¦¡½X©M¤G¶i¦ì®æ¦¡¡G 1. ¦A»¼°eµ{¦¡½X¥²¶·ºû«ù¤WzªºµÛ§@Åv»¡©ú¡B¥»±ø¥ó²M³æ©M¥H¤Uªº§K³dÁn©ú¡C 2. ¥H¤G¶i¦ì®æ¦¡¦A»¼°e¤@©wn¥H¤å¥ó§Î¦¡½Æ»s¤WzªºµÛ§@Åv»¡©ú¡B¥»±ø¥ó²M³æ ©M¥H¤Uªº§K³dÁn©ú¡A¥H¤Î¨ä¥¦ÀHªþ»¼°eª©¥»´£¨Ñªº¸ê®Æ¡C 3. ¥¼¨Æ¥ý¨ú±o®Ñ±³\¥i¡Aµ´¹ï¤£¥i¥H¥Î Intel Corporation ªº¦WºÙ©Î¨ä°t¾P °Óªº¦WºÙ¨Ó±ÀÂ˩δ£Ò¦¹³nÅél¥Í¥Xªº²£«~¡C ¥»³nÅé¥Ñ¨äµÛ§@Åv«ù¦³ªÌ©M°^ÄmªÌ¨Ì¡§ì¼Ë¡¨´£¨Ñ¡A¦b¦¹§_»{¥ô¦ó©ú¥Ü©Î ·t¥Üªº«O©T¡A¥]¬A¡]¦ý¤£¶È©ó¡^¾A¾P©Ê©M¾A¥Î©ó¯S©w¥Øªºªº·t¥Ü«OÃÒ¡C ¦b¥ô¦ó±¡ªp¤U¡A°^ÄmªÌ³£¤£¶·¦]¥ô¦óª½±µ¡B¶¡±µ¡B·N¥~¡B¯S®í¡Bĵ§Ù©Ê¡B ©ÎÄòµo©Êªº·l¥¢¡]¥]¬A¡A¦ý¤£¶È©ó¡A±ÄÁÊ´À¥Nª««~©ÎªA°È¡BµLªk¨Ï¥Î¡B ¸ê®Æ¿ò¥¢¡B©Î§Q¼í·l¥¢¡B©ÎÀç·~¤¤Â_¡^t³d¡A¤£½×³o¨Ç·l¥¢¬O§_¦]¨Ï¥Î¦¹ ³nÅé¤Þ°_¡A·l¥¢ªº»F¦]©M³d¥ô²z½×¬O¤°»ò¡B¬O§_¥ß¨ã©ó¦X¬ù¤¤¡A¬O§_¬°«á ªG³d¥ô¡B©Î¹Hªk¦æ¬°¡]¥]¬A¹L¥¢¡Aµ¥µ¥¡^¡A§Y¨Ï°^ÄmªÌ¬O§_¨Æ¥ýª¾¹D¦¹Ãþ ·´·lªº¥i¯à©Ê¥ç¤£¶·¬°¦¹t³d¡C * ¨ó¤O¼t°Óªº°Ó¼Ð¬O¨äÓ§O©Ò¦³ªº°]²£¡CDownload Driver Pack
After your driver has been downloaded, follow these simple steps to install it.
Expand the archive file (if the download file is in zip or rar format).
If the expanded file has an .exe extension, double click it and follow the installation instructions.
Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.
Find the device and model you want to update in the device list.
Double-click on it to open the Properties dialog box.
From the Properties dialog box, select the Driver tab.
Click the Update Driver button, then follow the instructions.
Very important: You must reboot your system to ensure that any driver updates have taken effect.
For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.