readme.txt Driver File Contents (40002089_L.zip)

                          Release Notes
                           PN 93000379

             Digi AccelePort Xp, RAS and Sync Drivers
                         Version 4.0.228.0

                      Microsoft Windows 2000
              Microsoft Windows XP Home/Professional

                         Software Package
                          PN 40002089_L

                           04/30/2002


INTRODUCTION

   This driver supports all Digi adapters listed below. These adapters
   provide connectivity in a Windows 2000 environment and support a
   broad range of WAN connections, including serial, V.90 modems,
   ISDN (BRI and PRI), Frame Relay, SNA (SDLC, X.25/QLLC), PPP
   and X.25 protocols.

   Digi International announced the discontinuation of the DataFire RAS
   product line in September 2001.

   In our continued effort to support DataFire RAS customers, we entered
   into a definitive agreement to sell the DataFire RAS product line to
   Patton Electronics Company in November 2001. All business areas related
   to the DataFire RAS product line are now handled by Patton Electronics.

   If you have any technical questions with respect to the DataFire RAS
   product line, please contact Patton Electronics via e-mail at
   support@patton.com, or call 1-301-975-1000 and ask for the technical
   support team.

   Additional information is also available on the Patton Electronics
   website at <http://datafire.patton.com>, including driver updates and
   future releases.

   Please note that the AccelePort RAS product line is NOT part of the
   DataFire RAS product line acquisition by Patton Electronics.
   Digi International will continue to sell and fully support all
   AccelePort RAS products without restrictions.


SUPPORTED PRODUCTS

   AccelePort Xp Family of Adapters:

      AccelePort 2p
      AccelePort 4p
      AccelePort 8p
      AccelePort 16p

   DataFire RAS PTE Family of Adapters:

      DataFire RAS 24 PT1
      DataFire RAS 48 PT2
      DataFire RAS 30 PE1
      DataFire RAS 60 PE2

   DataFire RAS B4STU Family of Adapters:

      DataFire RAS B4U
      DataFire RAS B4ST

   DataFire DSP CompactPCI Family of Adapters:

      DataFire DSP 24 PT1 CompactPCI
      DataFire DSP 48 PT2 CompactPCI
      DataFire DSP 30 PE1 CompactPCI
      DataFire DSP 60 PE2 CompactPCI

   AccelePort RAS Family of Adapters:

      AccelePort RAS 4
      AccelePort RAS 8

   DataFire PRIme Family of Adapters:

      DataFire PRIme PCI T1
      DataFire PRIme PCI E1

   DataFire Sync Family of Adapters:

      DataFire Sync 2000 2P   PCI
      DataFire Sync 2000 2P+  PCI
      DataFire Sync 2000 4P   PCI
      DataFire Sync 2000 4P+  PCI

      DataFire Sync 2000 2P   CompactPCI
      DataFire Sync 2000 2P+  CompactPCI
      DataFire Sync 2000 4P   CompactPCI
      DataFire Sync 2000 4P+  CompactPCI

      DataFire Sync 2000 2P   PMC
      DataFire Sync 2000 2P+  PMC
      DataFire Sync 2000 4P   PMC
      DataFire Sync 2000 4P+  PMC

      DataFire Sync/570  2P   PCI
      DataFire Sync/570  4P   PCI


KNOWN LIMITATIONS

   Installation/User Interface:

      You must follow the procedure outlined in the "DRIVER INSTALLATION NOTES
      FOR WINDOWS 2000" section of this document to properly install the
      driver set.

      Within the wizard mode, if invalid input has been entered and back
      button is pressed, an error message may appear indicating that
      the input is invalid.  A valid input needs to be entered to be able
      to go back.

   PortAssist Viewer:

      PortAssist Viewer is the diagnostics application used to troubleshoot problems
      on your WAN connections. There is no Start menu link to run PortAssist Viewer.
      To run PortAssist Viewer, choose Start|Run and enter Digiview. If you
      reconfigure or install adapters while PortAssist Viewer is running, you are
      prompted to reboot for those changes to take effect.

   PortAssist Manager:

      PortAssist Manager is the web based monitoring tool for Acceleport Xp,
      Acceleport RAS, and DataFire RAS adapters. If you reconfigure or install
      adapters while PortAssist Manager is running, you are prompted to
      reboot for those changes to take effect.

   RAS Adapters:

      On Channelized T1 Wink Start Trunks without dial tone supervision,
      modems must be initialized with ATX3 for dial out.

      When configuring dial up modem service for a line, all modems on the
      line should be configured since incoming calls may be assigned to any
      channel.

      On ISDN Trunks, the following rules are applied to modem dial strings:
      1. A comma (delay) in the first or second position is allowed.
      2. Then the first non-numeric character terminates the dial string
         (e.g. 9,12345678 is a valid dial string and 9,1,234-5678 is not).

   SYNC Adapters:

      When using the SDLC interface, the maximum BTU (Basic Transmission
      Unit) is limited to 521 bytes. This is a known limitation of the
      IBM SDLC link service provided in SNA Server. See the Microsoft SNA
      article, "Maximum BTU Limit for Dumb SDLC Interface" for more
      information.

   Sync/570 Adapters:

      When installing additional Sync/570 adapters, a system reboot is
      required to complete the installation. The new adapters will not
      function until the system is rebooted.


DRIVER INSTALLATION NOTES FOR WINDOWS 2000

   Note: Update Driver functionality is not currently supported.  If you have
   already installed drivers for your adapter, you must uninstall them first.
   Otherwise, skip to step 2.

   1. Uninstall previously installed drivers.  From the "Device Manager"
   right-click on the Digi adapter(s) you would like to uninstall from the
   system and select "Uninstall".

   2. Run the program DgClean.cmd to remove existing INF files for your
   adapter.  This will ensure the new drivers will be installed correctly.
   Dgclean.cmd is located in the folder with your downloaded drivers.

   3. Shutdown your computer and install the adapter according to the
   "Hardware Installation Instructions" included with the adapter.

   4. Start your computer and login.  When the "Found New Hardware Wizard"
   appears, follow instructions to "Search for a suitable driver for my
   device".  Specify the folder in which you downloaded the driver.

   5. Windows will display a "Digital Signature Not Found" message, explaining
   that the drivers are not signed.  Click "Yes" to continue the installation.
   You will see several of these warnings,  click "Yes" to continue through all
   of them.

   6. Follow instructions to complete the installation.

   7. The "Found New Harware Wizard" may appear several times more depending
   on the number and type of adapters you are installing.


HISTORY

   Version 4.0.228.0 (L Release)

      BUG FIXES

        Fixed: DataFire Sync configuration dialog for X.25 does not show up (#8068)
        Fixed: DataFire Sync bugchecks under HIS 2000 SNA configuration (digisoh.sys) (#7820)
        Fixed: WanLinks driver doesn't remove keys from SERIALCOMM when uninstalled (#8412)
        Fixed: The DigiAsyn.sys driver is hanging in an endless loop (#7656)
        Fixed: AccelePort Xp bugchecks when returning from Standby (random) (#7649)
        Fixed: Parity error detection failure with AccelePort Xp (#7542)
        Fixed: Microsoft FAX does not work with AccelePort Xp (#5702)
        Fixed: Unable to print with AccelePort Xp (#5081)
        Fixed: Multiple issues with E1/R2 parameter configuration (#7956, #7897)
        Fixed: The DigiAsyn.sys driver doesn't handle zero length read requests correctly
        Fixed: Some timed-out writes are being inadvertently completed with STATUS_CANCELLED
        Fixed: Write timeout does not work when Write Complete When Sent option is enabled
        Fixed: Dgclean.cmd does not delete DIGIMPS.inf and MDMDGDEN.inf files
        Fixed: DataFire Sync driver may crash during driver update or uninstall

        Updated DataFire RAS firmware to M release. Detailed information about firmware
        enhancements and bugfixes can be found in the DataFire RAS firmware Release Notes.

   Version 4.0.217.0 (L3P)

      BUG FIXES

        Fixed: Caller DID option within Windows 2000 server is not working (#5576)
        Fixed: E1/R2 GroupB and backward signalling range incorrect (#5653)
        Fixed: DgUpdate.exe fails with error unable to find specified file (#7203)
        Fixed: Add Channel Mapping option for DataFire RAS24/48/30/60 CT1 and PRI (#7380)
        Fixed: Driver does not start when installing L2P from scratch (#7582)
        Fixed: DeviceIoctls test application causes bugcheck with AccelePort Xp (#7656)

   Version 4.0.214.0 (L2P)

      BUG FIXES

        Fixed problem establishing a fax connection (#7220,#5702)
        Fixed dgupdate issues (#7203)
        Fixed multiple Sync2000 issues in preparation for WHQL submission
          (#6308,#6307,#6306,#6113,#5802,#5783,#5782)
        Corrected inf issues in preparation for WHQL submission (#6907)
        Fixed serial printing errors (#5221,#5081)
        Fixed 15 second delay on ring back for dense modems (#5099)
        Changed Sync2000 PLX9080 setup to initialize in PCI 2.1 mode.
	    Problem with modem country setting for E1/T1 cards (#5764)
	    DM_BB diagnostic not working on Win2K (#4577)
	    RasAudio diagnostic not working on Win2K (#5303)
	    Port Assist Viewer doesn't display RAS30/60 boards in E1R2 mode (#5071)
	    Port Assist Viewer doesn't show ISDN layer 3 status (#3976)
	    Port Assist Viewer faults when clearing statistics (#2495)
	    Debug information displayed in free build (#5617)

   Version 4.0.210.0 (L1P)

      This version was not released to the public.
Download Driver Pack

How To Update Drivers Manually

After your driver has been downloaded, follow these simple steps to install it.

  • Expand the archive file (if the download file is in zip or rar format).

  • If the expanded file has an .exe extension, double click it and follow the installation instructions.

  • Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.

  • Find the device and model you want to update in the device list.

  • Double-click on it to open the Properties dialog box.

  • From the Properties dialog box, select the Driver tab.

  • Click the Update Driver button, then follow the instructions.

Very important: You must reboot your system to ensure that any driver updates have taken effect.

For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.