Updates2.txt Driver File Contents (Geo_20PMAC_20Two_20Channel_20Executive_20Pro2.zip)

			Pro Suite 2 Components:

PMAC Executive	Pewin32Pro2	 (32 bit)	Version 4.X.X.X
PMAC Tuning	PmacTuningPro2	 (32 bit)	Version 4.X.X.X
PMAC Plot 	PmacPlotPro2	 (32 bit)	Version 4.X.X.X
PMAC1 Setup 	P1Setup32Pro2	 (32 bit)	Version 4.X.X.X
PMAC2 Setup 	P2Setup32Pro2	 (32 bit)	Version 4.X.X.X
Turbo Setup 	TurboSetup32Pro2 (32 bit)	Version 4.X.X.X
UMAC Configurator UMACConfigPro2 (32 bit)	Version 4.X.X.X
GEO Brick Setup GeoBrickSetup	 (32 bit)	Version 1.X.X.X


/////////////////////////////////////////////////////////////////
****************** PcommServer ENHANCEMENTS *********************
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\

. Initial delay at the startup is eliminated now since PcommServer does 
  not try to communicate to all configured devices at the startup.
  Further, a lot of effort was made to improve the performance of USB
  and Ethernet communication. 
. USB Unplug event works much better than the Pewin32PRO version.
. Ethernet connect is improved considerably. In case of device not 
  connected the initial timeout is reduced to less than 4 seconds.
. The Ethernet device configuration in the Pewin32Pro2 is made simple
  now. For a pre-configured Ethernet based PMAC, ETHConfigure / 
  EthUSBConfigure are no longer required. These applications are only
  needed if the IP address is unknown or communication CAN NOT be 
  established at the default IP address of (192.6.94.5). See the Delta 
  Tau's driver installation instructions "DT Driver_Install.pdf" for 
  details.

/////////////////////////////////////////////////////////////////
******************** Pewin32PRO2 FEATURES ***********************
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\

. Pewin32Pro2 is completely recompiled to communicate directly to 
  PComm32Server's COM Interface using VCL and latest software tools.
  Borland CBuilder 6.0 is used as the platform for development. PCommServer 
  and other Ring zero drivers are compiled using Microsoft .NET C++ 7.0.

  In addition to all of the Pewin32Pro's previous features, including Color 
  editor, with PLC debugger, versatile watch and position windows and smart
  terminal window. various variable configuration menus, particularly the 
  P,Q,M and I-variables, have been improved a lot for added features, as
  uploads, download and refresh etc.
. The Worksapce is fully functional along with project management capability.
  Workspaceis saved in an INI file. The default workspace file 
  Pewin32Pro2_Default.INI is stored in the application folder. Name and 
  location cane be changed at any time.
  This workspace file keeps tarck of all the open forms including their sizes, 
  device association, update rate, state at the close of pervious session, and 
  other related parameters as color, font and units and scales.
  Workspace can be edited outside the application for desired changes.
. Project manager is yet another added feature of Pewin32Pro2. It allows for
  multiple files to be associated with a project (essentially associated with
  any one PMAC). Please browse for detailed project features.
. Terminal is made smart to correctly keep track of previous commands. Status
  screens are modified to display the exact register and bit numbers for each
  item.
. Choice of PMACSelect in each form is a feature that is very useful for expert 
  users. It increases the versatility of the program. This allows for selection 
  of any available device for any form with the need for a Terminal to be open. 
  Further, the update period is selectable for most of the forms.

/////////////////////////////////////////////////////////////////
************************ NEW FEATURES ADDED *********************
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
Minor changes from Pewin32Pro to Pewin32Pro2
. All interrupts received from the PMAC are handled by event handle in the TPmac 
  class and are listed in the Interrupt monitor tab in the main MessageFrame. 
  Interrupts are still initiated in the Terminal screen. Once initialized, all 
  received interrupts are displayed in the Interrupt monitor tab of the main 
  MessageFrame.
. Unsolicited response are also displayed in the Unsolicited response Tab of the 
  main MessageFrame. The option to display the Unsolicited response and 
  frequency to check them is configured in the General Setup and Options' "View"
  tab.
. Now Pewin32Pro2 can poll every PMAC opened in Terminal and saves the basic 
  info in a Log file PewinSessionLog.txt (saved in the application folder). 
  This is done to monitor any error that may come across during that session, 
  e.g., watchdog tripping, Communication timeout etc. This option can be enabled
  and time interval can be set in the in the General Setup and Options' 
  "View" tab.


New screens added:
1.Modbus configure window:
  This screen allows to configure/reconfigure modbus for PMACs the Modbus option 
  present. Modbus option is available on request on new UMACs (version 1.940 and
  later and on newer GeoPMACs. Modbus require a USB or Ethernet mode of 
  communication. While basic configuration can be done via Serial/ISA/PCI, the 
  counters cand Client Server configuration require USB/Ethernet mode of 
  communication. See Pewin32Pro2 manual for detailed description. Modbus setup 
  screen is available form the configure menu.
2.MACRORingOrder is yet another configuruation screen designed to initiate the 
  MACRO Ring ASCII communication bewteen the Ring Controller and other Slave 
  stations and/or secondary Masters/Slaves. This screen allows to setup Ring 
  Controller, detect or reinitialize all other stations on the Ring, sets up 
  all the commincation parametes, saves these parameters in a file and can 
  start/stop MACRO Ring ASCII communication to any station on the Ring. 
  See Pewin32Pro2 manaul for details. This screen is also available at the end
  of Configure menu.
3.C.S. Axis Jog: At the request of one of our customer, this screen has been
  added in the view menu. This screen has CS definitions and can Jog an axis in
  both absolute as well as incremental mode using the command !X where X is the
  defined Axis in a given C.S. This screen is abalable for Turbo PMACs only. 
  It parameters as same as Jog Ribbon for a specific motor.
4.PMAC CPU Resources: Like C.S. Axis Jog, this screen is also available for
  Turbo PMACs only. This screen can be launched from PMAC resources menu and 
  it lists different frequencies of the PMAC along with its Firmware version and
  CPU type. This is a standard MDIChildThread form and polls PMAC on the 
  specified interval for different Foregroung Tasks. Three FG task categories 
  include Phase Tasks, Servo Tasks and RTI Tasks. Details of all of the FG tasks
  are available from the specific buttons.
5.Memory resources: This screen lists special Memory registers in all PMACs and
  lists then in the order they are stored in the PMAC memory. The special memory
  registers include Gather buffer, User buffer, Rotary program buffer, Lookahead
  buffer and different Comp tables buffers. This screen can be launced from PMAC
  resources menu.
6.Frequncy calculators: Frequency calculators are available for PMAC2 style 
  (Turbo or Non-Turbo) boards. This can calculate Hardware Clock, Servo 
  Frequency, PFM for Steppers and I^2T parameters for a specific motor. This 
  screen is abailable under the PMAC resources menu.
7.Test DPRAM: DPRAM test is now a part of Pewin32Pro2 main application. It is 
  available under Tools menu.
8.Under Tools menu there are three additions applications.
  a) Basic Speed Test provides Benchmark times for Delta Tau Drivers for all 
     modes of communication.
  b) RawTerminal is degined for diagnostic purpose and returns the raw data 
     from the PMACs and displays it in the its screen. Both applications support
     download file as well events generated by PcommServer.
  c) Geo Brick Setup sets up the Geo Brick.

9.Driver installation and troubleshooting prcedure has changed. Please read the 
  Driver Installation notes from the Help menu for details.
10.In the help menu two links provided:
  a) The first link (Bug Reporting) is meant for reporting software bugs, 
     e.g., issues related to communication to PMAC and other software 
     applications related issues.
  b) The second link (Technical Support) is meant for general Delta Tau products 
     related questions and connects the user to Delta Tau main support website.


/////////////////////////////////////////////////////////////////
************************ KNOWN BUGS *****************************
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\



*************** Wish List ******************



*************** Bug Fixes ******************
Download Driver Pack

How To Update Drivers Manually

After your driver has been downloaded, follow these simple steps to install it.

  • Expand the archive file (if the download file is in zip or rar format).

  • If the expanded file has an .exe extension, double click it and follow the installation instructions.

  • Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.

  • Find the device and model you want to update in the device list.

  • Double-click on it to open the Properties dialog box.

  • From the Properties dialog box, select the Driver tab.

  • Click the Update Driver button, then follow the instructions.

Very important: You must reboot your system to ensure that any driver updates have taken effect.

For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.