Tbrevision.txt Driver File Contents (PMAC_20Executive_20Pro2_20Suite.zip)

TurboSetup:

ver 4.X
  . Communicate with PmacServer.exe
  . Geo MACRO Ring Order Support

ver 3.0


Ver 1300
  . Fix the bug related Baldor station
  . Fix Serial Com problem in the Terminal Window
  . Debut Command Center Feature
  . Support Multiple PMACs

Ver 1210
  .Bypass Win98 "out of resource" bug
  .Work in European Window

Ver 1110
  .Add Support for Baldor Macro Station (maximum 32 stations)
  .More efficient and robust watch window and real time trace function


Ver 1080
  . New installation files. Fix the conflict between PmacPlot and TurboSetup.
  . Fix static tracing plot problem in watch window (no plot came out when maximum = minimum).
  . Better screen arrangement so that users can reduce the Setup program window size.
  . Users can launch PmacPlot and PmacEditor from within TurboSetup.
  . 16 MACRO stations are supported.
  . Handle version incompatiability for firmware.
  . Work with regular PMAC UltraLite. 
  . New software commands for MACRO station:
      Ex: 1.set up global I-var in station 0,
           _S0,i5           (equivalent to MS ANYNODE,i5)
          2.set up Node specific I-var,
         _S4C1,i910=$7       (station 0, channel 1 i910=$7
                            (equivalent to MS NODE,i910=$7)


Ver 1070 
  . Major software upgrades according to Borland's latest release.
  . New installation files. The installation program will provide 
    some important info to the user, like backward compatibility 
    infomation. Also, the new installation program fixs the bug that 
    TurboSetup would not be installed to the location specified by user.

  . Bug fix: _trace("rhx:$AE") will now be read as a hex value.
  . Support new firmware auto-gatearray detection feature.
  . Support 3U Turbo.
  . _trace command also works in Simulation Mode.
  . More precise calculation on I2T protection.
    I2T step is also moved from step 11 to Step 15 in the AC-induction motor case
  . Automatically handle the differences between 
    new firmware (1.934) and old ones even though we do warn people
    about that this version of setup requires new firmware version.
  . Check obsolete commands for backward compatibility.
    ex: If user has firmware version older than 1.934, Terminal window would 
        allows him to set I65, i66 i67 i69. But If the user has newer firmware
        and he try to set I65 in the terminal window, a "obsolete command" 
        message will show up.
 
  . Support Acc 8D (sinusoidal encoder interpolator).
  . A new software command created, 
          _#X$  (X : motor number, ex _#1$)
    Valid usage of this software command:
    1. _#1$   (phase motor 1 using default magnitude and pause time)
    2. _#1$(1000)   (phase motor 1 using Ix79=1000 and default pause time)
    3. _#1$(1000,4) (phase motor 1 using Ix79=1000 and pause 4 seconds between steps) 


Ver 1060
  Improve installation and uninstallation processes of TurboSetup.


Ver 1050 
  Fix the bug that setup program may not determinte correct encoder polarity
  (I7mn0) after voltage six step.

 
Ver 1042 
  Fix Acc24 P1's  Ix83 setting.

Ver 1041
  Fix Auto Tuner time out error  for Turbo-PMAC1 type.
 
Ver 1040 (6-23,99)
   New features:
     1. Real time tracing and plotting. In addition to the "static" trace capability in 
           watch window, now TurboSetup support a "dynamic" real time tracing 
            and plotting. Ex. Open up terminal window, and type in :

            _trace(#1p)

         A real time plot window will pop up and display motor number 1 position.
          To trace multiple items like P100, M100, and Q100, type in 
  
              _trace(P100, M100, Q100)

      2. Motor Status display is now available in TurboSetup. 
          The position window, watch window, motor status window, and real-time 
          tracing of TurboSetup not just work with Turbo-PMAC, they all also work 
          with regular PMACs.


Ver 1030
    1. Position display window.
    2. Watch window with trace capability. Users can choose up to 8 items to trace. After tracing ended, users can plot those traced items to see their change in values.
    3. Improved terminal window. A user can hit up-arrow key to repeat previous commands.
    4. A smarter dry run mode. This is my first step to build a simulator for Setup program. Now you can use Terminal window in dry run mode. It means you can change or set a I-variable, P-variable, M-variable and so on in Terminal window and Setup program will automatically respond to the user's change as if there was a PMAC. It would be a good tool for a new PMAC user to learn PMAC without any piece of hardware needed.  
    5. A few bugs are fixed.


Ver 1022
1. Watch Window is added.
2. Enable "Skip" mode.

Ver 1021 
1. Position Window is added.
2. Smart Dry run mode.


Ver1019
1. Relax the Max Phase Freq Limit and provide more
   acurate freq calculations.

2.  Do not overwrite the original setting I6841. I70, I71

3. If user abort current loop six step, Ix79 Ix29 will not be
    set to zero ,  instead, they will  be retained their original value.

4. Macro stations maximum is increased to 6.


Ver 1018
1. Tuning AC-Induction motor on MACRO RING


Version 1015
1.Check "Digital" or Analog at start up
2. Check On Macro or not at starup
3. Check motor type (AC or DCBL) at startup
4. Finish Hall Effect Sensor calbration.


Download Driver Pack

How To Update Drivers Manually

After your driver has been downloaded, follow these simple steps to install it.

  • Expand the archive file (if the download file is in zip or rar format).

  • If the expanded file has an .exe extension, double click it and follow the installation instructions.

  • Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.

  • Find the device and model you want to update in the device list.

  • Double-click on it to open the Properties dialog box.

  • From the Properties dialog box, select the Driver tab.

  • Click the Update Driver button, then follow the instructions.

Very important: You must reboot your system to ensure that any driver updates have taken effect.

For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.

server: web4, load: 1.19