ISMREADME.TXT Driver File Contents (storman.zip)

--------------------------------------------------------------------
README.TXT

ICP Storage Manager (ISM)
as of November 19, 2004
--------------------------------------------------------------------
Please review this file for important information about issues
and erratas that were discovered after completion of the standard
product documentation. In the case of conflict between various
parts of the documentation set, this file contains the most
current information.

The following information is available in this file:

I.) Important information - please read before using/installing ISM

   1. General Cautions and Notes 
      1.1 Critical
      1.2 Informational
      1.3 Concerning this Document 
   2. Supported Controllers and Firmware Releases
   3. Known Limitations
   4. Supported Operating Systems
   5. Status of Physical Disks and Logical Devices differ between 
      ISM and icpcon 
   6. Contact Information

II.) General Information

   1. Software Versions and Documentation
      1.1   ICP Storage Manager
      1.2   Documentation
   2. Installation and Setup Notes
      2.1   Supported Operating Systems
      2.2   System Requirements
      2.3   Setup Notes
   3. General Cautions and Notes
      3.1   General Cautions
      3.2   General Notes
   4. Array Level-Specific Notes
      4.1   RAID 10 Notes
   5. Operating System-Specific Issues and Notes
      5.1   All
      5.2   Windows - All
      5.3   Windows 2000
      5.4   Linux


--------------------------------------------------------------------

I.) Important information - please read before using/installing ISM


1. General Cautions and Notes

  1.1 Critical

      - Use icpcon, ICP Storage Manager or ICP RAID Navigator separately! 
        Do NOT run multiple configuration tools in parallel! 
        Doing so may cause unpredictable results.

      - Do not use/install parallel to Adaptec Storage Manager (ASM). 
        If Adaptec controllers are used in the same system only use icpcon
        and do not install ISM on this system!
        Doing so may cause unpredictable results.

      - Do not use the aacli tool with RAIDYNE based ICP RAID controllers
        (e.g. GDT8500RZ, GDT85x6RZ, GDT8x14RZ, GDT8x24RZ, GDT8x22RZ).
        Doing so may cause unpredictable results.


  1.2 Informational
  
      - Detailed documentation of the program can be found under help.
        Note: not all features may apply to your controller.

      - The Host Drives of icpcon are called Logical Devices within ISM 

      - The array 'Build' process in icpcon is called 'Verifying' in ISM 

      - Hot Fix drives are called Hot Spare in ISM 

      - Repair of RAID1 and RAID5 arrays can be done by using the auto 
        hotplug feature or by adding a Hot Spare drive to the appropriate array.

      - After any action taken in ISM it is recommended to manually refresh the
        displayed information.

      - If a RAID1+"Hot Spare" is being built, the messages "Verify failed..." 
        followed by "Verify started..." are generated. This is an expected 
        behaviour related to internal funtions of the controller firmware.


  1.3 Concerning this Document 

      - Unlike the information below, it is NOT possible to migrate from
        RAID1 to a striped RAID level (RAID5, RAID0, RAID10) and vice versa. 

      - Unlike the information below, a browser based version of the
        ICP Storage Manager is NOT available.

      - Unlike the information below, it is NOT possible to define a single 
        hard disk for several RAID arrays and logical volumes respectively.

 
2. Supported Controllers and Firmware Releases

      - The following controllers running FW 2.44.00 or higher are supported 
        with this release of ISM:

        GDT8500RZ, GDT8546RZ, GDT8586RZ, GDT8114RZ, GDT8124RZ, GDT8514RZ, 
        GDT8524RZ+, GDT8524RZ+BBU, GDT8522RZ, GDT8622RZ 


3. Known Limitations

      - Deleting splitted Host Drives is not possible - use icpcon instead. 
  
      - Expand, Migrate and Merge are not possible - use icpcon instead. 

      - Cluster Functions are not supported - use icpcon instead. 

      - SNMP notification is not supported - use ICP SNMP subagent instead.

      - ISM will not be installed into the same path as the ICP Tools.

      - Hotfix Drives of Splitted Host Drives will be assigned to the first
        Host Drive number of the splitted parts only.
  
      - ISM allows to create Host Drive with up to max. 2048GB (2TB).
        Larger arrays can be created with icpcon.

      - Fibre Channel transfer rate is being displayed as SCSI transfer rate.

      - If a drive fails during RAID5 build, the build progress counter
        shows '0% Verifying' though the build process has been canceled.

      - A scheduled RAID5 verification does not start on Windows systems
        if the array is connected to controller 2. It works correctly if the
        array is connected to controller 1 and/or if only one controller is
        installed.

      - The drive number of a logical drive can not be changed as known from 
        icpcon's 'Swap Host Drives' feature.

      - ISM only supports blinking of physical drive LEDs when SAFTE processor 
        is available (i.e. in intelligent hot-plug backplanes). If no SAFTE 
        device is available on the channel the disk is connected to the blink 
        function does not work. Use the "F5: Identify Drive" function of 
        icpcon instead.

      - Though it is possible to add a Hot Spare drive to a single volume and 
        non-redundant arrays (e.g. RAID0), this does not add redundancy features
        to these volumes. The Hot Spare disk will NOT be used for these drives.

      - SCSI SAFTE devices are listed on Channel 0 with ID 0 if the SAFTE device
        can not be addressed correctly by the controller. Always verify the 
        coordinates of SAFTE devices with icpcon.

 
4. Supported Operating Systems 

      - The following OS versions are supported with this release of ISM: 

        o Windows 2000
        o Windows 2003 32-bit only
        o SuSE Linux Enterprise Server 9.0 x86 

        This version of ISM only runs on 32-bit OS versions. 
        Do NOT install on 64-bit versions. 


5. Status of Physical Disks and Logical Devices differ between ISM and icpcon 

   Drive      icpcon state           ISM state
   ------------------------------------------------------------------------------
   Single         ready               optimal
   Single         fault               failed
   RAID 0         ready               optimal
   RAID 0         error               failed
   RAID 1         build               veriyfing (degraded in properties)
   RAID 10        build               veriyfing (optimal in properties)
   RAID 1/10      ready               optimal
   RAID 1/10      fail                degraded
   RAID 10        error               failed
   RAID 4/5       idle                verifying (degraded in properties)
   RAID 4/5       build               verifying (optimal in properties)
   RAID 4/5       ready               optimal
   RAID 4/5       fail                degraded
   RAID 4/5       rebuild             rebuilding
   RAID 4/5       error               failed
   RAID 4/5       idle/patch          verifying (failed in properties)
   RAID 4/5       ready/patch         optimal
   RAID 4/5       fail/patch          degraded
   RAID 4/5       error/patch         failed
	
   Expand add disk

   RAID 4/5       expand/ready        reconfiguring
   RAID 4/5       expand/fail         reconfiguring (degraded reconfiguring in properties)
   RAID 4/5       expand/rebuild      reconfiguring (degraded reconfiguring in properties)

   Expand use free capacity

   RAID 4/5       build               verifying
   RAID 4/5       idle                verifying (degraded in properties)
   RAID 4/5       build/patch         verifying 


6. Contact Information

  6.1 ICP sales

      Contact ICP sales:
      +49-(0)89-45 64 06 21

      icp_sales@adaptec.com


  6.2 ICP online support

      ICP vortex home page:
      http://www.icp-vortex.com

      ICP products:
      english - http://www.icp-vortex.com/english/product/prod_e.htm
      deutsch - http://www.icp-vortex.com/german/product/prod_d.htm

      ICP support:
      english - http://www.icp-vortex.com/english/support/supp_e.htm 
      deutsch - http://www.icp-vortex.com/german/support/supp_d.htm 


====================================================================

II.) General Information


1. Software Versions and Documentation

   1.1. ICP Storage Manager Version 2.12.00

   1.2. Documentation on this CD

        -  ICP Storage Manager Online Help
        
        -  ICP Storage Manager README.TXT file


--------------------------------------------------------------------
2. Installation and Setup Notes

   - The ICP SATA and SCSI RAID Controllers Installation and 
     User's Guide contains complete installation information for the
     controllers and drivers, as well as complete instructions for 
     all utilities and ICP software.
     
   2.1 Supported Operating Systems 
   
     ... please note 4. in previous chapter I.)

   2.2   System Requirements

     o  Intel Compatible 500 MHz processor
     o  256 MB RAM
     o  35 MB hard disk drive space
     o  256 color video mode
   
   2.3 Setup Notes

   - Do not attempt to install ICP Storage Manager version 2.10.00
     on a system that already has ICP Storage Manager version
     2.12.00 installed.

   - To install ICP Storage Manager on Red Hat Enterprise Linux AS 3,
     you must install two packages from the Red Hat installation CD:
     
     o  compat-libstdc7.3-2.96.122.i386.rpm
     o  compat-libstdc-devel-7.3-2.96.122.i386.rpm
                   
     NOTE:  The version string in the file name may be different 
            than above; be sure to check the version string on the 
            Red Hat CD.
     
     For example, type:
            
     rpm --install /mnt/compat-libstdc7.3-2.96.122.i386.rpm
            
     where mnt is the mount point of the CD-ROM drive.            

   - To run ICP Storage Manager under Red Hat Enterprise Linux
     AS 3 Quarterly Update 3 for AMD64, you must add the 
     'noexec32=off' argument to the boot kernel command line.   
     Then, restart the system.
  
   - You can configure ICP Storage Manager settings on other 
     servers exactly as they are configured on one server.  To  
     replicate the ICP Storage Manager tree, notification list,  
     and security list, do the following:

     1.  Install ICP Storage Manager on one server.

     2.  Start ICP Storage Manager. Using the 'Add remote system' 
         action, define the servers for your tree.

     3.  Open the Notification Manager. Using the 'Add system' 
         action, define the notification list.

     4.  Open the Security Manager. Using the 'Add user' action, 
         define the security list.

     5.  Exit ICP Storage Manager.

     6.  Copy the following files onto a diskette from the directory
         where the ICP Storage Manager is installed:

         RaidMSys.ser --> to replicate the tree
         RaidNLst.ser --> to replicate the notification list
         RaidSLst.ser --> to replicate the security list
         RaidJob.ser  --> to replicate the jobs in the Task Scheduler

     7.  Install ICP Storage Manager on the other servers.

     8.  Copy the files from the diskette into the directory where
         ICP Storage Manager is installed on the other servers.

   - ICP Storage Manager can monitor status information returned    
     from certain enclosures. If there are any problems, information    
     such as fan status, power supply status, and temperature status  
     is collected and reported in the event viewer.

     To monitor an enclosure, do the following:

     1.  Write down the description displayed in the 'Product or
         Model Number' field of the enclosure device information panel.
    
     2.  Exit ICP Storage Manager.

     3.  Using a text editor, open the RaidDev.pps file.  This file
         is in the directory where ICP Storage Manager is
         installed.

     4.  Using the enclosure description from step 1, add a line to 
         the file.  For example, if the description is 3520EX10, add 
         the following:
    
         3520EX10=true
    
     5.  Save and close the file.

     6.  Restart ICP Storage Manager.


--------------------------------------------------------------------
3. ICP Storage Manager Cautions and Notes

   3.1 General Cautions

   - While an array is being built or cleared, do not remove and 
     reinsert any drive from that array. Doing so may cause 
     unpredictable results for any of the controller's arrays.
     
   - While a drive is being cleared, do not try to include it in a
     new array. Doing so may cause unpredictable results.

   - Do not move drives containing an array or volume from one 
     controller to another while the power is on. Doing so could 
     cause the loss of the array configuration or data, or both. 
     Instead, power off both affected controllers, move the drives, 
     and then restart.

   - Do not run ICP Storage Manager concurrently with the CLI. Doing 
     so may cause unpredictable results.

   3.2 General Notes

   - ICP Storage Manager requires that the following range of ports 
     be open for remote access: 34571 - 34575.

   - You can run ICP Storage Manager from a browser only under  
     Windows operating systems using Microsoft Internet Explorer 5.5  
     and later. The standalone GUI is supported under all supported 
     operating systems.

   - To run ICP Storage Manager in a browser, your network's DNS 
     configuration must have matching forward and reverse lookups.   
     Point your browser to http://yourcomputername:34572. 

   - ICP Storage Manager generates log files automatically to
     assist in tracking system activity.  The log files are
     created in the directory where the ICP Storage Manager is
     installed.  
   
     o RaidEvt.log  - Contains the information reported in the
                      ICP Storage Manager event viewer for all
                      local and remote systems.

     o RaidEvtA.log - Contains the information reported in the
                      ICP Storage Manager event viewer for the
                      local system.
                       
     o RaidNot.log  - Contains the information reported in the
                      Notification Manager event viewer.
                       
     o RaidSec.log  - Contains the information reported in the
                      Security Manager event viewer.
                       
     o RaidErr.log  - Contains Java messages generated by 
                      ICP Storage Manager.
                    
     o RaidErrA.log - Contains Java messages generated by the
                      ICP Storage Manager agent.
                      
     Information written to these files is appended to the existing
     files to maintain a history.  However, if any of the files reach
     a size of 200,000 bytes, the file is copied to a new file with 
     the extension .OLD and the original (that is, the LOG file) is 
     deleted and recreated.  If a .OLD file already exists, the 
     existing .OLD file is destroyed.

   - The blink LED feature is supported only in SAF-TE enabled 
     enclosures.
   
   - Performing a Verify and Verify/Fix on an RAID 10 displays the same 
     message text in the event log, something like, "Build/Verify 
     started on second level array of array 'Array_0.'" You may see the 
     message three times for a Verify, but only once for a Verify/Fix.

   - Task priority is not retained after rebooting. If you change
     a priority to LOW or MEDIUM, and reboot, the controller resets the
     priority to the default (HIGH).

   - When an array fails, the array name returns to its default name.

   - When displaying information on a physical device, the device, 
     vendor and model information may be displayed incorrectly.

   - During array migration from a RAID 1 or RAID 5 to a RAID 0, if 
     the original array had a spare drive attached, the resulting 
     RAID 0 retains the spare drive. 

   - After building or verifying a leg of a second-level array, the 
     status of the second-level array is displayed as a "Quick 
     Initialized" array.

   - After using a hot spare to successfully rebuild a redundant 
     array, information about the hot spare drive may not display 
     as expected. ICP Storage Manager may continue to display 
     it as a global hot spare.  
     

--------------------------------------------------------------------
4. Array Level-Specific Notes

   4.1 RAID 10 Notes

   - You cannot change the priority of a RAID-10 verify. Setting
     the priority at the start of a verify has no effect. The
     priority is still shown as high. Changing the priority of
     a running verify on a raid-10 changes the displayed priority
     until a rescan is done, then the priority shows as high again.

   - Performing a Verify and Verify/Fix on an RAID 10 displays the 
     same message text in the event log, "Build/Verify started on 
     second level array of array 'Array_0.'" You may see the message 
     three times for a Verify, but only once for a Verify/Fix.

   - During a migration from a RAID 0 to any redundant array like 
     RAID 1, 5, or 10, ICP Storage Manager shows the status as  
     "Degraded Reconfiguring" for a moment, then the status changes  
     to "Reconfiguring." The "Degraded" status does not appear in the 
     event log.


--------------------------------------------------------------------
5. Operating System-Specific Issues

   5.1 All
  
   - ICP Storage Manager will not start on a system that is using
     only 16 colors. ICP Storage Manager supports a minimum of 256 
     colors. You must switch the video mode from 16 colors to a mode 
     with at least 256 colors.

   - If the ICP Storage Manager console does not repaint correctly,
     select the View->Refresh menu item to repaint the screen.       

   5.2 Windows - All
  
   - To run ICP Storage Manager in a browser, your network's  
     DNS configuration must have matching forward and reverse 
     lookups.
         
   - The Java Virtual Machine has a problem with the 256-color 
     palette. (The ICP Storage Manager display may be distorted 
     or hard to read.) Set the Display Properties Settings to a  
     color mode with greater than 256 colors. 
  
   - When you shut down Windows, you might see the message 
     "unexpected shutdown". Windows displays this message if the
     ICP Storage Manager  Agent fails to exit within 3 seconds. 
     It has no affect on file I/O or other system operations and can
     be ignored.        

   5.3 Windows 2000

   - More event notifications are generated than arrays degraded.        
     For example, in a configuration with four RAID 5s sharing 
     three drives, one failed drive causes six notifications--one for 
     each of the arrays affected, plus two extra for the second array.
     
   5.4 Linux

   - When you delete an array, the operating system can no longer see
     the last array. WORKAROUND: To allow Linux to see the last array, 
     restart your system.

   - The controller does not support attached CD drives during OS 
     installation.

   - If you cannot connect to a remote ICP Storage Manager  
     installed on a Linux system, verify that the TCP/IP hosts file  
     is configured properly.
      
     1.  Open the /etc/hosts file.
       
         NOTE:  The following is an example:
           
                127.0.0.1 localhost.localdomain localhost matrix
       
     2.  If the hostname of the system is identified on the line
         with 127.0.0.1, you must create a new host line.
       
     3.  Remove the hostname from the 127.0.0.1 line.
       
         NOTE:  The following is an example:
           
                127.0.0.1 localhost.localdomain localhost

     4.  On a new line, type the IP address of the system.
       
     5.  Using the Tab key, tab to the second column and enter the 
         fully qualified hostname.
           
     6.  Using the Tab key, tab to the third column and enter the 
         nickname for the system.
           
         NOTE:  The following is an example of a completed line:

                1.1.1.1 matrix.localdomain matrix
                  
                where 1.1.1.1 is the IP address of the server and
                matrix is the hostname of the server.
           
     7.  Restart the server for changes to take effect.
              
   - On certain versions of Linux, you may see messages concerning font 
     conversion errors. Font configuration under X-Windows is a known 
     JVM problem. It does not affect the proper operation of the  
     ICP Storage Manager software. To suppress these messages,  
     add the following line to your .Xdefaults file:
       
     stringConversionWarnings: False
                     
   - Some pop-up identification boxes include complete window frames   
     when running the ICP Storage Manager in bootable-CD mode. 
     These pop-ups may run off the side of the screen due to the
     extra width of the window frame. This is a known problem of the
     fvwm window manager on the CD.
                                 
   - On rare occasions, the online help system may generate a Java 
     exception. This is due to a known problem in the HTML rendering 
     section of JFC/Swing.                               
  

--------------------------------------------------------------------
(c) 2004 Adaptec, Inc. All Rights Reserved.  This software contains the 
valuable trade secrets of Adaptec or its licensors. The software is 
protected under international copyright laws and treaties. This software 
may only be used in accordance with the terms of its accompanying license 
agreement. No part of this publication may be reproduced, stored in a 
retrieval system, or transmitted in any form or by any means, electronic, 
mechanical, photocopying, recording or otherwise, without prior written 
consent of Adaptec, Inc., 691 South Milpitas Blvd., Milpitas, CA 95035.
Download Driver Pack

How To Update Drivers Manually

After your driver has been downloaded, follow these simple steps to install it.

  • Expand the archive file (if the download file is in zip or rar format).

  • If the expanded file has an .exe extension, double click it and follow the installation instructions.

  • Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.

  • Find the device and model you want to update in the device list.

  • Double-click on it to open the Properties dialog box.

  • From the Properties dialog box, select the Driver tab.

  • Click the Update Driver button, then follow the instructions.

Very important: You must reboot your system to ensure that any driver updates have taken effect.

For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.

server: web2, load: 0.78