ÉÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ» º º º Compex ENET32-VL Ethernet Network Adapter º º (C) Copyright PDS, 1995. All Rights Reserved. º º º ÈÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍͼ The Compex Ethernet RPL Boot PROM described here follows IBM Remote Program Loader (RPL) protocol, which supports NetWare 3.x, 4.x, Microsoft LAN Manager 2.x and IBM LAN Server 3.x. and 4.x The 3 sections in this document describe how to install the necessary software in a Novell NetWare, Microsoft LAN Manager or IBM LAN Server environment. SECTION 1 : Installing in a Novell NetWare environment ========================================== This installation guide describes how to install the Novell NetWare Remote Program Load (RPL) software on the NetWare 386 3.11, 3.12, 4.0x or 4.10 server. INSTALLATION INSTRUCTIONS FOR NetWare 386 3.11 SERVER To install the Novell NetWare RPL software on the NetWare 386 3.11 server: 1. Load EN32VL.LAN using the 802.2 frame type. 2. Bind IPX to EN32VL.LAN. 3. Load Novell's RPL Protocol Stack "RPL.NLM" on the server. 4. Bind RPL to EN32VL.LAN. 5. Follow Novell's instructions to build the NET$DOS.SYS, then copy it into the \LOGIN subdirectory on the file server. Workstations configured with the Compex RPL ROM can now boot remotely from the server. INSTALLATION INSTRUCTIONS FOR NetWare 386 3.12 or 4.xx SERVER To install the Novell NetWare RPL software on the NetWare 386 3.12 or 4.xx server: 1. Load EN32VL.LAN using the 802.2 frame type. 2. Bind IPX to EN32VL.LAN. 3. Load Novell's RPL Protocol Stack "RPL.NLM" on the server. This file is shipped together with Novell NetWare 386 4.xx. For NetWare v4.10, read text file for fixes in \RPL\NW402 directory. 4. Bind RPL to EN32VL.LAN. 5. Follow Novell's instructions to build the NET$DOS.SYS, then copy it into the \LOGIN subdirectory on the file server. Workstations configured with the Compex RPL ROM can now boot remotely from the server. SECTION 2 : Installing in a Microsoft LAN Manager environment ================================================= The procedures described here assumes that you have already added remote boot support for your Microsoft LAN Manager environment. If you don't have remote boot support in your LAN Manager, refer to Microsoft LAN Manager Administrator's Guide Chapter 13: Booting Workstations Remotely. Follow the steps to setup the remote boot environment, but do not use the RPLMGR.EXE program to create a remote boot profile. 1. Select an OS/2 full screen. Make C:\LANMAN\RPL the default directory. 2. Copy EN32VL.DOS to BBLOCK\NDIS 3. Create a subdirectory BBLOCK\NETBEUI\EN32VL 4. Create DOSBB.CNF and PROTOCOL.INI files in BBLOCK\NETBEUI\EN32VL as shown below: BBLOCK\NETBEUI\EN32VL\DOSBB.CNF: ; ; DOS on Compex ENET32-VL Ethernet network adapters ; BASE D0H RPL BBLOCK\RPLBOOT.SYS LDR BBLOCK\RPLSTART.COM ~ DAT BBLOCK\NETBEUI\EN32VL\PROTOCOL.INI DRV BBLOCK\RPLDISK.SYS ~ 4 M EXE BBLOCK\RPLPRO1.COM ~ 2 ~ EXE BBLOCK\RPLBIND2.EXE ~ ~ EXE BBLOCK\PROTMAN.EXE ~ ~ EXE BBLOCK\RPLBIND1.EXE ~ ~ EXE BBLOCK\NETBEUI\NETBEUI.EXE ~ 10 ~ DRV BBLOCK\NDIS\EN32VL.DOS ~ 9 ~ DRV BBLOCK\PROTMAN.DOS /I:C:\LANMAN.DOS ~ M BBLOCK\NETBEUI\EN32VL\PROTOCOL.INI: [protman] drivername = protman$ dynamic = yes priority = netbeui [netbeui_xif] drivername = netbeui$ bindings = EN32VL_nif names = 6 ncbs = 8 packets = 20 pipeline = 10 sessions = 4 stacksize = 512 lanabase = 0 [xnsnb_xif] drivername = xnsnb$ bindings = EN32VL_nif load = xnsnb[cbr] lanabase = 1 [xnstp_xif] drivername = xnstp$ bindings = EN32VL_nif load = xnstp[ub] lanabase = 1 [tcpip_xif] drivername = TCPIP$ ipaddress0 = (TCPIP_ADDRESS) subnetmask0 = (TCPIP_SUBMASK) defaultgateway0 = (TCPIP_GATEWAY) nbsessions = 6 load = tcptsr[c],tinyrfc[c],emsbfr[cr] unload = "unloadt /notsr[dc]" bindings = EN32VL_nif lanabase = 1 [ipx_xif] drivername = ipx$ load = ipxmark[u],ipx[u] unload = ipxrel[c] bindings = EN32VL_nif lanabase = 1 [dlc_xif] drivername = dlc$ bindings = EN32VL_nif load = dlc[cb] unload = dlc[u] lanabase = 1 [EN32VL_nif] drivername = EN32VL$ 5. Edit the RPL.MAP in the current directory. Add this line below the description of "boot block records" yyyyyyyyyyyy BBLOCK\NETBEUI\EN32VL\DOSBB.CNF 2 6 A ~ DOS~EN32VL~Ethernet 008048 ~ ,,, ~ RDOS ~ ~ ~ ~ ~ ~ Insert the lines before the description of "profile and workstation records added by rplmgr" 008048?????? ???????? D FITS\DEFAULT (RPL_SERVER_NAME) S ~ ~ ~ ,,, ~ RDOS ~ DEFAULT *~New~Compex~EN32VL~Ethernet~* ~ ~ ~ 6. Edit the RPLMGR.INI in the current directory. Insert the following section before the OS/2 description block. [configuration] name = DOS330E os = DOS330 dirname = DOS dirname2 = DOS330 bblink = RDOS fitfileshared = fits\dos330 fitfilepersonal = fits\dos330p comment = DOS 3.30 Compex ENET32-VL adapter = 008048?????? [configuration] name = DOS401E os = DOS401 dirname = DOS dirname2 = DOS401 bblink = RDOS fitfileshared = fits\dos401 fitfilepersonal = fits\dos401p comment = DOS 4.01 Compex ENET32-VL adapter = 008048?????? [configuration] name = DOS500E os = DOS500 dirname = DOS dirname2 = DOS500 bblink = RDOS fitfileshared = fits\dos500 fitfilepersonal = fits\dos500p comment = DOS 5.00 Compex ENET32-VL adapter = 008048?????? And append the following line to RPLMGR.INI ; 008048 = Compex (Ethernet) 7. Logon to the network as an administrator. Stop the remote boot service by typing NET STOP REMOTEBOOT. Next, run RPLINST and then restart remote boot service by typing NET START REMOTEBOOT. 8. Refer to the Chapter 13 of LAN Manager Administrator's Guide. Follow "Managing Remote Boot" to generate a workstation profile. SECTION 3 : Installing in a IBM LAN Server environment ========================================== The procedures described here assumes that you have already added remote boot support for your IBM LAN Server 3.0 environment. If you don't have remote boot support in your LAN Server, refer to IBM OS/2 LAN Server Version 3.0 Volume 1: Planning and Installation. 1. Select an OS/2 Full Screen and change the current directory to C:\IBMLAN\RPL. 2. Login as Administrator and stop the remote boot service (if it is running) by typing NET STOP REMOTEBOOT. 3. Copy EN32VL.DOS to DOS directory. 4. Create a subdirectory DOS\EN32VL 5. Create PROTOCOL.INI file in DOS\EN32VL as shown below: DOS\EN32VL\PROTOCOL.INI [PROTMAN_MOD] DriverName = PROTMAN$ [NETBEUI] Drivername = netbeui$ Bindings = EN32VL_MOD [ENEFLT_MOD] DriverName = EN32VL$ 6. Create a EN32VL.CNF file in the current directory as shown below: ; ; DOS Boot Block Configuration (ENET32-VL Network adapter) ; NDIS LAN Support Program Drivers ; BASE 7C0H RPL DOS\RPLBOOT.SYS LDR DOS\RPLLOADR.COM ~ DAT DOS\LT2.MSG DAT C:\IBMLAN\DOSLAN\LSP\DXM.MSG DAT DOS\EN32VL\PROTOCOL.INI EXE C:\IBMLAN\DOSLAN\LSP\NETBIND.COM ~ ~ ~ DRV C:\IBMLAN\DOSLAN\LSP\DXMJ0MOD.SYS ~ 14 ~ DRV C:\IBMLAN\DOSLAN\LSP\DXMA0MOD.SYS 001 ~ ~ DRV DOS\EN32VL.DOS ~ 8 ~ DRV C:\IBMLAN\DOSLAN\LSP\PROTMAN.DOS /I: ~ ~ 7. Edit the RPL.MAP file in the current directory. Add these lines below the description of "server record fields". yyyyyyyyyyyy en32vl.cnf 3 10 N IBMLAN$ DOS~EN32VL~ETHERNET~NDIS ~ ~ ,,, Z R_DEN32VL_NDIS ~ ~ 8. Refer to LAN Server Network Administrator Reference Manual to create Remote IPL workstation records. 9. Start the remoteboot service by typing NET START REMOTEBOOT.Download Driver Pack
After your driver has been downloaded, follow these simple steps to install it.
Expand the archive file (if the download file is in zip or rar format).
If the expanded file has an .exe extension, double click it and follow the installation instructions.
Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.
Find the device and model you want to update in the device list.
Double-click on it to open the Properties dialog box.
From the Properties dialog box, select the Driver tab.
Click the Update Driver button, then follow the instructions.
Very important: You must reboot your system to ensure that any driver updates have taken effect.
For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.