[Msg] M0=The parameter setting of device D can not be in the special D range (1000~2000) M1=Start frequency should be less than target frequency M2=Gap frequency should be less or equal to (target frequency-start frequency) M3=Total number of pulse should be greater than (acceleration/deceleration pulse number*2) M4=Acceleration/Deceleration pulse number should be greater than acceleration/deceleration step M5=Possess output settings of acceleration/deceleration pulse: M6=Section M7=switch to section M8=This is acceleration switch, please confirm each field again. M9=This is deceleration switch, please confirm each field again. M10=, target frequency can not be equal to start frequency M11=, gap frequency of acceleration should be 1Hz~32700Hz M12=, gap frequency of deceleration should be -1Hz~-32700Hz M13=, output target number should be greater than (GF*GT/1000)*((TF-SF)/GF) M14=Acceleration/Deceleration pulse output settings of adjustable slope: M15=OK M16=Next M17=Setting range of constant K is K M18=Device number exceeds upper bound: M19=Wizard will not generate interrupt mark M20=Please add interrupt mark by yourself M21=otherwise system error will occur! M22=PWM instruction, pulse output time can not be greater than output cycle M23=PLSR instruction, setting range of max. output frequency is M24=PLSR instruction, setting range of total output pulse is M25=PLSR instruction, max. output pulse frequency error or total pulse setting error, M26=cause error result M27=PLSR instruction, setting range of acceleration/deceleration time M28=Target frequency can not be the M29=same as start frequency M30=Output frequency setting range: K1~K10,000Hz M31=Output frequency setting range: K1~K32,000Hz M32=Output frequency setting range: K1~K200,000Hz M33=Output pulse number setting range: K1~K32767 M34=Output pulse number setting range: K1~K2,147,483,647 M35=Pulse unit switch, when M1070=ON, unit is 100us, when M1070=OFF, unit is 1ms M36=Relative device M1258, the inverse of Y0 pulse output signal M37=Pulse unit switch, when M1071=ON, unit is 100us, when M1071=OFF, unit is 1ms M38=Relative device M1259,the inverse of Y2 pulse output signal M39=Setting range: K10~K32,767Hz, it must be the multiple of 10 M40=setting range: K110~K32,767 M41=Setting range: K10~K200,000Hz, it must be the multiple of 10 M42=Setting range: K110~K2,147,483,647 M43=Output setting of special high-speed pulse (50KHz): M44=Parameter of PLSR should be constant K when drawing timing diagram M45=Can not build the sharing memory M46=Setting range of constant H is H M47=Max. frequency of PLSR output M48=Total pulse number of PLSR outputDownload Driver Pack
After your driver has been downloaded, follow these simple steps to install it.
Expand the archive file (if the download file is in zip or rar format).
If the expanded file has an .exe extension, double click it and follow the installation instructions.
Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.
Find the device and model you want to update in the device list.
Double-click on it to open the Properties dialog box.
From the Properties dialog box, select the Driver tab.
Click the Update Driver button, then follow the instructions.
Very important: You must reboot your system to ensure that any driver updates have taken effect.
For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.