F12446_HPulse_Wizard.Txt Driver File Contents (wplsoft_v208_ENG_050512.zip)

[Msg]
M0=The parameter setting of device D can not be in the special D range (1000~2000)
M1=Start frequency should be less than target frequency
M2=Gap frequency should be less or equal to  (target frequency-start frequency)
M3=Total number of pulse should be greater than (acceleration/deceleration pulse number*2)
M4=Acceleration/Deceleration pulse number should be greater than acceleration/deceleration step
M5=Possess output settings of acceleration/deceleration pulse:
M6=Section
M7=switch to section
M8=This is acceleration switch, please confirm each field again.
M9=This is deceleration switch, please confirm each field again.
M10=, target frequency can not be equal to start frequency
M11=, gap frequency of acceleration should be 1Hz~32700Hz
M12=, gap frequency of deceleration should be -1Hz~-32700Hz
M13=, output target number should be greater than (GF*GT/1000)*((TF-SF)/GF)
M14=Acceleration/Deceleration pulse output settings of adjustable slope:
M15=OK
M16=Next
M17=Setting range of constant K is K
M18=Device number exceeds upper bound:
M19=Wizard will not generate interrupt mark
M20=Please add interrupt mark by yourself
M21=otherwise system error will occur!
M22=PWM instruction, pulse output time can not be greater than output cycle
M23=PLSR instruction, setting range of max. output frequency is
M24=PLSR instruction, setting range of total output pulse is
M25=PLSR instruction, max. output pulse frequency error or total pulse setting error,
M26=cause error result
M27=PLSR instruction, setting range of acceleration/deceleration time
M28=Target frequency can not be the
M29=same as start frequency
M30=Output frequency setting range: K1~K10,000Hz
M31=Output frequency setting range: K1~K32,000Hz
M32=Output frequency setting range: K1~K200,000Hz
M33=Output pulse number setting range: K1~K32767 
M34=Output pulse number setting range: K1~K2,147,483,647
M35=Pulse unit switch, when M1070=ON, unit is 100us, when M1070=OFF, unit is 1ms
M36=Relative device M1258, the inverse of Y0 pulse output signal
M37=Pulse unit switch, when M1071=ON, unit is 100us, when M1071=OFF, unit is 1ms
M38=Relative device M1259,the inverse of Y2 pulse output signal
M39=Setting range: K10~K32,767Hz, it must be the multiple of 10
M40=setting range: K110~K32,767
M41=Setting range: K10~K200,000Hz, it must be the multiple of 10
M42=Setting range: K110~K2,147,483,647
M43=Output setting of special high-speed pulse (50KHz):
M44=Parameter of PLSR should be constant K when drawing timing diagram
M45=Can not build the sharing memory
M46=Setting range of constant H  is H
M47=Max. frequency of PLSR output
M48=Total pulse number of PLSR output




Download Driver Pack

How To Update Drivers Manually

After your driver has been downloaded, follow these simple steps to install it.

  • Expand the archive file (if the download file is in zip or rar format).

  • If the expanded file has an .exe extension, double click it and follow the installation instructions.

  • Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.

  • Find the device and model you want to update in the device list.

  • Double-click on it to open the Properties dialog box.

  • From the Properties dialog box, select the Driver tab.

  • Click the Update Driver button, then follow the instructions.

Very important: You must reboot your system to ensure that any driver updates have taken effect.

For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.

server: web2, load: 1.03