F14507_EDevCmtInit_Eng.txt Driver File Contents (WPL209.zip)

[Version]=209

M1000::Normally open contact (a contact). This contact is ON when running and it is ON when the status is set to RUN.
M1001::Normally OFF contact (b contact). This contact is OFF in running and it is OFF when the status is set to RUN.
M1002::ON only for 1 scan after RUN. Initial pulse is contact a. It will get positive pulse in the RUN moment. Pulse width=scan period. 
M1003::Off only for 1 scan after RUN. Initial pulse is contact a. It will get negative pulse in the RUN moment. Pulse width=scan period.
M1004::Reserved
M1005::Reserved
M1006::Output frequency is 0 M1006=On
M1007::The operation direction of AC motor drives (FWD) M1007=Off¡A(REV) M1007=On
M1008::Reserved
M1009::Reserved
M1010::Reserved
M1011::10ms clock pulse, 5ms On/5ms Off
M1012::100ms clock pulse, 50ms On / 50ms Off
M1013::1s clock pulse, 0.5s On / 0.5s Off
M1014::1min clock pulse, 30s On / 30s Off
M1015::Frequency attained M1015=On
M1016::Parameter read/write error M1016=On
M1017::Succeed to write parameter M1017=On
M1018::Enable State of high-speed counter function (When M1028=On)
M1019::Reserved
M1020::Zero flag
M1021::Borrow flag
M1022::Carry flag
M1023::Divisor is 0
M1024::Reserved
M1025::RUN (ON) / STOP (OFF) the AC motor drive
M1026::The operation direction of the AC motor drive (FWD: OFF, REV: ON)
M1027::Reserved
M1028::Enable (ON)/disable (OFF) high-speed counter function
M1029::Clear the value of high-speed counter
M1030::Decide to count up (OFF)/count down (ON)
M1031::Reserved
D1000::Reserved
D1001::System program version (user can read PLC program version from this register. For example, D1001 = H XX10 means version 1.0
D1002::Program capacity
D1003::Sum of program memory
D1004::Reserved
D1005::Reserved
D1006::Reserved
D1007::Reserved
D1008::Reserved
D1009::Reserved
D1010::Present scan time (Unit: 0.1ms)
D1011::Minimum scan time (Unit: 0.1ms)
D1012::Maximum scan time (Unit: 0.1ms)
D1013::Reserved
D1014::Reserved
D1015::Reserved
D1016::Reserved
D1017::Reserved
D1018::Reserved
D1019::Reserved
D1020::AC motor drive Output frequency
D1021::AC motor drive Output current
D1022::The ID of the extension card:02 USB Card03 12.Bit A/D (2CH) 12.Bit D/A (2CH)04. Relay Card-2C05. Relay Card-3A06. 3IN/3OUT Card07. PG Card
D1023::Reserved
D1024::Reserved
D1025::The present value of the high-speed counter (low byte)
D1026::The present value of the high-speed counter (high byte)
D1027::Frequency Output of the PID control
D1028::The value of AVI (analog voltage input) 0-10V corresponds to 0-1023
D1029::The value of ACI (analog current input) 4-20mA corresponds to 0-1023 or the value of AVI2 (analog voltage input) 0-10V corresponds to 0-1023
D1030::The value of V.R digital keypad 0-10V corresponds to 0-1023
D1031::Reserved
D1032::Reserved
D1033::Reserved
D1034::Reserved
D1035::Reserved
D1036::AC motor drive error code
D1037::Reserved
D1038::Reserved
D1039::Reserved
D1040::Analog output value (0~65535) corresponds to 0~10V
D1041::Reserved
D1042::Reserved
D1043::User defined (when Pr.00.04 is set to 2, the register data will be displayed as C xxx)
D1044::High-speed counter mode
Download Driver Pack

How To Update Drivers Manually

After your driver has been downloaded, follow these simple steps to install it.

  • Expand the archive file (if the download file is in zip or rar format).

  • If the expanded file has an .exe extension, double click it and follow the installation instructions.

  • Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.

  • Find the device and model you want to update in the device list.

  • Double-click on it to open the Properties dialog box.

  • From the Properties dialog box, select the Driver tab.

  • Click the Update Driver button, then follow the instructions.

Very important: You must reboot your system to ensure that any driver updates have taken effect.