[Version]=209 M1000::Normally open contact (a contact). This contact is ON when running and it is ON when the status is set to RUN. M1001::Normally OFF contact (b contact). This contact is OFF in running and it is OFF when the status is set to RUN. M1002::ON only for 1 scan after RUN. Initial pulse is contact a. It will get positive pulse in the RUN moment. Pulse width=scan period. M1003::Off only for 1 scan after RUN. Initial pulse is contact a. It will get negative pulse in the RUN moment. Pulse width=scan period. M1004::Reserved M1005::Reserved M1006::Output frequency is 0 M1006=On M1007::The operation direction of AC motor drives (FWD) M1007=Off¡A(REV) M1007=On M1008::Reserved M1009::Reserved M1010::Reserved M1011::10ms clock pulse, 5ms On/5ms Off M1012::100ms clock pulse, 50ms On / 50ms Off M1013::1s clock pulse, 0.5s On / 0.5s Off M1014::1min clock pulse, 30s On / 30s Off M1015::Frequency attained M1015=On M1016::Parameter read/write error M1016=On M1017::Succeed to write parameter M1017=On M1018::Enable State of high-speed counter function (When M1028=On) M1019::Reserved M1020::Zero flag M1021::Borrow flag M1022::Carry flag M1023::Divisor is 0 M1024::Reserved M1025::RUN (ON) / STOP (OFF) the AC motor drive M1026::The operation direction of the AC motor drive (FWD: OFF, REV: ON) M1027::Reserved M1028::Enable (ON)/disable (OFF) high-speed counter function M1029::Clear the value of high-speed counter M1030::Decide to count up (OFF)/count down (ON) M1031::Reserved D1000::Reserved D1001::System program version (user can read PLC program version from this register. For example, D1001 = H XX10 means version 1.0 D1002::Program capacity D1003::Sum of program memory D1004::Reserved D1005::Reserved D1006::Reserved D1007::Reserved D1008::Reserved D1009::Reserved D1010::Present scan time (Unit: 0.1ms) D1011::Minimum scan time (Unit: 0.1ms) D1012::Maximum scan time (Unit: 0.1ms) D1013::Reserved D1014::Reserved D1015::Reserved D1016::Reserved D1017::Reserved D1018::Reserved D1019::Reserved D1020::AC motor drive Output frequency D1021::AC motor drive Output current D1022::The ID of the extension card:02 USB Card03 12.Bit A/D (2CH) 12.Bit D/A (2CH)04. Relay Card-2C05. Relay Card-3A06. 3IN/3OUT Card07. PG Card D1023::Reserved D1024::Reserved D1025::The present value of the high-speed counter (low byte) D1026::The present value of the high-speed counter (high byte) D1027::Frequency Output of the PID control D1028::The value of AVI (analog voltage input) 0-10V corresponds to 0-1023 D1029::The value of ACI (analog current input) 4-20mA corresponds to 0-1023 or the value of AVI2 (analog voltage input) 0-10V corresponds to 0-1023 D1030::The value of V.R digital keypad 0-10V corresponds to 0-1023 D1031::Reserved D1032::Reserved D1033::Reserved D1034::Reserved D1035::Reserved D1036::AC motor drive error code D1037::Reserved D1038::Reserved D1039::Reserved D1040::Analog output value (0~65535) corresponds to 0~10V D1041::Reserved D1042::Reserved D1043::User defined (when Pr.00.04 is set to 2, the register data will be displayed as C xxx) D1044::High-speed counter modeDownload Driver Pack
After your driver has been downloaded, follow these simple steps to install it.
Expand the archive file (if the download file is in zip or rar format).
If the expanded file has an .exe extension, double click it and follow the installation instructions.
Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.
Find the device and model you want to update in the device list.
Double-click on it to open the Properties dialog box.
From the Properties dialog box, select the Driver tab.
Click the Update Driver button, then follow the instructions.
Very important: You must reboot your system to ensure that any driver updates have taken effect.
For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.