[HiPusMsg] M0=The parameter setting of device D can not be in the special D range (1000~2000) M1=Start frequency should be less than target frequency M2=Gap frequency should be less or equal to (target frequency-start frequency) M3=Total number of pulse should be greater than (acceleration/deceleration pulse number*2) M4=Total pulse output number in accel/decel area should be greater than the number of acceleration/deceleration step M5=Possess the error settings of pulse output with accel/decel speed: M6=Section M7=switch to section M8=This is acceleration switch, please confirm each field again. M9=This is deceleration switch, please confirm each field again. M10=, target frequency can not be equal to start frequency M11=, gap frequency of acceleration should be 1Hz~32700Hz M12=, gap frequency of deceleration should be -1Hz~-32700Hz M13=, output target number should be greater than (GF*GT/1000)*((TF-SF)/GF) M14=Acceleration/Deceleration pulse output settings of adjustable slope: M15=OK M16=Next M17=Setting range of constant K is K M18=Device number exceeds upper bound: M19=Wizard will not generate interrupt mark M20=Please add interrupt mark by yourself M21=otherwise system error will occur! M22=PWM instruction, pulse output time can not be greater than output cycle M23=PLSR instruction, setting range of max. output frequency is M24=PLSR instruction, setting range of total output pulse is M25=PLSR instruction, max. output pulse frequency error or total pulse setting error, M26=cause error result M27=PLSR instruction, setting range of acceleration/deceleration time M28=Target frequency can not be the M29=same as start frequency M30=Output frequency setting range: K1~K10,000Hz M31=Output frequency setting range: K1~K32,000Hz M32=Output frequency setting range: K1~K200,000Hz M33=Output pulse number setting range: K1~K32767 M34=Output pulse number setting range: K1~K2,147,483,647 M35=Pulse unit switch, when M1070=ON, unit is 100us, when M1070=OFF, unit is 1ms M36=Relative device M1258, the inverse of Y0 pulse output signal M37=Pulse unit switch, when M1071=ON, unit is 100us, when M1071=OFF, unit is 1ms M38=Relative device M1259,the inverse of Y2 pulse output signal M39=Setting range: K10~K32,767Hz, it must be the multiple of 10 M40=setting range: K110~K32,767 M41=Setting range: K10~K200,000Hz, it must be the multiple of 10 M42=Setting range: K110~K2,147,483,647 M43=Output setting of special high-speed pulse (50KHz): M44=Parameter of PLSR should be constant K when drawing timing diagram M45=Can not build the sharing memory M46=Setting range of constant H is H M47=Max. frequency of PLSR output M48=Total pulse number of PLSR output M49=PLSR Acceleration/Decleration time M47=PLSR target frequency M48=PLSR total output pulse M49=PLSR acceleration/deceleration time M50=must M51=above M52=Start frequency [PidMsgHscMsg] M0=Setup High-Speed Counter instruction M1=Setup PID instruction M2=Output value is within latched data register area M3=Confirm M4=Finish M5=Normal frequency M6=Double frequency M7=Next M8=Please input value M9=Value range M10=PID - 16 bits instruction M11=DPID - 32 bits instruction M12=Three times frequency M13=Four times frequency M14=Saturated output value : upper bound should be greater than lower bound M15=Saturated integration value : upper bound should be greater than lower bound M16=Target value is within the setting range of parameter value M17=Present value is within the setting range of parameter value M18=Output value is within the setting range of parameter value M19=Counting direction of counter is not selected yet M20=The conditions for count up and down are the same M21=Return to edition screen to modify or not? M22=The device number should be a octal number M23=Setting range of constant K is K-2,147,483,648 ~ K2,147,483,647 M24=Setting range of constant H is H0000~HFFFF M25=The device number exceeds upper bound: M26=Conditional contact and counter contact are used repeatedly. Do you want to modify? M27=Please back to edition screen to modify. M28=When M1260=On, input point X5 is a reset signal. M29=Do you want to generate initial instruction? M30=Pulse input : X M31=Increasing input : X M32=Decreasing input : X M33=Reset input : X M34=Start input : X M35=A-phase input : X M36=B-phase input : X M37=DHSZ--lower bound of area comparison should be less than upper bound of area comparison M38=High-Speed Counter Instruction Wizard for ES/EX/SS Series M39=High-Speed Counter Instruction Wizard for SA/SX/SC Series M40=comparison value M41=upper bound M42=lower bound M43=High-Speed Counter Instruction Wizard for PB Series M44=High-Speed Counter Instruction Wizard for PC/PA/PH Series M45=The parameter setting of device D is in the special D range (1000~2000) M46=Would you want to modify? M47=Parameter setting is not latched register M48=(Latched type for parameter setting is recommened for saving relative parameter for futher usage) M49=The register of GPWM output cycle is in the available range of the register of parameter M50=The register numbers of target value, present value, and output value of PID command can't be overlapped for any two of them. M51=The register of GPWM output cycle can't be same as any of the registers of target value, present value, and output value of PID command. M52=(Note: the indicated registers of target value, present value and output value will occupy continuous 2 registers for 32-bit PID command) M53=Rising-edge mode M54=Falling-edge mode M55=Both rising-edge and falling-edge mode M56=(For SC) M57=(For PH) [OriControlMsg] M0=Y0 output M1=AB-phase output of Y0 and Y1 (A-phase leads B-phase) M2=AB-phase output of Y0 and Y1 (B-phase leads A-phase) M3=Y1 output M4=Y2 output M5=AB-phase output of Y2 and Y3 (A-phase leads B-phase) M6=AB-phase output of Y2 and Y3 (B-phase leads A-phase) M7=Y3 output M8=Next M9=OK M10=ZRN instruction - setting range of zero return is K M11=ZRN instruction - setting range of jog is K M12=PLSV instruction - setting range of pulse output frequency is K M13=RAMP instruction - setting range of scan times is K1 - K32767 M14=DRVI instruction - setting range of pulse output number is K M15=OK M16=Next M17=Setting range of constant K is K M18=Device number exceeds upper bound: M19=DRVI instruction - setting range of pulse output frequency is K M20=DRVA instruction - setting range of pulse output number is K M21=DRVA instruction - setting range of pulse output frequency is K M22=Numeric range: M23=The current value register ( D1349 high word, D1348 low word ) of CH0 pulse or current value register ( D1351 high word, M24=D1352 low word ) of CH1 will both be used in positioning control instructions and pulse output instructions and this will result M25=( ABSR ) and relative/absolute position control instruction ( DRVI / DRVA ). M26=Notes when using positioning control instructions (ZRN, DRVI, DRVA) and pulse output instructions (PLSY, PWM, PLSR) M27=at the same time: [PLCLinkMsg] M0=Finish M1=Next M2=Baud Rate should be less than 9600 bps, and time out should be greater than 1000ms M3=System will auto change the time-out to 1000 M4=Please input value M5=Are you sure to delete all records? M6=Are you sure to delete this record? M7=This port can not open or be occupied: COM M8=Communication error (COM M9=The ID number between master station and slave station can not be the same. M10=Please check the following slave ID, and make sure to delete or not ? M11=The item numbers of read/write are more than 16, so the value of communication time out must more than 500ms. M12=To avoid communication time out will occour. M13=, current setting value of communication time out is : M14=Recommend going back to modify M15=The setting number of Data register for reading out data is within special data register (D1000 - D1999): M16=The setting number of Data register for writting in data is within special data register (D1000 - D1999): M17=Series : M18=Setting range of slave communication address (ID) : M19=Device M20=Value M21=ID M22=Reading addr. M23=Reading num. M24=Writting addr. M25=Writting num. M26=Please make sure that have setup all conditional clause ! M27=Yes : Product instruction codes and close editor window of wizard M28=No : Go back to editor window M29=Current item numbers of reading out data or writing in data are more than 16, its number will be reset to 0 M30=Slave ID address : M31=Addr M32=Address Range¡G M33=Please input start address of ID1 from slave station! M34=Time out !! [IntWizardMsg] M0=Confirm M1=Input interrupts M2=Timer interrupts M3=Counter interrupts M4=Character receiving interrupt M5=Pulse output interrupt M6=Time interrupt pointer is used repeatedly, using it to replace the old one or not? M7=External interrupt pointer is used repeatedly, using it to replace the old one or not? M8=External input interrupt is used for occupying input points, it cannot be used for high-speed counter input. M9=High-speed counter input is used for occupying input points, it cannot be used for external input interrupt. M10=Time setting range is 10 - 99 (time base = 1ms) M11=Time setting range is 1 - 99 M12=(time base = 1ms) M13=(time base = 0.1ms) M14=Receiving completed interrupt [CRWizardMsg] M0=Confirm M1=If it needs to correct fault? M2=The following CR# which store address of reading data (FROM instruction) is the same: M3=Channel 1 : OFFSET setting range should be M4=Channel 1 : GAIN setting range should be M5=Channel 1 : The result of (GAIN-OFFSET) should be M6=Channel 2 : OFFSET setting range should be M7=Channel 2 : GAIN setting range should be M8=Channel 2 : The result of (GAIN-OFFSET) should be M9=Channel 3 : OFFSET setting range should be M10=Channel 3 : GAIN setting range should be M11=Channel 3 : The result of (GAIN-OFFSET) should be M12=Channel 4 : OFFSET setting range should be M13=Channel 4 : GAIN setting range should be M14=Channel 4 : The result of (GAIN-OFFSET) should be M15=No action is selected M16=Conditional : M17=The address used to save data M18=Channel 5 : OFFSET setting range should be M19=Channel 5 : GAIN setting range should be M20=Channel 5 : The result of (GAIN-OFFSET) should be M21=Channel 6 : OFFSET setting range should be M22=Channel 6 : GAIN setting range should be M23=Channel 6 : The result of (GAIN-OFFSET) should be M24=Next M25=Normal frequency M26=Double frequency M27=Four times frequency M28=Up/down count is controlled by external input M29=Up/down count is controlled by register M30=DVP04AD Analog Input Module M31=DVP06XA Analog Input/Output Mixed Module M32=DVP04TC Thermocouple Sensors Module M33=DVP04PT Platinum Temperature Sensor (PT100) M34=DVP02DA Analog Output Module M35=DVP04DA Analog Output Module M36=DVP08RT Resistor Thermocouple M37=DVP01HC High-Speed Counter Module M38=Please check the input setting of each channel that is relative to OFFSET and GAIN value M39=Setting range : M40=Setting range of input voltage mode : M41=Setting range of input current mode : M42=Does not set any parameter, exit this editor window or not ? M43=ELC-AN04ANNN Analog to Digital Converter Module M44=ELC-AN06AANN Analog Input/Output Mixed Module M45=ELC-PT04ANNN Platinum Temperature Sensors Module M46=ELC-AN02NANN Digital to Analog Converter Module M47=ELC-TC04ANNN Thermocouple Sensors Module M48=ELC-AN04NANN Digital to Analog Covnerter Module M49=DVP02HC High-Speed Counter Module M50=DVP01PU-S Position Control Unit Module M51=DVP01PU-H Position Control Unit Module [CommAppMsg] M0=exceed RS transmission number range (0-256) M1=Next M2=No item is selected. If setting communication instruction (D1120) only? M3=Back M4=Finish M5=Out of the transmission number range M6=Out of the receive number range M7=Out of the LRC/CRC operation range M8=Out of MODRD communication address range M9=Out of MODRD data length range M10=Out of MODWR communication address range M11=Out of MODRW communication address range M12=Out of MODRW function code range M13=Out of MODRD read data address range M14=Out of MODRW read/write data length range (K1~K8 or H1~H8) M15=If function code is 3, start condition can't use LDP or LDF instruction. M16=Out of FWD communication address range M17=Out of FWD AC drive frequency range M18=Out of FWD settings (K1~K2) M19= K1: instruction for specific AC drive M20= K2: instruction for all connected AC drives M21=Out of REV communication address range M22=Out of REV AC drive frequency range M23=Out of REV settings (K1~K2) M24=Out of STOP communication address range M25=Out of STOP AC drive frequency range M26=Out of STOP settings (K1~K2) M27= K1: instruction for specific AC drive M28= K2: instruction for all connected AC drives M29=Out of RDST communicationi address range M30=Out of RDST settings (K0~K3) M31= K0:frequency instruction M32= K1:output frequency M33= K2:output current M34= K3:running instruction M35=Out of RSTEF communication address range M36=Out of RSTEF settings (K1~K2) M37=Cannot build share memory. M38=The start word of communication control string has not set yet. M39=The first end word of communication control string has not set yet. M40=The second end word?of communication control string has not set yet. M41=Please press "setting the content" button for setting. M42=Setting range : M43=Upper bound of device number: [GsmModemMsg] M0=Confirm M1=Warnning M2=Select at least one sending mode!! M3=The RS instruction start-up condition of using "Detect if GSM MODEM registration is successful" can not be the same one as "Send message by TEXT mode"!! M4=The RS instruction start-up condition of using "Detect if GSM MODEM registration is successful" can not be the same one as "Send message by PDU mode"!! M5=The RS instruction start-up condition of using "Send message by TEXT mode" can not be the same one as "Send message by PDU mode"!! M6=The RS instruction start-up condition of using "Send message dial" can not be the same one as "Send message"!! M7=The RS instruction start-up condition of using "Detect if GSM MODEM registration is successful" can not be the same one as "Send message dial"!! M8=Finish M9=The RS instruction start-up condition of using "Detect if GSM MODEM registration is successful" can not be the same one as "Send message"!! M10=The RS instruction start-up condition of using "Send message by TEXT mode" can not be the same one as "Send message dial"!! M11=Please input Mobile phone number!! M12="The RS instruction start-up condition of using "Send message by TEXT mode" can not be the same one as "Send message"!! M13=The RS instruction start-up condition of using "Send message by PDU mode" can not be the same one as "Send message dial"!! M14=Key in the number of message service center!! M15=The RS instruction start-up condition of using "Send message by PDU mode" can not be the same one as "Send message"!! M16=The RS instruction start-up condition of using "Send message of modem content" can not be the same one as "PDU code"!! M17=The RS instruction start-up condition of using "Detect if GSM MODEM registration is successful" can not be the same one as "Send message of modem content"!! M18=The RS instruction start-up condition of using "Detect if GSM MODEM registration is successful" can not be the same one as "PDU code"!! M19=The RS instruction start-up condition of using "Send message by TEXT mode" can not be the same one as "Send message of modem content"!! M20=The RS instruction start-up condition of using "Send message by TEXT mode" can not be the same one as "PDU code"!! M21=The RS instruction start-up condition of using "TEXT mode_Send message dial" can not be the same one as "Send message of modem content"!! M22=The RS instruction start-up condition of using "TEXT mode_Send message dial" can not be the same one as "PDU code"!! M23=The RS instruction start-up condition of using "TEXT mode_Send message" can not be the same one as "Send message of modem content"!! M24=The RS instruction start-up condition of using "TEXT mode_Send message" can not be the same one as "PDU code"!! M25=The RS instruction start-up condition of using "Send message by PDU mode" can not be the same one as "Send message content"!! M26=The RS instruction start-up condition of using "Send message by PDU mode" can not be the same one as "PDU mode"!! [TemperateMsg] M0=Timeout! M1=Communication error M2=Communication port has been used or no this port! M3=Range M4=File M5=lost! M6=Open file M7=error!Download Driver Pack
After your driver has been downloaded, follow these simple steps to install it.
Expand the archive file (if the download file is in zip or rar format).
If the expanded file has an .exe extension, double click it and follow the installation instructions.
Otherwise, open Device Manager by right-clicking the Start menu and selecting Device Manager.
Find the device and model you want to update in the device list.
Double-click on it to open the Properties dialog box.
From the Properties dialog box, select the Driver tab.
Click the Update Driver button, then follow the instructions.
Very important: You must reboot your system to ensure that any driver updates have taken effect.
For more help, visit our Driver Support section for step-by-step videos on how to install drivers for every file type.